Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Characterization of a Multilayered Dielectric Transmissive Phase Modulator

We describe a multilayered dielectric stack configuration designed specifically for use as a transmissive phase modulator for broadband optical signals. Applications for this device range from full aperture wavefront correction to nonmechanical beam steering arrays for free space optical communication links. Our implementation employs alternating GaAs and AlAs layers of varying thickness on a GaAs substrate to create a bandpass region of high average transmission centered about the one micrometer wavelength. Within this transmission bandpass, the phase component of the complex transmission coefficient varies in a near-linear fashion with respect to wavelength. The transmission bandpass is designed to have a bandwidth of 21.0 nm (or 6.3THz frequency bandwidth) and to have an edge-to-edge phase change of greater than 47T radians. Modification of the stack materials' optical properties causes the transmission profile to shift spectrally, resulting in a phase modulation for bands of transmitted frequencies. Our broadband phase modulator imparts up to a full-cycle of phase modulation with low loss and low group velocity dispersion. We identify several methods for implementing the requisite modulation, including refractive index modulation through free carrier injection and optical path length modulation through variation in angle of incidence. At least one sample comprising 91 alternating layers has been fabricated to exhibit the bandpass properties required for optical signal phase modulation. We experimentally characterize the sample using an interferometer and spectrometer to measure the transmitted signal spectrum and relative phase modulation. We compare the experimental data to computational predictions and discuss the results.

Keys, Andrew S.↗

Weak-light Phase-locking for LISA

The long armlengths of the LISA interferometer, and the finite aperture of the telescope, leads to an optical power attenuation of approximately equal to 10(exp -10) of the transmitted to received light. Simple reflection at the end of the arm is therefore not an optimum interferometric design. Instead, a local laser is offset phase-locked to the weak incoming beam, transferring the phase information of the incoming to the outgoing light. This paper reports on an experiment to characterize a weak light phase-locking scheme suitable for LISA in which a diode-pumped, Nd:YAG, non-planar ring oscillator (NPRO) is offset phase-locked to a low power (13pW) frequency stabilised master NPRO. Preliminary results of the relative phase noise of the slave laser shows shot noise limited performance above 0.4 Hz. Excess noise is observed at lower frequencies, most probably due to thermal effects in the optical arrangement and phase sensing electronics.

McNamara, Paul W.↗

Relative-Motion Sensors and Actuators for Two Optical Tables

Optoelectronic sensors and magnetic actuators have been developed as parts of a system for controlling the relative position and attitude of two massive optical tables that float on separate standard air suspensions that attenuate ground vibrations. In the specific application for which these sensors and actuators were developed, one of the optical tables holds an optical system that mimics distant stars, while the other optical table holds a test article that simulates a spaceborne stellar interferometer that would be used to observe the stars. The control system is designed to suppress relative motion of the tables or, on demand, to impose controlled relative motion between the tables. The control system includes a sensor system that detects relative motion of the tables in six independent degrees of freedom and a drive system that can apply force to the star-simulator table in the six degrees of freedom. The sensor system includes (1) a set of laser heterodyne gauges and (2) a set of four diode lasers on the star-simulator table, each aimed at one of four quadrant photodiodes at nominal corresponding positions on the test-article table. The heterodyne gauges are used to measure relative displacements along the x axis.

Gursel, Yekta↗

Optical Tweezers Array and Nimble Tweezers Probe Generated by Spatial- Light Modulator

An optical tweezers is being developed at the NASA Glenn Research Center as a visiblelight interface between ubiquitous laser technologies and the interrogation, visualization, manufacture, control, and energization of nanostructures such as silicon carbide (SiC) nanotubes. The tweezers uses one or more focused laser beams to hold micrometer-sized particles called tools (sometimes called tips in atomic-force-microscope terminology). A strongly focused laser beam has an associated light-pressure gradient that is strong enough to pull small particles to the focus, in spite of the oppositely directed scattering force; "optical tweezers" is the common term for this effect. The objective is to use the tools to create carefully shaped secondary traps to hold and assemble nanostructures that may contain from tens to hundreds of atoms. The interaction between a tool and the nanostructures is to be monitored optically as is done with scanning probe microscopes. One of the initial efforts has been to create, shape, and control multiple tweezers beams. To this end, a programmable spatial-light modulator (SLM) has been used to modify the phase of a laser beam at up to 480 by 480 points. One program creates multiple, independently controllable tweezer beams whose shapes can be tailored by making the SLM an adaptive mirror in an interferometer (ref. 1). The beams leave the SLM at different angles, and an optical Fourier transform maps these beams to different positions in the focal plane of a microscope objective. The following figure shows two arrays of multiple beams created in this manner. The patterns displayed above the beam array control the intensity-to-phase transformation required in programming the SLM. Three of the seven beams displayed can be used as independently controllable beams.

Decker, Arthur J.↗

The radial velocity search for extrasolar planets

Stars are observed with a ground-based instrument designed to measure small changes in the line-of-sight velocities. The purpose of the observations is to detect large planets by the oscillatory reflex motion they induce on the stars they are orbiting. The instrument is an optical spectrometer for which wavelengths are first calibrated by transmission through a tunable Fabry-Perot etalon interferometer. Changes in the line-of-sight velocities are revealed by changes in the Doppler shift of the absorption-line spectra of stars. The scrambling of incident light by an optical fiber and the stability of wavelength calibration by a tilt-tunable Fabry-Perot etalon provide immunity to systematic errors that historically have effected more conventional radial velocity spectrographs. A cross-dispersed echelle spectrograph spatially separates the orders of constructive interference transmitted through the etalon. Selecting several echelle diffraction orders in the vicinity of 4250 to 4750 A, which are imaged on a CCD, about 350 points on the profile of the stellar spectrum are sampled by successive orders of interferometric transmission through the etalon.

Mcmillen, R. S.↗

Cryogenic Refractive Index of Heraeus Homosil Glass

This paper reports measurements of the refractive index of Homosil (Heraeus) over the wavelength range of 0.34-3.16 microns and temperature range of 120-335 K. These measurements were performed by using the Cryogenic High Accuracy Refraction Measuring System (CHARMS) facility at the NASAs Goddard Space Flight Center. These measurements were in support of an integrated Structural-Thermal-Optical-Performance (STOP) model that was developed for a field-widened Michelson interferometer that is being built and tested for the High Spectral Resolution Lidar (HSRL) project at the NASA Langley Research Center (LaRC). The cryogenic refractive index measurements were required in order to account for the highly sensitivity performance of the HSRL instrument to changes in refractive index with temperature, temperature gradients, thermal expansion, and deformation due to mounting stresses. A dense coverage of the absolute refractive index over the aforementioned wavelength and temperature ranges was used to determine the thermo-optic coefficient (dn/dT) and dispersion relation (dn/d(lamda)) as a function of wavelength and temperature. Our measurements of Homosil will be compared with measurements of other glasses from the fused silica family studied in CHARMS as well as measurements reported elsewhere in literature.

cryogenic↗

Cryogenic Refractive Index of Heraeus Homosil Glass

This paper reports measurements of the refractive index of Homosil (Heraeus) over the wavelength range of 0.343.16 m and temperature range of 120335 K. These measurements were performed by using the Cryogenic High Accuracy Refraction Measuring System (CHARMS) facility at the NASAs Goddard Space Flight Center. These measurements were in support of an integrated Structural-Thermal-Optical-Performance (STOP) model that was developed for a field-widened Michelson interferometer that is being built and tested for the High Spectral Resolution Lidar (HSRL) project at the NASA Langley Research Center (LaRC). The cryogenic refractive index measurements were required in order to account for the highly sensitivity performance of the HSRL instrument to changes in refractive index with temperature, temperature gradients, thermal expansion, and deformation due to mounting stresses. A dense coverage of the absolute refractive index over the aforementioned wavelength and temperature ranges was used to determine the thermo-optic coefficient (dndT) and dispersion relation (dnd) as a function of wavelength and temperature. Our measurements of Homosil will be compared with measurements of other glasses from the fused silica family studied in CHARMS as well as measurements reported elsewhere in literature.

Homosil↗

Multiplex Fabry-Perot interferometer

Attention is given to a Fabry-Perot interferometer (FPI) technique in which one of the etalon plates is moved over a large optical distance while the other remains fixed, thus exploiting the multiplex advantage of the instrument. This technique involves the application of Fourier-transform spectrometer to the multiple harmonics passing through the FPI etalon. It is shown that the multiplex FPI acts as several Michelson interferometers working at the same time, over the same spectral interval, and at different spectral resolutions. A high spectral resolution has been obtained over a large wavenumber interval, while the advantage of a reasonable scan length has been retained.

Hays, Paul B.↗

The StarLight formation-flying interferometer system architecture

The StarLight Project, scheduled for a 6-month mission in 2006, will demonstrate the new technologies of spaceborne long-baseline optical interferometry and precision formation flying necessary for the Terrestrial Planet Finder and other future astropohysics missions.

StarLight Project interferometers↗

Mesospheric and lower thermospheric winds, temperatures densities, and volume emission rates

This memo has been written to report on the progress made under grant NAG1-1315 and to request a continuation of funding for this work. Our proposal involved a plan to utilize an existing ground-based chain of optical and radar facilities to assemble a comprehensive, long-term, multi-station base of upper-mesospheric and lower thermospheric measurements of neutral winds, temperatures, and volume emission rates that can be used to make comparisons with data from the HRDI and WINDII instruments that are flying aboard the UARS spacecraft. The ground-based, optical data were to be obtained on a routine basis from five geographically separated observatories at: Thule, Greenland; Sondrestrom, Greenland; Watson Lake, Yukon (replacing Calgary, Alberta); Ann Arbor, Michigan; and Maynooth, Eire. Several different optical instruments are present at these sites: the total array of instruments is comprised of five Fabry-Perot interferometers, two half meter Ebert-Fastie spectrometers, one all-sky CCD imager, and a near infra-red Michelson Fourier transform spectrometer. In addition to these optical instruments, data were to be obtained from the incoherent scatter radar at Sondrestrom, Greenland. These radar measurements are comprised of neutral winds, temperatures, and densities from altitudes between approximately 70 - 120 km. The optical measurements are obtained locally from specific altitudes depending on the emission line studied. For example, red line optical data come from about 220 km. In this report we summarize the progress made in obtaining these data and relate it to the specific tasks outlined in the original grant application. These tasks are discussed in the next section. Progress towards their completion is discussed in section three, while future plans and summary are described in section four.

Killeen, Timothy L.↗

A 15 Meter Laser-Stabilized Imaging Interferometer

The Laser-Stabilized Imaging Interferometer (LASII) concept is being developed as a candidate for the next generation of optical resolution beyond Hubble Space Telescope (HST). The essential ingredients are: a rigid and stable structure to minimize mechanical and thermal distortion, active control of the optical geometry by a laser metrology system, a self-deploying structure fitting into a single launch vehicle, and ultraviolet operation. We have modified earlier design concepts to fit the scale of an intermediate sized NASA mission.

Imaging↗

Transverse Pupil Shifts for Adaptive Optics Non-Common Path Calibration

A simple new way of obtaining absolute wavefront measurements with a laboratory Fizeau interferometer was recently devised. In that case, the observed wavefront map is the difference of two cavity surfaces, those of the mirror under test and of an unknown reference surface on the Fizeau s transmission flat. The absolute surface of each can be determined by applying standard wavefront reconstruction techniques to two grids of absolute surface height differences of the mirror under test, obtained from pairs of measurements made with slight transverse shifts in X and Y. Adaptive optics systems typically provide an actuated periscope between wavefront sensor (WFS) and commonmode optics, used for lateral registration of deformable mirror (DM) to WFS. This periscope permits independent adjustment of either pupil or focal spot incident on the WFS. It would be used to give the required lateral pupil motion between common and non-common segments, analogous to the lateral shifts of the two phase contributions in the lab Fizeau. The technique is based on a completely new approach to calibration of phase. It offers unusual flexibility with regard to the transverse spatial frequency scales probed, and will give results quite quickly, making use of no auxiliary equipment other than that built into the adaptive optics system. The new technique may be applied to provide novel calibration information about other optical systems in which the beam may be shifted transversely in a controlled way.

Bloemhof, Eric E.↗

Optics of Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII): Delay Lines and Alignment

We present the optics of Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) as it gets ready for launch. BETTII is an 8-meter baseline far-infrared (30-90 microns) interferometer mission with capabilities of spatially resolved spectroscopy aimed at studying star formation and galaxy evolution. The instrument collects light from its two arms, makes them interfere, divides them into two science channels (30-50 microns and 60-90 microns), and focuses them onto the detectors. It also separates out the NIR light (1-2.5 microns) and uses it for tip-tilt corrections of the telescope pointing. Currently, all the optical elements have been fabricated, heat treated, coated appropriately and are mounted on their respective assemblies. We are presenting the optical design challenges for such a balloon borne spatio-spectral interferometer, and discuss how they have been mitigated. The warm and cold delay lines are an important part of this optics train. The warm delay line corrects for path length differences between the left and the right arm due to balloon pendulation, while the cold delay line is aimed at introducing a systematic path length difference, thereby generating our interferograms from where we can derive information about the spectra. The details of their design and the results of the testing of these opto-mechanical parts are also discussed. The sensitivities of different optical elements on the interferograms produced have been determined with the help of simulations using FRED software package. Accordingly, an alignment plan is drawn up which makes use of a laser tracker, a CMM, theodolites and a LUPI interferometer.

Dhabal, Arnab↗

Pulsed laser spectral measurement using a Fabry-Perot interferometer: Limits to resolution

We are developing a Doppler lidar system using the edge technique to measure atmospheric wind profiles. The edge technique requires a laser with a narrow spectral bandwidth and a high resolution optical filter. The lidar system will use a Nd:YAG laser operating at 1.064 microns and a high resolution Fabry-Perot interferometer for the edge filter. The Doppler shift measurement is made by locating the laser on the edge of the filter's spectral response function. Due to the steep slope on the edge, large changes in the filter transmission will be observed for small changes in frequency. The Doppler shift can be determined from a measurement of this change in filter transmission if the filter spectral response function in the region of the measurement is well known. Recently developed injection seeded solid state lasers have made near transform limited laser output readily available for lidar work. Injection-seeded Nd:YAG laser exhibit single mode output with smooth Gaussian temporal pulse shapes. Results of an experiment we conducted to evaluate the effects of a short Gaussian temporal input pulse on the spectral response of a high resolution Fabry-Perot interferometer are presented.

Notari, Anthony↗

Integrated Optics Achromatic Nuller for Stellar Interferometry

This innovation will replace a beam combiner, a phase shifter, and a mode conditioner, thus simplifying the system design and alignment, and saving weight and space in future missions. This nuller is a dielectric-waveguide-based, four-port asymmetric coupler. Its nulling performance is based on the mode-sorting property of adiabatic asymmetric couplers that are intrinsically achromatic. This nuller has been designed, and its performance modeled, in the 6.5-micrometer to 9.25-micrometer spectral interval (36% bandwidth). The calculated suppression of starlight for this 15-cm-long device is 10(exp -5) or better through the whole bandwidth. This is enough to satisfy requirements of a flagship exoplanet-characterization mission. Nulling interferometry is an approach to starlight suppression that will allow the detection and spectral characterization of Earth-like exoplanets. Nulling interferometers separate the light originating from a dim planet from the bright starlight by placing the star at the bottom of a deep, destructive interference fringe, where the starlight is effectively cancelled, or nulled, thus allowing the faint off-axis light to be much more easily seen. This process is referred to as nulling of the starlight. Achromatic nulling technology is a critical component that provides the starlight suppression in interferometer-based observatories. Previously considered space-based interferometers are aimed at approximately 6-to-20-micrometer spectral range. While containing the spectral features of many gases that are considered to be signatures of life, it also offers better planet-to-star brightness ratio than shorter wavelengths. In the Integrated Optics Achromatic Nuller (IOAN) device, the two beams from the interferometer's collecting telescopes pass through the same focusing optic and are incident on the input of the nuller.

Ksendzov, Alexander↗

Overview of the Keck Interferometer

This is a presentation about the Keck Interferometer which is being constructed on top of Mauna Kea, Hawaii. This includes using the world's largest telescopes for optical and near-infrared astronomy, the twin 10 meter Keck telescopes. The two Keck telescopes, in conjunction with four proposed outrigger telescopes, will be used as an interferometer to conduct observations as part of NASA's Origins Program. These observations will address a variety of topics, including the origin and evolution of planetary systems. This presentation reviews the key features of the interferometer, and the specifications of the telescopes that will be used. It shows diagrams of the site, and the basement layout. It also reviews the science for which the interferometer will be used.

vanBelle, Gerard↗

Speckle interferometry using fiber optic phase stepping

A system employing closed-loop phase-stepping is used to measure the out-of-plane deformation of a diffusely reflecting object. Optical fibers are used to provide reference and object beam illumination for a standard two-beam speckle interferometer, providing set-up flexibility and ease of alignment. Piezoelectric fiber-stretchers and a phase-measurement/servo system are used to provide highly accurate phase steps. Intensity data is captured with a charge-injection-device camera, and is converted into a phase map using a desktop computer. The closed-loop phase-stepping system provides 90 deg phase steps which are accurate to 0.02 deg, greatly improving this system relative to open-loop interferometers. The system is demonstrated on a speckle interferometer, measuring the rigid-body translation of a diffusely reflecting object with an accuracy + or - 10 deg, or roughly + or - 15 nanometers. This accuracy is achieved without the use of a pneumatically mounted optics table.

Mercer, Carolyn R.↗