Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operating costs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Techno-Economic Analysis of Green Hydrogen Energy Storage in a Cryogenic Flux Capacitor

Abstract The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. Hydrogen storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (∼1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 36% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at improved densities, but testing is ongoing. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce green GH2. The TEA compares pure hydrogen produced at a small scale for a 25 MW power system and at a large scale in a 500 MW power system. The system allowed for hydrogen imports and exports at a set price with a tank sized for 10 hours of power production. The two power producing technologies are a combined cycle gas turbine (CCGT) and hydrogen fuel cells. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity (LCOE), levelized cost of hydrogen (LCOH), and levelized cost of storage (LCOS) are developed based on the capital cost and operating cost of the systems. The results are shown for current costs using a 2021 benchmark and DOE projections for cost improvements by 2030. The TEA showed that onsite hydrogen generation from SMR has an LCOH of about 1.4 to 2 USD per kg over the life of the plant and the PV hydrogen production LCOH is about 5.2 to 5.5 USD per kg. The LCOS of conventional GH2 systems is estimated to be $210/MWh and cost of storage for LH2 systems is $205/MWh for fuel cell systems and $249/MWh for CCGT systems. CFC improved the LCOS of all these systems to $198/MWh, $191/MWh and $233/MWh respectively. The LCOE also improved with conventional systems between $171/MWh and $228/MWh improved by CFC to between $167/MWh and $212/MWh. Using projections for improvement in costs following DOE’s goals by 2030, green hydrogen improved to as low as $78/MWh LCOS and LCOE for conventional cases. CFC improved over conventional storage with the lowest LCOS being $62/MWh and the lowest LCOE being $73/MWh. These results correspond to an LCOH of $2/kg. Finally, the TEA shows how LCOE is improved for hydrogen conditioning and storage over conventional systems and caverns in the 10 to 50 hour range.

08 HYDROGEN↗

Review of Life Cycle Cost Analysis Tools

Life cycle costing (LCC) is a vital aspect of decision-making in building retrofitting. It allows stakeholders to thoroughly assess all expenses involved throughout the lifespan of these retrofits, covering initial costs; ongoing operation, maintenance, and repair costs; and disposal costs of the system. The Federal Energy Management Program of the US Department of Energy has established clear guidelines for conducting LCC analysis, particularly for investments aimed at energy and water conservation, as well as renewable energy projects. These guidelines are detailed in the Code of Federal Regulations, 10 CFR 436, Subpart A, which outlines the methodology and procedure for LCC analysis (Department of Energy 1990). The National Institute of Standards and Technology (NIST) has developed the NIST Handbook 135 (Joshua Kneifel 2022) to standardize the process of LCC analysis within the building industry. Whereas the handbook is tailored to the needs of federal agencies, its principles and methodologies can be valuable for other organizations and industries interested in conducting life cycle costing analyses for their building projects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Using Resin to Reduce Silica in Borated Fluid - 20072

The Electric Power Research Institute (EPRI) strongly recommends the concentration of silica in the reactor coolant be limited, potential ingress be carefully controlled, and frequently monitored to assess potential silica deposits on fuel cladding surfaces. Boraflex is a product with silicone rubber encasing a neutron absorber for criticality control, and it was installed in the majority of nuclear power plant spent fuel pools. Over time and in the presence of radiation, the silicone rubber lining degrades into silica (SiO{sub 2}) and hydrogen gas. Silica is somewhat soluble in water and spent fuel pool water communicates with other plant systems during refueling outages, leading to a buildup of silica in the reactor coolant and connected systems. Due to the prevalence of Boraflex racks in spent fuel pools, the presence of silica is a chronic nuclear industry concern. To address this concern, many nuclear plants have installed reverse osmosis skid systems to remove the silica from their spent fuel pools and, by extension, from reactor coolant. These skids are expensive to install and maintain. Arcadis personnel demonstrated that an iron-impregnated resin could be used to remove silica from borated systems without impacting the water quality. The resin was readily available, inexpensive, and easy to install in existing plant equipment. During a nuclear power plant's refueling outage the iron-impregnated resin proved to be effective in reducing the need for feed and bleed operations, with concurrent cost savings and reduction in required outage water management activities. Thus, the following savings were realized: - Eliminated the need to purchase, install, and maintain a reverse osmosis system avoiding more than $10 million in up-front capital cost and ongoing operating and maintenance costs. - Removed 9.57 kilograms (21 pounds) of silica dioxide from the primary system fluid. - Reduced the volume of feed and bleed from 70,000 gallons (2.65 E+05 liters) to 35,000 gallons (1.32 E+05 liters). - Saved $380,000 in water production and disposal costs. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panel Session 35: Strategies and Successes in Increasing Efficiency and Reducing Cost to Accelerate Work While Maintaining Operational Excellence (R1.5)

This panel focused on results-based project execution and ways to improve the effectiveness of large radioactive clean-up site operations while increasing efficiency and reducing cost. Panelists discussed best practices and lessons learned from their sites and projects as they work within budgetary, resource and technological constraints. Panelist with presentations: CNS Journey (Morgan Smith)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Process Intensification Approach for CO 2 Absorption Using Amino Acid Solutions and a Guanidine Compound

Environmentally friendly amino-acid salt solutions are used for the absorption of carbon dioxide from concentrated flue-gas streams via chemical absorption. Process intensification reduces operating and capital costs by combining chemical reactions and separation operations. Here, we present a new process-intensification approach that combines the CO 2 capture and the amino-acid regeneration steps into a single process carried out in a slurry three-phase reactor. The absorbed CO 2 precipitates as a solid carbonated guanidine compound. The cycle is completed by separation of the solid precipitate to strip the CO 2 and regenerate the guanidine compound, while the liquid solution is recycled to the slurry reactor. The process was studied by modifying a model developed by the authors for a gas-liquid bubble column without the presence of the guanidine compound. The guanidine precipitation reaction was accounted for using kinetic parameters calculated by the authors in another study. The proposed model was implemented by modifying an existing computer code used for the simulation of gas-liquid bubble columns. The calculated results showed that the proposed cycle can significantly reduce energy, equipment, and operating costs and can make an important contribution to developing a competitive cost-effective large-scale process for CO 2 capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accelerating Simulation for High-Fidelity PV Inverter System Reliability Assessment with High-Performance Computing

The overall cost of photovoltaic (PV) systems has shown a downward trend during the last decade; however, PV inverter failures account for the highest cost of operation and maintenance. To address this, reliability tools with powerful computation and better accuracy are required for the lifetime prediction and degradation evaluation of PV inverters. This paper proposes an event-driven parallel computing-based simulator. The proposed simulator applies high-performance computing techniques and other accessory optimization techniques-including cluster merging, adaptive model updates, and steady-state identification-to make reliability assessments for PV inverters under given input mission profiles and operating conditions with high efficiency and high fidelity. The main idea of the simulator and its workflow are introduced. Then, a demo PV inverter system simulator is implemented, and the speedup of the total simulations of the switching model reaches 123.03 times.

high-performance computing↗

Dispatch optimization of electric thermal energy storage within System Advisor Model

A stand-alone electric thermal energy storage (ETES) system converts low-value electricity into heat using resistance heating elements. During periods of high-value electricity, an ETES system uses a thermodynamic power cycle to convert stored thermal energy back to electricity. These dispatchable systems derive value from their ability to store energy when prices are low and generate electricity when prices are favorable, i.e., energy arbitrage. Consequently, dispatch optimization of system operations, through maximizing revenue subject to system constraints, is essential to evaluate the economic value of a particular system design. While stand-alone ETES systems offer potential advantages as dispatchable grid storage technologies, there is a lack of a neutral third-party, publicly available, open-source model to evaluate the performance, dispatch, and financial viability of these systems. To address this problem, we have developed a techno-economic model for stand-alone ETES systems, within National Renewable Energy Laboratory's (NREL's) System Advisor Model (SAM). We implement a mixed-integer linear program to determine an ETES optimal operating schedule that maximizes electricity sales less maintenance costs caused by operation and cycling given temporal-varying grid electricity prices. Our contributions include a mixed-integer linear program for energy arbitrage of an ETES system, an ETES performance model through a publicly-available software (i.e., SAM), and an exercise of our model through case studies that compare ETES operational strategies and annual financial metrics. With our dispatch optimization model, we were able to improve revenue by 20% compared to a myopic heuristic while reducing the operational cost of the ETES system through decreases in cycle starts, cycles per day, and heater starts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstration and Evaluation of the Human-Technology Integration Function Allocation Methodology

There is an imminent need for the existing nuclear power plants to reduce their operating and maintenance (O&M) costs to remain economically viable. Digital technology, including automation, provides a significant opportunity for the existing nuclear power plant fleet to transform the way in which work is accomplished, reducing O&M costs, and allowing the fleet to remain economically competitive. One notable opportunity to significantly reduce O&M costs pertains to modifications to the plant equipment and main control room (MCR). Existing instrumentation and control (I&C) technologies in the MCR are highly analog, costly to operate and maintain, and demand a high cognitive and physical workload from plant staff (i.e., operators). Digitalizing the MCR has a range of broad economic benefits, including improved plant performance and reduced manual work. Further, digital I&C systems can fundamentally change the way in which plant staff operate the plant; this is the concept of operation. Human-technology integration is important to ensure that impacts to the concept of operation are done in a way that account for capabilities of people and technology. Human-technology integration employs human factors engineering (HFE) methods and principles to maximize the benefits of digital technology, reducing human error, improving overall decision-making and usability. The U.S. Department of Energy Light Water Reactor Sustainability Program is applying human-technology integration research to ensure digital technologies are safe, reliable, and efficient. This paper documents the demonstration of the human-technology guidance developed by the Light Water Reactor Sustainability Program from a first-of-a-kind digital I&C upgrade, specifically addressing function analysis and allocation for a new digital I&C system that included changes in automation levels. The program’s specific approach is included in this work, following lessons learned. This document serves as a resource for industry to follow in applying human-technology integration and HFE to digital modifications, specific to function analysis and allocation. The lessons learned should be considered in the planning and execution of HFE activities that support such digital modifications.

99 GENERAL AND MISCELLANEOUS↗

Baseline Cost Analysis of Energy Wastewater Treatment with Preliminary Feasibility Analysis of Critical Mineral Recovery

Critical mineral recovery from wastewater is an enhancement of conventional mining that can help meet growing demand. This work investigates two energy wastewaters that have previously been shown to be enriched in critical minerals, oil and gas produced water in the Permian Basin and combustion residual leachate. Treatment of these two wastewaters using reverse osmosis or thermal-based methods concentrates critical minerals, which improves the economic viability of critical mineral recovery. Revenue from mineral recovery could also offset treatment costs for operators. This work evaluates the cost of treatment for each wastewater and evaluates the potential revenue from critical minerals concentrated in the brine. The levelized cost of water for combustion residual leachate ranges from USD 1.90 to USD 16.20 (USD 2023/m 3 permeate) and for produced water ranges from USD 14.40 to USD 24.30 (USD 2023/m 3 distillate). Recovery opportunities range from USD 0.11 to USD 1.13 (USD 2023/m 3 permeate) for leachate and from USD 8.28 to USD 42.10 (USD 2023/m 3 distillate) for produced water, dominated by the value of magnesium and lithium. Comparing the maximum value of critical minerals contained in produced water and the maximum treatment costs, the value of critical minerals exceeds the cost of treatment by USD 17.80/m 3 distillate, which signals a potential revenue opportunity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Virtual storage capability of residential buildings for sustainable smart city via model-based predictive control

This paper evaluates the virtual storage capability of a residential air-conditioning (AC) system by utilizing the building mass as a thermal storage to enable sustainable cities through model-based predictive control (MPC). The control-oriented building model was developed with a grey-box model structure based on the experimental data to predict the indoor air temperature. Based on the model, the operation cost-saving potential of the MPC was investigated in a single house with different comfort levels, electricity prices, and prediction horizons. The cost-saving of the MPC was approximately 10.6 % compared to the conventional control. The MPC was expanded to a residential building cluster considering the peak demand charge. In an hourly shedding and load-up scenario, the performances of the MPC and the heuristic prior-based control (PBC) are promising. When shedding was enforced all day, the peak demand saving of the MPC was 36~38 %, whereas that of the PBC was 25.7 % compared to the baseline. In addition, the monthly electricity bill, including the operation and peak demand cost, was investigated with different demand charge rates and weather conditions. The total saving decreased with a low demand charge rate and hot conditions, and the operation cost saving was compromised with more aggressive demand shedding.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Overview of the Design and Optimized Operation of Vanadium Redox Flow Batteries for Durations in the Range of 4–24 Hours

An extensive review of modeling approaches used to simulate vanadium redox flow battery (VRFB) performance is conducted in this study. Material development is reviewed, and opportunities for additional development identified. Various crossover mechanisms for the vanadium species are reviewed, and their effects on its state of charge and its state of health assessed. A stack design focusing on flow fields and an electrode design tailored to various flow fields are reviewed. An operational strategy that takes these parameters into account is reviewed for various operating envelopes, chosen based on end user preference in terms of minimizing capital cost or operation and maintenance cost. This work provides a framework for the design and operation of a VRFB for various grid services.

25 ENERGY STORAGE↗

Simulation-based assessment on stochastic load scheduling for building cooling systems

Here, to fill knowledge gaps related to stochastic load scheduling, we performed a comprehensive evaluation of the stochastic load scheduling for building cooling systems. Specifically, we studied the common uncertain variables in the load scheduling process for building cooling systems and categorized those variables based on their dynamic patterns. We then developed a generic stochastic load scheduling framework and applied it to building cooling systems that served a simulated community. This community consists of 100 heterogeneous houses and serves as a virtual testbed for evaluating the performance of stochastic load scheduling. In this evaluation, we considered representatives of uncertain variables with different dynamic patterns and included 100 realizations of the considered uncertainty in the evaluation to better catch the probability distribution of the control performance. The evaluation results suggest that deterministic load scheduling can reduce the operating energy cost by 18% but its performance can be affected by uncertainty. Stochastic load scheduling can further decrease the operating energy cost under uncertainty compared to deterministic load scheduling. We also found that the effectiveness of stochastic load scheduling in handling uncertainty is not directly associated with the number of uncertainty scenarios that are considered in its formulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Delivering Clean Air in Denver: Propane Trucks and Infrastructure in Mail Delivery Application

In 2021, Drive Clean Colorado, a Denver-based Clean Cities coalition, initiated the deployment of five Class 6 medium-duty propane autogas delivery trucks into a United States Postal Service (USPS) mail delivery contractor fleet with the goal of providing a proof-of-concept demonstration for mail delivery fleets nationwide. Funded by the U.S. Department of Energy's Office of Energy Efficiency & Renewable Energy, the project, titled "Delivering Clean Air in Denver: Propane Trucks and Infrastructure in Mail Delivery Application," enabled the purchase and deployment of the propane-powered trucks, refueling infrastructure, and supporting analysis by the National Renewable Energy Laboratory (NREL). Key objectives of the analysis included calculating the propane vehicles' emissions reductions, analyzing the costs and operational performance of the propane fleet compared to conventional diesel-powered vehicles, and evaluating the viability of propane as a clean and cost-effective alternative to conventional diesel trucks (AFDC 2023b, 2023c). The primary goal of the project was to demonstrate alternative fuel vehicles in a mail transport application and evaluate the viability of propane as a clean and cost-effective alternative to conventional diesel trucks. This proof-of-concept demonstration is expected to lead to improved understanding of the performance attributes, costs, and operational issues to inform technology adoption decisions, helping to spur market transformation toward lower-emission truck fleets. By reducing the risk of first adoption, potential exists to transform the U.S. Postal Service (USPS) mail delivery system into a lower-carbon national fleet. This technical report details the vehicle duty cycle characterization and fleet cost and performance comparison performed by the National Renewable Energy Laboratory, in addition to estimated emissions reductions for delivery operations.

33 ADVANCED PROPULSION SYSTEMS↗

Risk Analysis for Remote Operation of Microreactors

Microreactors are a subset of advanced nuclear reactors that can be factory fabricated, transportable, and self-regulating. They have the potential to be used in microgrids, rural and remote areas, or emergency response applications, replacing fossil fuel sources like diesel generators and enabling sustainable energy generation. In order to make microreactor operation cost-effective, it is likely that remote communications will be needed to reduce the number of personnel required to be on site. While remote operation of energy generation and other industrial control systems is common in other industries, it is not yet adopted in the nuclear community and has many perceived and actual risks. In this paper, the severity of the risks introduced by remote operations for microreactors are explored. The primary changes in the operations involve the addition of a remote communications network and a certification system for data and controls. These changes lend themselves to considerations of cyber risks, whether unintentional or adversarial, but the assessment considers not just cyber risks introduced, but also how physical and human factors-based risks will impact the remote operations system and change the overall risk profile. This initial assessment indicates that there are standard cyber and mitigation measures that can be put in place so the risk of doing remote operations does not dramatically increase compared to local operations. This evaluation is a critical step in the process of evaluating if remote operations of microreactors is a suitable solution to meet future sustainable grid needs

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Levelized Cost of Electricity (LCOE) Content Model for Design of High Deflection Foils for MHK Applications

The LCOE Content Model provides data submitters with an easy and consistent means of uploading data that can be used to calculate the levelized cost of energy for MHK devices. These data are important to DOE and will be used to develop data products that provide quantitative information to guide and support programmatic decisions. Data will also be used to evaluate MHK products and determine costs and can help data users compare the combination of capital costs and operations and maintenance over time. The ultimate goal is to use these data to perform research and tailor programs to best benefit the industry.

16 TIDAL AND WAVE POWER↗

Enhancement of Optical Efficiency of CSP Mirrors for Reducing O&M Cost via Near-Continuous Operation of Self-Cleaning Electrodynamic Screens (EDS). Final Report

Over the past decade, techno-economical advancements in solar energy systems, particularly the improvement in the conversion efficiency of PV modules made with mono-crystalline silicon solar cells from 12% to 20%, as well as the cost reduction in manufacturing by a factor of about 10%, have made it possible to achieve a levelized cost of electricity (LCOE) in PV plants that is comparable to, or less than, the cost of deriving electricity from fossil fuels. Operating PV plants in mid-latitude sun-belt regions, where the solar irradiance level is highest, provides a high annual energy-yield (kWh/kWp) due to two factors: (1) the availability of predictable high solar irradiance throughout the year with the fewest interruptions in solar flux from clouds and rain, and (2) the increased conversion efficiency of crystalline solar cells, as recombination loss has decreased with increased intensity of the sunlight that illuminates the silicon solar cells. Semi-arid and desert regions, however, are plagued by high atmospheric dust concentrations and frequent sand storms. The deposition of a layer of dust on the optical surfaces of solar collectors such as PV modules and concentrating mirrors reduces the transmission efficiency of sunlight that actually reaches the solar cells or receivers, resulting in high energy-yield soiling loss. There are two major cost components to operating a solar plant: (1) installation costs, and (2) operation-and-maintenance (O&M) costs. There is no fuel cost; hence operating a solar plant in a semi-arid or desert region provides high returns on investment if soiling losses are mitigated via efficient cleaning methods and optimized cleaning frequency. If solar collectors are not cleaned, the accumulation of dust layers on solar collectors may cause the operation of such plants in arid regions to become economically unviable. Washing solar collectors with water and detergent, as is most commonly done now, is an efficient method for cleaning. The conventional approach in utility-scale solar plants is to use a large truck with a water tank and pump system for spraying deionized water on the surface of the solar collectors. Robotic cleaning with brushes, used for many solar plants, requires lesser water for cleaning. The water consumed using semi-automated cleaning of PV modules in utility-scale solar plants is approximately 2 liters/m 2 per cleaning cycle. The total optical surface area of the solar collectors in 1 TW-scale solar installation will be more than 3 × 109 m 2 ; hence an enormous amount of water be needed for cleaning. There simply is not enough fresh water in the sun-belt areas of the world for predicted cleaning needs. In solar power plants, the estimated cost of cleaning solar collectors includes expenses related to the equipment used, labor, cost of transportation of water, the energy required for cleaning, plus ancillary costs whereas the cost of water is not considered. The water used is obtained from sources located close to plant sites, unmindful of the environmental and societal impact as the power plants are oftentimes located in regions that face severe drought. This practice is very similar to the cost calculations in deriving the levelized cost of electricity (LCOE) in conventional power plants based on burning fossil fuel such as coal and gas, while disregarding the cost of climate change and health effects. Unless a water-free or low-water cleaning method is established, the expansion of solar plants may lose public support in areas suffering long intervals of drought. The goal of this research project has been the development and application of the Electrodynamic Screen (EDS) as a means for a water-free, scalable cleaning process applicable to solar-power installations, including rooftop applications. We describe here the development of an EDS film-based cleaning process as an emerging method for use on PV modules, parabolic troughs, and heliostats. This report aims to show the feasibility of integrating or retrofitting EDS films onto the optical surfaces of solar collectors (both PV and CSP) while maintaining high transmission or reflection efficiency. The cleaning action provided by the EDS film is an active method to remove dust deposits by electrodynamic force. Current lab-scale prototype EDS films, retrofitted onto solar panels and mirrors, have shown to be capable of maintaining optical transmission or specular-reflection efficiencies higher than 90% of initial values under clean conditions. The optical surfaces of solar collectors laminated with EDS films can remove more than 90% of deposited dust when the EDS is activated for less than two minutes. As an electrodynamic dust removal process, the EDS film-based method is designed primarily for the removal of dust in solar installations located in semi-arid and desert areas, where the atmosphere is often dry and dusty and rainfall is infrequent. While EDS film application minimizes water consumption and facilitates cleaning as frequently as needed, it has limitations in removing contaminants such as soot, organic pollutants deposited as fine films on the surface, and bird droppings. The dust removal efficiency of the EDS is maximum at relative humidity RH is 40 to 50% and decreases at when RH > 65%. Many solar plant sites undergo diurnal and seasonal cycles of high ambient, early afternoon temperatures and an RH that reaches the dew point early in the morning. These variations in atmospheric conditions do not limit the operation of the EDS film. This report presents a brief review of the progress and the potential of EDS film technology for mitigating the impact of dust on solar collectors via water-free cleaning, as well as current technical challenges regarding efficiency and durability. Our experimental data on the performance of EDS films show that: (1) the dust-removal efficiency (DRE) can reach levels higher than 90%, (2) the specular reflectivity (SR) of EDS film-laminated second-surface mirrors reach levels in excess of 90%, (3) the specular reflectivity restoration (SRR) can exceed 90%, (4) the output-power restoration (OPR) of PV modules can exceed 95%, and (5) the optical transmission efficiency (TE) of the EDS films can be greater than 90%. Working with Sandia National Laboratories (NM), Corning Research and Development Corporation (NY), Eastman Kodak (NY), Tomark-Worthen Industries (NH), and EDS Chile SPA (Chile), we have produced EDS film-laminated PV modules and demonstrated their self-cleaning functions without requiring water. We have demonstrated that the operational range of EDS films will cover the expected ambient temperature of solar fields at RH cycling varying from 20 to 95% as long as the EDS films are activated in the RH range 20 to 50%. (Typical solar-field climates in deserts and semi-arid lands often reach near dew point in coastal areas.) Our experiments on the application of hydrophobic-fluorinated nanoparticle coatings on EDS film surfaces show that the EDS operational range can be extended to higher RH levels that approach the dew point. At Eastman Kodak, as one of our industrial partners, we were able to establish a process for manufacturing EDS films using flexographic printing of the electrodes onto transparent polymer films. This process utilizes an existing manufacturing line at Eastman Kodak that allows fabrication of medium-scale EDS films (26 cm × 30 cm). The manufacturing process has the capacity to produce EDS films at high production speeds. The medium-scale EDS films that have been printed at Kodak were evaluated in the lab at Boston University. The EDS films produced at Kodak were laminated at Tomark-Worthen using an industrial scale vacuum laminator to produce EDS film stacks, which can be affixed onto the optical surfaces of PV modules or concentrating mirrors. The EDS film stack consists of the EDS films that have Willow® Glass (WG) which has a thickness of 100 μm as the front surface. The WG sheets obtained from Corning Research and Development Corporation are customized in size and shape to cover the active area of the EDS films. The back surface of the EDS film stack is integrated onto the optical surface of the solar panel or mirror using optically clear adhesive (OCA) films or silicone adhesives. The OCA films (thickness 25 μm) are produced by 3M. The EDS film stacks have the architecture: WG/OCA/EDS Film/OCA/ over PV module or solar mirror. The power-supply units needed for activating the electrodes of the EDS film were designed and produced at Boston University. These power supply units provide three-phase, 1.2 kV voltage pulses at a very low current (micro-ampere) level and at a low frequency (≈ 5 Hz). The voltage pulses are applied to the electrodes in a sequence such that the train of pulses resembles a unidirectional traveling wave of electrical field on the surface of the EDS film. The dust particles on the surface become charged electrostatically and are levitated by the Coulomb force. The lateral sweeping action of the traveling electric field created by the three-phase voltages pulses then sweeps the dust off the surface. The energy consumed by the EDS electrodes is less than 0.2 Wh/m 2 /cleaning cycle, enabling energy-efficient restoration of output power (OPR) of PV module or specular reflectivity restoration (SRR) for solar mirrors. The EDS system consists of (1) an EDS film stack laminated onto the solar collectors, (2) connection of the EDS film to its power supply unit and (3) Interconnection of the power supply to PV modules or solar mirrors. Design, construction and assessment of field-testing units that have EDS stack laminated PV modules for evaluating the performance of the EDS films in solar fields is being carried out at BU. Our progress under this project, aimed at the advancement of EDS film technology, has reached DOE Technology Readiness Level (TRL) 6. Based on the extensive laboratory evaluations and limited field trials, as well as contacts with potential users, we believe that the technology has reached its commercial stage. We are conducting a cost analysis using the National Renewable Energy Laboratory (NREL) System Advisory Model (SAM) and are preparing for field trials of EDS films in different solar fields in the US, Chile, India and in the Middle East. A brief description of EDS film performance, construction and testing of the field-test unit, autonomous operation of the field-test unit for evaluating EDS performance in increasing energy yield, associated revenue savings, and water conservation is presented.

14 SOLAR ENERGY↗

Explainable Artificial Intelligence Technology for Predictive Maintenance

The domestic nuclear power plant fleet has relied on labor-intensive and time-consuming preventive maintenance programs, thus driving up operation and maintenance costs to achieve high-capacity factors. Artificial intelligence and machine learning can help simplify complex problems, such as diagnosing equipment degradation, to enable more effective decision-making. Benefits will be felt not only within existing analog and digital instrumentation and control, but also work processes, the integration of people with technology, and most importantly, the business case. Together, these hold promise to make nuclear power more efficient and reduce costs associated with operation and maintenance. While the artificial intelligence and machine learning technologies hold significant promise in the nuclear industry, there are challenges or barriers to their adoption. This report outlines the those different machine learning adoption barriers (categorized as historical, technical, economic, regulatory, and user) that the industry must overcome to realize the full benefits of artificial intelligence and machine learning capabilities for long-term economic sustainability. This report also provides solutions for some of these barriers by focusing on improving the explainability of machine learning to encourage trust from the end-user. Trust and explainability are essential to machine learning adoption. This report focuses on research-developed solutions to some of these barriers while analyzing a non-safety-related system, namely the circulating water system. This system frequently experiences waterbox fouling which our models preemptively diagnoses then explains to the operator how those conclusions were reached. This report presents and discusses the inherent trade-off between machine learning performance (in terms of accuracy) and explainability, where highly accurate machine learning methods (such as deep-learning) are the least explainable, and the most explainable methods (such as decision trees) are the least accurate. In addition, explainability of artificial intelligence techniques in terms of transparency and post-hoc metrics are discussed. This report outlines the importance of data novelty and value of new information in evaluating both the explainability and trustworthiness. Novelty detection helps to establish consistency or inconsistency of the new data with respect to the training data. On the other hand, value of information could be a part of the user-centric visualization recommendation system that request additional information to be collected, thereby strengthening the machine learning outcomes. During this project, a copyrighted user-centric visualization that aligns with a human-in-the-loop approach was developed. The user-centric visualization presents different levels of information and can be tailored as per user credentials to gain user confidence. One of the salient features of the user-centric visualization is it presents machine learning methods with explainability metrics. A simplified version of the user-centric visualization was presented to 32 users with varying levels of machine learning expertise. Feedback was solicited to test the hypothesis that the app contained sufficient explainability and that the users would trust the algorithm. Overall, the app was positively received, and the hypothesis was supported. This report discusses the trust-but-verify framework – a potential approach to build user trust artificial intelligence. The framework discusses trust from the human level to artificial intelligence level. The fundamental premise of the trust but verify framework is derived from an observation of nuclear safety culture (i.e., nuclear power plant personnel do not rely on a singular source of data to make a decision). This also ties back to the user-centric visualization that presents different levels of information to achieve both explainability and trustworthiness of artificial intelligence. Even so, the adoption of artificial intelligence and machine learning in the nuclear industry faces additional barriers, namely regulatory and stakeholder readiness. To overcome these challenges, new solutions must gain regulatory approval and cater to stakeholder needs. The Nuclear Regulatory Committee has a 5-year strategic plan which prepares them for reviewing artificial intelligence technologies in licensee submissions. Early and frequent engagement with the regulator is encouraged. Additionally, artificial intelligence solutions should incorporate human-in-the-loop considerations and offer explainability. Stakeholders must prepare by hiring or training staff to adapt to advancing technology in everyday plant tasks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Powertrain Performance and Total Cost of Ownership Analysis for Class 8 Yard Tractors and Refuse Trucks

Advanced powertrain technologies, specifically fuel cell electric powertrains, have gained attention as viable alternatives for medium- and heavy-duty (M/HD) vehicles. However, it is unclear how these alternative powertrain vehicles stack up against their diesel counterparts in terms of performance and total cost of ownership (TCO). Furthermore, there are vehicle segments within the M/HD sector that have remained unstudied for fuel cell electric applications. This analysis aims to provide a comparative scoping-level TCO and performance analysis for two heavy-duty vocation vehicles (Class 8 U.S. port-side yard tractor and Class 8 U.S.-based refuse truck) for both conventional diesel and heavy-duty fuel cell electric (HDFC) powertrains. The refuse truck analysis also considered compressed natural gas powertrains (CNG) for comparison. The analysis includes seven timeframes (2020, 2025, 2030, 2035, 2040, 2045, and 2050) for comparison. This simplified TCO analysis includes only direct costs (fuel price, glider purchase price, and operating & maintenance costs) and excludes any associated indirect cost (e.g., dwell time costs and other opportunity based costs). Representative drive cycles for each vehicle were based on on-board GPS logged data and chosen by the analysis team to represent average, non-extreme driving conditions. At the time the analysis was performed, the Inflation Reduction Act was not in effect and therefore any potential subsidies and future cost reductions enacted under the Inflation Reduction Act were not included. Based on the operational setpoints used in this analysis, HDFC powertrains for both yard tractors and refuse trucks have the potential to achieve TCO advantages over conventional diesel powertrains (and CNG for refuse truck applications) in the near- to mid-term future while meeting the necessary duty cycle performance requirements. Yard tractors and refuse trucks spend a significant amount of time operating at low speeds, with long durations of idling, and experience numerous start/stop occurrences. These operational characteristics favor fuel cell performance as fuel cells operate with higher efficiencies at lower percentages of total power output. Conversely, conventional diesel and CNG engines are most efficient at higher percentages of total power output. This helps HDFC powered yard tractors and refuse trucks realize improved fuel economy when compared to their diesel counterparts, which helps reduce total fuel costs and therefore, total TCO. The analysis demonstrates that fuel prices play a significant role in determining TCO for each vehicle and should remain an R&D focus area. Overall, under the analysis' specified conditions, HDFC yard tractors have the potential to achieve cost parity with diesel yard tractors as early as 2025. For refuse trucks, HDFC refuse trucks have the potential to achieve cost parity with diesel and CNG refuse trucks in 2030 and 2040, respectively.

33 ADVANCED PROPULSION SYSTEMS↗