Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “monitoring system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Online and Offline Identification of False Data Injection Attacks in Battery Sensors Using a Single Particle Model

The cells in battery energy storage systems are monitored, protected, and controlled by battery management systems whose sensors are susceptible to cyberattacks. False data injection attacks (FDIAs) targeting batteries’ voltage sensors affect cell protection functions and the estimation of critical battery states like the state of charge (SoC). Inaccurate SoC estimation could result in battery overcharging and over discharging, which can have disastrous consequences on grid operations. This paper proposes a three-pronged online and offline method to detect, identify, and classify FDIAs corrupting the voltage sensors of a battery stack. To accurately model the dynamics of the series-connected cells a single particle model is used and to estimate the SoC, the unscented Kalman filter is employed. FDIA detection, identification, and classification was accomplished using a tuned cumulative sum (CUSUM) algorithm, which was compared with a baseline method, the chi-squared error detector. Online simulations and offline batch simulations were performed to determine the effectiveness of the proposed approach. Throughout the batch simulations, the CUSUM algorithm detected attacks, with no false positives, in 99.83% of cases, identified the corrupted sensor in 97% of cases, and determined if the attack was positively or negatively biased in 97% of cases.

25 ENERGY STORAGE↗

Representing Complex Systems as Graphs for Debugging and Predictive Maintenance-Preliminary Thoughts

Representing complex systems as graphs enables use of mathematical tools to identify faults or predict failures. Graph nodes correspond to individual modules or subsystems, and edges link coupled system parts. ‘Probes’ measure the node outputs, monitoring the system health for unexpected behavior. Assuming one cannot probe every point, within a system, the fault correlates to a region—not necessarily the specific location. Bayesian networks trained to understand fault patterns can accurately identify the source. The diagnostic tool described aides debugging by pinpointing system failure causes. For predictive maintenance, probe data develop probability distribution functions describing subsystem mean time to failure. Unit lifetime can be estimated through these probability distributions. Two approaches include using Bayesian classifiers to infer the system failure source and developing maintenance schedules by treating systems as collections of random variables. When failure behavior does not follow a closed form function, use of similarity models is proposed.

97 MATHEMATICS AND COMPUTING↗

Non-invasive, in situ diagnosis and monitoring of corrosion in high temperature systems

Techniques for non-invasive diagnosis and/or monitoring of corrosion in high temperature systems using specialized sensors that produce multi-mode acoustic signals in situ for accurate determination of wall loss and/or physical property changes for a vessel in contact with a high temperature, highly corrosive substance are disclosed. Sensitivity of a few microns (or about 0.1%) of wall loss, detection of changes in physical properties of vessel contents (e.g., approximately 1%), or both, at temperatures of 500° C., 600° C., or higher may be realized. Corrosion may be identified and/or monitored using time domain, frequency domain, or mixed time domain and frequency domain analysis of signal characteristics, signal delay, or both, for relatively short circumferential acoustic wave propagation (e.g., a few inches), as well as relatively long axial acoustic wave propagation (e.g., tens of feet).

Findikoglu, Alp Tugrul↗

Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE VTO funded project DE- EE0008451, where ABB Inc. (ABB), in collaboration with Idaho National Laboratory (INL), APS Global (APS), and XOS Trucks (XOS) pursued the development of a cyber-resilient extreme fast charging (XFC) management system. This project entitled Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) focuses on a resilient architecture for smart charging EV Supply Equipment (EVSE) device control and Coordinated Anomaly Detection System (CADS) features that can be added at the charging site depot level to increase cybersecurity. The project was split into two budget periods focused first on developing the threat model and resilient control concepts and second on testing, improving, and validating those developed resilient control algorithms and features with a focus on key vulnerabilities identified during the threat assessment portion of the project. During the first budget period of the CyberX project, the ABB led team focused on activities to identify, model, and quantitatively prioritize high-impact attack scenarios with potential cyber-physical effects while also modeling and developing concepts for a resilient control system that could securely address integration of DERs and other resources with EV charging. Development of the security focused XFC management system (XMS) was accomplished first by offline simulation using a developed XFC station or depot with 480V input level and simulating measurement inputs to monitoring and control systems in concept development. A representative distribution grid model was developed supporting an EV charging site model with BESS and 6 general EV charging models. These EV charging models allowed multiple configurations of charging level, multiple connected protection and measurement devices, and simulation function to show general compromise of EV, BESS, and protection features based on parallel threat analysis. During the second budget period, the EV site and supporting systems model was developed in more detail and converted from offline model to real-time to real-time with EV charging hardware in the loop (HIL). The resilient control architecture developed as concept in the first part of the project was further tested and validated for integration of local energy resources and XFC charging station site equipment while maintaining cybersecure operating principles. The proposed resilient architecture for smart charging and cybersecurity features consists of two main concepts developed and tested within the project. The first concept is an XFC management system (XMS) consisting of a hardware gateway, software platform, and Supervisory Control and Data Acquisition (SCADA) or Distribution Management System integration components. The second concept is a Coordinated Anomaly Detection System (CADS) which forms a primarily software-related subsystem of the total CyberX solution focused on monitoring system measurements, estimation of measurement states, and predicting current at the utility point of interaction based on machine learning for anomaly detection.

33 ADVANCED PROPULSION SYSTEMS↗

From pixels to patterns: Coupling Optical Coherence Tomography and machine learning for monitoring coastal wetland root systems

Coastal wetlands are crucial in shoreline stabilization, carbon sequestration, and storm protection. Yet, due to limitations in traditional destructive sampling techniques, the belowground biomass (live root mass) and necromass (dead and decaying roots) remain difficult to assess in coastal wetlands, limiting our understanding on coastal resilience, nutrient cycling, and soil structure. This study employs Optical Coherence Tomography (OCT) as a high-resolution imaging technique to analyze root biomass and necromass in the Terrebonne Basin, Louisiana. A Random Forest (RF) model was developed to classify root health states based on OCT-derived features, achieving an accuracy of 70% in distinguishing live from dead root segments. The results demonstrate that OCT, combined with ML, offers a promising novel approach to root analysis, providing fine-scale insights into root morphology and decay patterns that are not easily captured by conventional methods. This research lays the foundation for future integration of OCT with complementary imaging modalities such as X-ray Computed Tomography (XCT) and advanced ML algorithms to enhance classification accuracy and scalability. Future work aims to expand the dataset diversity across different wetland types and apply the methodology for large-scale, repeatable assessments of root biomass turnover and accumulation, with important implications for wetland monitoring, conservation, and restoration under changing environmental conditions.

AI/ML↗

Deep Neural Network Assisted Distributed Strain and Temperature Fiber Sensor System for Natural Gas Pipeline Monitoring

Natural gas pipeline integrity monitoring is crucial to detect potential leaks, find structural issues, and prevent environmental damage. This article presents a system of natural gas pipeline monitoring that uses a specialized double Brillouin peak sensing fiber along with the Brillouin optical time domain analysis (BOTDAs) technique. The calibrated sensing fiber coefficients for strain and temperature are 41.8 kHz/ με and 0.9 MHz/°C for peak 1; and 47.2 kHz/ με , and 1.11 MHz/°C for peak 2, respectively. Initially, lab tests were performed by installing a short section of double Brillouin peak fiber (DBPF) on a 1-in steel pipe under pressure up to 1000 per square inch (psi) at elevated temperatures. Simultaneous distributed measurements of temperature and pressure-induced hoop strain were successfully measured. Considering the long processing speed to extract Brillouin frequency shift (BFS), we employ a novel probabilistic deep neural network (PDNN) framework for rapid BFS prediction. Additionally, using the Finite Element Method, the effects of the pipeline pressure on hoop strain were modeled and compared to the experimental hoop strain under the same set of pipeline conditions. Finally, an actual 4-in outer diameter steel natural gas pipeline was used for pilot-scale tests, where hoop strain was measured at various pressure levels. Leaks were simulated to demonstrate accurate pipeline integrity monitoring. At an internal pipe pressure of 1000 psi, hoop strain of approximately 300 με was observed, and the sensitivity was calculated as 0.28 με /psi. The results of this pilot-scale study demonstrated that the system is capable of performing distributed monitoring sufficient to detect pipeline pressure and the presence of leaks to ensure the safe operation of gas pipelines in the field.

03 NATURAL GAS↗

Development of a field-deployable qPCR assay for real-time pest monitoring in algal cultivation systems

Outdoor cultivation is commonly used to produce algal biomass for a variety of bioproducts including food, feed, fuel, pharmaceuticals, and nutraceuticals. Outdoor cultivation ponds are highly susceptible to pest pressures that may lead to periods of low productivity or even entire loss of the algal crop. Consequently, there is a need for rapid, real-time tracking of pests for early intervention to mitigate crop loss. In this work, we describe the development of a field deployable, low-cost qPCR assay for detecting both known and novel pests of a farmed eukaryotic alga species, Nannochloropsis sp. We performed a proximity guided metagenome deconvolution approach (ProxiMeta™) to discover novel pests that temporally correspond to periods of reduced pond productivity. This approach provided high-quality metagenome assemblies that were used to design qPCR probes to detect specific pests of interest. The portable qPCR assay, designed to be deployed at remote field locations, enables low-cost surveillance with a rapid (2 h) turn-around time. Frequent sampling allows for early detection and prompts intervention strategies to remedy infected ponds to minimize crop loss. The qPCR assay was used to successfully detect a known predatory bacterium within the order Bdellovibrionales both in the lab and at a remote field location. Furthermore, we assembled the genome of two novel, site-specific pests in the Saprospiraceae family and successfully designed qPCR probes that differentially detected their presence in two different pond locations. Ultimately, this assay has the potential to monitor multiple pests simultaneously and tailor targets to match likely pest infections that differ across geographical locations, helping to mitigate crop loss on a large scale.

59 BASIC BIOLOGICAL SCIENCES↗

Noncontact Monitoring of Overhead Transmission Lines Using Space Potential Phasor Measurements

Power system reliability requirements necessitate the development of measurement systems to monitor the operational state of critical transmission lines. Here in this article, a novel noncontact method for monitoring overhead transmission lines is proposed. The method is based on measuring the amplitude and relative phase of the transmission line's space potential at two or more strategically located points in space along with the use of passive phase shifters to enhance the sensitivity of the measurements. Applications of voltage unbalance and conductor sag measurements are demonstrated along with the results of conductor sag measurements on an operating 230-kV transmission line. It is shown that using enhanced relative phase measurements can significantly improve the sensitivity of the measurements.

47 OTHER INSTRUMENTATION↗

A robust dynamic state estimation approach against model errors caused by load changes

Dynamic state estimation (DSE) plays an important role in power system security monitoring and online control. In practice, there are two approaches to implementing DSE. The first approach is distributed DSE, which is based on the assumption that the terminal bus of each generator can be measured by PMUs (phasor measurement units). The assumption cannot be satisfied currently, however, because PMUs usually are installed at important high-voltage buses such as 500-kV buses installed in portions of the grid overseen by the Western Electricity Coordinating Council. Another issue of this approach is that performance of DSE is vulnerable to bad measurement data. The reason for this vulnerability is that DSE is performed separately through measurements at each terminal bus, and measurements at terminal buses are the only measurement upon which DSE can rely. Therefore, important redundant measurements are not included in this approach. The second approach is centralized DSE. This approach does not have the requirement for PMU location, and redundant measurements can be considered fully. However, load changes and grid topology changes impact centralized DSE. In this paper, we propose a new approach for handling the impact of load changes on DSE. We have developed a new algorithm that includes two sequential steps. In the first step, errors caused by load changes are detected by analyzing the difference between prediction results and measured results. In the second step, once model error is detected, a model optimization procedure is run to correct the error so the state estimation error can be mitigated. Simulation results from the IEEE 68 bus system show that the proposed approach can effectively handle model errors caused by load changes.

robust dynamic state estimation, load change, powe↗

Predicting melt pool depth and grain length using multiple signatures from in-situ single camera two-wavelength imaging pyrometry for laser powder bed fusion

In laser powder bed fusion (LPBF), the in-situ process signatures are known to have a direct correlation with the microstructural properties of the solidified melt pool (MP). It is known that the MP cooling and heating rates, and laser processing parameters can critically determine the grain structure and thereby affect the part properties. The objective of this work is to study the feasibility of using in-process, high-speed imaging pyrometry for evaluating the solidified MP properties “below” the surface, such as depth and microstructural properties. To accomplish this, we employ an in-house single camera-based two-wavelength imaging pyrometry (STWIP) system for monitoring the printing of single-scan tracks with Inconel 718 on a commercial LPBF printer (EOS M290). Further, the lab designed STWIP system is a coaxial high-speed (>10,000 fps) imaging system capable of monitoring MP temperature, morphology, and intensity profiles. The temperature measurements from STWIP are emissivity independent. The STWIP measured MP signatures of the printed tracks are correlated with the ex-situ microscopy characterized MP depth and the average grain lengths. From the data analysis, using support vector machine (SVM)-based regression models, we found that the MP temperature signatures are crucial for an accurate prediction of MP depth and the grain length, thus validating the novelty and necessity of the developed in-situ monitoring methods and analysis.

36 MATERIALS SCIENCE↗

Control System Upgrade for Battery State-of-Charge Indications

The Advanced Test Reactor (ATR) Complex at Idaho National Laboratory (INL) relies on Battery Backed Power (BBP) systems and Uninterruptible Power Supplies (UPS) to ensure continuous power supply to critical components. This project aims to enhance the reliability and functionality of the battery monitoring and control systems by updating the State-of-Charge (SOC) system, Programmable Logic Controller (PLC), and Human-Machine Interface (HMI) for the nuclear safety-related battery banks. The current system, while functional, has areas for improvement, particularly in recharging calculations and alarm functions. The project objectives include developing flow charts, programming the new PLC and HMI, conducting bench tests, and updating design documentation. Additionally, the project ensures compliance with safety standards, develops training materials, creates comprehensive documentation, and integrates seamlessly with existing ATR infrastructure. The new SOC system is designed to be scalable for future upgrades, improve efficiency, enhance data accuracy, implement redundancy features, and achieve project goals within budget constraints while considering environmental impact. The methodology involved familiarizing with BBP and UPS systems, collecting current readings, rescaling signals, learning ladder logic, and updating the HMI. The transition from SLC 5/03 PLC using RS Logix 500 to CompactLogix 5380 using Studio 5000 was a key step. Despite challenges in transferring outdated PLC ladder logic and HMI code, starting from scratch led to a more accurate and efficient monitoring system, contributing to improved safety and operational efficiency. The project is currently awaiting approval of the Engineering Calculation and Analysis Report (ECAR) before implementation.

42 - ENGINEERING↗

Low-cost embedded optical sensing systems for distribution transformer monitoring

There is a mounting need for low-cost monitoring with online sensing technologies to maintain grid reliability and uptime. Here we introduce an innovative low-cost, embedded optical sensing technology initially focused on transformers that was developed and demonstrated at a major electric utility, Con Edison. A version of it that can be retrofitted onto existing transformers in the field was also developed. Two new 500 kVA distribution network transformers were built with embedded fiber-optic (FO) sensors and qualified per industry standards. Vibration, temperature, and corrosion were key parameters monitored. The first transformer with embedded FO sensors was installed at a Con Edison facility and monitored at our team’s office. The second one was installed in an urban street-side underground location with online data processing/feature extraction algorithms and monitored through a wireless router. Additionally, an older transformer was also retrofitted. Data analysis was done on these transformers showing promising correlations with their corresponding loading cycles. Furthermore, key events such as the transformer primary-side energizing, and other events were detected. In general, the technology was demonstrated over 6 months across the 3 transformers instrumented with promising results. Thus, it has the potential to enable predictive maintenance for transformers and other grid assets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Open-Source Ambient-Signal-Based Inertia Monitoring Tool for Power systems [SWR-25-59]

This script, developed by NREL, implements an inertia estimation algorithm using a sliding window approach. The inertia (H) is estimated based on frequency deviations and active power deviations, utilizing the swing equation from power system dynamics. An example application is provided using the WECC 240-bus system.

Peng, Jiangkai [National Renewable Energy Laborato↗