Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Plastic deformation at surface during unlubricated sliding

The plastic deformation and wear of 304 stainless-steel surface slid against an aluminum oxide rider were observed by using a scanning electron microscope and an optical microscope. Experiments were conducted in a vacuum of 0.000001 Pa and in an environment of 0.0005 Pa chlorine gas at 25 C. The load was 500 grams and the sliding velocity was 0.5 centimeter per second. The deformed surface layer which accumulates and develops successively is left behind the rider, and step-shaped protuberances are developed even after single pass sliding under both environmental conditions. A fully developed surface layer is gradually torn off leaving a characteristic pattern. These observations result from both adhesion and an adhesive wear mechanism.

Yamamoto, T.↗

Planetary exploration sensor systems

Most of the instruments that have been used in planetary exploration have been either spectrometers or imaging devices. Instruments of these types are being developed for the Galileo and VOIR (Venus Orbiting Imaging Radar) missions. Galileo will take advantage of new CCD (charge-coupled device) technology, and VOIR will use techniques of synthetic aperture radar developed for Seasat. For determining the macrostructure of mineral resources, the best approach is believed to involve acoustic imaging, essentially a seismic data processing technique. Determinations of microstructure would require a light microscope and an electron microscope. For determining the nature and form of volatiles, a differential scanning calorimeter could be used. To determine the mineral composition, an electron beam microprobe with X-ray fluorescence and spectroscopy would be used.

Saunders, R. S.↗

Microchondrule-bearing clast in the Piancaldoli LL3 meteorite - A new kind of type 3 chondrite and its relevance to the history of chondrules

Electron microprobe, scanning electron microscope, and petrographic analyses of the microchondritic clast of the Piancaldoli LL3 chondrite are reported and compared with other type three chondrites. The clast, like other type three chondrites, has a fine-grained Fe-rich opaque silicate matrix, sharply defined chondrules, abundant low-Ca clinopyroxene and minor troilite and Si and Cr-bearing metallic Fe, Ni. However, the very high model matrix abundance, unique characteristics of the chondrules, and absence of microscopically observable olivine indicate that the clast is a new type of type three chondrite. It is concluded that the microchondrules were formed by the same process that formed normal-sized chondrules in type three chondrites: melting of preexisting dustballs. It is suggested that dust grains were mineralogically sorted in the nebula before aggregating into dustballs.

Rubin, A. E.↗

Increased hematuria following hypergravic exposure in middle-aged women

The effects of simulated weightlessness on orthostatic tolerance were studied in 9 women (55 to 65 years old) who underwent acceleration and lower body negative pressure before and after 10 days of horizontal bed rest. The results of this study show the first known association of microscopic hematuria with hypergravic and orthostatic stress which suggests similarities to the 'stress hematuria syndrome' previously seen with heavy exercise (Boileau et al., 1980). In addition, the sporadic occurrence of this phenomenon indicates a multifactorial etiology in predisposed individuals. Bedrest or weightlessness simulation per se does not seem to significantly alter renal function, but may decrease microscopic hematuria with an orthostatic component.

Goldwater, D. J.↗

Investigations into the burning-out of organic substances in the ceramic body

Pressed compacts were made of spray dried alumina containing water soluble polyvinyl alcohol or cellulose derivative binder. The burning out of organic binder on gradual heating was investigated by visual and microscopic observations of the cross section and by thermogravimetry. Burning out proceeds inward from the peripheries, gradually reducing the size of the black core, which first consists of a dark boundary layer and later turns uniformly black with a sharp boundary. A detailed mechanism of the burning out process between and within the spray dried granules is observed under the microscope. Oxygen atmosphere accelerates the burning out process.

Locher, C.↗

Metallurgical characterization of the fracture of several high strength aluminum alloys

The fracture behavior for structural aluminum alloys (2024, 6061, 7075, and 7178) was examined in selected heat treatments. The investigation included tensile, shear, and precracked notch-bend specimens fractured at ambient temperature under monotonic loading. Specimens were obtained from thin sheets and thick plates and were tested in longitudinal and transverse orientations at different strain rates. Microstructures of alloys were examined using the optical microscope and the scanning electron microscope with associated energy dispersive X ray chemical analysis. Several different types of second phase particles, some not reported by other investigators, were identified in the alloys. Fracture morphology was related to microstructural variables, test variables, and type of commercial product. Specimen orientation examined in the present investigation had little effect on fracture morphology. Test strain rate changes resulted in some change in shear fracture morphology, but not in fracture morphology of tensile specimens.

Bhandarkar, M. D.↗

Topological reaction rate measurements related to scoffing

A ball-on-plate (both consisting of hardened M-50 steel) sliding elastohydrodynamic contact was run with trimethylolpropane triheptanoate (TMPTH) with and without tricresyl phosphate (TCP). The contact area of the plate was optically profiled with a phase-locked interference microscope (PLIM) both before and after exposure to alcoholic hydrochloric acid. As scuffing was approached, the profile within the contact region changed more rapidly after the acid treatment; after scuffing, it assumed a constant high value. A metallurgical phase found in the scuff mark was apparently responsible for the high reactivity. The microscopic profile changes (sensitivity, + or - 3 nm (+ or - A) in depth) involved primarily the small asperities (radius, 3 microns); the larger ones were unaffected. Soaking the steel in TCP smoothed the fine structure of the surface profile but increased its reactivity toward alcoholic hydrochloric acid before sliding was started. Thus it would appear that PLIM examination could be used for screening potentially scuff-resistant materials.

Lauer, J. L.↗

Cellular localization of Na(+), K(+)-ATPase in the mammalian vestibular system

Two different, but complementary, procedures for cellular localization of Na+, K+-ATPase in the guinea pig vestibular system were employed. One of these techniques, devised by Stirling, depends upon the well documented ability of the specific inhibitor ouabain to bind selectively to Na+,K+-ATPase, blocking catalytic activity. Microdisected vestibular tissues are incubated with tritium-labelled (3H-) ouabain, and regions with a high concentration of Na+,K+-ATPase are subsequently identified by light microscope autoradiography. A second method, originated by Ernst, detects inorganic phosphate released from an artificial substrate (nitrophenyl phosphate) by catalytic activity of the enzyme. In the presence of strontium ion, phosphate is precipitated near regions of high activity, then converted to a product which may finally be visualized in the electron microscope. This cytochemical enzymatic reaction is inhibited by ouabain.

Kerr, T. P.↗

ECUT: Energy Conversion and Utilization Technologies program. Heterogeneous catalysis modeling program concept

Insufficient theoretical definition of heterogeneous catalysts is the major difficulty confronting industrial suppliers who seek catalyst systems which are more active, selective, and stable than those currently available. In contrast, progress was made in tailoring homogeneous catalysts to specific reactions because more is known about the reaction intermediates promoted and/or stabilized by these catalysts during the course of reaction. However, modeling heterogeneous catalysts on a microscopic scale requires compiling and verifying complex information on reaction intermediates and pathways. This can be achieved by adapting homogeneous catalyzed reaction intermediate species, applying theoretical quantum chemistry and computer technology, and developing a better understanding of heterogeneous catalyst system environments. Research in microscopic reaction modeling is now at a stage where computer modeling, supported by physical experimental verification, could provide information about the dynamics of the reactions that will lead to designing supported catalysts with improved selectivity and stability.

Voecks, G. E.↗

Fracture surface characteristics of notched angleplied graphite/epoxy composites

Composite fracture surface characteristics and related fracture modes have been investigated through extensive microscopic inspections of the fracture surfaces of notched angleplied graphite/epoxy laminates. The investigation involved 4 ply laminates of the configuration + or - theta (s) where theta = 0 deg, 3 deg, 5 deg, 10 deg, 15 deg, 30 deg, 45 deg, 60 deg, 75 deg, and 90 deg. Two-inch wide tensile specimens with 0.25 in. by 0.05 in. through-slits centered across the width were tested to fracture. The fractured surfaces were then removed and examined using a scanning electron microscope. Evaluation of the photomicrographs combined with analytical results obtained using the CODSTRAN computer code culminated in a unified set of fracture criteria for determining the mode of fracture in notched angleplied graphite/epoxy laminates.

Ginty, C. A.↗

Compression failure mechanisms in unidirectional composites

Compression failure mechanisms in unidirectional composites were examined. Possible failure modes of constituent materials are summarized and analytical models for fiber microbuckling are reviewed from a unified viewpoint. Due to deficiencies in available models, a failure model based on nonlinear properties and initial fiber curvature is proposed. The effect of constituent properties on composite compression behavior was experimentally investigated using two different graphite fibers and four different epoxy resins. The predominant microscopic scale failure mode was found to be shear crippling. In a soft resin, shear crippling was in the form of buckling of fibers on a microscopic scale. However, stiff resins failure was characterized by the formation of a kink band. For unidirectional laminates, compressive strength, and compressive modulus to a less extent, were found to increase with increasing magnitude of resin modulus. The change in compressive strength with resin modulus was predicted using the proposed nonlinear model.

Hahn, H. T.↗

Variable-Temperature-Gradient Device for Solidification Research

Device for research in solidification and crystal growth allows crystallization of melt observed as occurs. Temperature gradient across melt specimen increased or decreased rapidly while solidification front proceeds at constant speed across sample. Device moves sample at same speed, thereby holding position of liquid/solid interface stationary within field of optical microscope. Device, variabletemperature-gradient microscope stage, used to study crystal growth at constant rate while thermal driving force is varied.

Kaukler, W. F.↗

Investigation of the relations between neat resin and advanced composite mechanical properties. Volume 1: Results

A detailed evaluation of one untoughened epoxy baseline resin and three toughened epoxy resin systems was performed. The Hercules 3502, 2220-1, and 2220-3, and Ciba-Geigy Fibredux 914 resin systems were supplied in the uncured state by NASA-Langley and cast into thin flat specimens and round dogbone specimens. Tensile and torsional shear measurements were performed at three temperatures and two moisture conditions. Coefficients of thermal expansion and moisture expansion were also measured. Extensive scanning electron microscopic examination of fracture surfaces was performed, to permit the correlation of observed failure modes with the environmental conditions under which the various specimens were tested. A micromechanics analysis was used to predict the unidirectional composite response under the various test conditions, using the neat resin experimental results as the required input data. Mechanical and physical test results, the scanning electron microscope observations, and the analytical predictions were then correlated.

Zimmerman, R. S.↗

Investigation of the relations between resin and advanced composite mechanical properties. Volume 2: Appendices

One untoughened epoxy baseline resin and three toughened epoxy resin systems were evaluated. The Hercules 3502, 2220-1, and 2220-3, and Ciba-Geigy Fibredux 914 resin systems were supplied in the uncured state by NASA-Langley and cast into thin flat specimens and round dogbone specimens. Tensile and torsional shear measurements were performed at three temperatures and two moisture conditions. Coefficients of thermal expansion and moisture expansion were also measured. Extensive scanning electron microscopic examination of fracture surfaces was performed to permit the correlation of observed failure modes with the environmental conditions under which the various specimens were tested. A micromechanics analysis was used to predict the unidirectional composite response under the various test conditions, incorporating the neat resin experimental results as the required input data. The mechanical and physical test results, the scanning electron microscope observations, and the analytical predictions were then correlated.

Zimmerman, R. S.↗

Microstructures and properties of rapidly solidified alloys

The microstructure and properties of rapidly solidified aluminum alloys were researched. The effects of powder and flake chemistry and morphology and alternative consolidation processing parameters are being conducted. Samples of the powders being utilized were obtained for comprehensive metallurgical characterization. Seven aluminum alloys in the form of thin foils were studied by a variety of techniques including optical metallography, scanning electron microscope, and transmission electron microscope. Details of the microstructural characteristics are presented along with a discussion of the solidification process. A better understanding of the microstructure of the rapidly solidified aluminum alloys prepared by a variety of techniques such as roller quenching, the vacuum atomized procedure, ultrasonically atomized in inert atmospheres, and atomized in flue gas was provided.

Shechtman, D.↗

Creep fatigue life prediction for engine hot section materials (isotropic)

The Hot Section Technology (HOST) program, creep fatigue life prediction for engine hot section materials (isotropic), is reviewed. The program is aimed at improving the high temperature crack initiation life prediction technology for gas turbine hot section components. Significant results include: (1) cast B1900 and wrought IN 718 selected as the base and alternative materials respectively; (2) fatigue test specimens indicated that measurable surface cracks appear early in the specimen lives, i.e., 15% of total life at 871 C and 50% of life at 538 c; (3) observed crack initiation sites are all surface initiated and are associated with either grain boundary carbides or local porosity, transgrannular cracking is observed at the initiation site for all conditions tested; and (4) an initial evaluation of two life prediction models, representative of macroscopic (Coffin-Mason) and more microscopic (damage rate) approaches, was conducted using limited data generated at 871 C and 538 C. It is found that the microscopic approach provides a more accurate regression of the data used to determine crack initiation model constants, but overpredicts the effect of strain rate on crack initiation life for the conditions tested.

Moreno, V.↗

Topological reaction rate measurements related to scuffing

A ball-on-plate (both consisting of hardened M-50 steel) sliding elastohydrodynamic contact was run with trimethylolpropane triheptanoate (TMPTH) with and without tricresyl phosphate (TCP). The contact area of the plate was optically profiled with a phase-locked interference microscope (PLIM) both before and after exposure to alcoholic hydrochloric acid. As scuffing was approached, the profile within the contact region changed more rapidly after the acid treatment; after scuffing, it assumed a constant high value. A metallurgical phase found in the scuff mark was apparently responsible for the high reactivity. The microscopic profile changes (sensitivity, + or - 3 nm (+ or - A) in depth) involved primarily the small asperities (radius, 3 microns); the larger ones were unaffected. Soaking the steel in TCP smoothed the fine structure of the surface profile but increased its reactivity toward alcoholic hydrochloric acid before sliding was started. Thus it would appear that PLIM examination could be used for screening potentially scuff-resistant materials.

Lauer, J. L.↗

Structural Characterization and Gas Reactions of Small Metal Particles by High Resolution In-situ TEM and TED

A commercial electron microscope with flat-plate upper pole piece configuration of the objective lens and top entry specimen introduction was modified to obtain 5 x 10 to the minus 10th power mbar pressure at the site of the specimen while maintaining the convenience of a specimen airlock system that allows operation in the 10 to the 10th power mbar range within 15 minutes after specimen change. The specimen chamber contains three wire evaporation sources, a specimen heater, and facilities for oxygen or hydrogen plasma treatment to clean as-introduced specimens. Evacuation is achieved by dural differential pumping, with fine entrance and exit apertures for the electron beam. With the microscope operating at .000001 mbar, the first differential pumping stage features a high-speed cryopump operating in a stainless steel chamber that can be mildly baked and reaches 1 x 10 to the minus 8th power mbar. The second stage, containing the evaporation sources and a custom ionization gauge within 10 cm from the specimen, is a rigorously uncompromised all-metal uhv-system that is bakable to above 200 C throughout and is pumped with an 80-liter ion pump. Design operating pressures and image quality (resolution of metal particles smaller than 1 nm in size) was achieved.

Heinemann, K.↗