Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microfluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Transport of colloidal particles in microscopic porous medium analogs with surface charge heterogeneity: experiments and fundamental role of single-bead deposition

Understanding colloid transport in subsurface environments is challenging due to complex interactions between colloids, ground water, and porous media over several length scales. Here, we study the transport of colloidal particles through bead-assembled microfluidic porous media analogs (PMAs) with surface charge heterogeneity. The pore-scale dynamics of colloidal particle deposition were measured, as well as the breakthrough curves (BTC) and retention profiles (RP) of deposited colloidal particles at the scale of the entire PMA. From pore-scale experiments, the maximum surface coverage (?max = 0.51) was measured directly, from which the surface blocking function and deposition coefficient (kpore = 3.56 s-1) were obtained. Using these pore-scale parameters, the transport of colloidal particles was modeled using a one-dimensional advection-dispersion equation under the assumption of irreversible adsorption between oppositely charged beads and colloids, showing good agreement with experimental data. This work presents a new approach to fabricate chemically heterogeneous porous media in a microfluidic device that enables direct measurements of pore-scale colloidal deposition. The approach allows a quantitative prediction of colloidal breakthrough and retention via coupling of direct measurements and an advection-dispersion-deposition model.

Guo, Yang↗

Coaxial Ceramic Direct Ink Writing on Heterogenous and Rough Surfaces: Investigation of Core–Shell Interactions

In this work, coaxial conductor–ceramic direct ink writing enables the printing of sensitive or encapsulated materials onto heterogeneous and rough substrates. While encasing the core fluid within a stiff ceramic shell, continuity may be maintained, even while printing onto conventionally challenging substrates. Here, we report the development of a coaxial ceramic direct ink writing suite and explore coflow interrelationships based on microfluidic principles. A coaxial nozzle is designed to facilitate the coextrusion of an alumina shell, whereas indium–tin-oxide inks constitute the core. In this manner, a core–shell ceramic element may be printed onto rough substrates for future high-temperature applications. Colloidal inks are engineered to provide the required rheological and sintering performance. Moreover, flow simulations in conjunction with microfluidic coflow principles are used to explore the coaxial printing processing space, thus controlling the core–shell architectures. Physical modeling is further used to analyze core deformations and eccentricity. As a result, simulations are validated experimentally, and the analyses are used to deposit coaxial ceramic features onto heterogeneous, high-temperature ceramic substrates.

20 FOSSIL-FUELED POWER PLANTS↗

Liquid-based gating mechanism with tunable multiphase selectivity and antifouling behaviour

Living organisms make extensive use of micro- and nanometre-sized pores as gatekeepers for controlling the movement of fluids, vapours and solids between complex environments. The ability of such pores to coordinate multiphase transport, in a highly selective and subtly triggered fashion and without clogging, has inspired interest in synthetic gated pores for applications ranging from fluid processing to 3D printing and lab-on-chip systems(1-10). But although specific gating and transport behaviours have been realized by precisely tailoring pore surface chemistries and pore geometries(6,11-17), a single system capable of controlling complex, selective multiphase transport has remained a distant prospect, and fouling is nearly inevitable(11,12). Here we introduce a gating mechanism that uses a capillary-stabilized liquid as a reversible, reconfigurable gate that fills and seals pores in the closed state, and creates a non-fouling, liquid-lined pore in the open state. Theoretical modelling and experiments demonstrate that for each transport substance, the gating threshold-the pressure needed to open the pores-can be rationally tuned over a wide pressure range. This enables us to realize in one system differential response profiles for a variety of liquids and gases, even letting liquids flow through the pore while preventing gas from escaping. These capabilities allow us to dynamically modulate gas-liquid sorting in a microfluidic flow and to separate a three-phase air-water-oil mixture, with the liquid lining ensuring sustained antifouling behaviour. Because the liquid gating strategy enables efficient long-term operation and can be applied to a variety of pore structures and membrane materials, and to micro- as well as macroscale fluid systems, we expect it to prove useful in a wide range of applications.

Hou, X↗

Metabolites from intact phage-infected Synechococcus chemotactically attract heterotrophic marine bacteria

Chemical cues mediate interactions between marine phytoplankton and bacteria, underpinning ecosystem-scale processes including nutrient cycling and carbon fixation. Phage infection alters host metabolism, stimulating the release of chemical cues from intact plankton, but how these dynamics impact ecology and biogeochemistry is poorly understood. Here we determine the impact of phage infection on dissolved metabolite pools from marine cyanobacteria and the subsequent chemotactic response of heterotrophic bacteria using time-resolved metabolomics and microfluidics. Metabolites released from intact, phage-infected Synechococcus elicited strong chemoattraction from Vibrio alginolyticus and Pseudoalteromonas haloplanktis, especially during early infection stages. Sustained bacterial chemotaxis occurred towards live-infected Synechococcus, contrasted by no discernible chemotaxis towards uninfected cyanobacteria. High-throughput microfluidics identified 5′-deoxyadenosine and 5′-methylthioadenosine as key attractants. Our findings establish that, before lysis, phage-infected picophytoplankton release compounds that attract motile heterotrophic bacteria, suggesting a mechanism for resource transfer that might impact carbon and nutrient fluxes across trophic levels.

Henshaw, Richard J↗

Label-free time- and space-resolved exometabolite sampling of growing plant roots through nanoporous interfaces

Abstract Spatial and temporal profiling of metabolites within and between living systems is vital to understanding how chemical signaling shapes the composition and function of these complex systems. Measurement of metabolites is challenging because they are often not amenable to extrinsic tags, are diverse in nature, and are present with a broad range of concentrations. Moreover, direct imaging by chemically informative tools can significantly compromise viability of the system of interest or lack adequate resolution. Here, we present a nano-enabled and label-free imaging technology using a microfluidic sampling network to track production and distribution of chemical information in the microenvironment of a living organism. We describe the integration of a polyester track-etched (PETE) nanofluidic interface to physically confine the biological sample within the model environment, while allowing fluidic access via an underlying microfluidic network. The nanoporous interface enables sampling of the microenvironment above in a time-dependent and spatially-resolved manner. For demonstration, the diffusional flux through the PETE membrane was characterized to understand membrane performance, and exometabolites from a growing plant root were successfully profiled in a space- and time-resolved manner. This method and device provide a frame-by-frame description of the chemical environment that maps to the physical and biological characteristics of the sample.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamic Morphologies of Microscale Droplet Interface Bilayers

Droplet interface bilayers (DIBs) are a powerful platform for studying the dynamics of synthetic cellular membranes; however, very little has been done to exploit the unique dynamical features of DIBs. Here, we generate microscale droplet interface bilayers ( DIBs) by bringing together femtoliter-volume water droplets in a microfluidic oil channel, and characterize morphological changes of the DIBs as the droplets shrink due to evaporation. By varying the initial conditions of the system, we identify three distinct classes of dynamic morphology. (1) Buckling and Fission: When forming DIBs using the lipid-out method (lipids in oil phase), lipids in the shrinking monolayers continually pair together and slide into the bilayer to conserve their mass. As the bilayer continues to grow, it becomes confined, buckles, and eventually fissions one or more vesicles. (2) Uniform Shrinking: When using the lipid-in method (lipids in water phase) to form DIBs, lipids uniformly transfer from the monolayers and bilayer into vesicles contained inside the water droplets. (3) Stretching and Unzipping: Finally, when the droplets are pinned to the wall(s) of the microfluidic channel, the droplets become stretched during evaporation, culminating in the unzipping of the bilayer and droplet separation. These findings offer a better understanding of the dynamics of coupled lipid interfaces.

Mruetusatorn, Prachya↗

Hydrodynamic trapping for rapid assembly and in situ electrical characterization of droplet interface bilayer arrays

The droplet interface bilayer (DIB) is a modular technique for assembling planar lipid membranes between water droplets in oil. The DIB method thus provides a unique capability for developing digital, droplet-based membrane platforms for rapid membrane characterization, drug screening and ion channel recordings. This paper demonstrates a new, low-volume microfluidic system that automates droplet generation, sorting, and sequential trapping in designated locations to enable the rapid assembly of arrays of DIBs. The channel layout of the device is guided by an equivalent circuit model, which predicts that a serial arrangement of hydrodynamic DIB traps enables sequential droplet placement and minimizes the hydrodynamic pressure developed across filled traps to prevent squeeze-through of trapped droplets. Furthermore, the incorporation of thin-film electrodes fabricated via evaporation metal deposition onto the glass substrate beneath the channels allows for the first time in situ, simultaneous electrical interrogation of multiple DIBs within a sealed device. Combining electrical measurements with imaging enables measurements of membrane capacitance and resistance and bilayer area, and our data show that DIBs formed in different trap locations within the device exhibit similar sizes and transport properties. Simultaneous, single channel recordings of ion channel gating in multiple membranes are obtained when alamethicin peptides are incorporated into the captured droplets, qualifying the thin-film electrodes as a means for measuring stimuli-responsive functions of membrane-bound biomolecules. Furthermore, this novel microfluidic-electrophysiology platform provides a reproducible, high throughput method for performing electrical measurements to study transmembrane proteins and biomembranes in low-volume, droplet-based membranes.

59 BASIC BIOLOGICAL SCIENCES↗

A multi-modal sweat sensing patch for cross-verification of sweat rate, total ionic charge, and Na + concentration

Sweat sensors introduced in recent years have targeted a variety of sweat features and biomarkers for non-invasive health monitoring. Amongst these targets, reliable monitoring of sweat rate is crucial due to its modulation of sweat analyte concentrations and its intrinsic significance to numerous medical and physiological health conditions. In this paper, we present a sweat rate sensor structure comprising of electrodes with interdigitated fingers in a microfluidic channel. Each time the accumulating sweat impinges on an electrode finger, the sensor reports a jump in admittance that can be simply and efficiently counted to estimate sweat rate, overcoming selectivity limitations of previously reported sweat rate sensors. We further integrate an impedimetric sensor for measuring total ionic charge concentration and an electrochemical Na + sensor, together creating a multi-modal system for analyzing fluid and electrolyte secretion. We demonstrate how low analyte diffusion rates through this microfluidic device allow for multi-purpose sensor function, including utilizing the sweat rate sensor signal to corroborate total ionic sensor measurements. This cross-verification capability ensures data integrity in real time, satisfying a vital consideration for personalized healthcare technologies. We use the presented patch for continuous analysis of sweat rate, total ionic charge concentration, and Na + concentration during exercise, while demonstrating how multi-modal cross-verification brings new trust to sensor readings.

47 OTHER INSTRUMENTATION↗

Modular droplet injector for sample conservation providing new structural insight for the conformational heterogeneity in the disease-associated NQO1 enzyme

Droplet injection strategies are a promising tool to reduce the large amount of sample consumed in serial femtosecond crystallography (SFX) measurements at X-ray free electron lasers (XFELs) with continuous injection approaches. Here, we demonstrate a new modular microfluidic droplet injector (MDI) design that was successfully applied to deliver microcrystals of the human NAD(P)H:quinone oxidoreductase 1 (NQO1) and phycocyanin. We investigated droplet generation conditions through electrical stimulation for both protein samples and implemented hardware and software components for optimized crystal injection at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Stanford Linac Coherent Light Source (LCLS). Under optimized droplet injection conditions, we demonstrate that up to 4-fold sample consumption savings can be achieved with the droplet injector. In addition, we collected a full data set with droplet injection for NQO1 protein crystals with a resolution up to 2.7 Å, leading to the first room-temperature structure of NQO1 at an XFEL. NQO1 is a flavoenzyme associated with cancer, Alzheimer's and Parkinson's disease, making it an attractive target for drug discovery. Further, our results reveal for the first time that residues Tyr128 and Phe232, which play key roles in the function of the protein, show an unexpected conformational heterogeneity at room temperature within the crystals. These results suggest that different substates exist in the conformational ensemble of NQO1 with functional and mechanistic implications for the enzyme's negative cooperativity through a conformational selection mechanism. Our study thus demonstrates that microfluidic droplet injection constitutes a robust sample-conserving injection method for SFX studies on protein crystals that are difficult to obtain in amounts necessary for continuous injection, including the large sample quantities required for time-resolved mix-and-inject studies.

59 BASIC BIOLOGICAL SCIENCES↗

Vortex fluidic regulated phospholipid equilibria involving liposomes down to sub-micelle size assemblies

Conventional channel-based microfluidic platforms have gained prominence in controlling the bottom-up formation of phospholipid based nanostructures including liposomes. However, there are challenges in the production of liposomes from rapidly scalable processes. These have been overcome using a vortex fluidic device (VFD), which is a thin film microfluidic platform rather than channel-based, affording ~110 nm diameter liposomes. The high yielding and high throughput continuous flow process has a 45° tilted rapidly rotating glass tube with an inner hydrophobic surface. Processing is also possible in the confined mode of operation which is effective for labelling pre-VFD-prepared liposomes with fluorophore tags for subsequent mechanistic studies on the fate of liposomes under shear stress in the VFD. In situ small-angle neutron scattering (SANS) established the co-existence of liposomes ~110 nm with small rafts, micelles, distorted micelles, or sub-micelle size assemblies of phospholipid, for increasing rotation speeds. The equilibria between these smaller entities and ~110 nm liposomes for a specific rotational speed of the tube is consistent with the spatial arrangement and dimensionality of topological fluid flow regimes in the VFD. The prevalence for the formation of ~110 nm diameter liposomes establishes that this is typically the most stable structure from the bottom-up self-assembly of the phospholipid and is in accord with dimensions of exosomes.

60 APPLIED LIFE SCIENCES↗

Random lasing action in a polydimethylsiloxane wrinkle induced disordered structure

This paper presents a chip-scale random lasing action utilizing polydimethylsiloxane (PDMS) wrinkles with random periods as disordered medium. Nanoscale wrinkles with long range disorder structures are formed on the oxidized surface of a PDMS slab and confirmed by atomic force microscopy. Light multiply scattered at each PDMS wrinkle-dye interfaces is optically amplified in the presence of pump gain. The shift of laser emission wavelength when pumping at different regions indicates the randomness of the winkle period. In addition, a relatively low threshold of about 27 μJ/mm{sup 2} is realized, which is comparable with traditional optofluidic dye laser. This is due to the unique sinusoidal Bragg-grating-like random structure. Contrast to conventional microfluidic dye laser that inevitably requires the accurate design and implementation of microcavity to provide optical feedback, the convenience in both fabrication and operation makes PDMS wrinkle based random laser a promising underlying element in lab-on-a-chip systems and integrated microfluidic networks.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A widefield fluorescence microscope with a linear image sensor for image cytometry of biospecimens: Considerations for image quality optimization

Linear image sensors have been widely used in numerous research and industry applications to provide continuous imaging of moving objects. Here, we present a widefield fluorescence microscope with a linear image sensor used to image translating objects for image cytometry. First, a calibration curve was characterized for a custom microfluidic chamber over a span of volumetric pump rates. Image data were also acquired using 15 μm fluorescent polystyrene spheres on a slide with a motorized translation stage in order to match linear translation speed with line exposure periods to preserve the image aspect ratio. Aspect ratios were then calculated after imaging to ensure quality control of image data. Fluorescent beads were imaged in suspension flowing through the microfluidics chamber being pumped by a mechanical syringe pump at 16 μl min{sup −1} with a line exposure period of 150 μs. The line period was selected to acquire images of fluorescent beads with a 40 dB signal-to-background ratio. A motorized translation stage was then used to transport conventional glass slides of stained cellular biospecimens. Whole blood collected from healthy volunteers was stained with 0.02% (w/v) proflavine hemisulfate was imaged to highlight leukocyte morphology with a 1.56 mm × 1.28 mm field of view (1540 ms total acquisition time). Oral squamous cells were also collected from healthy volunteers and stained with 0.01% (w/v) proflavine hemisulfate to demonstrate quantifiable subcellular features and an average nuclear to cytoplasmic ratio of 0.03 (n = 75), with a resolution of 0.31 μm pixels{sup −1}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Centrifugal sedimentation immunoassays for multiplexed detection of enteric bacteria in ground water

Water-born pathogens pose significant threat to the global population and early detection plays an important role both in making drinking water safe, as well as in diagnostics and treatment of water-borne diseases. We present an innovative centrifugal microfluidic platform (SpinDx) for detection of bacterial pathogens using bead-based immunoassays. Our approach is based on binding of pathogens to antibody-functionalized capture particles followed by sedimentation of the particles through a density-media in a microfluidic disk and quantification by fluorescence microscopy. Our platform is fast (20 min), sensitive (10 3 CFU/mL), requires minimal sample preparation, and can detect multiple pathogens simultaneously with sensitivity similar to that required by the EPA. We demonstrate detection of a panel of enteric bacteria (Escherichia coli, Salmonella typhimurium, Shigella, Listeria, and Campylobacter) at concentrations as low as 10 3 CFU/mL or 30 bacteria per reaction.

59 BASIC BIOLOGICAL SCIENCES↗

Inertio-elastic mixing in a straight microchannel with side wells

Mixing remains a challenging task in microfluidic channels because of their inherently small length scale. In this work, we propose an efficient microfluidic mixer based on the chaotic vortex dynamics of a viscoelastic flow in a straight channel with side wells. When the inertia and elasticity of a dilute polymer solution are balanced (i.e., the Reynolds number Re and Weissenberg number Wi are both on the order of 10{sup 1}), chaotic vortices appear in the side wells (inertio-elastic flow instability), enhancing the mixing of adjacent fluid streams. However, there is no chaotic vortex motion in Newtonian flows for any flow rate. Efficient mixing by such an inertio-elastic instability is found to be relevant for a wide range of Re values.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hydrodynamic dispersion in thin channels with micro-structured porous walls

Flowand transport within porous- and microtextured-walled channels is relevant to a number of natural and industrial processes. Designing and optimizing the topology of the pores and/or microstructure to achieve target performance at the system scale (or macroscale) is still an open question. In this work, we study whether hydrodynamic dispersion in microfluidic channels with walls structured by obstacles can be modeled by dispersion in channels with porous walls described as continuous porous media of zero or finite permeability. We perform single phase microfluidic non-reactive flow experiments in channels embedded in micropatterns with different topologies. Specifically, we focus on transverse riblets and arrays of pillars as examples of impermeable and permeable obstructions, respectively. We compare the experimental results with three models: 3D pore-scale simulations which resolve the micropattern geometry explicitly and two upscaled models which treat the micropattern as a continuum of zero or finite permeability. This study demonstrates that polydimethylsiloxane micromodels with appropriately patterned surfaces can be successfully employed to validate various continuum-scale modeling approximations in different physical regimes, identified by the order of magnitude of the Peclet number and the obstruction permeability.

Ling, Bowen↗

Viscous flow properties and hydrodynamic diameter of phenothiazine-based redox-active molecules in different supporting salt environments

We report viscous flow properties of a redox-active organic molecule, N-(2-(2-methoxyethoxy)ethyl)phenothiazine (MEEPT), a candidate for non-aqueous redox flow batteries, and two of its radical cation salts. A microfluidic viscometer enabled the use of small sample volumes in determining viscosity as a function of shear rate and concentration in the non-aqueous solvent, acetonitrile, both with and without supporting salts. All solutions tested show Newtonian behavior over shear rates of up to 30 000 s−1, which was rationalized by scaling arguments for the diffusion-based relaxation time of a single MEEPT molecule without aggregation. Neat MEEPT is flowable but with a large viscosity (412 mPa⋅s at room temperature), which is ∼1000 times larger than that of acetonitrile. MEEPT solutions in acetonitrile have low viscosities; at concentrations up to 0.5 M, the viscosity increases by less than a factor of two. From concentration-dependent viscosity measurements, molecular information was inferred from intrinsic viscosity (hydrodynamic diameter) and the Huggins coefficient (interactions). Model fit credibility was assessed using the Bayesian Information Criterion. It is found that the MEEPT and its charged cations are “flowable” and do not flocculate at concentrations up to 0.5 M. MEEPT has a hydrodynamic diameter of around 8.5 Å, which is almost insensitive to supporting salt and state of charge. This size is comparable to molecular dimensions of single molecules obtained from optimized structures using density functional theory calculations. The results suggest that MEEPT is a promising candidate for redox flow batteries in terms of its viscous flow properties.

Wang, Yilin (ORCID:0000000316102995)↗

Infrared compatible rapid mixer to probe millisecond chemical kinetics

Fast microfluidic mixers are a valuable tool for studying solution-phase chemical reaction kinetics and molecular processes with spectroscopy. However, microfluidic mixers that are compatible with infrared vibrational spectroscopy have seen only limited development due to the poor infrared transparency of the current microfabrication material. We describe the design, fabrication, and characterization of CaF2-based continuous flow turbulent mixers, which are capable of measuring kinetics in the millisecond time window with infrared spectroscopy, when integrated into an infrared microscope. Kinetics measurements demonstrate the ability to resolve relaxation processes with 1 millisecond time resolution, and straightforward improvements are described that should result in sub-100 µs time-resolution.

Instruments & Instrumentation↗

Fluid inertia controls mineral precipitation and clogging in pore to network-scale flows

Mineral precipitation caused by fluid mixing presents complex control and predictability challenges in a variety of natural and engineering processes, including carbon mineralization, geothermal energy, and microfluidics. Precipitation dynamics, particularly under the influence of fluid flow, remain poorly understood. Combining microfluidic experiments and three-dimensional reactive transport simulations, we demonstrate that fluid inertia controls mineral precipitation and clogging at flow intersections, even in laminar flows. We observe distinct precipitation regimes as a function of Reynolds number (Re). At low Reynolds numbers (Re < 10), precipitates form a thin, dense layer along the mixing interface, which shuts precipitation off, while at high Reynolds numbers (Re > 50), strong three-dimensional flows significantly enhance precipitation over the entire intersection, resulting in rapid clogging. When injection rates from two inlets are uneven, flow symmetry-breaking leads to unexpected flow bifurcation phenomena, which result in enhanced concurrent precipitation in both downstream channels. Finally, we extend our findings to rough channel networks and demonstrate that the identified inertial effects on precipitation at the intersection scale are also present and even more dramatic at the network scale. This study sheds light on the fundamental mechanisms underlying mixing-induced mineral precipitation and provides a framework for designing and optimizing processes involving mineral precipitation.

Science & Technology - Other Topics↗