Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “meter, test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Development of a Test Protocol for Spacecraft Post-Fire Atmospheric Cleanup and Monitoring

Detecting and extinguishing fires, along with post-fire atmospheric cleaning and monitoring, are vital components of a spacecraft fire response system. Preliminary efforts focused on the technology evaluation of these systems under realistic conditions are described in this paper. While the primary objective of testing is to determine a smoke mitigation filter s performance, supplemental evaluations measuring the smoke-filled chamber handheld commercial off-the-shelf (COTS) atmospheric monitoring devices (combustion product monitors) are also conducted. The test chamber consists of a 1.4 cubic meter (50 cu. ft.) volume containing a smoke generator. The fuel used to generate the smoke is a mixture of polymers in quantities representative of materials involved in a circuit board fire as a typical spacecraft fire. Two fire conditions were examined: no flame and flame. No flame events are produced by pyrolyzing the fuel mixture in a quartz tube furnace with forced ventilation to produce a white, lingering-type smoke. Flame events ignite the smoke at the outlet of the tube furnace producing combustion characterized by a less opaque smoke with black soot. Electrochemical sensor measurements showed carbon monoxide is a major indicator of each fire. Acid gas measurements were recorded, but cross interferents are currently uncharacterized. Electrochemical sensor measurements and sample acquisition techniques from photoacoustic sensors are being improved. Overall, this research shows fire characterization using traditional analytical chemistry techniques is required to verify measurements recorded using COTS atmospheric monitoring devices.

Zuniga, David↗

Lightning Strike Distance Distribution Beyond a Preexisting Lightning Area

The 45th Weather Squadron (45 WS) asked the Applied Meteorology Unit (AMU) to review the 30-year-old, lightning stand-off distances of 5 nautical miles (nmi) for applicability to today's operations. This was based on the realization that previous lightning strike distance studies did not match how 45 WS issues lightning warnings (Roeder, 2008). The previous lightning distance studies were from the point of origin of the lightning or the average starting location that would tend to be in the core of the thunderstorm. However, the 45 WS issues lightning warnings based on the edge of a preexisting lightning area. Before beginning the AMU project, it took several years to develop a method to calculate a distance distribution beyond a preexisting area (Roeder, 2015). The AMU pulled Lightning Detection and Ranging (LDAR) sensor data from 1/1/2013 to 12/31/2013. This dataset consisted of 37 million individual source data points from the LDAR sensors. Only sources within 50 km north, south, east or west of the LDAR grid center were included in the dataset. This limited the use of LDAR data to that with the greatest accuracy of source detection and increased data processing. Points were grouped into flashes based on spatial and temporal criteria. Based on the sensitivity analysis the AMU performed on the flash clustering algorithm, a time value of 0.3 seconds was found to model flashes adequately. Distance parameters were tested from 1,500 to 7,500 meters (m) in 500 m increments. Distance parameters of both 3,000 m and 4,000 m produced results in the plotting tool that were most representative of the physical behavior of lightning. Thus statistics were gathered for the most representative of these spatial and temporal criteria on the flash size and the polygon expansion distance in order to find the correct data distributions. The best fit curves for the LDAR polygon expansion frequency vs. distances for both the 3 kilometer (km) and 4 km distance threshold values were exponential decay functions and had R2 values of > 0.998, indicating good model fits. The equations of the best fit curves were then used to calculate a desired safety radius of 4 nmi for either 3 km or 4 km distance threshold criteria. The AMU analysis concludes the safe reduction of the 5 nmi lightning warning circles to 4 nmi should improve the operational impact by 36% if based on distance from the center of the property area being protected. If based on the edge of the property being protected, then the reduction is 4.5 nmi to 4 nmi and the operational impact is decreased by 21%. For the 6 nmi lightning warning circles, the recommended 4 nmi stand-off distance will result in a safe reduction of operational impact of 31% if based on the center of the area being protected, or 16% if based on the edge of the property.

Flash clustering algorithm↗

Application of STARFLEET Velocimetry in the NASA Langley 0.3-Meter Transonic Cryogenic Tunnel

Selective two-photon absorptive resonance femtosecond laser electronic excitation tagging (STARFLEET) velocimetry is demonstrated for the first time in a NASA Langley wind tunnel with high repetition-rate and single-shot imaging. Experiments performed in the 0.3-meter Transonic Cryogenic Tunnel (TCT) allowed for testing at 300 K over a range of pressures (124 to 517 kPa) and Mach numbers (0.2-0.8) for freestream conditions and flow behind a cylindrical model. Measurement precision and accuracy are determined for the current set of experiments, as are signal intensity and lifetime. Precisions of 3-5 m/s (based on one standard deviation) were typical in the experiment; precisions better than 2% of the mean velocity were obtained for some of the highest velocity conditions. Agreement within a mean error of 3 m/s between STARFLEET freestream velocity measurements and facility DAS readings is demonstrated. STARFLEET is also shown to return spatially-resolved velocity profiles, though some binning of the signal is required.

STARFLEET↗

Development and application of a standardized flow measurement uncertainty analysis framework to various low-head short-converging intake types across the United States federal hydropower fleet

Turbine discharges at low-head short converging intakes are difficult to measure accurately. The proximity of the measurement section to the intake entrance admits large uncertainties related to asymmetry of the velocity profile, swirl, and turbulence. Existing turbine performance codes [10, 24] do not address this special case and published literature is largely silent on rigorous evaluation of uncertainties associated with this measurement context. The American Society of Mechanical Engineers (ASME) Committee investigated the use of Acoustic transit time (ATT), Acoustic scintillation (AS), and Current meter (CM) in a short converging intake at the Kootenay Canal Generating Station in 2009. Based on their findings, a standardized uncertainty analysis (UA) framework for velocity-area method (specifically for CM measurements) is presented in this paper given the fact that CM is still the most fundamental and common type of measurement system. Typical sources of systematic and random errors associated with CM measurements are investigated, and the major sources of uncertainties associated with turbulence and velocity fluctuations, numerical velocity integration technique (bi-cubic spline), and the number and placement of current meters are being considered for an evaluation. Since the velocity measurements in a short converging intake are associated with complex nonlinear and time varying uncertainties (e.g., Reynolds stress in fluid dynamics), simply applying the law of propagation of uncertainty is known to overestimate the measurement variance while the Monte Carlo method does not. Therefore, a pseudo-Monte Carlo simulation method (random flow generation technique [8]) which was initially developed for the purpose of establishing upstream or initial conditions in the Large-Eddy Simulation (LES) and the Direct Numerical Simulation (DNS) is used to statistically determine uncertainties associated with turbulence and velocity fluctuations. This technique is then combined with a bi-cubic spline interpolation method which converts point velocities into a continuous velocity distribution over the measurement domain. Subsequently the number and placement of current meters are simulated to investigate the accuracy of the estimated flow rates using the numerical velocity-area integration method outlined in ISO 3354 [12]. The authors herein consider that statistics on generated flow rates processed with bi-cubic interpolation and sensor simulations are the combined uncertainties which already accounted for the effects of all those three uncertainty sources. A preliminary analysis based on the current meter data obtained through an upgrade acceptance test of a single unit located in a mainstem plant has been presented.

Smith, Brennan T↗

Quench protection of the first 4 m long prototype of the HL-LHC Nb3Sn quadrupole magnet

The quadrupole magnets for the LHC upgrade to higher luminosity are jointly developed by CERN and US-LARP (LHC Accelerator Research Program). These Nb3Sn magnets will be protected against overheating after a quench by a combination of heaters bonded to the coil outer surface and CLIQ (Coupling-Loss Induced Quench) units. The first 4 meter long prototype magnet, called MQXFAP1, was tested at the Brookhaven National Laboratory in stand-alone configuration. The magnet training campaign, consisting of 18 quenches, was interrupted due to the development of a short circuit between one heater strip and the coil. During the campaign, different quench protection schemes were implemented, including heaters attached to outer and inner layers, one CLIQ unit, and the energy-extraction system. The configuration including outer-layer heaters and CLIQ achieved the fastest current discharge, hence the lowest hot-spot temperature. The electro-magnetic and thermal transients after a quench were simulated with the program STEAM-LEDET and found in good agreement.

43 PARTICLE ACCELERATORS↗

Evaluation of a Turbidity Meter for Use at the Defense Waste Processing Facility

Savannah River Remediation’s (SRR’s) Defense Waste Processing Facility (DWPF) Laboratory currently tests for sludge carry-over into the Recycle Collection Tank (RCT) by evaluating the iron concentration in the Slurry Mix Evaporator Condensate Tank (SMECT) and relating this iron concentration to the amount of sludge solids present. A new method was proposed for detecting the amount of sludge in the SMECT that involves the use of an Optek turbidity sensor. Waste Services Laboratory (WSL) personnel conducted testing on two of these units following a test plan developed by Waste Solidification Engineering (WSE). Both Optek units (SN64217 and SN65164) use sensor model AF16-N and signal converter model series C4000. The sensor body of each unit was modified to hold a standard DWPF 12 cc sample vial, also known as a “peanut” vial. The purpose of this testing was to evaluate the use of this model of turbidity sensor, or meter, to provide a measurement of the sludge solids present in the SMECT based upon samples from that tank. During discussions of the results from this study by WSE, WSL, and Savannah River National Laboratory (SRNL) personnel, an upper limit on the acceptable level of solids in SMECT samples was set at 0.14 weight percent (wt%). A “go/no-go” decision criterion was to be developed for the critical turbidity response, which is expressed in concentration units (CUs), for each Optek unit based upon the 0.14 wt% solids value. An acceptable or a “go” decision for the SMECT should reflect the situation that there is an identified risk (e.g. 5%) for a CU response from the Optek unit to be less than the critical CU value when the solids content of the SMECT is actually 0.14 wt% or greater, while a “no-go” determination (i.e., an Optek CU response above the critical CU value, a conservative decision relative to risk) would lead to additional evaluations of the SMECT to better quantify the possible solids content of the tank. Subsequent to the issuance of the initial version of this report but under the scope of the original request for technical assistance, WSE asked for this report to be revised to include the “go/no-go” CU value corresponding to 0.28 wt% solids. It was this request that led to the preparation of Revision 1 of the report. The results for the 0.28 wt% solids value were developed following the same approach as that utilized for the 0.14 wt% solids value. A sludge simulant was used to develop standards for testing both Optek units and to determine the viability of a “go/no-go” CU response for each of the units. Statistical methods were used by SRNL to develop the critical CU value for the “go/no-go” decision for these standards for each Optek unit. Since only one sludge simulant was available for this testing, the sensitivity of these results to other simulants and to actual sludge material is not known. However, limited testing with samples from the actual DWPF process (both SRAT product samples and SMECT samples) demonstrated that the use of the “go/no-go” criteria developed from the sludge simulant testing was conservative for these samples taken from the sludge batch, Sludge Batch 7b, being processed at the time of this testing. While both of the Optek units performed very reliably during this testing, there were statistically significant differences (although small on a practical scale) between the two units. Thus, testing should be conducted on any new unit of this Optek model to qualify it before it is used to support the DWPF operation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energy System Modeling with REopt

This poster details how REopt - NREL's software modeling platform for energy systems integration and optimization - can help to model energy systems. Some benefits of modeling with REopt include optimizing behind the meter storage for cost and resiliency, optimizing lab testing, optimizing dispatch of utility scale storage, and quantifying renewable energy impact on outage survivability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Implementing the Mars Science Laboratory Terminal Descent Sensor Field Test Campaign

The Mars Science Laboratory (MSL) will deliver a 900 kg rover to the surface of Mars in August 2012. MSL will utilize a new pulse-Doppler landing radar, the Terminal Descent Sensor (TDS). The TDS employs six narrow-beam antennas to provide unprecedented slant range and velocity performance at Mars to enable soft touchdown of the MSL rover using a unique sky crane Entry, De-scent, and Landing (EDL) technique. Prior to use on MSL, the TDS was put through a rigorous verification and validation (V&V) process. A key element of this V&V was operating the TDS over a series of field tests, using flight-like profiles expected during the descent and landing of MSL over Mars-like terrain on Earth. Limits of TDS performance were characterized with additional testing meant to stress operational modes outside of the expected EDL flight profiles. The flight envelope over which the TDS must operate on Mars encompasses such a large range of altitudes and velocities that a variety of venues were neces-sary to cover the test space. These venues included an F/A-18 high performance aircraft, a Eurocopter AS350 AStar helicopter and 100-meter tall Echo Towers at the China Lake Naval Air Warfare Center. Testing was carried out over a five year period from July 2006 to June 2011. TDS performance was shown, in gen-eral, to be excellent over all venues. This paper describes the planning, design, and implementation of the field test campaign plus results and lessons learned.

Mars Science Laboratory (MSL)↗

Development of a pepper-pot emittance meter for diagnostics of low-energy multiply charged heavy ion beams extracted from an ECR ion source

Several fluorescent materials were tested for use in the imaging screen of a pepper-pot emittance meter that is suitable for investigating the beam dynamics of multiply charged heavy ions extracted from an ECR ion source. SiO{sub 2} (quartz), KBr, Eu-doped CaF{sub 2}, and Tl-doped CsI crystals were first irradiated with 6.52-keV protons to determine the effects of radiation damage on their fluorescence emission properties. For such a low-energy proton beam, only the quartz was found to be a suitable fluorescent material, since the other materials suffered a decay in fluorescence intensity with irradiation time. Subsequently, quartz was irradiated with heavy {sup 12}C{sup 4+}, {sup 16}O{sup 4+}, and {sup 40}Ar{sup 11+} ions, but it was found that the fluorescence intensity decreased too rapidly to measure the emittance of these heavy-ion beams. These results suggest that a different energy loss mechanism occurs for heavier ions and for protons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation Of A Turbidity Meter For Use At The Defense Waste Processing Facility

Savannah River Remediation’s (SRR’s) Defense Waste Processing Facility (DWPF) Laboratory currently tests for sludge carry-over into the Recycle Collection Tank (RCT) by evaluating the iron concentration in the Slurry Mix Evaporator Condensate Tank (SMECT) and relating this iron concentration to the amount of sludge solids present. A new method was proposed for detecting the amount of sludge in the SMECT that involves the use of an Optek turbidity sensor. Waste Services Laboratory (WSL) personnel conducted testing on two of these units following a test plan developed by Waste Solidification Engineering (WSE). Both Optek units (SN64217 and SN65164) use sensor model AF16-N and signal converter model series C4000. The sensor body of each unit was modified to hold a standard DWPF 12 cc sample vial, also known as a “peanut” vial. The purpose of this testing was to evaluate the use of this model of turbidity sensor, or meter, to provide a measurement of the sludge solids present in the SMECT based upon samples from that tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Metering Characteristics of Carburetors

Report presents the results of an extensive experimental investigation of the performance of different types of carburetors as effecting the maintenance under all conditions of correct ratio between the weights of fuel and air. It also gives a description of the Bureau of Standards carburetor test plant, test equipment and measuring instruments used to determine the metering characteristics of carburetors.

Tice, Percival S↗

Radio frequency performance predictions for the hoop/column point design

Preliminary antenna pattern tests were conducted to determine if catastrophic effects were produced by cables (conducting) in the aperture. This test consisted of an apex feed illuminating a 3 meter solid reflector. A hoop/column configuration was used in positioning the various wires and cables. Radiation patterns were measured at 7 GHz and 10 GHz. No catastrophic effects were observed for this configuration, but additional tests are required to determine the effects for more precision multiple beam applications. In order to better understand the scattering and blockage effects on multiple beam performance, a 35 GHz model was used to model somewhat a single quad aperture configuration. Experimental results using this models are presented in graphs.

Campbell, T. G.↗

Aerodynamic characteristics at Mach numbers from 0.33 to 1.20 of a wing-body design concept for a hypersonic research airplane

An experimental investigation of the static aerodynamic characteristics of a model of one design concept for the proposed National Hypersonic Flight Research Facility was conducted in the Langley 8 foot transonic pressure tunnel. The experiment consisted of configuration buildup from the basic body by adding a wing, center vertical tail, and a three module or six module scramjet engine. The freestream test Mach numbers were 0.33, 0.80, 0.90, 0.95, 0.98, 1.10, and 1.20 at Reynolds numbers per meter ranging from 4.8 x 1 million to 10.4 x 1 million. The test angle of attack range was approximately -4 deg to 22 deg at constant angles of sideslip of 0 deg and 4 deg; the angle of sideslip ranged from about -6 deg to 6 deg at constant angles of attack of 0 deg and 17 deg. The elevons were deflected 0 deg, -10 deg, and -20 deg with rudder deflections of 0 deg and 15.6 deg.

Dillon, J. L.↗

EGS Collab - Hydraulic Fracturing Test Measurements on the 4100L of SURF

This package includes data from two days of testing at the Sanford Underground Research Facility (SURF) on the 4100 level. The tests were performed in borehole TV4100 in the battery charging alcove south of the Yates shaft. TV4100 is a vertical borehole ~50 meters deep. A series of hydraulic fracture (mini-frac) and reopening tests were conducted at various depths to investigate the magnitude and direction of the minimum principal stress in that area of the mine. Apparent features of the pressure time/pressure injected volume curves are the onset of fracture, peak pressure, and the initial shut in pressure (ISIP). The raw data files include a Readme with the day, time, and location of each file. The files are organized into 9 columns: time (sec), flow meter (V), Pressure of Return (V), Pressure of Packer (V), Pressure of Injection (V), flow (gpm), Pressure of Return (psi), Pressure of Packer (psi), Pressure of Injection (psi). The shift reports are a short log of how the tests were run in the two-day period. An American Geophysical Union (AGU) 2019 presentation by Ingraham et al. is shown to provide visualization/interpretation of the data. The columns which report voltage (V) show the unscaled voltage value from the transducer, which was recorded in case pressure values needed to be rescaled due to incorrect calibration factors. This was not necessary. Results reported in the AGU poster were filtered with a moving average to remove pump noise before presentation. Note that the logging and impression packer results are included in separate datasets managed by Lawrence Berkeley Laboratory.

15 GEOTHERMAL ENERGY↗

Evaluation of the ride quality of a light twin engine airplane using a ride quality meter

A ride quality meter was used to establish the baseline ride quality of a light twin-engine airplane planned for use as a test bed for an experimental gust alleviation system. The ride quality meter provides estimates of passenger ride discomfort as a function of cabin noise and vibration (acceleration) in five axes (yaw axis omitted). According to the ride quality meter, in smooth air the cabin noise was the dominant source of passenger discomfort, but the total discomfort was approximately the same as that for the smooth-air condition. The researcher's subjective opinion, however, is that the total ride discomfort was much worse in the moderate turbulence than it was in the smooth air. The discrepancy is explained by the lack of measurement of the low-frequency accelerations by the ride quality meter.

Stewart, Eric C.↗

Fabrication and test of 4m long Nb3Sn quadrupole coil made of RRP-114-127 strand

Fermilab is collaborating with LBNL and BNL (US-LARP collaboration) to develop a large-aperture Nb{sub 3}Sn superconducting quadrupole for the Large Hadron Collider (LHC) luminosity upgrade. Several two-layer quadrupole models of the 1-meter and 3.4-meter length with 90mm apertures have been fabricated and tested by the US-LARP collaboration. High-Jc RRP-54/61 strand was used for nearly all models. Large flux jumps typical for this strand due to the large sub-element diameter limited magnet quench performance at temperatures below 2.5-3K. This paper summarizes the fabrication and test by Fermilab of LQM01, a long quadrupole coil test structure (quadrupole mirror) with the first 3.4m quadrupole coil made of more stable RRP-114/127 strand. The coil and structure are fully instrumented with voltage taps, full bridge strain gauges and strip heaters to monitor preload, thermal properties and quench behavior. Measurements during fabrication are reported, including preload during the yoke welding process. Testing is done at 4.5K, 1.9K and a range of intermediate temperatures. The test results include magnet strain and quench performance during training, as well as quench studies of current ramp rate and temperature dependence from 1.9K to 4.5K.

43 PARTICLE ACCELERATORS↗

Pressurant requirements for discharge of liquid methane from a 1.52-meter-(5-ft-) diameter spherical tank under both static and slosh conditions

Pressurized expulsion tests were conducted to determine the effect of various physical parameters on the pressurant gas (methane, helium, hydrogen, and nitrogen) requirements during the expulsion of liquid methane from a 1.52-meter-(5-ft-) diameter spherical tank and to compare results with those predicted by an analytical program. Also studied were the effects on methane, helium, and hydrogen pressurant requirements of various slosh excitation frequencies and amplitudes, both with and without slosh suppressing baffles in the tank. The experimental results when using gaseous methane, helium, and hydrogen show that the predictions of the analytical program agreed well with the actual pressurant requirements for static tank expulsions. The analytical program could not be used for gaseous nitrogen expulsions because of the large quantities of nitrogen which can dissolve in liquid methane. Under slosh conditions, a pronounced increase in gaseous methane requirements was observed relative to results obtained for the static tank expulsions. Slight decreases in the helium and hydrogen requirements were noted under similar test conditions.

Dewitt, R. L.↗