Salt mass determination by 22 Na-based radioactive tracer dilution of a highly radioactive molten salt system for pyroprocessing spent oxide nuclear fuels

To demonstrate the feasibility of the 22 Na-based radioactive tracer dilution (RTD) for determining the total salt mass in a 60-kg oxide reduction (OR) system at Idaho National Laboratory (INL) for pyroprocessing spent oxide nuclear fuels, a LiCl- 22 NaCl tracer salt was prepared and spiked to the OR vessel, and salt samples were analyzed by gamma spectroscopy. Due to the high radioactivity (around 10 mCi/g) of the OR salt, mainly from 137 Cs, traditional gamma spectroscopy methods, which typically involve diluted salt samples, was not effective for analyzing the RTD samples. Since the 22 Na tracer radioactivity was very low, undiluted samples were necessary to detect the small amount of 22 Na tracer. Here, despite the high gamma radioactivity of the OR salt, increasing the detector-sample distance from 20 cm to 40 cm during gamma spectroscopy allowed the detection of radioactivity as low as 0.12 µCi/g 22 Na. The preparation of the 22 NaCl-LiCl tracer salt suitable for spiking into the OR salt was successful, and the mass determined by RTD was consistent with that estimated by salt level measurement. Therefore, the 22 Na-based RTD technique for total mass determination of the 60-kg molten salt system for OR is feasible, though more development work, particularly in the improving the uncertainty, is needed .

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Intact mass spectrometry screening to optimize hydroxyl radical dose for protein footprinting

Hydroxyl radical protein footprinting (HRPF) using synchrotron radiation is a well-validated method to assess protein structure in the native solution state. In this method, X-ray radiolysis of water generates hydroxyl radicals that can react with solvent accessible side chains of proteins, with mass spectrometry used to detect the resulting labeled products. An ideal footprinting dose provides sufficient labeling to measure the structure but not so much as to influence the results. The optimization of hydroxyl radical dose is typically performed using an indirect Alexa488 fluorescence assay sensitive to hydroxyl radical concentration, but full evaluation of the experiment's outcome relies upon bottom-up liquid chromatography mass spectrometry (LC-MS) measurements to directly determine sites and extent of oxidative labeling at the peptide and protein level. A direct evaluation of the extent of labeling to provide direct and absolute measurements of dose and “safe” dose ranges in terms of, for example, average numbers of labels per protein, would provide immediate feedback on experimental outcomes prior to embarking on detailed LC-MS analyses. To this end, we describe an approach to integrate intact MS screening of labeled samples immediately following exposure, along with metrics to quantify the extent of observed labeling from the intact mass spectra. Intact MS results on the model protein lysozyme were evaluated in the context of Alexa488 assay results and a bottom-up LC-MS analysis of the same samples. In conclusion, this approach provides a basis for placing delivered hydroxyl radical dose metrics on firmer technical grounds for synchrotron X-ray footprinting of proteins, with explicit parameters to increase the likelihood of a productive experimental outcome. Further, the method directs approaches to provide absolute and direct dosimetry for all types of labeling for protein footprinting.

59 BASIC BIOLOGICAL SCIENCES↗

Strategies to overcome mass transfer limitations of hydrogen during anaerobic gaseous fermentations: A comprehensive review

Fermentation of gaseous substrates such as carbon dioxide (CO 2 ) has emerged as a sustainable approach for transforming greenhouse gas emissions into renewable fuels and biochemicals. CO 2 fermentations are catalyzed by hydrogenotrophic methanogens and homoacetogens, these anaerobic microorganisms selectively reduce CO 2 using hydrogen (H 2 ) as electron donor. However, H 2 possesses low solubility in liquid media leading to slow mass transport, limiting the reaction rates of CO 2 reduction. Solving the problems of mass transport of H 2 could boost the advance of technologies for valorizing industrial CO 2 -rich streams, like biogas or syngas. The application could further be extended to combustion flue gases or even atmospheric CO 2 . In this work, an overview of strategies for overcoming H 2 mass transport limitations during methanogenic and acetogenic fermentation of H 2 and CO 2 is presented. Here, the potential for using these strategies in future full-scale facilities and the knowledge gaps for these applications are discussed in detail.

09 BIOMASS FUELS↗

Carbon aerogels with integrated engineered macroporous architectures for improved mass transport

Carbon aerogels (CAs) combine unique properties including ultra-high surface area, high electrical conductivity, corrosion resistance, and robust mechanical properties making them ideal materials for electrochemical applications. Traditional CA synthesis results in isotropic, random nanoporous networks that work well for applications relying on diffusional mass transport. However, many applications would benefit from integration of engineered macroporous network structures that enable directed pressure-gradient-driven mass transport. In this study, we report on using 3D-printed sacrificial polymeric templates to generate templated CAs (t-CAs) with integrated engineered nonrandom macroporous network structures. Specifically, we used projection micro-stereo-lithography (PμSL) and two-photon polymerization direct laser writing (2PP-DLW) to fabricate millimeter-to-centimeter-sized 3D sacrificial polymeric templates with features ranging from tens of microns (PμSL) to 100s of nanometers (2PP-DLW). T-CAs were fabricated by infiltrating the templates with resorcinol-formaldehyde (RF) precursor solution, followed by carbonization at 1050 °C to simultaneously convert the RF gel to a CA and decompose the 3D-printed template, leaving an embedded templated macroporous network structure behind. X-ray computer tomography confirms integration of the macroporous architecture defined by the template. The templated macroporous architecture improves mass transport in t-CAs compared to traditional bulk CA as demonstrated by more uniform activation and their response in electrochemical cyclic voltammetry and galvanostatic charge-discharge tests.

36 MATERIALS SCIENCE↗

Experiments and CFD simulation of mass transfer and hydrodynamics in a cylindrical bubble column

Flow visualization, Particle Image Velocimetry (PIV) and dissolved oxygen charging experiments are carried out in a small-scale cylindrical air-water bubble column at different superficial gas velocities. Void fraction profile, total gas holdup, liquid phase velocity field and volumetric mass transfer coefficient are obtained. Details of each experiment are given, with a new procedure for obtaining a 2D void fraction profile from flow visualization by image processing and time averaging which could provide useful information for CFD model validation. The experimental results are analyzed and compared with simulations where good agreement is found for both local and global flow patterns. The averaged governing equations and constitutive relations used in the simulation are discussed briefly, with emphasis on the proper comparison between simulations and experiments based on the derivation of the two-fluid model. Finally, by conducting three sets of experiments related to phase distribution, velocity field and mass transfer in the same apparatus, a validated CFD model for multiphase mass transfer is established and can be used in the future design of a multi-phase reactor.

42 ENGINEERING↗

Global warming potential estimates of mass timber constructions beyond the first life: A dynamic radiative forcing modeling approach

In the face of a warming planet, steps must be taken to reduce the greenhouse gas emissions (GHG) associated with our building industry, which is a significant contributor to global emissions. Large, prefabricated wood elements such as mass timber panels (MTP) have great potential to achieve these reductions as they help displace high-embodied‑carbon materials like concrete and steel. Furthermore, storing the wood's biogenic carbon in buildings benefits the climate because it delays the eventual release of the carbon into the atmosphere. While these climate impacts have been assessed for the construction phase of mass timber buildings, relatively few life cycle assessment (LCA) studies have evaluated the climate impacts for the buildings' end-of-life (EOL) phase. This research estimates the climate impacts of four EOL scenarios for MTP: reusing as MTP, recycling into particleboard, incinerating, and landfilling. Using dynamic radiative forcing modeling and factoring in temporal GHG emissions and biogenic carbon storage, the global warming potential impacts are calculated for construction, deconstruction, and EOL processing of hybrid mass timber buildings in the U.S. Pacific Northwest for 160 years (GWP 160 ). The 160-year temporal scale used in this paper is an arbitrary scale, with the first 80 years being the assumed life of the building, followed by a series of reuse, recycle, or disposal scenarios over the second 80 years of that temporal scale. Of the four EOL scenarios considered in this paper, the ‘reuse’ scenario has the lowest net GWP 160 impact (calculated by summing the GWP 160 and carbon storage benefits, i.e., GWP$^{bioCS}_{160}$ ), emerging as a climate-preferred scenario, followed by ‘landfill’, ‘incinerate’, and ‘recycle’ scenarios. The lower net GWP 160 impact associated with the reuse scenario is due to the low fossil carbon emissions during EOL processing, as well as the biogenic carbon storage benefits. The results of this study also highlight the importance of efficient reuse and recycling strategies for wood in MTP.

42 ENGINEERING↗

Preparation of 241 Am/ 243 Am gravimetric mixtures and development of Am isotopic and assay measurement techniques using thermal ionization mass spectrometry

Three gravimetric mixtures with 241 Am/ 243 Am isotope ratios at nominally 1:1, 20:1, and 200:1 were prepared for calibration of the thermal ionization mass spectrometer instruments used for americium isotopic and assay measurements by isotope dilution mass spectrometry. The total evaporation analytical technique was developed for high-accuracy and precision measurements of Am isotopic ratios. The technique was also applied to Am assay measurements using isotope dilution mass spectrometry. The Am isotope ratio and assay measurement techniques were utilized to characterize batches of americium oxide separated from plutonium materials in storage at Los Alamos National Laboratory in support of commercial use of 241 AmO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Product specific thermal degradation kinetics of bisphenol F epoxy in inert and oxidative atmospheres using evolved gas analysis–mass spectrometry

Knowledge of the degradation kinetics for polymer materials is important for understanding thermal stability. In this study, evolved gas analysis–mass spectrometry and pyrolysis gas-chromatography-mass spectrometry were evaluated for the potential to deliver additional insight into thermal degradation kinetics of diglycidal ether of bisphenol F (DGEBF) epoxy thermoset under inert and oxidative atmospheres. Degradation products of selected precursor ions were evaluated for their uniqueness to the specific precursor using extracted ion thermographs. Unique mass peaks, solely attributed to a single reaction pathway of a specific product, were determined from extracted ion thermographs and used to determine both activation energy (E a ) and pre-exponential factors for the specific primary reaction pathways. These primary reaction pathways for DGEBF epoxy degradation were then evaluated in the context of transition state theory (TST) and related transition state enthalpies (ΔH ‡ ) and entropies (ΔS ‡ ) of activation to further elucidate the degradation process. It was determined under pyrolysis conditions, as suggested by the E a , the formation of bisphenol F monomer was the rate-limiting step toward the formation of xanthene and phenol. In contrast, under thermo-oxidative conditions, reactions involving oxygen containing species were identified as the rate-limiting step for all observed products based on the large negative ΔS ‡ calculated from TST. This work demonstrates a powerful combination of technique and theory that can provide new insight into the degradation of polymer materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-precision measurement of U-Pu-Np-Am concentrations and isotope ratios in environmental reference materials by mass spectrometry

Herein, we report results of precise and sensitive mass spectrometric measurements of uranium, plutonium, neptunium, and americium concentrations and isotope ratios in a variety of environmental reference materials. Most of our work has been done on NIST SRM 4350b, River Sediment, but we also present results for NIST SRM 4354, Lake Sediment; NIST SRMs 4355 and 4355a, Peruvian Soil; NIST SRM 4357, Ocean Sediment; NIST SRM 1648a, Urban Particulate Material; NIST SRM 1649b, Urban Dust; IAEA CRM 385, Ocean Sediment; USGS BCR-2, Columbia River Basalt; and USGS BHVO-2, Hawaiian Volcanic Observatory Basalt. These materials reflect a wide range in long-lived actinide concentrations (e.g. 1E4 to 1E10 atoms 239 Pu/g) and isotope ratios. Measurements were performed in a clean laboratory by isotope dilution, multi-collector thermal ionization and multi-collector inductively coupled plasma mass spectrometry. In general, our results are in agreement with, but lower the uncertainty of, literature or certificate values for these reference materials. Our uranium results for the basalts also confirm previously reported high-precision mass spectrometric results from our laboratory. In many cases our measurements of U-Pu-Np-Am nuclides appear to be novel.

58 GEOSCIENCES↗

Mechanistic mass transfer in hollow fiber membrane solvent extraction for bio-based isobutanol

Membrane solvent extraction (MSE) has emerged as a promising method for selectively recovering bioproducts from complex aqueous streams. Bio-isobutanol, a next-generation feedstock for biofuel, remains challenging to recover because of its low concentration and the presence of inhibitory substances. This study explores the potential of hollow fiber (HF) MSE for bio-isobutanol recovery and systematically examines the coupled effects of fiber packing, shell-side flow dynamics, and aqueous chemistry on performance. A resistance-in-series model is applied to understand mass transfer in the HF MSE modules, quantify local resistances, and validate overall performance. The results show that increasing the fiber packing provides a larger interfacial area but induces poor flow distribution and channeling, hindering effective isobutanol transport. Meanwhile, increasing the shell-side velocity improves isobutanol recovery due to reductions in the boundary layer thickness. The presence of salts, added to mimic fermentation broth, increases the partition coefficient through salting-out effects, further improving isobutanol flux. A modified correlation for the shell-side mass transfer coefficient (k s,ϕ+v ), integrating geometric and hydrodynamic effects, was developed and validated. The proposed model achieves highly predictive accuracy (r 2 = 0.9808) across a wide range of conditions, outperforming previous models. The findings provide mechanistic insight into the interaction of geometric packing, hydrodynamics, and chemistry in governing mass transfer in HF MSE. Overall, this work demonstrates the potential of HF MSE for efficient bio-isobutanol recovery and also provides practical guidelines on critical factors (packing fraction, partition coefficient, and shell-side velocity), aiding in the design and scaling of MSE systems for resource recovery.

Aqueous chemistry↗

Gaussian mixture model clustering algorithms for the analysis of high-precision mass measurements

The development of the phase-imaging ion-cyclotron resonance (PI-ICR) technique for use in Penning trap mass spectrometry (PTMS) increased the speed and precision with which PTMS experiments can be carried out. In PI-ICR, data sets of the locations of individual ion hits on a detector are created showing how ions cluster together into spots according to their cyclotron frequency. Ideal data sets would consist of a single, 2D-spherical spot with no other noise, but in practice data sets typically contain multiple spots, non-spherical spots, or significant noise, all of which can make determining the locations of spot centers non-trivial. A method for assigning groups of ions to their respective spots and determining the spot centers is therefore essential for further improving precision and confidence in PI-ICR experiments. Here, we present the class of Gaussian mixture model (GMM) clustering algorithms as an optimal solution. We show that on simulated PI-ICR data, several types of GMM clustering algorithms perform better than other clustering algorithms over a variety of typical scenarios encountered in PI-ICR. The mass spectra of 163Gd, 163 mGd, 162 Tb, and 162 mTb measured using PI-ICR at the Canadian Penning trap mass spectrometer were checked using GMMs, producing results that were in close agreement with the previously published values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-Imaging Ion-Cyclotron-Resonance mass spectrometry with the Canadian Penning Trap at CARIBU

The Canadian Penning Trap mass spectrometer (CPT) has conducted precision mass measurements of neutron-rich nuclides from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) of the Argonne Tandem Linac Accelerator System (ATLAS) facility at Argonne National Laboratory using the Phase-Imaging Ion-Cyclotron-Resonance (PI-ICR) technique for over half a decade. Here, in this study, we discuss the CPT system, and methods to improve accuracy and precision in mass measurement using PI-ICR including some optimization techniques and recently studied systematic effects.

Penning trap mass spectrometry↗

Strong coupling constant and quark masses from lattice QCD

In this paper, we review lattice determinations of the charm- and bottom-quark masses and the strong coupling constant obtained by different methods. We explain how effective field theory approaches, such as Non-Relativistic QCD (NRQCD), potential Non-Relativistic QCD (pNRQCD), Heavy Quark Effective Theory (HQET) and Heavy Meson rooted All- Staggered Chiral Perturbation Theory (HMrASχPT) can help in these determinations. After critically reviewing different lattice results we determine lattice world averages for the strong coupling constant, $α_s(M_Z, N_f=5) = 0.11803^{+0.00047}_{–0.00068}$, as well as for the charm-quark mass, $m_c(m_c, N_f=4) = 1.2735(35)$ GeV, and the bottom-quark mass, $m_b(m_b, N_f=5) = 4.188(10)$ GeV. The above

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of phosphorus and sulfur in uranium ore concentrates by triple quadrupole inductively coupled plasma mass spectrometry

The analysis of impurities in a uranium ore concentrate (UOC) could provide information regarding the source, production history, and potential intended use of the UOC. This study involves the analysis of UOC samples for phosphorus and sulfur. Here, concentrations were determined by triple quadrupole inductively coupled plasma – mass spectrometry and compared with results from a pyrohydrolysis method as well as previously reported results. The sulfur and phosphorus concentrations, determined by the mass spectrometer, were used to explore possible trends in a series of UOC material, and the uncertainties were calculated using GUM workbench software. The triple quadrupole inductively coupled plasma – mass spectrometer method allows for the removal of interferences in the analysis of species.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

mzapy : An Open-Source Python Library Enabling Efficient Extraction and Processing of Ion Mobility Spectrometry-Mass Spectrometry Data in the MZA File Format

We have recently reported MZA, a new and simple mass spectrometry data structure based on the broadly supported HDF5 format and created to facilitate software development. While this format is inherently supportive of application development, the availability of a core library with standard mass spectrometry utilities greatly facilitates fast software development. Here, we present a Python library, mzapy, for efficient extraction and processing of mass spectrometry data in the MZA format. In addition to raw data extraction, mzapy contains supporting utilities enabling tasks including calibration, signal processing, peak finding, and generating plots. Being implemented in pure Python with minimal and largely standardized dependencies makes mzapy uniquely suited to application development in the multi-omics domain. The free and open source mzapy is built with extensibility in mind, and future development will support cloud computing and artificial intelligence/machine learning applications. The software source code is freely available at https://github.com/PNNL-m-q/mzapy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid Droplet Sampling Interface for Low-Volume, High-Throughput Mass Spectrometry Analysis

Here, we present a rapid droplet sampling interface (RDSI) electrospray ionization mass spectrometry (ESI-MS) system as a high-throughput, low-volume, noncontact, and minimal-carryover approach for characterization of liquids. Liquid characterization was achieved by combining droplet ejection with an open-face microflow capillary with a 2.5 μL/min continuous flow of carrier solvent. Through this implementation, single 0.3 nL droplets containing the analyte effectively mix with 4–8 nL of carrier solvent and create a combined electrospray plume. The carrier solvent continuously cleaned the system, eliminating carryover. A sampling rate of 5 Hz was achieved for droplets containing 1 μM propranolol or 5 μM leu-enkephalin with each droplet fully baseline-resolved (138 ± 32 ms baseline-to-baseline). Using a SCIEX API4000 mass spectrometer, a lower limit of quantification (LLOQ) of propranolol was 15 nM, corresponding to 1.16 fg of propranolol in the droplet, and was linear across 3 orders of magnitude. Further, quantitation could be achieved by adding an isotopically labeled internal standard, as done in conventional ESI. Signal transients were faster than the acquisition speed of the mass spectrometer, resulting in artificially high reproducibility of 15–30% RSD droplet-to-droplet. Analyte–solvent mixing ratios could be controlled by adjusting droplet positioning along the open-face capillary with an optimal position about 0.4 mm from the tip end. The range of analyte coverage was exemplified by measures of peptides and drugs in methanol, water, and buffer solutions. In a comparison to the Open Port Sampling Interface (OPSI) implemented on the same system, the RDSI had 78× greater sensitivity, 6× greater throughput and used significantly less carrier solvent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MZA: A Data Conversion Tool to Facilitate Software Development and Artificial Intelligence Research in Multidimensional Mass Spectrometry

Modern mass spectrometry-based workflows employing hybrid instrumentation and orthogonal separations collect multidimensional data, potentially allowing deeper understanding in omics studies through adoption of artificial intelligence methods. However, the large volume of these rich data challenges existing data storage and access technologies, therefore precluding informatics advancements. Here we present MZA™ (pronounced m-za), the mass-to-charge (m/z) generic data storage and access tool designed to facilitate software development and artificial intelligence research in multidimensional mass spectrometry measurements. Composed by a data conversion tool and a simple file structure based on the HDF5 format, MZA provides easy, cross-platform and efficient programmatic access to raw MS-data, enabling fast development of new tools in data science programming languages such as Python and R. The software executable and example Python and R scripts are freely available at https://github.com/PNNL-m-q/mza.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Approaching Angstrom-Scale Resolution in Lithography Using Low-Molecular-Mass Resists (<500 Da)

Resists that enable high-throughput and high-resolution patterning are essential in driving the semiconductor technology forward. The ultimate patterning performance of a resist in lithography is limited because of the trade-off between resolution, line-width roughness, and sensitivity; improving one or two of these parameters typically leads to a loss in the third. As the patterned feature sizes approach angstrom scale, the trade-off between these three metrics becomes increasingly hard to resolve and calls for a fundamental rethinking of the resist chemistry. Low-molecular-mass monodispersed metal-containing resists of high atom economy can provide not only very high resolution but also very low line-width roughness without sacrificing sensitivity. Here we describe a modular metal-containing resist platform (molecular mass <500 Da) where a molecular resist consists of just two components: a metal and a radical initiator bonded to it. This simple system not only is amenable to high-resolution electron beam lithography (EBL) and extreme ultraviolet lithography (EUVL) but also unites them mechanistically, giving a consolidated perspective of molecular and chemical processes happening during exposure. Irradiation of the resist leads to the production of secondary electrons that generate radicals in the initiator bonded to metal. This brings about an intramolecular rearrangement and causes solubility switch in the exposed resist. We demonstrate record 1.9–2.0 nm isolated patterns and 7 nm half-pitch dense line-space features over a large area using EBL. With EUVL, 12 nm half-pitch line-space features are shown at a dose of 68 mJ/cm 2 . In both of these patterning techniques, the line-width roughness was found to be ≤2 nm, a record low value for any resist platform, also leading to a low-performance trade-off metric, Z factor, of 0.6 × 10 –8 mJ·nm 3 . With the ultimate resolution limited by instrumental factors, potential patterning at the level of a unit cell can be envisaged, making low-molecular-mass resists best poised for angstrom-scale lithography.

77 NANOSCIENCE AND NANOTECHNOLOGY↗