Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

The Biological Effectiveness of Accelerated Particles for the Induction of Chromosome Damage: Track Structure Effects and Cytogenetic Signatures of High-LET Exposure

Track structure models predict that at a fixed value of LET, particles with lower charge number, Z will have a higher biological effectiveness compared to particles with a higher Z. In this report we investigated how track structure effects induction of chromosomal aberration in human cells. Human lymphocytes were irradiated in vitro with various energies of accelerated iron, silicon, neon, or titanium ions and chromosome damage was assessed in using three color FISH chromosome painting in chemically induced PCC samples collected a first cell division post irradiation. The LET values for these ions ranged from 30 to 195 keV/micrometers. Of the particles studied, Neon ions have the highest biological effectiveness for induction of total chromosome damage, which is consistent with track structure model predictions. For complex-type exchanges 64 MeV/ u Neon and 450 MeV/u Iron were equally effective and induced the most complex damage. In addition we present data on chromosomes exchanges induced by six different energies of protons (5 MeV/u to 2.5 GeV/u). The linear dose response term was similar for all energies of protons suggesting that the effect of the higher LET at low proton energies is balanced by the production of nuclear secondaries from the high energy protons. All energies of protons have a much higher percentage of complex-type chromosome exchanges than gamma rays, signifying a cytogenetic signature for proton exposures.

George, K.↗

A Specialized Ultrasound Protocol for NASA's Renal Stone Surveillance and Clinical Practice

INTRODUCTION Ample evidence exists on the effectiveness of ultrasound in the diagnosis of kidney stones. However, terrestrial practice is mostly concerned with diagnosis of clinically significant urolithiasis. Adapting this non-irradiating, low-cost imaging modality for the asymptomatic astronaut population offers high-sensitivity screening and limits their career radiation dose. METHODS NASA developed a novel ultrasound-based detection and surveillance protocol to identify, categorize, and monitor mineralized renal material (MRM) in astronauts. The term MRM was developed to denote abnormal, presumably calcified, focal material of unknown clinical significance in the kidneys. Sonographic criteria for MRMs include measurable echogenic foci, their detectability in multiple, designated imaging plains, posterior shadowing, and “twinkle” pattern visualized in Color Doppler and/or demonstrated in Spectral Doppler modes. The mere discovery of an MRM does not trigger further imaging or intervention, unless the affected crewmember is mission-assigned, or the MRM meets actionable criteria based on size, location, and sonographic characteristics. If the threshold is met, the crew surgeon is notified, and additional diagnostic imaging and urology consultation are considered. RESULTS In total, 73 individuals have been scanned using our specialized methods, 60 have had more than one study done. As of April 2023, 282 total studies have been performed. So far, over 30 pairs of pre-and postflight studies have been obtained, and the findings are presented elsewhere in this panel. DISCUSSION A surveillance program was initiated nine years ago to screen asymptomatic members of the astronaut corps for renal calcifications, from their initial hiring, through their mission timeframes, and throughout their career. The goal is to reduce the probability that an astronaut will fly with a renal stone that may become symptomatic. This also gives NASA the information it needs to improve screening criteria for future long-duration crewed missions.

H Lyons↗

Radiation Transport Modeling and Assessment to Better Predict Radiation Exposure, Dose, and Toxicological Effects to Human Organs on Long Duration Space Flights

NASA's long-range plans include possible human exploratory missions to the moon and Mars within the next quarter century. Such missions beyond low Earth orbit will expose crews to transient radiation from solar particle events which include high-energy galactic cosmic rays and high-energy protons. Because the radiation levels in space are high and the missions long, adequate shielding is needed to minimize the deleterious health effects of exposure to radiation. The focus of this study is radiation exposure to the blood-forming organs of the NASA astronauts. NASA/JSC developed the Phantom Torso Experiment for Organ Dose Measurements which housed active and passive dosimeters that would monitor and record absorbed radiation levels at vital organ locations. This experiment was conducted during the STS-9 I mission in May '98 and provided the necessary space radiation data for correlation to results obtained from the current analytical models used to predict exposure to the blood-forming organs. Numerous models (i.e., BRYNTRN and HZETRN) have been developed and used to predict radiation exposure. However, new models are continually being developed and evaluated. The Space Environment Information Systems (SPENVIS) modeling program, developed by the Belgian Institute for Space Aeronomy, is to be used and evaluated as a part of the research activity. It is the intent of this research effort to compare the modeled data to the findings from the STS-9 I mission; assess the accuracy and efficiency of this model; and to determine its usefulness for predicting radiation exposure and developing better guidelines for shielding requirements for long duration manned missions.

Denkins, Pamela↗

Nuclear emulsion measurements of the astronauts' radiation exposure on the Apollo-Soyuz mission

On the Apollo-Soyuz mission each astronaut carried one passive dosimeter containing nuclear photographic emulsions, plastic foils, TLD chips, and neutron-activation foils for recording radiation exposure. This report is limited to the presentation of data retrieved from nuclear emulsions. Protons, most of them trapped particles encountered in numerous passes through the South Atlantic Anomaly, contributed by far the largest share to the mission dose. Their linear energy transfer (LET) spectrum was established from track and grain counts in a G.5 emulsion which is used for medium and high energies, and from ender counts in a K.2 emulsion which is used for low energies. The total mission fluence of protons was found to be equivalent to a unidirectional beam of 448,500 square centimeters. The broad spectrum was broken down into small LET intervals, which allowed for the computation of absorbed doses and dose equivalents. The totals are 51 millirad and 74 millirem. Counts of disintegration stars in K.2 emulsion are incomplete at present. While a total of 467 stars were identified, counting their prong numbers is still in progress. It was concluded that the Apollo-Soyuz astronauts' radiation exposure as such did not contain anything out of the ordinary that would seem to require special attention.

Schaefer, H. J.↗

Dose reconstruction for individuals exposed to ionizing radiation using chromosome painting

To be most useful, a biomarker for dose reconstruction should employ an end point that is highly quantitative, stable with time and easily measured. Reciprocal translocations have been shown to be a promising biomarker that is linked to both prior exposure and risk, and they can be measured easily and quantitatively using fluorescence in situ hybridization. In contrast to other biomarkers that are available, the frequency of reciprocal translocations in individuals exposed to whole-body radiation is stable with time after exposure, has rather small interindividual variability and can be measured accurately at low levels of exposure. Results from recent studies demonstrate that measurements of reciprocal translocation frequencies, facilitated by chromosome painting, can be used to reconstruct radiation dose for individuals exposed in the distant past.

NASA Discipline Radiation Health↗

Dexamethasone effects on creatine kinase activity and insulin-like growth factor receptors in cultured muscle cells

The effect of dexamethasone on the activity of creatine kinase (CK) and the insulin-like growth factor I (IGF-I) binding were investigated using skeletal- and cardiac-muscle-derived cultured cell lines (mouse, C2C12; rat, L6 and H9c2). It was found that, in skeletal muscle cells, dexamethasone treatment during differentiation of skeletal-muscle cells caused dose-dependent increases in CK activity and increases in the degree of myotube formation, whereas cardiac cells (H9c2) exhibited very low CK activity during culture or dexamethasone treatment. Results for IGF-I binding were similar in all three cell lines. The IGF-I binding to dexamethasone-treated cells (50 nM for 24 hr on the day prior to confluence) resulted in an increased number of available binding sites, with no effect on the binding affinities.

Whitson, Peggy A.↗

Buried Oxide Densification for Low Power, Low Voltage CMOS Applications

Special technology and circuit architecture are of growing interest for implementation of circuits which operate at low supply voltages and consume low power levels without sacrificing performance[1]. Use of thin buried oxide SOI substrates is a primary approach to simultaneously achieve these goals. A significant aspect regarding SIMOX SOI for low voltage, low power applications is the reliability and performance of the thin buried oxide. In addition, when subjected to high total dose irradiation, the silicon islands within the BOX layer of SIMOX can store charges and significantly effect the back channel threshold voltages of devices. Thus, elimination of the islands within the buried oxide (BOX) layer is preferred in order to prevent leakage through these conductive islands and charge build-up within the buried oxide layer. A differential (2-step) ramp rate as applied to full and 100 nm BOX SIMOX was previously reported to play a significant role in the stoichiometry and island formation within the buried layer[2]. This paper focus is on the properties of a thin (120nm) buried oxide as a function of the anneal ramp rate and the temperature of anneal. In this research, we have found an improvement in the buried oxide stoichiometry with the use of a slower, singular ramp rate for specified thin buried oxides, with slower ramp rates and higher temperatures of anneal suggested for reducing the presence of Si islands within the BOX layer.

Allen, L. P.↗

Kinetics of chromatid break repair in G2-human fibroblasts exposed to low- and high-LET radiations

The purpose of this study is to determine the kinetics of chromatid break rejoining following exposure to radiations of different quality. Exponentially growing human fibroblast cells AG1522 were irradiated with gamma-rays, energetic carbon (290 MeV/u), silicon (490 MeV/u) and iron (200 MeV/u, 600 MeV/u). Chromosomes were prematurely condensed using calyculin A. Prematurely condensed chromosomes were collected after several post-irradiation incubation times, ranging from 5 to 600 minutes, and the number of chromatid breaks and exchanges in G2 cells were scored. The relative biological effectiveness (RBE) for initial chromatid breaks per unit dose showed LET dependency having a peak at 55 keV/micrometers silicon (2.4) or 80 keV/micrometers carbon particles (2.4) and then decreased with increasing LET. The kinetics of chromatid break rejoining following low- or high-LET irradiation consisted of two exponential components. Chromatid breaks decreased rapidly after exposure, and then continued to decrease at a slower rate. The rejoining kinetics was similar for exposure to each type of radiation, although the rate of unrejoined breaks was higher for high-LET radiation. Chromatid exchanges were also formed quickly.

NASA Center JSC↗

Improved analysis of electron penetration and numerical procedures for space radiation shielding

Electron penetration calculational techniques are reviewed with regard to their suitability for shield analysis in future space operations. Methods based on the transmission factors of Mar are discussed and a correction term for low-energy electrons, which results in slightly conservative shield estimates, is derived. This modified Mar's method provides estimates of the dose for electrons that penetrate through shields of arbitrary elemental material with an atomic number greater than four. A complete computer algorithm is included.

Wilson, J. W.↗

Effect of gamma irradiation on the friction and wear of ultrahigh molecular weight polyethylene

The effect of sterilization gamma irradiation on the friction and wear properties of ultrahigh molecular weight polyethylene (UHMWPE) sliding against stainless steel 316L in dry air at 23 C is investigated, the results to be used in the development of artificial joints which are to surgically replace diseased human joints. A pin-on-disk sliding friction apparatus is used, a constant sliding speed in the range 0.061-0.27 m/s is maintained, a normal load of 1 kgf is applied with dead weight, and the irradiation dose levels are: 0, 2.5, and 5.0 Mrad. Wear and friction data and conditions for each of the ten tests are summarized, and include: (1) wear volume as a function of the sliding distance for the irradiation levels, (2) incremental wear rate, and (3) coefficient of friction as a function of the sliding distance. It is shown that (1) the friction and wear properties of UHMWPE are not significantly changed by the irradiation doses of 2.5 and 5.0 Mrad, (2) the irradiation increases the amount of insoluble gel as well as the amount of low molecular weight material, and (3) after run-in the wear rate is either steady or gradually decreases as a function of the sliding distance.

Jones, W. R.↗

A radiation hardened 256 x 4 bulk CMOS RAM

A radiation hardened version of the C2L process has been developed that utilizes all-low-temperature processes subsequent to channel oxidation. This process has been used on 1K RAMS. The RAMs functioned reliably at a dose of 200,000 rads (Si) and failed at a dose of 500,000 rads (Si). The 1K RAM is capable of operating from 7.5 to 12 volts and has an access time from address change of 160 nsec at 10 volts

Napoli, L. S.↗

Anabolic Responses of an Adult Cancellous Bone Site to Prostaglandin E2 in the Rat

The objects of this study were to determine: (1) the response of a non-growing cancellous bone site to daily prostaglandin E2 (PGE2) administration; and (2) the differences in the effects of daily PGE2, administration in growing (proximal tibial metaphysis, PTM) and non-growing cancellous bone sites (distal tibial metaphysis, DTM). Seven-month-old male Sprague-Dawley rats were given daily subcutaneous injections of 0, 1, 3 and 6 mg PGE2/kg per day for 60, 120 and 180 days. The static and dynamic histomorphometric analyses were performed on double-fluorescent labeled undecalcified distal tibial metaphyses (DTM). No age-related changes were found in static and dynamic histomorphometry of DTM cancellous bone between 7 and 13 months of age. The DTM of 7-month-old (basal controls) rats consisted of a 24.5 +/- 7.61%-metaphyseal cancellous bone mass, and a thick trabeculae (92 +/- 12 micro-m). It also had a very low tissue-base bone formation rate (3.0 +/- 7.31%/year). Exogenous PGE2 administration produced the following transient changes in a dose-response manner between zero and 60 days: (1) increased trabecular bone mass and improved architecture (increased trabecular bone area, width and number, and decreased trabecular separation); (2) increased trabecular interconnections: (3) increased bone formation parameters; and (4) decreased eroded perimeter. A new steady state with more cancellous bone mass and higher bone turnover was observed from day 60 onward, The elevated bone mass induced by the first 60 days of PGE2 treatment was maintained by another 60 and 120 days with continuous daily PGE2 treatment. When these findings were compared to those previously reported for the PTM, we found that the DTM was much more responsive to PGE2 treatment than the PTM. Percent trabecular bone area and tissue based bone formation rate increased significantly more in DTM as compared to PTM after the 60 days of 6 mg PGE2 treatment. These observations indicate that a non-growing cancellous bone site is more responsive than growing bone site to long-term daily administration of PGE2.

Ito, Hiroshi↗

Advanced Multifunctional MMOD Shield: Radiation Shielding Assessment

As NASA is looking to explore further into deep space, multifunctional materials are a necessity for decreasing complexity and mass. One area where multifunctional materials could be extremely beneficial is in the micrometeoroid orbital debris (MMOD) shield. A typical MMOD shield on the International Space Station (ISS) is a stuffed whipple shield consisting of multiple layers. One of those layers is the thermal blanket, or multi-layer insulation (MLI). By increasing the MMOD effectiveness of MLI blankets, while still preserving their thermal capabilities, could allow for a less massive MMOD shield. Thus, a study was conducted to evaluate concept MLI blankets for MMOD shields. In conjunction, these MLI blankets and the subsequent MMOD shields were also evaluated for their radiation shielding effectiveness towards protecting crew. These concepts were evaluated against the ISS MLI blankets and the ISS MMOD shield, which acted as the baseline. These radiation shielding assessments were performed using the high charge and energy transport software (HZETRN). This software is based on a one-dimensional formula of the Boltzmann transport equation with a straight-ahead approximation. Each configuration was evaluated against the following environments to provide a diverse view of radiation shielding effectiveness in most space environments within the heliosphere: August 1972 solar particle event, October 1989 solar particle event, 1982 galactic cosmic ray environment (during solar maximum), 1987 galactic cosmic ray environment (during solar minimum), and a low earth orbit environment in 1970 that corresponded to an altitude of 400 km and inclination of 51.6 . Both the absorbed dose and the dose equivalent were analyzed, but the focus of the discussion was on the dose equivalent since the data is most concerned with radiation shielding of the crew. The following paper outlines the evaluations performed and discusses the results and conclusions of this evaluation for radiation shielding effectiveness. Future work will focus on optimizing the radiation shielding properties for the MMOD shield. Submission

Rojdev, Kristina↗

It's All Relative: A Validation of Radiation Quality Comparison Metrics

The difference between high-LET and low-LET radiation is quantified by a measure called relative biological effectiveness (RBE). RBE is defined as the ratio of the dose of a reference radiation to that of a test radiation to achieve the same effect level, and thus, is described either as an iso-effector dose-to-dose ratio. A single dose point is not sufficient to calculate an RBE value; therefore, studies with only one dose point usually calculate an effect-to-effect ratio. While not formally used in radiation protection, these iso-dose values may still be informative. Shuryak, et al 2017 investigated the use of an iso-dose metric termed "radiation effects ratio" (RER) and used both RBE and RER to estimate high-LET risks. To apply RBE or RER to risk prediction, the selected metric must be uniquely defined. That is, the calculated value must be consistent within a model given a constant set of constraints and assumptions, regardless of how effects are defined using statistical transformations from raw endpoint data. We first test the RBE and the RER to determine whether they are uniquely defined using transformations applied to raw data. Then, we test whether both metrics can predict heavy ion response data after simulated effect size scaling between human populations or when converting animal to human endpoints.

Chappell, Lori J.↗

Antimicrobial Resources for Disinfection of Potable Water Systems for Future Spacecraft

As human exploration adventures beyond low earth orbit, life support systems will require more innovation and research to become self-sustaining and durable. One major concern about future space travel is the ability to store and decontaminate water for consumption and hygiene. This project explores materials and technologies for possible use in future water systems without requiring point-of-use (POU) filtering or chemical additives such as iodine or silver that require multiple doses to remain effective. This experimentation tested the efficacy of a variety of antimicrobial materials against biofilm formation in a high shear CDC Biofilm Reactor (CBR) and some materials in a low shear Drip Flow Reactor (DFR) which(also utilizes ultra violet light emitting diodes (UVLEDs) as an antimicrobial resource. Most materials were tested in the CBR using the ASTM E 2562-07 1method involving the Pseudomonas aeruginosa and coupon samples that vary in their antimicrobial coatings and surface layer topographies. In a controlled environmental chamber (CEC), the CBR underwent a batch phase, continuous flow phase (CFP), and a harvest before analysis. The DFR portion of this experimentation was performed in order to assess the antimicrobial capabilities of ultraviolet-A LEDs (UV-A) in potable water systems. The ASTM E 2647-08 was modified in order to incorporate UV-A LEDs and to operate as a closed, re-circulating system. The modified DFR apparatus that was utilized contains 4 separate channels each of which contain 2 UV-A LEDs (1 chamber is masked off to serve as a control) and each channel is equipped with its own reservoir and peristaltic pump head. The 10 DFR runs discussed in this report include 4 initial experimental runs that contained blank microscope slides to test the UVA LEDs alone, 2 that incorporated solid silver coupons, 2 that utilized titanium dioxide (Ti02) coupons as a photocatalyst, and 2 runs that utilized silver coated acrylic slides. Both the CBR and DFR experiments were analyzed for microbial content via heterotrophic plate counts (HPC) and acridine orange direct counts (AODC). Ofthe materials used in the CBR, only two materials performed as anti~icrobials under high shear conditions (a reduction of 5 or more logs) showing a>7 log reduction in viable microbes.

Morford, Megan A.↗

Improving Efficacy and Safety of Pharmacological Treatment Through Precision Health and Pharmacogenomics

INTRODUCTION: Future spaceflight will require increased crew medical autonomy as exploration class missions expand in duration and distance from Earth, especially for Mars missions. As mission duration increases, it will be essential to have appropriate amounts of effective medication to ensure the maintenance of crew health and performance. Conversely, mass and volume constraints will become more severe as future spaceflight expands beyond low Earth orbit, where resupply is difficult or becomes impossible. These constraints thus convey an urgency to tailor medications for individual crewmembers and further examine appropriate dosing regimens. BACKGROUND: Precision Health is an exciting area of medicine focused on maintaining an individual’s health and performance through in-depth understanding of an individual’s unique clinical and environmental history, genetic makeup, and molecular profiles. This approach can be adapted to better predict, monitor, and address physiological responses to the spaceflight environment. A subset of this field is pharmacogenomics (PGX), the study of how the expressed genome impacts drug responses with the goal of prescribing the right dose of the right drug at the right time. Specifically, PGX testing provides valuable information on an individual’s precise allelic variations to guide physicians in making informed decisions on drug choice and dosing to avoid adverse events and maximize efficacy. The study goal was to identify which current space pharmacy drugs could be evaluated using PGX testing and to understand the potential impact on the health and wellness of the astronaut population. Additionally, we sought to evaluate clinically available FDA-approved PGX testing solutions to better understand its applicability. METHODS: A complete list of drugs on the ISS was analyzed for risk and likelihood of drug failure and PGX actionability. This analysis encompassed both astronauts’ personal medications, including supplements and over the counter drugs (n=151) contained in the ISS medical accessory kit (IMAK), and ISS MedKit formulary medications (n=95). Duplicate medications and different formulations were removed, which resulted in a total of 157 drugs used in the subsequent analysis. A 5x5 risk assessment table was produced by examining the likelihood of drug failure compared to the consequence of drug failure (LxC). Likelihood of individual drug failure was defined by whether existing processes are sufficient to prevent ineffective treatment or impactful side effect events, as ranked from 1 (very low, can easily be prevented) to 5 (very high, cannot be prevented) during a Mars mission. In contrast, the consequence of drug failure was defined by impact to safety, schedule, cost, or technical criteria and ranked from 1 (very low) to 5 (very high). An assessment of PGX reference laboratories is currently underway to evaluate sample requirements, benefit analysis (cost vs. utility of allele variant analysis), relevance to inflight medication usage, quality of reporting in enabling clinical application, and ease of integration into electronic medical records. RESULTS: Risk assessments (LxC 5x5 table) indicated 128 medications were in the green zone where risk is acceptable, with the remaining 29 of the medications in the yellow or red zone driven predominantly due to drug failure or safety concerns. We found that current PGX testing results could impact 21% of the total medications in the ISS MedKit and IMAK; of these, 9 medications currently have direct clinically actionable guidance available. Results of the clinical PGX solution evaluations as related to these medications will be presented. CONCLUSION: PGX testing has demonstrated clear benefits in terrestrial medicine and clinical environments for the selection of proper medications, avoiding adverse drug reactions, and maximizing drug efficacy. We propose that similar benefits would be bestowed on the astronaut and commercial spaceflight passenger population by performing preemptive preflight PGX testing to reduce risk of mission failure due to ineffective or toxic medications, improve drug efficacy, and further open the door to countermeasure research. For example, PGX results could allow tailoring of specific medications at optimal doses more precisely to each individual astronaut, particularly in areas of space motion sickness, sleep aids, and analgesics. An additional benefit is that PGX results could provide information for better planning of the components of a space pharmacy for deep space missions to be more effective and efficient in the utilization of limited pharmaceutical resources. Finally, while PGX testing of the astronaut corps is not currently conducted, this approach could provide immediate impact in support of mission success by reducing risks, optimizing astronaut performance, and providing valuable insights into long-term astronaut health. Such advancements in clinical decision making are important next steps in building dynamic individual risk profiles for astronauts, increasing selection of the best treatment choice, and providing tailored countermeasures for individual crewmembers.

Pharmacogenomics↗

A radiation-hard, low-background multiplexer design for spacecraft imager applications

A possible multiplexer design for the focal plane for the Cassini Visible and Infrared Mapping Spectrometer (VIMS) is reviewed. The instrument's requirements for the multiplexed array are summarized. The VIMS instrument has a modest radiation-hardness requirement due to the trajectory and planetary environments in which the instrument will be required to operate. The total ionizing dose hardness requirement is a few tens of kilorads. A thin-gate oxide of a few hundred angstroms thickness is to be used. Field hardness is to be achieved by guard bands or hardened dielectric isolation. The design is argued to meet the low-noise and radiation-hardness required for imaging at Saturn. The design is versatile enough to provide double-correlated and double-uncorrelated sampling, which is accomplished in the signal processing electronics outside the focal plane.

Staller, Craig↗

Effects of high-LET particles /A-40/ on the brain of Drosophila melanogaster

To investigate the effects of galactic heavy particles on nervous tissue, Drosophila melanogaster flies were exposed to A-40 from the Super-HILAC accelerator at the Lawrence Berkeley Laboratory. The energy of the particles reaching the Drosophila neurons was 4.8 MeV/nucleon, and the fluence ranged from 60,000 to 80 million particles/sq cm. Thirty-five days after irradiation at the higher fluences, extensive tissue fragmentation and cysts were found. At fluences as low as one hit/two cell bodies (about 5 million) and one hit/90 cell bodies (about 90,000 particles/sq cm or 21 rad average dose) swelling of neuronal cytoplasm and focally fragmented membranes were noted; at fluences ranging from one hit/six to one hit/135 cell bodies, there was frequently a marked increase in glial lamellae around nerve-cell processes, which often had degenerative features. These findings support the view that single hits by heavy particles may injure nervous tissue.

Miquel, J.↗