Effects of Power Reserve Control on Wind Turbine Structural Loading
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
This paper developed an algorithm that controls the supply air temperature in the variable refrigerant flow (VRF), outdoor air processing unit (OAP) system, according to indoor and outdoor temperature and humidity, and verified the effects after applying the algorithm to real buildings. The VRF-OAP system refers to a heating, ventilation, and air conditioning (HVAC) system to complement a ventilation function, which is not provided in the VRF system. It is a system that supplies air indoors by heat treatment of outdoor air through the OAP, as a number of indoor units and OAPs are connected to the outdoor unit in the VRF system simultaneously. This paper conducted experiments with regard to changes in efficiency and the cooling capabilities of each unit and system according to supply air temperature in the OAP using a multicalorimeter. Based on these results, an algorithm that controlled the temperature of the supply air in the OAP was developed considering indoor and outdoor temperatures and humidity. The algorithm was applied in the test building to verify the effects of energy reduction and the effects on indoor temperature and humidity. Loads were then changed by adjusting the number of conditioned rooms to verify the effect of the algorithm according to various load conditions. In the field test results, the energy reduction effect was approximately 15–17% at a 100% load, and 4–20% at a 75% load. However, no significant effects were shown at a 50% load. The indoor temperature and humidity reached a comfortable level.
Changes in fluid pressure deform porous media and this effect occurs in a variety of hydrogeologic processes, from the change in storage during pumping or injection to fluctuations in water levels caused by barometric pressure. We have developed instruments for measuring small strains in porous media, and we have used the resulting strain data to evaluate well testing, hydraulic fracturing, manual loading at the ground surface, and ambient hydrologic processes, like rainfall and evaporation. A particularly important application is the use of strain tensor data measured at shallow depths to analyze well tests or hydraulic fractures conducted at much greater depths. An early demonstration of this technique was conducted at the North Avant Field north of Tulsa, Oklahoma, where Pennsylvanian sandstone creates a confined aquifer and oil reservoir at a depth of 530m. We have showed that the strains caused by injecting into the aquifer could be measured at a depth of 30m and used to evaluate the properties of the aquifer. We recently expanded the array of strainmeters at the North Avant Field by deploying three more instruments at shallow depth (30m) along with a deep instrument at 520m depth in the winter, 2021. The deep instrument is deployed in shale caprock slightly above the aquifer. To our knowledge, the deep strainmeter at the North Avant Field is the deepest strainmeter ever deployed and this required refining methods originally developed for shallow deployments. The instrument was lowered to depth on oil field tubing and cemented in place using techniques and materials developed for use in oil wells. Optical fiber used to communicate with the instrument was cemented in the annulus on the outside of tubing. This is significant because the techniques we used could readily be extended to greater depth, suggesting that strainmeters can be deployed over a wide range of depths for monitoring critical subsurface processes. For example, it suggests that strainmeters could be deployed through the caprock to monitor for leaks from underlying CO2 storage reservoirs. The strainmeter array at the North Avant Field has been used to characterize deformation during a series of injection tests in the spring and summer, 2021. All the new strainmeters respond to pumping, and the strainmeters we installed earlier also responded. To our knowledge, this is the first application of well testing in a deep aquifer that was monitored by an array of strainmeters—our earlier work used strainmeters at a single location. We are currently analyzing the strain data using an analytical solution, a proxy-based Bayesian inversion algorithm, and other methods. Strainmeter data has also been used to characterize periodic pumping tests by us and Riley Blais. A periodically varying pumping rate causes both hydraulic head and strain signals that vary with the same period as the pumping. The peaks and troughs of the head in monitoring wells lag behind the peaks and troughs of the head in the pumping well, and this lag time increases with distance from the pumping well. The lag time of the pressure and the distance to the monitoring well can be used in a simple analysis to estimate the hydraulic diffusivity of the aquifer. The lag time determined from strain data can be used to estimate aquifer properties using the same analysis that works for the pressure only for strain data measured at particular locations. That is because the strain field in a confining unit advances upward, laterally and then downward even though the pressure in the underlying aquifer only advances laterally, according to our recent simulations. We have field data showing that a small periodic signal superimposed on an injection rate at the North Avant Field will create a periodic strain signal at shallow strainmeters. The field data and the recent simulations suggest that including a periodic component to injection or pumping and then monitoring the resulting strain signal could be a way to monitor the subsurface.
Changes in fluid pressure deform porous media and this effect occurs in a variety of hydrogeologic processes, from the change in storage during pumping or injection to fluctuations in water levels caused by barometric pressure. We have developed instruments for measuring small strains in porous media, and we have used the resulting strain data to evaluate well testing, hydraulic fracturing, manual loading at the ground surface, and ambient hydrologic processes, like rainfall and evaporation. A particularly important application is the use of strain tensor data measured at shallow depths to analyze well tests or hydraulic fractures conducted at much greater depths. An early demonstration of this technique was conducted at the North Avant Field north of Tulsa, Oklahoma, where Pennsylvanian sandstone creates a confined aquifer and oil reservoir at a depth of 530m. We have showed that the strains caused by injecting into the aquifer could be measured at a depth of 30m and used to evaluate the properties of the aquifer. We recently expanded the array of strainmeters at the North Avant Field by deploying three more instruments at shallow depth (30m) along with a deep instrument at 520m depth in the winter, 2021. The deep instrument is deployed in shale caprock slightly above the aquifer. To our knowledge, the deep strainmeter at the North Avant Field is the deepest strainmeter ever deployed and this required refining methods originally developed for shallow deployments. The instrument was lowered to depth on oil field tubing and cemented in place using techniques and materials developed for use in oil wells. Optical fiber used to communicate with the instrument was cemented in the annulus on the outside of tubing. This is significant because the techniques we used could readily be extended to greater depth, suggesting that strainmeters can be deployed over a wide range of depths for monitoring critical subsurface processes. For example, it suggests that strainmeters could be deployed through the caprock to monitor for leaks from underlying CO2 storage reservoirs. The strainmeter array at the North Avant Field has been used to characterize deformation during a series of injection tests in the spring and summer, 2021. All the new strainmeters respond to pumping, and the strainmeters we installed earlier also responded. To our knowledge, this is the first application of well testing in a deep aquifer that was monitored by an array of strainmeters—our earlier work used strainmeters at a single location. We are currently analyzing the strain data using an analytical solution, a proxy-based Bayesian inversion algorithm, and other methods. Strainmeter data has also been used to characterize periodic pumping tests by us and Riley Blais. A periodically varying pumping rate causes both hydraulic head and strain signals that vary with the same period as the pumping. The peaks and troughs of the head in monitoring wells lag behind the peaks and troughs of the head in the pumping well, and this lag time increases with distance from the pumping well. The lag time of the pressure and the distance to the monitoring well can be used in a simple analysis to estimate the hydraulic diffusivity of the aquifer. The lag time determined from strain data can be used to estimate aquifer properties using the same analysis that works for the pressure only for strain data measured at particular locations. That is because the strain field in a confining unit advances upward, laterally and then downward even though the pressure in the underlying aquifer only advances laterally, according to our recent simulations. We have field data showing that a small periodic signal superimposed on an injection rate at the North Avant Field will create a periodic strain signal at shallow strainmeters. The field data and the recent simulations suggest that including a periodic component to injection or pumping and then monitoring the resulting strain signal could be a way to monitor the subsurface.
This report details the design, fabrication, and testing of surveillance test articles aimed at assessing material damage in reactor-relevant environments for effective degradation management. Two types of surveillance test articles with reduced sizes were developed based on design algorithms and finite element modeling: welded design and interlocking design. A furnace heating setup was adopted to apply multiple thermal cyclic loading profiles on the test articles with a temperature range of 500°C - 700°C, while the strain response was monitored using a digital image correlation technique. The testing results demonstrated the successful capturing of expected strain range for welded design while machining tolerance should be improved to engage strain coupling in the interlocking design. Mid-term (500 hours) and long-term (1500 hours) cyclic tests were conducted on welded test articles. A constant strain range of ~0.6% was observed at the specimen with testing under 500 hours, while a gradual decrease of strain at specimen was observed after 500 hours. Non-destructive evaluation through X-ray computed tomography confirmed the microcracks in the welds at specimen-driver joints after cyclic test that caused the strain change. Creep testing of the specimen after long-term cyclic test revealed a short creep life than expected. A multi-profile cyclic test was also conducted on a test article and demonstrated consistent strain response under different temperature ramp rates. The report also briefly discussed the challenges and future research efforts to advance test article development for material surveillance.
Material degradation in Advance Test Reactors (ATR) is governed by irradiation, corrosion, elevated temperature exposure and cyclic mechanical creep-fatigue loads. This degradation information during reactor operation condition is limited. Hence, material damage monitoring is a key aspect of the design, analysis and licensing of ATR components. The idea is to monitor material component operation conditions of component by using a surveillance test article. This test article is fabricated with bi-metal configuration with two different thermal expansion coefficients, and design is motivated by Simplified Model Test (SMT) specimen which can capture structure-like mechanical response. Upon raising temperature of the bi-metal test article configuration, expansion mismatch results tensile load on specimen. Thus, temperature dependent passively actuated loading is achieved. The idea is to place this surveillance test article in reactor at location ‘x’ to surveil the mechanical response at critical location ‘y’. By calibrating the test article design, material degradation at critical location can be surveilled through assessing the degradation in surveillance test article. This study presents test article development with different material combinations and follow-up experimental testing work through passively loading test article with temperature history. The test article geometry and observed test results are presented in presentation slides.
Structural walls in safety-related nuclear facilities are required to be designed for seismic and accident thermal (due to postulated high-energy pipe break events) loading combination. Current U.S. and international codes provide limited guidance for analysis and design of walls for this loading combination. This paper describes the experimental results and observations from tests conducted on a laboratory-scale (1:4 to 1:5) test unit representing steel-plate composite (SC) walls subjected to combined in-plane (seismic) and accident thermal loading. The test unit was subjected to surface temperatures of up to 450°F in combination with cyclic in-plane loading. Results of similar experiments recently conducted in Japan are also summarized (with surface temperatures up to 570°F). Surface heating combined with the low thermal conductivity and high specific heat of concrete resulted in nonlinear thermal gradients through the thickness of the specimens. These nonlinear thermal gradients and the associated self- or internal restraint led to extensive concrete cracking. This concrete cracking reduced the initial and secant stiffness of the specimens. The initial stiffness of the heated specimens reduced to 30 to 40% of the initial stiffness of the control (unheated) specimen. The secant stiffness of the heated specimens reduced up to 50% of the secant stiffness of the control (unheated) specimen. However, the in-plane shear strength of the heated SC specimens was still approximately 10 to 30% greater than the nominal in-plane shear strength calculated, for the limit state of steel plate von Mises yielding, using AISC N690 equations and measured material properties. Evaluation of the experimental results and observations suggests that the in-plane shear strength of SC walls subjected to typical accident surface temperatures (up to 570°F) can be estimated conservatively using the current provisions of AISC N690. The stiffness for accident thermal loading combinations can be considered to reduce from cracked composite stiffness at ambient temperature to fully cracked—that is, steel-only stiffness as the surface temperature increases up to typical accident value.
Four different shear test methods i.e. doubled notched shear test, asymmetrical four point bend test, Iosipescu test, and torsion test, were investigated for their ability to evaluate one standard SiC to SiC ceramic brittle joint while using small size specimens. Double notched shear test showed higher stress concentration at the notch base and a lower nominal shear strength. Both asymmetrical four point bend test and Iosipescu test utilized epoxy jointed metal extensors, which failed during test and caused misalignment and tensile type of failure. Torsion test can deliver true shear loading. However, base material failure was observed for the torsion joint samples in this study. None of the tests can successfully induce true shear failure of the joint because the joint is stronger and tougher than the SiC substrate. Torsion test appears to be promising because of the pure shear loading, less stress concentration, and easy alignment.
Objective Assess neck muscle activity for varying interactions between helmet, posture, and visual stress in a simulated “helo-hunch” posture. Background Military aviators frequently report neck pain (NP). Risk factors for NP include head-supported mass, awkward postures, and mental workload. Interactions between these factors could induce constant low-level muscle activation during helicopter flight and better explain instances of NP. Method Interactions between physical loading (helmet doffed/donned), posture (symmetric/asymmetric), and visual stress (low/high contrast) were studied through neck muscle electromyography (EMG), head kinematics, subjective discomfort, perceived workload, and task performance. Subjects ( n = 16) performed eight 30-min test conditions (varied physical loading, posture, and visual stress) while performing a simple task in a simulated “helo-hunch” seating environment. Results Conditions with a helmet donned had fewer EMG median frequency cycles (which infer motor unit rotation for rest/recovery, where more cycles are better) in the left cervical extensor and left sternocleidomastoid. Asymmetric posture (to the right) resulted in higher normalized EMG activity in the right cervical extensor and left sternocleidomastoid and resulted in less lateral bending compared with neutral across all conditions. Conditions with high visual stress also resulted in fewer EMG cycles in the right cervical extensor. Conclusion A complex interaction exists between the physical load of the helmet, postural stress from awkward postures, and visual stress within a simulated “helo-hunch” seating environment. Application These results provide insight into how visual factors influence biomechanical loading. Such insights may assist future studies in designing short-term administrative controls and long-term engineering controls.
We summarize recent progress in a program to develop externally powered dielectric-loaded accelerating (DLA) structures that can sustain high accelerating gradients. High-power RF tests of earlier structures showed strong multipactor loading. In addition, arcing at dielectric joints between the uniform DLA structure and matching sections at either end limited the achievable gradient. In this paper, we study the onset of multipactor in a DLA structure. We also study the effect of thin-film TiN coatings applied by atomic layer deposition and the effect of a reduction in the inner diameter of the structure. Test results of these structures show significant decreases in multipactor loading. We also test new structure designs that eliminate separate dielectric matching sections and, thus, the requirement for dielectric joints, including a DLA structure using a coaxial coupler and a clamped DLA structure. The clamped structure demonstrated a significantly improved gradient without breakdown.
Residential buildings with the ability to monitor and control their net-load (sum of load and generation) can provide valuable flexibility to power grid operators. We present a novel multiclass nonintrusive load monitoring (NILM) approach that enables effective net-load monitoring capabilities at high-frequency with minimal additional equipment and cost. The proposed machine learning based solution provides accurate multiclass state predictions while operating at a faster timescale (able to provide a prediction for each 60- Hz ac cycle used in US power grid) without relying on event-detection techniques. We also introduce an innovative hybrid classification-regression method that allows for the prediction of not only load on/off states but also individual load operating power levels. A test bed with eight residential appliances is used for validating the NILM approach. Results show that the overall method has high accuracy, good scaling and generalization properties.
Additive manufacturing is a versatile technique that shows promise in providing quick and dynamic manufacturing for complex engineering problems. Research has been ongoing into the use of additive manufacturing for potential applications in radiofrequency (RF) component technologies. Here, we present a method for developing an effective prototype load produced from 316L stainless steel on a direct metal laser sintering machine. The model was tested using simulation software to verify the validity of the design. The load structure was manufactured by an online digital manufacturing company, showing the viability of using easily accessible tools to manufacture RF structures. The produced load was able to produce an S11 value of −22.8 dB at a C-band frequency of 5.712 GHz while under a vacuum. In a high-power test, the load was able to terminate a peak power of 8.1 MW. The discussion includes future applications of the present method and how it will help to improve the implementation of future accelerator concepts.
Mini-split heat pumps are being proposed as a new retrofit option to replace resistance heating in the Pacific Northwest. NREL has previously developed a field test protocol for mini-split systems to ensure consistent results from field tests. This report focuses on the development of detailed system performance maps for mini-split heat pumps so that the potential benefits of mini-split systemscan be accurately analyzed for different climate regions and housing types. This report presents laboratory test results for two mini-split heat pumps. Steady-state heating and cooling performance for the Fujitsu 12RLS and Mitsubishi FE12NA was tested under a wide range of outdoor and indoor temperatures at various compressor and fan speeds. Cycling performance for each unit was also testedunder both modes of operation. Both systems performed quite well under low loads and the experimental test data aligned with manufacturer reported values. Adequate datasets were attained to promote performance modeling of these two systems in the future.
This report presents the test cases used to verify, validate and demonstrate the features and capabilities of the first release of the 3D Direct Simulation Monte Carlo (DSMC) code SPARTA (Stochastic Real Time Particle Analyzer). The test cases included in this report exercise the most critical capabilities of the code like the accurate representation of physical phenomena (molecular advection and collisions, energy conservation, etc.) and implementation of numerical methods (grid adaptation, load balancing, etc.). Several test cases of simple flow examples are shown to demonstrate that the code can reproduce phenomena predicted by analytical solutions and theory. A number of additional test cases are presented to illustrate the ability of SPARTA to model flow around complicated shapes. In these cases, the results are compared to other well-established codes or theoretical predictions. This compilation of test cases is not exhaustive, and it is anticipated that more cases will be added in the future.
This report presents the test cases used to verify, validate and demonstrate the features and capabilities of the first release of the 3D Direct Simulation Monte Carlo (DSMC) code SPARTA (Stochastic Real Time Particle Analyzer). The test cases included in this report exercise the most critical capabilities of the code like the accurate representation of physical phenomena (molecular advection and collisions, energy conservation, etc.) and implementation of numerical methods (grid adaptation, load balancing, etc.). Several test cases of simple flow examples are shown to demonstrate that the code can reproduce phenomena predicted by analytical solutions and theory. A number of additional test cases are presented to illustrate the ability of SPARTA to model flow around complicated shapes. In these cases, the results are compared to other well-established codes or theoretical predictions. This compilation of test cases is not exhaustive, and it is anticipated that more cases will be added in the future.
Open-water testing of marine renewable energy devices represents a significant milestone and hurdle for research teams and companies that seek to reduce the levelized cost of energy to allow these devices to compete in the open electrical generation market. For open-water testing of tidal energy converters (TECs), accurate measurements of loading characteristics on the blades and other structural components correlated with power performance metrics can be invaluable to further refine design principles and models, allowing continued improvement and cost reductions of new turbine designs. This paper will describe the modifications and additions made to a TEC system to achieve time-correlated blade strain measurements during full turbine operation along with a discussion on the overall impacts the required modifications had on the unmodified turbine.
In 2017, the United States Department of Energy (DOE) collaborated with Spanish and Korean organizations to perform a multimodal transportation test to measure shock and vibration loads imparted to used nuclear fuel (UNF) assemblies. This test used real fuel assembly components containing surrogate fuel mass to approximate the response characteristics of real, irradiated used nuclear fuel. Pacific Northwest National Laboratory was part of the test team and used the data collected during this test to validate numerical models needed to predict the response of real used nuclear fuel in other transportation configurations. This paper summarizes the modeling work and identifies lessons learned related to the modeling and analysis methodology. The modeling includes railcar dynamics using the NUCARS software code and explicit dynamic finite element modeling of used nuclear fuel cladding in LS-DYNA. The NUCARS models were validated against railcar dynamics data collected during captive track testing at the Federal Railroad Administration's Transportation Technology Center in Pueblo, CO. The LS-DYNA models of the fuel cladding were validated against strain gage data collected throughout the test campaign. One of the key results of this work was an assessment of fuel cladding fatigue, and the methods used to calculate fatigue are detailed in this paper. The validated models and analysis methodologies described in this paper will be applied to evaluate future UNF transportation systems.