Baroreflex Responses to Acute Changes in Blood Volume in Humans

To test the hypothesis that acute changes in plasma volume affect the stimulus-response relations of high- and low- pressure baroreflexes, eight men (27-44 yr old) underwent measurements for carotid-cardiac and cardiopulmonary baro- reflex responses under the following three volemic conditions: hypovolemic, normovolemic, and hypervolemic. The stimulus- response relation of the carotid-cardiac response curve was generated using a neck cuff device, which delivered pressure changes between +40 and -65 mmHg in continuous steps of 15 mmHg. The stimulus-response relationships of the cardiopulmonary baroreflex were studied by measurements of Forearm Vascular Resistance (FVR) and Peripheral Venotis Pressure (PVP) during low levels of lower body negative pressure (O to -20 mmHg). Altered vascular volume had no effect on response relations of the carotid-cardiac baroreflex but did alter the gain of the cardiopulmonary baroreflex (-7.93 q 1.71, -4.36 q 1.38, and -2.56 q 1.59 peripheral resistance units/mmHg for hypovolemic, normovolemic, and hypervolemic, respectively) independent of shifts in baseline FVR and PVP. These results indicate greater demand for vasoconstriction for equal reductions in venous pressure during progressive hypovolemia; this condition may compromise the capacity to provide adequate peripheral resistance during severe orthostatic stress. Fluid loading before reentry after spaceflight may act to restore vasoconstrictive capacity of the cardiopulnionary baroreflex but may not be an effective countermeasure against potential post- flight impairment of the carotid-cardiac baroreflex.

Thompson, Cynthia A.↗

Correlation Between Soil Moisture and Dust Emissions: An Investigation for Global Climate Modeling

This work is using the newly available NASA SMAP soil moisture measurement data to evaluate its impact on the atmospheric dust emissions. Dust is an important component of atmospheric aerosols, which affects both climate and air quality. In this work, we focused on semi-desert regions, where dust emissions show seasonal variations due to soil moisture changes, i.e. in Sahel of Africa. We first identified three Aerosol Robotic Network (AERONET) sites in the Sahel (IER_Cinzana, Banizoumbou, and Zinder_Airport). We then utilized measurements of aerosol optical depth (AOD), fine mode fraction, size distribution, and single-scattering albedo and its wave-length dependence to select dust plumes from the available measurements We matched the latitude and longitude of the AERONET station to the corresponding SMAP data cell in the years 2015 and 2016, and calculated their correlation coefficient. Additionally, we looked at the correlation coefficient with a three-day and a five-day shift to check the impact of soil moisture on dust plumes with some time delay. Due to the arid nature of Banizoumbou and Zinder_Airport, no correlation was found to exist between local soil moisture and dust aerosol load. While IER_Cinzana had soil moisture levels above the satellite threshold of 0.02cm3/cm3, R-value approaching zero indicated no presence of a correlation. On the other hand, Ilorin demonstrated a significant negative correlation between aerosol optical depth and soil moisture. When isolating the analysis to Ilorin's dry season, a negative correlation of -0.593 was the largest dust-isolated R-value recorded, suggesting that soil moisture is driven the dust emission in this semi-desert region during transitional season.

climate↗

Advanced Sensors & Controls FWP Overview

Fossil energy power generation is needed now and in the future, but its role is shifting from baseload operation to fulfilling dispatchable power needs in regions of the United States. Novel sensors and controls will help to increase efficiency, minimize emissions, and reduce operating costs of existing power generation technologies under this increased load following role; and help enable next generation power systems with high efficiency and greater operational flexibility.<br>

Buric, Michael↗

STOCHASTIC OPTIMAL POWER FLOW FOR REAL-TIME MANAGEMENT OF DISTRIBUTED RENEWABLE GENERATION AND DEMAND RESPONSE (Final Report)

To meet the grand challenge of a sustainable energy future, there has been a surge of interest in renewable energy. Today, the uncertainty associated with renewable resources is handled by using operating reserves. The high penetration of renewable resources, however, introduces difficult-to-control dynamics and challenges for power system operation. Decision support tools are necessary at the bulk system operational level to recognize and efficiently utilize renewable resources and distributed demand response products in concert with traditional grid resources. It is envisaged that responsive load can potentially have very significant cost advantages over either spinning or non-spinning ramping reserve. Critical decisions are made during hour(s)-ahead and real-time power system operation regarding the commitment and dispatch of generators to ensure power delivery is both reliable and economic. These decisions are typically made by a security constrained optimal flow, which determines future generator commitments, dispatches, and ensures adequate reserves are available in the event of a contingency (unexpected outage) or if future system conditions deviate from forecasts. However, security has been always based on a pre-specified subset of contingency constraints whose enforcement does not guarantee security under all possible future possibilities while also giving little or no weight to the likelihood of each contingent event or the severity of its consequences. Existing tools, which are based exclusively on deterministic optimization models, do not yield optimal operational decisions to address these new challenges, in terms of both reliability and cost-effectiveness. This project has focused on developing a stochastic optimal power flow (SOPF) framework, which integrates renewable resource uncertainty, load uncertainty, distributed storage (DS), demand response (DR) products, in a holistic manner to address the uncertainty associated with ever-increasing renewable resources, along with the inclusion of distributed demand response products in future power systems. A proof-of-concept problem was created using the Pennsylvania-Jersey-Maryland (PJM) power system network. Synthetic wind generation was added to the system to simulate 50% wind penetration. A 1-hour test of SOPF operation indicated more than 6% operational cost savings. The project continued by adding the Midwestern Independent System Operator (MISO) as a partner, with focus shifting from SOPF to Stochastic Look-Ahead Unit Commitment (SLAC). Unlike PJM, MISO is faced with significant renewable energy resources within its footprint and is challenged with substantial uncertainty in its operations. The SLAC distinguishes itself from existing tools that operators use. At best, today’s tools solve two to three cases independently, where one or two system parameters, such as forecasted load level (e.g., a low, base, and high forecast), are varied and the resulting scenarios are analyzed independently. The stochastic-based optimization of SLAC leverages statistical information from an ensemble of potential operational scenarios and their respective likelihood. The SLAC output can be translated into valuable information to the operator such as suggested commitments, optimal scheduling and dispatch of resources, reserve requirements at both locational and zonal resolutions, ramping availability and requirements, availability of demand response including operational guidance concerning the near-term and real-time coordination between distributed energy resources, and utilization of distributed storage resources. The developed SOPF/SLAC tool, a stand-alone tool compatible with existing EMSs, will provide system operators with unprecedented visibility, flexibility and predictability to these resources and operational guidance concerning the real-time coordination between DERs and DR/DS products. The game changing and practical impact of this disruptive technology will be dramatic and will usher in a new era in the electric power industry, wherein green energy concepts are fully embraced, and electric power costs are lowered throughout the nation.

42 ENGINEERING↗

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631↗

End region and current consolidation effects upon the performance of an MHD channel for the ETF conceptual design

It is noted that operating conditions which yielded a peak thermodynamic efficiency (41%) for an EFT-size MHD/steam power plant were previously (Wang et al., 1981; Staiger, 1981) identified by considering only the active region (the primary portion for power production) of an MHD channel. These previous efforts are extended here to include an investigation of the effects of the channel end regions on overall power generation. Considering these effects, the peak plant thermodynamic efficiency is found to be slightly lowered (40.7%); the channel operating point for peak efficiency is shifted to the supersonic mode (Mach number of approximately 1.1) rather than the previous subsonic operation (Mach number of approximately 0.9). Also discussed is the sensitivity of the channel performance to the B-field, diffuser recovery coefficient, channel load parameter, Mach number, and combustor pressure.

Wang, S. Y.↗

Ka-band MMIC beam steered transmitter array

A 32 GHz six element linear transmitter array which employs MMIC phase shifters and power amplifiers is developed and its performance is evaluated. The MMIC phase shifters contains 14 MESFETs in three digital switched line and one analog loaded line phase shifter, and the MMIC power amplifiers are two stage amplifiers using GaAs MESFETs with 0.25 micron gate lengths and gate widths of 0.1 mm and 0.3 mm. The design of the array is described. The phase shift measurements for the MMIC devices are analyzed. The data reveal that the switched line phase shifters are accurate to within 7 pct; the power amplifier 1 dB compressed output power varied over 0.3 dB; the beamwidth of the array is 7.5 deg; and beam steering is over + or - 8 deg.

Riley, A. L.↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensitivity Effects of High Temperature Overhead Conductors to Line Rating Variables

For traditional overhead transmission lines, the maximum allowable conductor operating temperature on ASCR, AAC, or AAAC lines for determining the static line ratings can be quite low, typically well under 100 C. At these low temperatures, the primary driver for determining static line ratings are assumptions made about the wind speed and direction and the ambient temperature. Assumptions for solar loading and emitted thermal radiation, driven by line emissivity and absorptivity, are secondary factors, and only provide small changes to the static ratings. However, when considering newer high temperature conductors such as ACSS, ACCR, ZTACIR, and ACCC® the maximum allowable conductor temperatures can be significantly higher, up to 250° C. This higher temperature shifts the importance of the emissivity assumptions of the overhead transmission line, due to the nature of the T4 dependence of the radiative heat loss compared to the T1 dependence of the convective heat loss, as well as shifting the dependency on local wind conditions. Typical assumptions in the United States for the emissivity/absorptivity of overhead transmission lines in determining the static ratings are to use a value of 0.5 for both parameters or set a value in the range of 0.7 to 0.9. Recent experimental tests at EPRI have shown that higher emissivity aging assumptions may not be valid in some regions of the US, and that actual values may be much lower (0.25-0.45) than older studies have predicted (0.8-0.9). Here, the assumptions of different US Regional Transmission Operators (RTOs) and different utilities within RTOs are examined for the static ratings for traditional lower operating temperatures up to 100° C as well as with the higher maximum temperature conductors associated with newer conductor designs at 250° C. The sensitivity of the static ratings is examined at both lower and higher temperature conductors with respect to overhead line emissivity and absorptivity, wind speed, wind direction, and solar loading, and ambient temperature. It is shown that the effects of the conductor absorptivity, solar flux and ambient temperature on the static rating are increased when the transmission line has a lower maximum conductor temperature. The effects of the conductor emissivity, wind direction and wind speed have increased effects on the static rating when the transmission line has a higher maximum conductor temperature. In addition, example weather data is used to calculate the conductor temperature with different line emissivity and absorptivity assumptions. This shows the effect of assumptions made for emissivity only has a minor impact for low temperature lines, but for high temperature transmission lines can cause a 150-200° C temperature swing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Crowded supported metal atoms on catalytically active supports may compromise intrinsic activity: A case study of dual-site Pt/α-MoC catalysts

Increasing the surface population of supported catalytic sites, assuming these sites are stable, is considered a straightforward approach to improving the overall catalytic performance. Here, we report an exception represented by the Pt/α-MoC catalysts featuring atomically dispersed Pt. The Pt/α-MoC catalysts display very high activity for the reverse water gas shift reaction with near 100% CO selectivity for CO 2 :H 2 ratios from 0.25 to 4 and from 250 to 400 °C. Despite the excellent performance, the intrinsic activity per Pt-centric catalytic center declines as the Pt loading increases from 0.1 to 1.0 wt%. With the dispersed Pt evolving from isolated atoms to fully exposed ensembles, the shrinking inter-Pt-atom space impedes CO 2 activation at the critical Pt-Mo interfaces, where the Pt shall temporarily take the -O intermediates. The Pt, even as atomically dispersed without noticeable sintering, is underutilized in such a crowded state. This caution for high-loading catalyst design is translational to other systems where the direct catalytic roles of the supports are crucial.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Incentivizing Distributed Energy Resource Participation in Grid Services

The bulk power system is experiencing a dramatic shift as renewable generation growth continues to accelerate. Large-scale renewables adoption will help societies transition to a low-carbon, low-cost, and environmentally friendly electrical power system. However, the transition from a paradigm of generation following load to one where load follows generation will require large-scale interconnection and coordinated operation of Distributed Energy Resources (DERs), supported by open communication protocols. In this future grid scenario, DER aggregations will provide critical grid services that enable high penetration levels of renewable generation. This position paper presents an Energy Service Interface (ESI) that defines scope for ensuring secure, trustworthy information exchange between grid service providers and DERs. The goal of the ESI is to encourage large-scale participation of DERs in order to provide grid services through dispatch of DER aggregations. This position paper also presents an open smart energy communications protocol that allows DERs to advertise their characteristics and participate in grid services, within constraints established by the ESI. The paper presents several monetization incentives that grid service providers could use to encourage large-scale DER participation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gyrator employing field effect transistors

A gyrator circuit of the conventional configuration of two amplifiers in a circular loop, one producing zero phase shift and the other producing 180 deg phase reversal is examined. All active elements are MOS field effect transistors. Each amplifier comprises a differential amplifier configuration with current limiting transistor, followed by an output transistor in cascode configuration, and two load transistors of opposite conductivity type from the other transistors. A voltage divider control circuit comprises a series string of transistors with a central voltage input to provide control, with locations on the amplifiers receiving reference voltages by connection to appropriate points on the divider. The circuit produces excellent response and is well suited for fabrication by integrated circuits.

Hochmair, E. S.↗

Investigation of a GaAlAs Mach-Zehnder electro-optic modulator

A GaAs modulator operating at 0.78 to 0.88 micron wavelength has the potential to be integrated with a GaAs/GaAlAs laser diode for an integrated fiber-optic transmitter. A travelling-wave Mach-Zehnder modulator using the electro-optic effect of GaAs and operating at a wavelength of 0.82 microns has been investigated for the first time. A four layer Strip-loaded ridge optical waveguide has been analyzed using the effective index method and single mode waveguides have been designed. The electro-optic effect of GaAs has also been analyzed and a modulator using the geometry producing the maximum phase shift has been designed. A coplanar transmission line structure is used in an effort to tap the potentially higher bandwidth of travelling-wave electrodes. The modulator bandwidth has been calculated at 11.95 GHz with a required drive power of 2.335 Watts for full intensity modulation. Finally, some preliminary experiments were performed to characterize a fabrication process for the modulator.

Materna, David M.↗

Testing of a Loop Heat Pipe with Two Evaporators and Two Condensers

Most existing Loop Heat Pipes (LHPs) consist of one single evaporator and one single condenser. LHPs with multiple evaporators will be very desirable for cooling multiple heat sources or a heat source with large thermal footprints. Extending the LHP technology to include multiple evaporators and multiple condensers faces some challenges, including the interaction between individual compensation chambers, operating temperature stability, and adaptability to rapid power and sink temperature transients. This paper describe extensive testing of an LHP with two evaporators and two condensers. Tests performed include start-up, power cycle, sink temperature cycle, reservoir temperature cycle, and capillary limit. Test results showed that the loop could operate successfully under various heat load and sink conditions. The loop operating temperature is a function of the total heat load, the heat load distribution between the two evaporators, and temperatures of the two condenser sinks. Under most conditions, only one reservoir contained two-phase fluid and the other reservoir was completely liquid filled. Moreover, control of the loop operating temperature could shift from one reservoir to the other as the test condition changed.

Ku, Jentung↗

Understanding the Shift of Drivers of Soil Erosion and Sedimentation Based on Regional Process-Based Modeling in the Mississippi River Basin During the Past Century

Soil erosion and sedimentation problems remain a major water quality concern for making watershed management policies in the Mississippi River Basin (MRB). It is unclear whether the observed decreasing trend of stream suspended sediment loading to the mouth of the MRB over the last eight decades truly reflects a decline in upland soil erosion in this large basin. Here, for this work, we improved a distributed regional land surface model, the Dynamic Land Ecosystem Model, to evaluate how climate and land use changes have impacted soil erosion and sediment yield over the entire MRB during the past century. Model results indicate that total sediment yield significantly increased during 1980–2018, despite no significant increase in annual precipitation and runoff. The increased soil erosion and sediment yield are mainly driven by intensified extreme precipitation (EP). Spatially, we found notable intensified EP events in the cropland-dominated Midwest region, resulting in a substantial increase in soil erosion and sediment yield. Land use change played a critical role in determining sediment yield from the 1910s to the 1930s, thereafter, climate variability increasingly became the dominant driver of soil erosion, which peaked in the 2010s. This study highlights the increasing influences of extreme climate in affecting soil erosion and sedimentation, thus, water quality. Therefore, existing forest and cropland Best Management Practices should be revisited to confront the impacts of climate change on water quality in the MRB.

54 ENVIRONMENTAL SCIENCES↗

Temperature/pressure and water vapor sounding with microwave spectroscopy

Two intense microwave spectra lines exist in the martian atmosphere that allow unique sounding capabilities: water vapor at 183 GHz and the (2-1) rotational line of CO at 230 GHz. Microwave spectra line sounding is a well-developed technique for the Earth's atmosphere for sounding from above from spacecraft and airplanes, and from below from fixed surface sites. Two simple instruments for temperature sounding on Mars (the CO line) and water vapor measurements are described. The surface sounder proposed for the MESUR sites is designed to study the boundary layer water vapor distribution and the temperature/pressure profiles with vertical resolution of 0.25 km up to 1 km with reduced resolution above approaching a scale height. The water channel will be sensitive to a few tenths of a micrometer of water and the temperature profile will be retrieved to an accuracy between 1 and 2 K. The latter is routinely done on the Earth using oxygen lines near 60 GHz. The measurements are done with a single-channel heterodyne receiver looking into a 10-cm mirror that is canned through a range of elevation angles plus a target load. The frequency of the receiver is sweep across the water and CO lines generating the two spectra at about 1-hr intervals throughout the mission. The mass and power for the proposed instrument are 2 kg and 5-8 W continuously. The measurements are completely immune to the atmospheric dust and ice particle loads. It was felt that these measurements are the ultimate ones to properly study the martian boundary layer from the surface to a few kilometers. Sounding from above requires an orbiting spacecraft with multichannel microwave spectrometers such as the instrument proposed for MO by a subset of the authors, a putative MESUR orbiter, and a proposed Discovery mission called MOES. Such an instrument can be built with less than 10 kg and use less than 15 W. The obvious advantage of this approach is that the entire atmosphere can be sounded for temperature and water vapor in a few hours with somewhat better than a scale height resolution. If a bigger mirror is used (greater than 30 cm) limb sounding geometry can be employed and half scale height resolution achieved to altitudes up to at least 60 km. Again, the measurements are immune to dust and ice loads. Water vapor sensitivity of 0.1 micrometer can be achieved (even with a nadir instrument) and temperature profiles retrieved to an accuracy of better than 2 K from the surface to about 60 km. Winds can be measured from the doppler shifts of CO lines in the limb sounding mode.

Muhleman, D. O.↗

High Resolution Doppler Lidar

This Grant supported the development of an incoherent lidar system to measure winds and aerosols in the lower atmosphere. During this period the following activities occurred: (1) an active feedback system was developed to improve the laser frequency stability; (2) a detailed forward model of the instrument was developed to take into account many subtle effects, such as detector non-linearity; (3) a non-linear least squares inversion method was developed to recover the Doppler shift and aerosol backscatter without requiring assumptions about the molecular component of the signal; (4) a study was done of the effects of systematic errors due to multiple etalon misalignment. It was discovered that even for small offsets and high aerosol loadings, the wind determination can be biased by as much as 1 m/s. The forward model and inversion process were modified to account for this effect; and (5) the lidar measurements were validated using rawinsonde balloon measurements. The measurements were found to be in agreement within 1-2 m/s.

Source record↗