Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid chromatography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Carbonaceous Meteorites Contain a Wide Range of Extraterrestrial Nucleobases

All terrestrial organisms depend on nucleic acids (RNA and DNA), which use pyrimidine and purine nucleobases to encode genetic information. Carbon-rich meteorites may have been important sources of organic compounds required for the emergence of life on the early Earth; however, the origin and formation of nuc1eobases in meteorites has been debated for over 50 y. So far, the few nuc1eobases reported in meteorites are biologically common and lacked the structural diversity typical of other indigenous meteoritic organics. Here, we investigated the abundance and distribution of nucleobases and nucleobase analogs in formic acid extracts of 12 different meteorites by liquid chromatography-mass spectrometry. The Murchison and Lonewolf Nunataks 94102 meteorites contained a diverse suite of nucleobases, which included three unusual and terrestrially rare nucleobase analogs; purine, 2,6-diminopurine, and 6,8-diaminopurine. In a parallel experiment, we found an identical suite of nucleobases and nucleobase analogs generated in reactions of ammonium cyanide. Additionally, these nucleobase analoge were not detected above our parts-per-billion detection limits in any of the procedural blanks, control samples, a terrestrial soil sample, and an Antarctic ice sample. Our results demonstrate that the purines detected in meteorites are consistent with products of ammonium cyanide chemistry, which provides a plausible mechanism for their synthesis in the asteroid parent bodies, and strongly supports an extraterrestrial origin. The discovery of new nucleobase analogs in meteorites also expands the prebiotic molecular inventory available for constructing the first genetic molecules.

Callahan, Michael P.↗

Spontaneous Oligomerization of Nucleotide Alternatives in Aqueous Solutions

On early Earth, a primitive polymer that could spontaneously form from likely available precursors may have preceded both RNA and DNA as the first genetic material. Here, we report that heated aqueous solutions containing 5-hydroxymethyluracil (HMU) result in oligomers of uracil, heated solutions containing 5-hydroxymethylcytosine (HMC) result in oligomers of cytosine, and heated solutions containing both HMU and HMC result in mixed oligomers of uracil and cytosine. Oligomerization of hydroxymethylated pyrimidines, which may have been abundant on the primitive Earth, might have been important in the development of simple informational polymers.

Liquid chromatography↗

Elucidating the Gravome: Quantitative Proteomic Profiling of the Response to Chronic Hypergravity in Drosophila

Altered gravity conditions, such as experienced by organisms during spaceflight, is known to cause transcriptomic and proteomic changes. We describe the proteomic changes in the whole body of adult Drosophila melanogaster (fruit fly), but focus specifically on the localized changes in the adult head in response to chronic hypergravity (3G) treatment. Canton S adult female flies (2-3 days old) were exposed to chronic hypergravity for 9 days and compared with parallel 1G controls. After hypergravity treatment, whole flies and fly heads were separated, and evaluated for quantitative comparison of the two gravity conditions using an isobaric tagging liquid chromatography-tandem mass spectrometry approach. Data revealed a total of 1948 (whole flies) and 1480 (head) proteins to be differentially present in hypergravity-treated flies. Gene Ontology analysis of head specific proteomics revealed host immune response and humoral stress proteins were significantly upregulated. Proteins related to calcium signaling, ion transport and ATPase were decreased. Enhanced expression of cuticular proteins may suggest an alteration in chitin metabolism and in chitin-based cuticle development. We therefore present a comprehensive quantitative survey of proteomic changes in response to chronic hypergravity in Drosophila, which will help elucidate the underlying molecular mechanisms associated with altered gravity environments.

Hypergravity↗

Impact of Growth Phase, Pigment Adaptation, and Climate Change Conditions on the Cellular Pigment and Carbon Content of Fifty‐One Phytoplankton Isolates

Owing to their importance in aquatic ecosystems, the demand for models that estimate phytoplankton biomass and community composition in the global ocean has increased over the last decade. Moreover, the impacts of climate change, including elevated carbon dioxide (CO2), increased stratification, and warmer sea surface temperatures, will likely shape phytoplankton community composition in the global ocean. Chemotaxonomic methods are useful for modeling phytoplankton community composition from marker pigments normalized to chlorophyll a (Chl a). However, photosynthetic pigments, particularly Chl a, are sensitive to nutrient and light conditions. Cellular carbon is less sensitive, so using carbon biomass instead may provide an alternative approach. To this end, cellular pigment and carbon concentrations were measured in 51 strains of globally relevant, cultured phytoplankton. Pigment-to-Chl a and pigment-to-carbon ratios were computed for each strain. For 25 strains, measurements were taken during two growth phases. While some differences between growth phases were observed, they did not exceed within class differences. Multiple strains of Amphidinium carterae, Ditylum brightwellii and Heterosigma akashiwo were measured to determine whether time in culture influenced pigment and carbon composition. No appreciable trends in cellular pigment or carbon content were observed. Lastly, the potential impact of climate change conditions on the pigment ratios was assessed using a multistressor experiment that included increased mean light, temperature, and elevated pCO2 on three species: Thalassiosira oceanica, Ostreococcus lucimarinus, and Synechococcus. The largest differences were observed in the pigment-to-carbon ratios, while the marker pigments largely covaried with Chl a. The implications of these observations to chemotaxonomic applications are discussed.

Pigments↗

Experimental Studies on the Effect of Impact Processes on the Formation and Evolution of Amino Acids

Introduction: A critical step in the emergence of life on Earth was the synthesis of larger organic molecules from simple building blocks such as NH3, CO2, H2O, and CH3OH. The presence of amino acids and other complex organics in comets and meteorites demonstrates that widespread organic synthesis likely occurred across the early solar system. Building on previous work [e.g., 1-3], we systematically explore impact-driven chemical evolution of exogenous organics and their precursors. Collisional processes may also have provided a source of energy for the formation of more complex organics from endogenous building blocks. The high flux of impactors to Earth immediately prior to and during the origins of life suggests that impacts could have played a critical role. Key Questions: 1. How are the formation and evolution of amino acids affected by the presence of a mineral matrix during cometary and asteroidal impacts onto the early Earth? 2. Do some minerals (e.g., phyllosilicates) provide a more robust protective framework or reactive surface site for amino-acid formation and/or polymerization? 3. Does the abundance of ices and/or amino acids relative to that of the mineral matrix affect the formation and evolution of amino acids? 4. Are there impact velocities/shock pressures at which formation or polymerization of amino acids is favored or precluded? Experimental Approach: This study systematically examines the conditions under which amino acids and other organic molecules can form, be polymerized, and/or be destroyed during impact events into particulate regolith simulants. Variable parameters include the modal composition of this regolith (silicate matrices, ratios of ices, silicates, and amino acids) and impact velocities/shock pressures. Impacts experiments were performed using the two-stage light-gas gun (LGG), vertical gun (VG), and flat-plate accelerator (FPA) in the Experimental Impact Lab at JSC. FPA experiments were performed over a range of shock pressures (11.3-31.5 GPa) using CM chondrite simulant mixed with amino acids at ratios of 0:10, 1:10, 1:103, and 1:106 (amino acid:host). Techniques for mixing cometary ices have been optimized and test runs have been performed using the LGG (see figure below). Analysis: Post-impact, samples are heated in water to extract amino acids and peptides. Extracts are characterized via liquid chromatography-mass spectrometry (LC-MS) and the mineralogies of solid residues are characterized using X-ray diffraction, scanning electron microscopy and transmission electron microscopy. Additional LC-MS and mineralogical analyses are underway.

Eve L Berger↗

Low-Cost Sensor Performance Intercomparison, Correction Factor Development, and 2+ Years of Ambient PM2.5 Monitoring in Accra, Ghana

Particulate matter air pollution is a leading cause of global mortality, particularly in Asia and Africa. Addressing the high and wide-ranging air pollution levels requires ambient monitoring, but many low- and middle-income countries (LMICs) remain scarcely monitored. To address these data gaps, recent studies have utilized low-cost sensors. These sensors have varied performance, and little literature exists about sensor intercomparison in Africa. By colocating 2 QuantAQ Modulair-PM, 2 PurpleAir PA-II SD, and 16 Clarity Node-S Generation II monitors with a reference-grade Teledyne monitor in Accra, Ghana, we present the first intercomparisons of different brands of low-cost sensors in Africa, demonstrating that each type of low-cost sensor PM2.5 is strongly correlated with reference PM2.5, but biased high for ambient mixture of sources found in Accra. When compared to a reference monitor, the QuantAQ Modulair-PM has the lowest mean absolute error at 3.04 μg/m3, followed by PurpleAir PA-II (4.54 μg/m3) and Clarity Node-S (13.68 μg/m3). We also compare the usage of 4 statistical or machine learning models (Multiple Linear Regression, Random Forest, Gaussian Mixture Regression, and XGBoost) to correct low-cost sensors data, and find that XGBoost performs the best in testing (R2: 0.97, 0.94, 0.96; mean absolute error: 0.56, 0.80, and 0.68 μg/m3 for PurpleAir PA-II, Clarity Node-S, and Modulair-PM, respectively), but tree-based models do not perform well when correcting data outside the range of the colocation training. Therefore, we used Gaussian Mixture Regression to correct data from the network of 17 Clarity Node-S monitors deployed around Accra, Ghana, from 2018 to 2021. We find that the network daily average PM2.5 concentration in Accra is 23.4 μg/m3, which is 1.6 times the World Health Organization Daily PM2.5 guideline of 15 μg/m3. While this level is lower than those seen in some larger African cities (such as Kinshasa, Democratic Republic of the Congo), mitigation strategies should be developed soon to prevent further impairment to air quality as Accra, and Ghana as a whole, rapidly grow.

Humidity↗

Separation of thorium from uranium ore

Thorium-230 has many research applications, but there is not a commercial source of this isotope. However, since 230 Th is part of the 238 U decay chain, it can be separated from naturally occurring uranium. In this work, a novel procedure was developed to separate thorium from uranium ore, consisting of leaching, liquid–liquid extraction, precipitations and ion exchange chromatography. Here, the final product was 91.32 ± 0.77 mg of thorium with a purity of 99.5 ± 1.2 wt%. Of that, 7.65 ± 0.10 mg was 230 Th and the remainder 232 Th. The total yield of 230 Th was 71.1 ± 5.4%. Ways to improve the yield by further processing the back-extraction solution are suggested.

230Th↗

Coupling Online Conductivity with Offline Ion Chromatography Measurements using the Particle-into-Liquid Sampler

A particle-into-liquid sampler has been combined with a flow through conductivity cell to provide a continuous, non-destructive, online measurement in support of offline ion chromatography analysis. The conductivity measurement provides a rapid assessment of the total ion concentration augmenting the slower batch data from the offline analysis and is developed primarily to assist airborne measurements, where fast time response is essential. A model of the conductivity was developed for measured ions and excellent closure is derived for laboratory-generated aerosols. The PILS-conductivity measurement was extensively tested during the NASA Cloud, Aerosol and Monsoon Processes: Philippines Experiment (CAMP2Ex) across nineteen research flights and the conductivity data was found to augment the temporal capability of the PILS instrument for assessing ionic species, allowing sub-minute variability to be resolved. Through the sampling of a diverse range of ambient aerosol, including biomass burning, fresh and aged urban pollution, the conductivity measurement offered additional useful information to untangle the composition of complex aerosol mixtures, specifically for assessing acidic aerosol conditions.

Ewan Colin Crosbie↗

Multiscale investigations of europium(III) complexation with tetra- n -octyl diglycolamide confined in porous solid supports

The microscopic, short-range coordination environments and mesoscopic, long-range structures of Eu 3+ contacted with tetra-n-octyl diglycolamide (TODGA) confined on ordered mesoporous carbon (OMC) nanoparticles and Amberchrom CG 71 resin were probed using Eu L 3 -edge extended X ray absorption fine structure (EXAFS) as well as small-angle and wide-angle X ray scattering, SAXS and WAXS, respectively. A homoleptic Eu(TODGA) 3 3+ coordination complex typical of liquid-liquid extraction (LLE) chemistry is present under low Eu 3+ loading conditions on both solid supports. Deviations from this traditional structure motif appear at hyperstoichiometric Eu 3+ loadings, above the 1:3 Eu 3+ to TODGA mole ratio. Microcrystalline-like domains with multinuclear Eu speciation are templated by use of these high Eu 3+ loading conditions with the functionalized OMC materials, highlighting a major departure of liquid-solid extraction chromatography (EXC) from the coordination chemistry of LLE. No such long-range spatial coherence was observed for analogous polyacrylic resin materials. Furthermore, these results demonstrate both the similarities and differences between multiscale structures in LLE and EXC, underscoring the opportunities for improved separation techniques based on solid supports with long-range spatial coherence (e.g., OMC systems) and without it (e.g., resin materials). Since crystallization was the first approach to adjacent lanthanide separations, the prospect of templating microcrystalline TODGA-lanthanide complexes that are otherwise not prone to crystallization by use of OMC nanoparticles represents a new entry to addressing long-standing issues in purification by liquid-solid phase separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nucleobases and other Prebiotic Species from the Ultraviolet Irradiation of Pyrimidine in Astrophysical Ices

Nucleobases are N-heterocycles that are the informational subunits of DNA and RNA, and are divided into two families: pyrimidine bases (uracil, cytosine, and thymine) and purine bases (adenine and guanine). Nucleobases have been detected in meteorites and their extraterrestrial origin confirmed by isotope measurement. Although no Nheterocycles have ever been observed in the ISM, the positions of the 6.2-m interstellar emission features suggest a population of such molecules is likely to be present. In this work we study the formation of pyrimidine-based molecules, including nucleobases, as well as other species of prebiotic interest, from the ultraviolet (UV) irradiation of pyrimidine in combinations of H2O, NH3, CH3OH, and CH4 ices at low temperature, in order to simulate the astrophysical conditions under which prebiotic species may be formed in the interstellar medium and icy bodies of the Solar System. Experimental: Gas mixtures are prepared in a glass mixing line (background pressure approx. 10(exp -6)-10(exp -5) mbar). Relative proportions between mixture components are determined by their partial pressures. Gas mixtures are then deposited on an aluminum foil attached to a cold finger (15-20 K) and simultaneously irradiated with an H2 lamp emitting UV photons (Lyman and a continuum at approx.160 nm). After irradiation samples are warmed to room temperature, at which time the remaining residues are recovered to be analyzed with liquid and gas chromatographies. Results: These experiments showed that the UV irradiation of pyrimidine mixed in these ices at low temperature leads to the formation of several photoproducts derived from pyrimidine, including the nucleobases uracil and cytosine, as well as their precursors 4(3H)-pyrimidone and 4-aminopyrimidine (Fig. 1). Theoretical quantum calculations on the formation of 4(3H)-pyrimidone and uracil from the irradiation of pyrimidine in pure H2O ices are in agreement with their experimental formation pathways. In those residues, other species of prebiotic interest such as urea and the amino acids glycine and alanine could also be identified. However, no pyrimidine derivatives containing CH3 groups, including the third nucleobase thymine, could be identified, suggesting that the addition of methyl groups to pyrimidine is not an efficient process.

DNA and RNA↗

Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen

Single-cell mass spectrometry (MS) is advancing our understanding of metabolic pathways in heterogeneous cell populations; however, many techniques are slow or require disruptive sample preparations. This study evaluated coupling a modified HP D100 single-cell inkjet dispenser with liquid vortex capture-mass spectrometry (D100/LVC-MS). The D100 is a single-cell inkjet dispenser capable of titrating solutions and isolating single cells via disposable cassettes equipped with microfluidic channels and an impedance sensor. The LVC-MS enables high-throughput capture, lysis, and ionization of analytes for mass spectrometric analysis. The D100/LVC-MS system was characterized through titration and single-cell experiments. Propranolol titration demonstrated linearity across a broad concentration range using the D100/LVC-MS system. Additionally, Hep G2 hepatocarcinoma cells and Chlamydomonas reinhardtii algae were used to showcase the D100’s high-throughput or low-buffer-volume single-cell dispensing strategies. The D100/LVC-MS system’s performance was validated by evaluating tamoxifen-induced steatosis in Hep G2 cells. Tamoxifen, associated with nonalcoholic fatty liver disease in breast cancer patients following long-term use, was tested in Hep G2 cells at 20 µM for 72 h against DMSO-treated controls. High-throughput analysis of 500 cells per condition, completed in 25 min per run, demonstrated the system’s efficiency. The D100/LVC-MS system simultaneously quantified tamoxifen and measured triglycerides and phosphatidylcholines. Triglycerides were upregulated in the tamoxifen-treated cells and the results indicated two distinct cell populations, differing in tamoxifen and phosphatidylcholines levels, suggesting heterogeneity within the treated population. In conclusion, these findings highlight the D100/LVC-MS system as a cost-effective, high-throughput platform for single-cell metabolomics and lipidomics, with significant potential for evaluating metabolic alterations.

Chromatography↗

Temperature-dependent changes in gas chromatographic separation metrics for trihexyl(tetradecyl)phosphonium-based ionic liquid stationary phases and comparison to conventional polysiloxane stationary phases

Here, to assess whether the trihexyl(tetradecyl)phosphonium chloride ([P 66614 + ][Cl - ]) ionic liquid (IL), employed as a gas chromatographic stationary phase, exhibits temperature-dependent phase transitions or structural heterogeneity, retention thermodynamics for probe molecules of varied chemical structure were investigated by gas chromatography (GC) over the temperature range of 25 to 64 °C using van’t Hoff analysis. All van’t Hoff plots for n-alkanes (C8–C12) and other probe analytes were linear, indicating the absence of detectable phase-transition behavior. The [P 66614 + ][Cl - ] IL was further compared with the [P 66614 + ] bis[(trifluoromethyl)sulfonyl]imide ([P 66614 + ][NTf 2 - ]) IL and commercial polysiloxane stationary phases in terms of temperature-dependent resolution behavior and chromatographic selectivity over the temperature range of 28–52 °C. The resolution factors of analytes in mixtures obtained using gas chromatography–mass spectrometry (GC–MS) and the summation of resolution values decreased smoothly with temperature on both IL stationary phases and on the dimethylphenylcyano-substituted polymeric stationary phase (OV-1701), whereas the poly(50% diphenyl/50% dimethyl siloxane) stationary phase (SPB-50) exhibited irregularities in its temperature-dependent summation of resolution profile, showing a distinct maximum in the temperature range of 34–40 °C. Selectivity values for the IL stationary phases were largely determined by the anion, with the [P 66614 + ][Cl - ] IL providing enhanced separation between polar and aromatic analytes, while the [P 66614 + ][NTf 2 - ] IL favored dispersive and π-π interactions that resulted in a reversal of elution order for some aliphatic–aromatic and alkyne-containing analyte pairs. Capillary columns prepared using different surface activation methods and coated with identical [P 66614 + ][Cl - ] IL stationary phase showed indistinguishable temperature-dependent trends in summation of resolution value and selectivity. An evaluation of analyte-specific selectivity provides insight into the characteristic separation behavior of the stationary phases and enables identification of analyte classes that are more efficiently separated on the [P 66614 + ]-based IL stationary phases compared to conventional stationary phase materials.

Chromatographic selectivity↗

Crosslinked polymeric ionic liquid stationary phases incorporating a combination of silver(I) and copper(II) ions for olefin separations by gas chromatography

The development of efficient and selective olefin separation technologies is a critical challenge within the chemical industry given the high energy demands of conventional cryogenic distillation methods. To address this, the study explores the effectiveness of polymeric ionic liquid (PIL) stationary phases in gas chromatography (GC) that incorporate both silver(I) ([Ag + ]) and copper(II) ([Cu 2+ ]) ions for enhanced olefin separation via π-complexation interactions. Further, the effects of both non-crosslinked and crosslinked PIL stationary phases containing varying ratios of [Ag⁺] and [Cu²⁺] ions were systematically investigated to evaluate their impact on the separation of olefins from paraffins and structurally similar olefins. Retention measurements using a broad range of olefinic probes revealed that [Ag⁺] ions provided stronger and more consistent π-complexation in PIL-based stationary phases, while [Cu²⁺] ions preferentially enhance olefin retention in crosslinked systems. Furthermore, thermal stability studies showed that [Ag + ]-containing PIL stationary phases maintain stable olefin separation efficiency over prolonged exposure under elevated temperatures, while crosslinked PIL stationary phases containing [Cu 2+ ] ions exhibited stronger retention due to increased surface adsorption. These findings provide insight into the tunability of metal–olefin interactions using PIL-based stationary phases and suggest design strategies for achieving thermally stable and highly selective chromatographic separations of unsaturated hydrocarbons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polymeric ionic liquids containing copper(I) and copper(II) ions as gas chromatographic stationary phases for olefin separations

Copper(I) ions (Cu + ) are used in olefin separations due to their olefin complexing ability and low cost, but their instability in the presence of water and gases limits their widespread use. Ionic liquids (ILs) have emerged as stabilizers of Cu + ions and prevent their degradation, providing high olefin separation efficiency. There is limited understanding into the role that polymeric ionic liquids (PILs), which possess similar structural characteristics to ILs, have on Cu + ion-olefin interactions. Moreover, copper ions with diverse oxidation states, including Cu + and Cu 2+ ions, have been rarely employed for olefin separations. In this study, gas chromatography (GC) is used to investigate the interaction strength of olefins to stationary phases composed of the 1-hexyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide ([C 6 MIM + ][NTf 2 – ]) IL and the poly(1-hexyl-3-vinylimidazolium [NTf 2 – ]) (poly([C 6 VIM + ][NTf 2 – ])) PIL containing monovalent and divalent copper salts (i.e., [Cu + ][NTf 2 – ] and [Cu 2+ ]2[NTf 2 – ]). The chromatographic retention of alkenes, alkynes, dienes, and aromatic compounds was examined. Incorporation of the [Cu 2+ ]2[NTf 2 – ] salt into a stationary phase comprised of poly(dimethylsiloxane) resulted in strong retention of olefins, while its addition to the [C 6 MIM + ][NTf 2 – ] IL and poly([C 6 VIM + ][NTf 2 – ]) PIL allowed for the interaction strength to be modulated. Olefins exhibited greater affinities toward IL and PIL stationary phases containing the [Cu 2+ ]2[NTf 2 – ] salt compared to those with the [Cu + ][NTf 2 – ] salt. Elimination of water from both copper salts was observed to be an important factor in promoting olefin interactions, as evidenced by increased olefin retention upon exposure of the stationary phases to high temperatures. Furthermore, to evaluate the long-term thermal stability of the stationary phase, chromatographic retention of probes was measured on the [Cu 2+ ]2[NTf 2 – ]/[C 6 MIM + ][NTf 2 – ] IL stationary phase after its exposure to helium at a temperature of 110°C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distribution of iodine into blood components of the Sprague-Dawley rat differs with the chemical form administered

It has been reported previously that radioactivity derived from iodine distributes differently in the Sprague-Dawley rat depending on the chemical form administered (Thrall and Bull, 1990). In the present communication we report the differential distribution of radioactivity derived from iodine (I2) and iodide (I-) into blood components. Twice as much radioiodine is in the form of I- in the plasma of animals treated with 125I- compared to 125I2-treated rats. No I2 could be detected in the plasma. With an increase in dose, increasing amounts of radioactivity derived from 125I2-treated animals distribute to whole blood compared to equivalent doses of 125I-, reaching a maxima at a dose of 15.8 mumol I/kg body weight. Most of the radioactivity derived from I2 associates with serum proteins and lipids, in particular with albumin and cholesteryl iodide. These data indicate a differential distribution of radioactivity depending on whether it is administered as iodide or iodine. This is inconsistent with the commonly held view that iodine (I2) is reduced to iodide (I-) before it is absorbed systemically from the gastrointestinal tract.

Non-NASA Center↗

Direct Observation of Liquid Crystal Droplet Configurational Transitions using Optical Tweezers

Liquid crystals (LCs) are easily influenced by external interactions, particularly at interfaces. When rod-like LC molecules are confined to spherical droplets, they experience a competition between interfacial tension and elastic deformations. The configuration of LCs inside a droplet can be controlled using surfactants that influence the interfacial orientation of the LC molecules in the oil-phase of an oil in water emulsion. Here, we used the surfactant sodium dodecyl sulfate (SDS) to manipulate the orientation of 5CB molecules in a polydisperse emulsion and examined the configuration of the droplets as a function of SDS concentration. We triggered pronounced morphological transitions by altering the SDS concentration while observing an individual LC droplet held in place using an optical tweezer. We compared the experimental configuration changes to predictions from simulations. Finally, we observed a hysteresis in the SDS concentration that induced the morphological transition from radial to bipolar and back as well as a fluctuations in the configuration during the transition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep eutectic solvents as green and sustainable diluents in headspace gas chromatography for the determination of trace level genotoxic impurities in pharmaceuticals

Genotoxic impurities (GTIs) are potential carcinogens that need to be controlled down to ppm or lower concentration levels in pharmaceuticals under strict regulations. The static headspace gas chromatography (HS-GC) coupled with electron capture detection (ECD) is an effective approach to monitor halogenated and nitroaromatic genotoxins. Deep eutectic solvents (DESs) possess tunable physico-chemical properties and low vapor pressure for HS-GC methods. In this study, zwitterionic and non-ionic DESs have been used for the first time to develop and validate a sensitive analytical method for the analysis of 24 genotoxins at sub-ppm concentrations. Compared to non-ionic diluents, zwitterionic DESs produced exceptional analytical performance and the betaine: 7 (1,4- butane diol) DES outperformed the betaine: 5 (1,4-butane diol) DES. Limits of detection (LOD) down to the 5-ppb concentration level were achieved in DESs. Wide linear ranges spanning over 5 orders of magnitude (0.005–100 µg g –1 ) were obtained for most analytes with exceptional sensitivities and high precision. The method accuracy and precision were validated using 3 commercially available drug substances and excellent recoveries were obtained. Finally, this study broadens the applicability of HS-GC in the determination of less volatile GTIs by establishing DESs as viable diluent substitutes for organic solvents in routine pharmaceutical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗