Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lasers sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Development of mid-infrared solid state lasers for spaceborne lidar

Researchers investigated laser performance of Ho(3+):Tm(3+):Cr(3+):YAG crystals under both Cr:GSAG laser and flashlamp pumping. A flashlamp pumped Cr:GSAG laser was built to simulate high power quasi-CW laser diode pumping of a 2.1 micron holmium laser. The 2.1 micron output laser energy exceeded more than 14 mJ, the highest value reported to date under laser pumping near 785 nm. This was obtained in a pulse length of nearly 650 microns from a 3 x 3 mm Ho:Tm:Cr:YAG rod by using the flashlamp-pumped Cr:GSAG laser as a pumping source at the diode laser wavelength, 785 microns. In addition, Ho:Tm:Cr:YAG crystals with various Tm(3+) concentrations have been evaluated for flashlamp-pumped normal mode and Q-switched 2.1 micron laser operations under a wide variety of experimental conditions in order to understand internal dynamic processes among the ions and to determine an optimum lasing condition. An increase of the laser slope efficiency was observed with the increase of the Tm(3+) concentration from 2.5 atomic percent to 4.5 atomic percent. The thermal dependence of the laser performance was also investigated. Q-switched laser output energies corresponding to nearly 100 percent of the normal-mode laser energies were obtained in a strong single spike of 200 ns pulse length by optimizing the opening time of a lithium niobate Q-switch.

Whitney, Donald A.↗

Electro-optical Position-Measuring System

Electro-optical system developed to measure five components of coordinates representing position and orientation of model in test section of wind tunnel. Located entirely outside test section, uses small lasers as sources of light and self-scanning linear photodiode arrays (LPDA's) as sensing elements. With improvements in measuring ranges, adapted for use in other aerodynamic applications.

Tcheng, Ping↗

Self-Collimating Unstable-Resonator Diode Lasers

Proposed unstable-resonator diode lasers produce solid, collimated output beams without external collimating optics. Simpler to construct, used as pumps for optical-fiber amplifiers in telecommunications, for other solid-state lasers, and sources of light for free-space communications.

Lang, Robert J.↗

Advanced helium magnetometer for space applications

The goal of this effort was demonstration of the concepts for an advanced helium magnetometer which meets the demands of future NASA earth orbiting, interplanetary, solar, and interstellar missions. The technical effort focused on optical pumping of helium with tunable solid state lasers. We were able to demonstrate the concept of a laser pumped helium magnetometer with improved accuracy, low power, and sensitivity of the order of 1 pT. A number of technical approaches were investigated for building a solid state laser tunable to the helium absorption line at 1083 nm. The laser selected was an Nd-doped LNA crystal pumped by a diode laser. Two laboratory versions of the lanthanum neodymium hexa-aluminate (LNA) laser were fabricated and used to conduct optical pumping experiments in helium and demonstrate laser pumped magnetometer concepts for both the low field vector mode and the scalar mode of operation. A digital resonance spectrometer was designed and built in order to evaluate the helium resonance signals and observe scalar magnetometer operation. The results indicate that the laser pumped sensor in the VHM mode is 45 times more sensitive than a lamp pumped sensor for identical system noise levels. A study was made of typical laser pumped resonance signals in the conventional magnetic resonance mode. The laser pumped sensor was operated as a scalar magnetometer, and it is concluded that magnetometers with 1 pT sensitivity can be achieved with the use of laser pumping and stable laser pump sources.

Slocum, Robert E.↗

Characteristics of products generated by selective sintering and stereolithography rapid prototyping processes

The trend in the modern global economy towards free market policies has motivated companies to use rapid prototyping technologies to not only reduce product development cycle time but also to maintain their competitive edge. A rapid prototyping technology is one which combines computer aided design with computer controlled tracking of focussed high energy source (eg. lasers, heat) on modern ceramic powders, metallic powders, plastics or photosensitive liquid resins in order to produce prototypes or models. At present, except for the process of shape melting, most rapid prototyping processes generate products that are only dimensionally similar to those of the desired end product. There is an urgent need, therefore, to enhance the understanding of the characteristics of these processes in order to realize their potential for production. Currently, the commercial market is dominated by four rapid prototyping processes, namely selective laser sintering, stereolithography, fused deposition modelling and laminated object manufacturing. This phase of the research has focussed on the selective laser sintering and stereolithography rapid prototyping processes. A theoretical model for these processes is under development. Different rapid prototyping sites supplied test specimens (based on ASTM 638-84, Type I) that have been measured and tested to provide a data base on surface finish, dimensional variation and ultimate tensile strength. Further plans call for developing and verifying the theoretical models by carefully designed experiments. This will be a joint effort between NASA and other prototyping centers to generate a larger database, thus encouraging more widespread usage by product designers.

Cariapa, Vikram↗

Optical ordnance system for use in explosive ordnance disposal activities

A portable hand-held solid state rod laser system and an optically-ignited detonator have been developed for use in explosive ordnance disposal (EOD) activities. Laser prototypes from Whittaker Ordnance and Universal Propulsion have been tested and evaluated. The optical detonator contains 2-(5 cyanotetrazolato) pentaamine cobalt(III) perchlorate (CP) as the DDT column and the explosive Octahydro- 1,3,5,7 - tetrazocine (HMX) as the output charge. The laser is designed to have an output of 150 mJ in a 500 microsecond pulse. This output allows firing through 2000 meters of optical fiber. The detonator can also be ignited with a portable laser diode source through a shorter length of fiber.

Merson, J. A.↗

A Photometric Technique for Determining Fluid Concentration using Consumer-Grade Hardware

In support of a separate study to produce an exponential concentration gradient in a magnetic fluid, a noninvasive technique for determining, species concentration from off-the-shelf hardware has been developed. The approach uses a backlighted fluid test cell photographed with a commercial digital camcorder. Because the light extinction coefficient is wavelength dependent, tests were conducted to determine the best filter color to use, although some guidance was also provided using an absorption spectrophotometer. With the appropriate filter in place, the provide attenuation of the light passing, through the test cell was captured by the camcorder. The digital image was analyzed for intensity using, software from Scion Image Corp. downloaded from the Internet. The analysis provides a two-dimensional array of concentration with an average error of 0.0095 ml/ml. This technique is superior to invasive techniques, which require extraction of a sample that disturbs the concentration distribution in the test cell. Refinements of this technique using a true monochromatic laser light Source are also discussed.

Leslie, F.↗

A Phase Locked High Speed Real-Time Interferometry System for Large Amplitude Unsteady Flows

A high speed phase locked interferometry system has been designed and developed for real-time measurements of the dynamic stall flow over a pitching airfoil. Point diffraction interferograms of incipient flow separation over a sinusoidally oscillating airfoil have been obtained at rates of up to 20 KHz and for free stream Mach numbers of 0.3 and 0.45. The images were recorded on ASA 125 and ASA 400 film using a drum camera. Special electronic timing and synchronizing circuits were developed to trigger the laser light source from the camera, and to initiate acquisition of the interferogram sequence from any desired phase angle of oscillation. The airfoil instantaneous angle of attack data provided by an optical encoder was recorded via a FIFO and in EPROM into a microcomputer. The interferograms have been analyzed using software developed in-house to get quantitative flow density and pressure distributions.

Chandrasekhara, M. S.↗

Novel Diffusivity Measurement Technique

A common-path interferometer (CPI) system was developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. This system uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. Hence, the molecular diffusion coefficient of liquids can be determined using the physical relations between changes in the optical path length and the liquid phase properties. The data obtained with this interferometer were compared with similar results from other techniques and demonstrated that the instrument is superior in measuring the diffusivity of miscible liquids while keeping the system very compact and robust. CPI can also be used for studies in interface dynamics and other diffusion-dominated-process applications.

Rashidnia, Nasser↗

Implementation and Assessment of Advanced Analog Vector-Matrix Processor

This paper discusses the design and implementation of an analog optical vecto-rmatrix coprocessor with a throughput of 128 Mops for a personal computer. Vector matrix calculations are inherently parallel, providing a promising domain for the use of optical calculators. However, to date, digital optical systems have proven too cumbersome to replace electronics, and analog processors have not demonstrated sufficient accuracy in large scale systems. The goal of the work described in this paper is to demonstrate a viable optical coprocessor for linear operations. The analog optical processor presented has been integrated with a personal computer to provide full functionality and is the first demonstration of an optical linear algebra processor with a throughput greater than 100 Mops. The optical vector matrix processor consists of a laser diode source, an acoustooptical modulator array to input the vector information, a liquid crystal spatial light modulator to input the matrix information, an avalanche photodiode array to read out the result vector of the vector matrix multiplication, as well as transport optics and the electronics necessary to drive the optical modulators and interface to the computer. The intent of this research is to provide a low cost, highly energy efficient coprocessor for linear operations. Measurements of the analog accuracy of the processor performing 128 Mops are presented along with an assessment of the implications for future systems. A range of noise sources, including cross-talk, source amplitude fluctuations, shot noise at the detector, and non-linearities of the optoelectronic components are measured and compared to determine the most significant source of error. The possibilities for reducing these sources of error are discussed. Also, the total error is compared with that expected from a statistical analysis of the individual components and their relation to the vector-matrix operation. The sufficiency of the measured accuracy of the processor is compared with that required for a range of typical problems. Calculations resolving alloy concentrations from spectral plume data of rocket engines are implemented on the optical processor, demonstrating its sufficiency for this problem. We also show how this technology can be easily extended to a 100 x 100 10 MHz (200 Cops) processor.

Gary, Charles K.↗

Small Business Innovations

Under a Small Business Innovation Research (SBIR) contract to Kennedy Space Center, EIC Laboratories invented a Raman Spectrograph with fiber optic sampling for space applications such as sensing hazardous fuel vapors and making on-board rapid analyses of chemicals and minerals. Raman spectroscopy is a laser-based measurement technique that provides through a unique vibrational spectrum a molecular 'fingerprint,' and can function in aqueous environments. EIC combined optical fiber technology with Raman methods to develop sensors that can be operated at a distance from the spectrographic analysis instruments and the laser excitation source. EIC refined and commercialized the technology to create the Fiber Optic Raman Spectrograph and the RamanProbe. Commercial applications range from process control to monitoring hazardous materials.

Source record↗

Planar Particle Imaging and Doppler Velocimetry System and Method

A planar velocity measurement system (100) is operative to measure all three velocity components of a flowing fluid (106) across an illuminated plane (108) using only a single line of sight. The fluid flow is seeded with small particles which accurately follow the flow field fluctuations. The seeded flow field is illuminated with pulsed laser light source (102) and the positions of the particles in the flow are recorded on CCD cameras (122,124). The in-plane velocities are measured by determining the in-plane particle displacements. The out-of-plane velocity component is determined by measuring the Doppler shift of the light scattered by the particles. Both gas and liquid velocities can be measured, as well as two-phase flows.

Wernet, Mark P.↗

Measurement of the Specific Refractivities of CF4 and C2F6

In order to relate the measured fringe shift of an interferometer to density, the relation between density rho and refractive index n must be known. For gases where the refractive index is close to unity, this relation between density and refractive index is very closely approximated by (n - 1) = K rho where K is the specific refractivity, or the Gladstone-Dale constant. The specific refractivity, which is weakly dependent on wavelength and temperature, is readily available for a number of common test gases such as N2 and air. For more unique test gases such as CF4 and C2F6 for which refractive index data at optical wavelengths is not readily available, the constants can be estimated from the atomic refractivities of carbon and fluorine. In order to verify this estimation, a two-beam interferometer was used to experimentally determine the specific refractivities of CF4 and C2F6. This data was required for holographic interferometric measurements made at the Langley Hypersonic CF4 Tunnel. A Twyman-Green interferometer with a He-Ne laser light source of vacuum wavelength lambda equal to 633 nm was used to measure the constants. One beam of the two-beam interferometer passed through an optical cell of known inside length l which could be evacuated and slowly filled with the test gas to a density of 7.2 kg/cu m for CF4 or 5.7 kg/cu m for C2F6. If the refractive index (and hence density) is constant along the optical path through the cell, the fringe shift M and density change Delta rho are related M = 2Kl Delta rho/lambda for the double pass interferometer. Thus K can be determined by measuring the fringe shift as the density is changed. The output of a photodiode used to detect the fringe shift was recorded on a strip chart recorder. The rate of pressure increase of the test gas in the cell was controlled such that the fringes shifted at a rate of 0.5 to 1 fringe per sec. The pressure in the test cell was measured with a high accuracy quartz crystal pressure transducer and recorded approximately every 20 fringe peaks. The temperature of the cell was measured with a thermocouple and recorded at the start, midpoint, and end of each test.

Burner, A. W.↗

Response of Solid He-4 to External Stress: Interdigital Capacitor Solid Level Detector and Optical Interferometer

Two experiments are being conducted to observe the liquid/solid interface of He-4 near 1 K. Interesting instabilities are expected to occur when the solid is non-hydrostatically stressed. (1)A compact interdigital capacitor is used as a level detector to observe solid He-4 to which stresses are applied externally. The capacitor consists of 38 interlaced 50 m wide and 3.8 mm long gold films separated by 50 m and deposited onto a 5 mm by 5 mm sapphire substrate. The capacitor is placed on one flat end wall of a cylindrical chamber (xx mm diameter and xx mm long). The solid is grown to a known height and a stress is applied by a tubular PZT along the cylindrical axis. The observed small change in height of the solid at the wall is linearly proportional to the applied stress. The solid height decreases under compressive stress but does not change under tensile stress. The response of the solid on compressive stress is consistent with the expected quadratic dependence on strain. (2)Interferometric techniques are being developed for observing the solid He-4 surface profile. A laser light source is brought into the low temperature region via single mode optical fiber. The interference pattern is transmitted back out of the low temperature apparatus via optical fiber bundle. The solid He-4 growth chamber will be equipped with two PZT's such that stress can be applied from orthogonal directions. Orthogonally applied stress is expected to induce surface instability with island-like deformation on a grid pattern. Apparatus design and progress of its construction are described.

Fay, J.↗

Diffusivity Measurements Made Instant and Easy

A compact common path interferometer (CPI) system has been developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. It uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. The molecular diffusion coefficient of liquids can be determined from the physical relations between changes in the optical path length and liquid phase properties. When the data obtained by using the CPI have been compared with similar results from other techniques, the instrument has been demonstrated to be far superior to other instruments for measuring the diffusivity of miscible liquids while staying very compact and robust (ref. 1). Because of its compactness and ease of use, the CPI has been adopted for use in studies of interface dynamics as well as other diffusion-controlled process applications (ref. 2). This progress will permit experiments in microgravity that can quantitatively answer basic science questions about mass and thermal diffusion and their effect in transport processes. This instrument is a spinoff of a diagnostic development for microgravity fluid physics experiments at the NASA Glenn Research Center that has used optics and electronics existing in the fluid physics laboratory for feasibility studies. Optical diagnostic techniques have become an integral part of many areas of measurement applications in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used as instruments for measuring optical wave fronts for lens testing and combustion and fluid flow diagnostics. One of these, the point diffraction interferometer, is considered to be robust (see, for example, ref. 3) because it has a common-path design. The point diffraction interferometer is difficult to align and has a limited measurement range for liquid-phase applications. Interferometry and schlieren techniques have been widely used for many years for gas-flow-visualization. On the other hand, the CPI, which is basically a Wollaston prism Polarizer in combination with an analyser (crystalline quartz retardation plate) is used instead of a point diffraction interferometer unit. The advantage of using the CPI over other optical techniques is that it can make quantitative measurements in liquids with the large index of refraction variations that often occur in interface dynamics studies. This can be simply accomplished by using different prism polarizers for each particular experimental condition.

Rashidnia, Nasser↗

NASA Tech Briefs, January 2010

Topics covered include: Cryogenic Flow Sensor; Multi-Sensor Mud Detection; Gas Flow Detection System; Mapping Capacitive Coupling Among Pixels in a Sensor Array; Fiber-Based Laser Transmitter for Oxygen A-Band Spectroscopy and Remote Sensing; Low-Profile, Dual-Wavelength, Dual-Polarized Antenna; Time-Separating Heating and Sensor Functions of Thermistors in Precision Thermal Control Applications; Cellular Reflectarray Antenna; A One-Dimensional Synthetic-Aperture Microwave Radiometer; Electrical Switching of Perovskite Thin-Film Resistors; Two-Dimensional Synthetic-Aperture Radiometer; Ethernet-Enabled Power and Communication Module for Embedded Processors; Electrically Variable Resistive Memory Devices; Improved Attachment in a Hybrid Inflatable Pressure Vessel; Electrostatic Separator for Beneficiation of Lunar Soil; Amorphous Rover; Space-Frame Antenna; Gear-Driven Turnbuckle Actuator; In-Situ Focusing Inside a Thermal Vacuum Chamber; Space-Frame Lunar Lander; Wider-Opening Dewar Flasks for Cryogenic Storage; Silicon Oxycarbide Aerogels for High-Temperature Thermal Insulation; Supercapacitor Electrolyte Solvents with Liquid Range Below -80 C; Designs and Materials for Better Coronagraph Occulting Masks; Fuel-Cell-Powered Vehicle with Hybrid Power Management; Fine-Water-Mist Multiple-Orientation-Discharge Fire Extinguisher; Fuel-Cell Water Separator; Turbulence and the Stabilization Principle; Improved Cloud Condensation Nucleus Spectrometer; Better Modeling of Electrostatic Discharge in an Insulator; Sub-Aperture Interferometers; Terahertz Mapping of Microstructure and Thickness Variations; Multiparallel Three-Dimensional Optical Microscopy; Stabilization of Phase of a Sinusoidal Signal Transmitted Over Optical Fiber; Vacuum-Compatible Wideband White Light and Laser Combiner Source System; Optical Tapers as White-Light WGM Resonators; EPR Imaging at a Few Megahertz Using SQUID Detectors; Reducing Field Distortion in Magnetic Resonance Imaging; Fluorogenic Cell-Based Biosensors for Monitoring Microbes; A Constant-Force Resistive Exercise Unit; GUI to Facilitate Research on Biological Damage from Radiation; On-Demand Urine Analyzer; More-Realistic Digital Modeling of a Human Body; and Advanced Liquid-Cooling Garment Using Highly Thermally Conductive Sheets.

Source record↗

Miniature Laser Magnetometer

A conceptual design has been developed for a miniature laser magnetometer (MLM) that will measure the scalar magnitude and vector components of near-Earth magnetic fields. The MLM incorporates a number of technical innovations to achieve high-accuracy and high-resolution performance while significantly reducing the size of the laser-pumped helium magnetometer for use on small satellites and unmanned aerial vehicles (UAVs). and electronics sections that has the capability of measuring both the scalar magnetic field magnitude and the vector magnetic field components. Further more, the high-accuracy scalar measurements are used to calibrate and correct the vector component measurements in order to achieve superior vector accuracy and stability. The correction algorithm applied to the vector components for calibration and the same cell for vector and scalar measurements are major innovations. The separate sensor and electronics section of the MLM instrument allow the sensor to be installed on a boom or otherwise located away from electronics and other noisy magnetic components. The MLM s miniaturization will be accomplished through the use of advanced miniaturized components and packaging methods for the MLM sensor and electronics. The MLM conceptual design includes three key innovations. The first is a new non-magnetic laser package that will allow the placement of the laser pump source near the helium cell sensing elements. The second innovation is the design of compact, nested, triaxial Braunbek coils used in the vector measurements that reduce the coil size by a factor of two compared to existing Helmholtz coils with similar field-generation performance. The third innovation is a compact sensor design that reduces the sensor volume by a factor of eight compared to MLM s predecessor.

Slocum, Robert↗

Pressure-Sensitive Paints Advance Rotorcraft Design Testing

The rotors of certain helicopters can spin at speeds as high as 500 revolutions per minute. As the blades slice through the air, they flex, moving into the wind and back out, experiencing pressure changes on the order of thousands of times a second and even higher. All of this makes acquiring a true understanding of rotorcraft aerodynamics a difficult task. A traditional means of acquiring aerodynamic data is to conduct wind tunnel tests using a vehicle model outfitted with pressure taps and other sensors. These sensors add significant costs to wind tunnel testing while only providing measurements at discrete locations on the model's surface. In addition, standard sensor solutions do not work for pulling data from a rotor in motion. "Typical static pressure instrumentation can't handle that," explains Neal Watkins, electronics engineer in Langley Research Center s Advanced Sensing and Optical Measurement Branch. "There are dynamic pressure taps, but your costs go up by a factor of five to ten if you use those. In addition, recovery of the pressure tap readings is accomplished through slip rings, which allow only a limited amount of sensors and can require significant maintenance throughout a typical rotor test." One alternative to sensor-based wind tunnel testing is pressure sensitive paint (PSP). A coating of a specialized paint containing luminescent material is applied to the model. When exposed to an LED or laser light source, the material glows. The glowing material tends to be reactive to oxygen, explains Watkins, which causes the glow to diminish. The more oxygen that is present (or the more air present, since oxygen exists in a fixed proportion in air), the less the painted surface glows. Imaged with a camera, the areas experiencing greater air pressure show up darker than areas of less pressure. "The paint allows for a global pressure map as opposed to specific points," says Watkins. With PSP, each pixel recorded by the camera becomes an optical pressure tap. "Instead of having 100 or 200 pressure taps, you can have in theory several million, up to whatever the resolution of your camera is." Watkins explains that typical wind tunnel testing requires two models: one with very little instrumentation, and a pressure model with a significant amount of sensors applied. "If you can make all of your measurements on one model with PSP, you've decreased your model costs by at least a factor of two and preferably your testing costs by about that much," he says. PSP technology has been around for almost 20 years, but a PSP solution for gathering instantaneous dynamic pressure data from surfaces moving at high speeds, such as rotor blades, was not available until a NASA partnership led to a game-changing innovation.

Source record↗