Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Advances in plasma–wall interaction control for H-mode operation over 100 s with ITER-like tungsten divertor on EAST

A total power injection up to 0.3 GJ has been achieved in EAST long pulse H-mode operation of 101.2 s with an ITER-like water-cooled tungsten (W) mono-block divertor, which has steady-state power exhaust capability of 10 MWm –2 . The peak temperature of W target saturated at 12 s to the value T ~ 500 °C with a heat flux ~3.3 MW m –2 being maintained during the discharge. By tailoring the 3D divertor plasma footprint through edge magnetic topology change, the heat load was broadly dispersed and thus peak heat flux and W sputtering were well controlled. Active feedback control of H-mode detachment with D 2 fuelling or divertor impurity seeding has been achieved successfully, with excellent compatibility with the core plasma performance. Active feedback control of radiative power utilizing neon seeding was achieved with f rad = 18%–41% in H-mode operation, exhibiting potential for heat flux reduction with divertor and edge radiation. This has been further demonstrated in DIII-D high β P H-mode scenario within the joint DIII-D/EAST experiment using impurity seeding from the divertor volume. Steady-state particle control and impurity exhaust has been achieved for long pulse H-mode operation over 100 s with the W divertor by leveraging the effect of drifts and optimized divertor configuration, coupled with strong pumping and extensive wall conditioning. Methods toward the reduction of divertor W sourcing, which is of crucial importance for a metal-wall tokamak, are also explored. These advances provide vital experimental information on favourable core-edge integration for high power, long-pulse H-mode operation in EAST, ITER and CFETR.

43 PARTICLE ACCELERATORS↗

Performance-Based Evaluation of Courtyard Design in China’s Cold-Winter Hot-Summer Climate Regions

A courtyard is a traditional and popular construction feature found in China’s urban buildings. This case study evaluates the performance of the traditional courtyard design of the Jiangnan Museum, located in Jiangsu Province. In the evaluation, the spatial layout of courtyards is adjusted, the aspect ratio is changed, and an ecological buffer space is created. To model and evaluate the performance of the courtyard design, this study applied the Computational fluid dynamics (CFD) software, Parabolic Hyperbolic Or Elliptic Numerical Integration Code Series (PHOENICS), for wind environment simulation, and the EnergyPlus-based software, DesignBuilder, for energy simulation. Results show that a good combination of courtyard layout and aspect ratio can improve the use of natural ventilation by increasing free cooling during hot summers and reducing cold wind in winters. The results also show that ecological buffer areas of a courtyard can reduce cooling loads in summer by approximately 19.6% and heating loads in winter by approximately 22.3%. The study provides insights into the optimal design of a courtyard to maximize its benefit in regulating the microclimate during both winter and summer.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat transfer and core neutronics considerations of the heat pipe cooled thermionic reactor

The authors summarize the results of detailed neutronic and thermal-hydraulic evaluations of the heat pipe cooled thermionic (HPTI) reactor design, identify its key design attributes, and quantify its performance characteristics. The HPTI core uses modular, liquid-metal core heat transfer assemblies to replace the liquid-metal heat transport loop employed by in-core thermionic reactor designs of the past. The nuclear fuel, power conversion, heat transport, and heat rejection functions are all combined into a single modular unit. The reactor/converter assembly uses UN fuel pins to obtain a critical core configuration with in-core safety rods and reflector controls added to complete the subassembly. By thermally bonding the core heat transfer assemblies during the reactor core is coupled neutronically, thermally, and electrically into a modular assembly of individual power sources with cross-tied architecture. A forward-facing heat pipe radiator assembly extends from the reactor head in the shape of a frustum of a cone on the opposite side of the power system from the payload. Important virtues of the concept are the absence of any single-point failures and the ability of the core to effectively transfer the TFE waste heat load laterally to other in-core heat transfer assemblies in the event of multiple failures in either in-core and radiator heat pipes.

Determan, W. R.↗

Aeroheating Predictions for the X-43 Cowl-Closed Configuration at Mach 7 and 10

A pre-flight analysis was conducted for the Mach 7 and Mach 10 X-43 cowl-closed configurations to evaluate three-dimensional flow-field effects on localized heating in the vicinity of the closed cowl flap and sidewall. First, engineering-level analyses based on documented laminar and turbulent surface heating database were used to estimate localized heating amplification factors to account for turbulent flow effects, corner flow effects and the presence of forebody boundary layer trip devices. These estimated factors were applied to 2-D computational predictions to develop surface heat loads. Second, thin-film gauge surface heating data were obtained for a Mach 10 cowl-closed configuration in a reflected shock tunnel at simulated flight conditions. Third, computational fluid dynamics (CFD) flow-field predictions were obtained at Mach 10 ground test conditions to provide comparisons with the engineering database predictions and experimental measurements. Similarly, a CFD solution was also obtained at Mach 7 flight conditions to provide qualitative comparisons with engineering predictions. The Mach 10 CFD predictions compare favorably with the experimental measurements and the engineering estimates for surface heating amplification on the closed cowl. However, experimental measurements were not of sufficient quantity on the sidewall surface to capture the highest localized heating rates, and also the Mach 10 CFD predictions suggest higher peak heating on the sidewall compared to the engineering estimates. Also, the Mach 7 CFD predictions indicate qualitative agreement with the database estimates in terms of flow-field structure and peak heating locations on the closed-cowl flap and sidewall surfaces.

Cockrell, Charles E., Jr.↗

Working Fluids for Increasing Capacities of Heat Pipes

A theoretical and experimental investigation has shown that the capacities of heat pipes can be increased through suitable reformulation of their working fluids. The surface tensions of all of the working fluids heretofore used in heat pipes decrease with temperature. As explained in more detail below, the limits on the performance of a heat pipe are associated with the decrease in the surface tension of the working fluid with temperature, and so one can enhance performance by reformulating the working fluid so that its surface tension increases with temperature. This improvement is applicable to almost any kind of heat pipe in almost any environment. The heat-transfer capacity of a heat pipe in its normal operating-temperature range is subject to a capillary limit and a boiling limit. Both of these limits are associated with the temperature dependence of surface tension of the working fluid. In the case of a traditional working fluid, the decrease in surface tension with temperature causes a body of the liquid phase of the working fluid to move toward a region of lower temperature, thus preventing the desired spreading of the liquid in the heated portion of the heat pipe. As a result, the available capillary-pressure pumping head decreases as the temperature of the evaporator end of the heat pipe increases, and operation becomes unstable. Water has widely been used as a working fluid in heat pipes. Because the surface tension of water decreases with increasing temperature, the heat loads and other aspects of performance of heat pipes that contain water are limited. Dilute aqueous solutions of long-chain alcohols have shown promise as substitutes for water that can offer improved performance, because these solutions exhibit unusual surface-tension characteristics: Experiments have shown that in the cases of an aqueous solution of an alcohol, the molecules of which contain chains of more than four carbon atoms, the surface tension increases with temperature when the temperature exceeds a certain value. There are also other liquids that have surface tensions that increase with temperature and could be used as working fluids in heat pipes. For example, as a substitute for ammonia, which is the working fluid in some heat pipes, one could use a solution of ammonia and an ionic surfactant.

Chao, David F.↗

Backshell Radiation Analysis with US3D

During atmospheric entry, radiative heat flux can be a dominant heat transfer mechanism acting on the after-body of the space vehicle. Though the magnitude of radiative heat flux is small, the materials used on the back shell are designed to accommodate smaller heat loads. Therefore, an accurate estimation of radiative heat flux is required. For MSL, Brandis et al.1 performed radiation analysis on the afterbody of the vehicle. They used full angular integration to accurately calculate the radiative heat flux at multiple body points. The above analysis was performed on structured CFD solutions, and the present work applies the same type of analysis to unstructured solutions using US3D.

Raghava S C Davuluri↗

Built-in Thermionic Electron Source for an SRF Linacs

The design of a thermionic electron source connected directly to a superconducting cavity, the key part of an SRF gun, is described. The results of beam dynamics optimization are presented which allow lack of beam current intercepting in the superconducting cavity. The electron source concept is presented including the cathode-grid assembly, thermal insulation of the cathode from the cavity, and the gun resonator design. The cavity thermal load caused by the gun is analyzed including the static heat load, black body radiation, backward electron heating, etc.

43 PARTICLE ACCELERATORS↗

Numerical Assessment of the Diagnostic Capabilities of the Instrumented Calorimeter for SPIDER (STRIKE)

An important feature of the ITER project is represented by additional heating via injection of neutral beams from accelerated negative ions. To study and optimise their production, the SPIDER test facility is under construction in Padova, with the aim of testing beam characteristics and to verify the source proper operation.STRIKE (Short-Time Retractable Instrumented Kalorimeter Experiment) is a diagnostic to characterise the SPIDER negative ion beam during short operation (several seconds). During long pulse operations, STRIKE is parked off-beam in the vacuum vessel. The most important measurements are beam uniformity, beamlet divergence and stripping losses. STRIKE is directly exposed to the beam and is formed of 16 tiles, one for each beamlet groups. The measurements are provided by thermal cameras, current sensors, thermocouples and electrostatic sensors. This paper presents the investigation of the influence on the response of STRIKE of: thermal characteristics of the tile material, exposure angle, features of some dedicated diagnostics. The uniformity of the beam will be studied by measurements of the current flowing through each tile and by thermal cameras. Simulations show that it will be possible to verify experimentally whether the beam meets the ITER requirement about the maximum allowed beam non-uniformity (below {+-}10%). In the simulations also the influence of the beam halo has been included; the effect of off-perveance conditions has been studied. To estimate the beamlet divergence, STRIKE can be moved along the beam direction at two different distances from the accelerator. The optimal positions have been defined taking into account design constraints. The effect of stripping on the comparison between currents and heat loads has been assessed; this will allow to obtain an experimental estimate of stripping. Electrostatic simulations have provided the suitable tile biasing voltage in order to reabsorb secondary particles into the same tile as the one where they were emitted from.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cryodeposition of nitrogen gas on a surface cooled by helium II

Catastrophic loss of beam tube vacuum in a superconducting particle accelerator can be simulated by sudden venting of a long high vacuum channel cooled on its outer surface by He II. The rapid rush of atmospheric air in such an event shows an interesting propagation effect, which is much slower than the shock wave that occurs with vacuum loss at ambient conditions. This is due to flash frosting/deposition of air on the cold walls of the channel. Hence to characterize the propagation as well as the associated heat transfer, it is first necessary to understand the deposition process. Here we attempt to model the growth of nitrogen frost layer on a cold plate in order to estimate its thickness with time. The deposition process can be divided into two regimes- free molecular and continuum. It is shown that in free molecular regime, the frost growth can be modeled reasonably well using cryopump theory and general heat transfer relations. The continuum regime is more complex to model, given the higher rate of gas incident on cryosurface causing a large heat load on helium bath and changing cryosurface temperature. Results from the continuum regime are discussed in the context of recent experiments performed in our laboratory.

43 PARTICLE ACCELERATORS↗

Intermittency Model for Coupled CFD-Stability Transition Analysis in Hypersonic Flow

Accurate prediction of aerothermodynamic loads on hypersonic vehicles requires precise modeling of surface quantities across the boundary layer transition zone. The peak heating loads and total heat transfer are determined by parameters such as the transition zone length and the magnitude of potential overshoots in heat flux and skin friction beyond their respective values in fully turbulent flows. While previous studies on CFD integrated transition modeling using linear stability correlations have shown promise in modeling these features, they did not develop an intermittency model for hypersonic flows. This paper presents a data-driven approach to develop a model of this type by correlating experimental transition data with the relevant flow parameters. The resulting model demonstrates significant improvements over previous low-speed models in terms of predicting heat transfer distributions during the transition process associated with first and second mode instabilities in axisymmetric high-speed flows. Separate correlations for flight and ground test conditions are developed, and the potential to combine these correlations is discussed.

Transition↗

Measurement of effect of electron cyclotron heating in a tandem mirror plasma using a semiconductor detector array and an electrostatic energy analyzer

Temporally and spatially resolved soft x-ray and end-loss-electron analyses of the electron cyclotron heated plasmas are carried out by using a semiconductor detector array and an electrostatic energy analyzer in the GAMMA 10 tandem mirror. The flux and the energy spectrum of the end loss electrons are measured by a multi-grid energy analyzer. Recently, the electron cyclotron heating power modulation experiments have been started in order to generate and control the high heat flux and to make the edge localized mode-like intermittent heat load pattern for the divertor simulation studies by the use of these detectors for electron properties.

43 PARTICLE ACCELERATORS↗

Numerical Modeling of Edge-Localized-Mode Filaments on Divertor Plates Based on Thermoelectric Currents

Edge localized modes (ELMs) are qualitatively and quantitatively modeled in tokamaks using current bursts which have been observed in the scrape-off-layer (SOL) during an ELM crash. During the initial phase of an ELM, a heat pulse causes thermoelectric currents. They first flow in short connection length flux tubes which are initially established by error fields or other nonaxisymmetric magnetic perturbations. The currents change the magnetic field topology in such a way that larger areas of short connection length flux tubes emerge. Then currents predominantly flow in short SOL-like flux tubes and scale with the area of the flux tube assuming a constant current density. Quantitative predictions of flux tube patterns for a given current are in excellent agreement with measurements of the heat load and current flow at the DIII-D target plates during an ELM cycle.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of 1 MeV H{sup -} Accelerator at JAEA for ITER NB

This paper reports the recent activities at JAEA for the development of 1 MeV H{sup -} ion accelerator toward the ITER NBI. For the development of MAMuG accelerator, a 320 mA H{sup -} ion beam was successfully accelerated as the highest record in the world at the MeV class energy (796 keV). This was achieved by protecting the H{sup -} ion source from the high heat load by the backstream positive ions, which was produced during the high current H{sup -} ion acceleration. The SINGAP accelerator was tested at JAEA to compare the performance of the SINGAP and the MAMuG. This paper also reports the results of the SINGAP test and the comparison between the SINGAP and the MAMuG is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling Advanced Strippers for CO2 Capture from Gas-Fired Power Plants using Aqueous Piperazine

Energy performance of 5 m piperazine was evaluated with an advanced stripper at the pilot scale, accounting for heat loss. Modeling studies indicated that heat loss at locations other than the heat source impacted the heat duty. For strippers with excess packing, the column was the most important source of heat loss, and values as low as 0.03 GJ/hr can cause pinch and reabsorption of CO2. Solvents like 5 m PZ are more affected by heat loss in the column due to a top-side temperature pinch at high lean loading. Heat loss impacts NGCC CO2 capture more than coal-based CO2 capture. Surface temperature measurements pilot plants showed that heat loss was 50-75% controlled by natural convection. Measured heat loss was correlated with steam flowrate and wind speed and ranged from 8126 to 219668 Btu/hr, representing 35% of the measured heat rate on average. Net heat duty linearly varied with CO2 removal at low lean loading and was similar for coal and NGCC conditions at fixed removal. At 90% removal, net heat duty was about 2.5 GJ/t with 4 and 12% CO2 in the flue gas. 7 At NGCC conditions, strippers with finite packing can benefit from a flashing feed to the top of the column by using a hot bypass. A flashing feed was linked to a reduction in irreversibility of the stripper from temperature driving forces. It also reduces heat duty by up to 6% at fixed packing height and reduces packing requirement for a fixed steam heater size compared to a warm bypass. Lean loading and lean solvent rate were effective handles to maximize profitability of a fixed stripper design at low gas price. High ambient temperature operation can benefit from low pressure stripping to about 0.18 lean loading at 150 ℃ to maintain the cyclic capacity at reduced rich loading. At low gas price, the capture plant was able to maximize profitability even with a high heat duty of 2.7-3.1 GJ/t at a lean loading of 0.2-0.22 mol/mol. Heat recovery by partial water vapor condensation in a gas-liquid exchanger can be replaced by a direct contact condenser (DCC). The DCC improved gas cooling and reduced heat duty compared to the CO2 exchanger at 0.2 lean loading. The DCC when used with a 150 ℃/5.5 bar stripper can reduce the cost of capture compared to the base case by $3- 4/tonne at 15 ft of packing (optimum) but increases cost of capture by $6/tonne with a 120 ℃/2 bar stripper and 10 ft of packing (optimum). The DCC can work effectively with a solvent with a high heat of absorption and thermal stability.

Suresh Babu, Athreya↗

An alpha particle measurement system using an energetic neutral helium beam in ITER (invited)

An energetic helium neutral beam is involved in the beam neutralization measurement system of alpha particles confined in a DT fusion plasma. A full size strong-focusing He{sup +} ion source (2 A, the beam radius of 11.3 mm, the beam energy less than 20 keV). Present strong-focusing He{sup +} ion source shows an emittance diagram separated for each beamlet of multiple apertures without phase space mixing, despite the space charge of a beamlet is asymmetric and the beam flow is non-laminar. The emittance of beamlets in the peripheral region was larger than that of center. The heat load to the plasma electrode was studied to estimate the duty factor for the ITER application.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improvement of accelerator of negative ion source on the Large Helical Device

To improve the performance of negative-ion based neutral beam injection on the Large Helical Device, the accelerator was modified on the basis of numerical investigations. A field limiting ring was installed on the upper side of a grounded grid (GG) support and a multi-slot GG was adopted instead of a multi-aperture GG. As a result, the voltage holding capability is improved and the heat load on the GG decreases by 40%. In addition, the arc efficiency is improved significantly only by replacing the GG.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial measurements of fast ion loss in KSTAR

A fast ion loss detector (FILD) has been installed and tested in Korea Superconducting Tokamak Advanced Research (KSTAR). KSTAR FILD measures the energy and the pitch-angle of the escaping ions with the striking positions on the scintillator plane. Measurements of the fast ion loss have been performed for the neutral beam heated plasmas. Initial experimental results indicate the prompt losses from neutral beam are dominant and the effects of the resonant magnetic perturbation on the fast ion loss are investigated. In addition, further design change of the detector-head in order to avoid excessive heat load and to detect the fusion products or the fast ions having order of MeV of energy is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗