Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Atomistic insights into the heat conductance across the interfaces between erythritol and different metals: A non-equilibrium molecular dynamics study

The heat conductance across the interface between a phase change material (PCM) and the metal shell is important for thermal design of latent heat storage systems. Non-equilibrium molecular dynamics simulations were carried out in this work to unravel, at the atomistic level, the interfacial heat conductance mechanisms between erythritol (the most promising medium-temperature polyol PCM) and two different metals (i.e., copper and aluminum). The interfacial contact ratio was introduced as a parameter to represent different contact conditions at the interfaces, for example, different surface roughness levels of the metals. It was found that with the increase of interfacial contact ratio, the temperature difference between the erythritol/metal interfaces decreases, whereas the interfacial heat transfer coefficient increases gradually. At the perfect contact condition, i.e., the interfacial contact ratio reaches 100%, the interfacial heat transfer coefficients across the erythritol/Cu and erythritol/Al interfaces were predicted to be 398 ± 26 MW/m 2 K and 544 ± 11 MW/m 2 K, respectively. The interfacial heat conductance of erythritol/Al is better than that of erythritol/Cu. The mismatch of atomic spectral density across the interfaces between erythritol and the two metals was analyzed and distinguished. These results could guide the selection of packaging materials and the thermal design of erythritol-based latent heat storage systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermodynamic analysis and optimization of supercritical carbon dioxide Brayton cycles for use with low-grade geothermal heat sources

The transcritical carbon dioxide Rankine cycle has emerged as an alternative for power generation in low-grade heat applications. However, the low heat rejection temperatures required for condensing the carbon dioxide is almost prohibitive for many locations. A simple solution is the adoption of a supercritical carbon dioxide Brayton cycle which does not need such low temperature heat sinks. This power cycle has been poorly studied previously in low-grade heat applications. Therefore, with the aim of determining the performance and feasibility of the supercritical carbon dioxide Brayton cycle from thermodynamic viewpoint, using a low-grade geothermal heat source, this paper presents a comparative thermodynamic analysis between four different supercritical carbon dioxide Brayton cycles. For this purpose, detailed models were developed and solved by coupling the thermodynamic model with the thermal-hydraulic model of a Printed Circuit Heat Exchanger. Subsequently, simulations of a base case, a parametric analysis, and an optimization using Genetic Algorithms, were carried out. Results show that there is a combination of operating conditions that maximizes the electrical output of the system. Besides, some values of the minimum pressure of the cycles can increase substantially the precooler cooling water pumping power. At the optimum design point, using a 20 kg/s geothermal brine stream at 150 °C as heat source with a minimum allowable reinjection temperature of 70 °C, the Intercooled Recuperated Brayton Cycle achieved the highest electric power output, energy and exergy efficiencies, obtaining values of 779.99 kW, 11.51%, and 52.49%, respectively. The other feasible alternatives were the Recuperated Brayton Cycle, the Simple Brayton Cycle and the Intercooled Brayton Cycle, ranked, in that order.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY↗

Convective heat transfer enhancement through additively built multiscale micro-tetrahedron features

Use of Additive Manufacturing (AM) to improve the heat transfer characteristics of tip shrouds in high-pressure turbines is being considered by industries. Existing designs of these components integrate micro-cooling channels to reduce the bulk temperature for improved life. In this research, closely packed micro tetrahedron features in addition to AM roughness has been considered. Further, this multiscale surface characteristics increased surface area per unit volume available for heat exchange. Micro-tet features were designed, manufactured, characterized, and evaluated systematically while increasing their height. An enormous increase in the overall wetted surface area by 200 % was measured. The convective heat transfer enhancement was ~3.72 times EDM rough coupon, and friction factor enhancement was ~5.5 times EDM rough coupon. Furthermore, the proposed design offers 2.5 times enhanced heat transfer for a given 2 W pumping power compared to our EDM rough coupon. Heat transfer enhancement was observed to not vary strongly with increased Reynolds number. Such complex designs are only possible through additive manufacturing for increased heat transfer with little pressure penalty. Finally, increasing the micro-tet height for increased surface area and improved heat exchange beyond an upper limit might not be a significant benefit as it gets compensated by increasing skin friction.

42 ENGINEERING↗

Thermohydraulic experiments on a supercritical carbon dioxide–air microtube heat exchanger

Heat exchangers are critical components in supercritical CO 2 Brayton cycles and provide necessary heat input, recovery, and dissipation. Tubular heat exchangers with unconventionally small tube sizes (tube diameters less than 5 mm) are promising components for supercritical CO 2 cycles and potentially provide excellent structural stability with wide scope of application. This paper provides essential design and fabrication guidelines for a compact shell-and-tube heat exchanger with microtubes (with an inner diameter equal to 1.75 mm). A heat exchanger test rig is used to evaluate the thermohydraulic performance of this heat exchanger with supercritical CO 2 and air as working fluids. Thermohydraulic data are reported for more than forty sets of experiments with varying Reynolds numbers for shell and tube flows. Critical performance metrics are calculated from the data and compared with predictions from a previously described numerical model. The average deviations between the experimental and model results fall within 10% for all critical metrics. This excellent agreement validates the numerical model for supercritical CO 2 heat exchanger optimization and scale-up.

42 ENGINEERING↗

Effect of heat treatment on creep behavior of 316 L stainless steel manufactured by laser powder bed fusion

The objective of this study is to understand the thermal stability of microstructure and its effect on the creep behavior of additively-manufactured 316L stainless steel (AM 316L SS). Creep specimens were fabricated from rods printed by a laser powder bed fusion process. Six different heat treatments, namely 650 °C/1 h, 700 °C/1 h, 750 °C/1 h, 800 °C/1 h, 900 °C/1 h and 1050 °C/1 h were applied to the creep specimens. The heat-treated specimens were creep-tested under the same condition, 550 °C/275 MPa to evaluate the effect of post-build heat treatment on the creep behavior of AM 316L SS. In the temperature range of 650-750 °C, dislocation density within cells, and cell size and wall thickness were affected by the heat treatment, while elemental segregation at boundaries remained unchanged and Mn-enriched Si oxide particles remained stable. In the temperature range of 750-900 °C, concurrent changes were observed in dislocation cell structures, elemental segregation and oxide particles. The 1050 °C-heat treatment removed cell structures and boundary solute segregations, leading to formation of equiaxed grains; Mn-enriched Si oxide particles in the as-built specimen were replaced by more stable Mn-enriched Cr oxides. The creep life of AM 316L SS increased after the heat treatment at 650 °C and then decreased with increasing temperature up to 900 °C where cell/subgrain structures still existed. The creep rate and creep elongation followed an opposite trend. The creep rate can be correlated with the structural parameters of cell/subgrain size and cell wall/boundary thickness and can be rationalized by different strengthening mechanisms of dislocation cells and subgrains. The heat treatment affected strongly the primary and secondary creep but had a minimal effect on the tertiary creep of AM 316L SS.

316L stainless steel↗

Assessing the impacts of air-sealing on the sizing, operation, and economic feasibility of ground-source heat pumps for electrifying single-family houses in the US

According to recent studies and reports, in single-family houses (SFHs), air-sealing can significantly lower the thermal loads for space heating and cooling. Thus, air-sealing in SFHs could reduce the required size and cost of ground source heat pump (GSHP) systems for electrifying SFHs. Here, this study investigated the costs and benefits of integrating air-sealing with GSHPs for retrofitting existing SFHs when compared with air-source heat pumps. A whole building energy simulation tool integrated with an advanced design tool for modeling ground heat exchangers was used to calculate changes in required GSHP capacity, total borehole length, and building energy consumption with and without air-sealing in SFHs in 16 US climatic regions. The results from this study showed that reducing outdoor air infiltration from 0.8 air changes per hour (ACH) to the minimum ventilation requirement (0.35 ACH) can significantly reduce borehole length (up to 55 %), GSHP capacity (up to 48 %), and total heating electricity reduction, especially in cold climates (up to 44 %). The results also showed that for airtight homes (0.03 ACH infiltration) with a direct outdoor air system, the minimum required borehole length, GSHP capacity, and total heating electricity consumption can be reduced up to 70 %, 68 %, and 67 %, respectively, when compared with SFHs with 0.8 ACH infiltration. Moreover, the life cycle cost analysis showed that air-sealing in conjunction with a GSHP is more profitable than replacing the existing system with an air-source heat pump, even without any incentives for most climatic regions in the US (except for some hot regions).

15 GEOTHERMAL ENERGY↗

Heat generation in electric double layer capacitors with neat and diluted ionic liquid electrolytes under large potential window between 5 and 80 °C

Here, this study investigates the effect of temperature on the heat generation and the associated electrochemical phenomena occurring in IL-based EDLCs. The EDLCs consisted of two identical activated carbon electrodes with neat Pyr14TFSI or Pyr14TFSI diluted in propylene carbonate (PC) as electrolytes. The instantaneous heat generation rate at each electrode was measured by isothermal calorimetry between 5 and 80 °C under constant current cycling and potential window of 2.5 V. First, the instantaneous heat generation rate was similar at each electrode in neat IL. However, it was smaller at the negative electrode in diluted IL and featured endothermic dips growing with increasing temperature > 40 °C due to overscreening effects, ion desolvation, and/or decomposition of PC. The irreversible heat generation was similar in each half-cell and decreased with increasing temperature due to the reduction in internal resistance, particularly with neat IL. The irreversible heat generation exceeded Joule heating in all cases, especially at high temperature and low current. This was attributed to ion desorption and charge redistribution in the porous electrodes. Finally, the reversible heat generation for both electrolytes was larger at the positive than at the negative electrode due to the difference in anion and cation sizes.

25 ENERGY STORAGE↗

Synthesis and post-heating treatment of inorganic NaF·Na 3 SbS 4 solid electrolytes

Sulfide-type sodium (Na) solid electrolytes (SEs) with halide doping have attracted serious interest due to their high ionic conductivity and great potential in solid-state Na batteries. While other halogens such as Cl, Br, I have been studied to enhance Na-ion transport in sulfide-type SEs, the introduction of fluorine (F) is rarely investigated. Moreover, synthetic parameters such as heating treatment temperatures strongly influence the structure and conductive properties of halide-doped sulfide SEs. Herein, we prepared xNaF·(1-x)Na 3 SbS 4 nanocomposites with varying concentration of F using a low-temperature (150 °C) heating method, and studied the effects of post-heating treatment on structure and conductivity. In-situ neutron diffraction was employed to investigate the structural evolution of X-doped Na 3 SbS 4 (X = F, Cl) during the post-heating treatment and cooling process. In addition, the post-heating treatment at 300 °C leads to increased ionic conductivity of xNaF·(1-x)Na 3 SbS 4 nanocomposites with various F contents. After 300 °C post-heating treatment, 0.2NaF·0.8Na 3 SbS 4 exhibited the highest conductivity of 0.48 mS cm –1 at room temperature. Moreover, improved electrochemical stability was also observed in Na-Sn symmetric cells, specially, with prolonged stable cycling for 300 h and much lower polarization voltage (<0.35 V). Furthermore, this work highlights the importance of post-heating treatment on the structural evolution and its role in exploring new halide-incorporated sulfide-type SEs, promoting the development of inorganic solid-state ionic conductors.

25 ENERGY STORAGE↗

A non-fueled nuclear-heated rod for in-pile transient boiling studies

Separate-effects boiling experiments have recently been conducted in the Transient Reactor Test Facility at Idaho National Laboratory to investigate transient heating and irradiation effects on cladding-to-coolant heat transfer. Specifically, transient critical heat flux (CHF) remains an important area of research, and better understanding of this phenomenon has potential for improving predictive models related to operational and safety limits. Consequently, this knowledge is expected to improve efficiency of light-water reactor operations. A novel borated nuclear-heated rodlet (BNHR) was designed to enable observation of transient cladding-to-coolant heat transfer phenomena. The final BNHR design takes a surrogate approach, wherein nuclear heating is induced by 10 B(n, α) reactions rather than derived from fissions in a fueled specimen. The structure of the BNHR consists of a hollowed out borated (B nat ~ 2.05 wt %) stainless steel tube with an hourglass-shaped outer surface, capped at both ends with non-borated stainless steel. This geometry allows for inner-rodlet instrumentation and generation of the highest nuclear heating rates near the center of the rodlet to ensure onset of boiling near instrumentation for real-time observation. A novel approach to measuring the nuclear energy deposition rate in the BNHR separate and apart from the influence of the coolant, termed the n-a thermometer, is also detailed in this paper. This device has demonstrated excellent repeatability, and measurements indicate predictive modeling results for energy deposition in the BNHR rod agree within a 10% margin of the experiment measurements. In conclusion, these results give confidence that the BNHR design has successfully met experiment objectives.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Residential segregation and outdoor urban moist heat stress disparities in the United States

The combined impact of urbanization-induced warming and drying on large-scale heat stress disparities remains unknown, with multicity studies using satellite-derived land surface temperature as a proxy for these disparities. Here, using high-resolution urban-resolving numerical model simulations for 2014–2018, we find pervasive disparities in all-sky average maximum summertime air temperature and moist heat stress metrics across US cities, with higher outdoor heat stress exposure in poorer and primarily non-white census tracts. Ninety-four percent of the US urban population (228 million) live in cities where heat stress burdens the poor, with heat stress inequities between white and non-white populations strongly associated with residential segregation. Similarly, historically redlined neighborhoods show higher heat stress than their non-redlined counterparts, demonstrating how historical segregation relates to present-day environmental inequalities. Our results provide quantitative estimates of physiologically relevant heat stress disparities at the US national scale and highlight potential biases when using satellites as a proxy for these.

54 ENVIRONMENTAL SCIENCES↗

A heat flux sensor leveraging the transverse Seebeck effect in elemental antimony

Certain configurations of anisotropic single crystal materials can generate a thermoelectric voltage orthogonal to an induced temperature gradient. This phenomenon is known as the Transverse Seebeck Effect (TSE) and can be leveraged to fabricate simple and robust heat flux sensors. Only a small number of materials have been considered as TSE-based transducers and, among these, few have been developed into sensors with ruggedization against chemical and mechanical degradation. Here, we report on the fabrication and characterization of a rugged TSE-based heat flux sensor using prismatic antimony single crystals. The heat flux sensor was tested under static and dynamic heating scenarios. The sensor has a linear responsivity of 16.8 µV/(W/cm2) to heat fluxes spanning more than two orders of magnitude and a time constant of 4.4 s. The sensor’s response to localized heating, probed with a laser scanning technique, validated that the transduction mechanism is primarily the TSE by ruling out a sizable contribution from the conventional Seebeck effect. Finite element analysis corroborated that components used in the sensor package are the primary determinants of the time constant and the decrement of the responsivity from its theoretical maximum. Design principles that may be applied to elicit a faster transient response or higher responsivity are proposed. Furthermore, the results establish single crystal antimony as a promising transducer material for heat flux measurement systems and demonstrate potential effects of ruggedization on sensor performance.

36 MATERIALS SCIENCE↗

Utilizing waste heat in wastewater treatment plants for water desalination: Modeling and Multi-Objective optimization of a Multi-Effect desalination system using Decision Tree Regression and Pelican optimization algorithm

This paper examines the feasibility of using waste heat from wastewater treatment plants (WWTPs) for water desalination. A model was developed to utilize waste heat from the gensets at As Samra WWTP in Jordan, using real data and TRNSYS® software to calculate available waste heat. The desalination process was then modeled with ASPEN PLUS® software, focusing on multi-effect desalination (MED). Both series and parallel configurations for the MED system were compared. The study investigated the effects of system feeding flow rate, feeding pressure, and heat input on productivity, performance ratio, and recovery ratio. The study also introduces a novel optimization technique combining machine learning and modern optimization algorithms to maximize system productivity and performance. Initially, a decision tree regression (DTR) model is developed to establish relationships between key independent variables (flow rate, feed pressure, and heat input) and dependent variables (productivity, performance ratio, and recovery ratio). The Pelican Optimization Algorithm (POA) is then used to identify the optimal values of the independent variables for maximum productivity and performance. The results show that using a series configuration yields a system productivity of 3984.2 kg/hr, a performance ratio of 3.78, and a recovery ratio of 0.991 at a feed flow rate of 4000 kg/hr, feed pressure of 3 bars, and heat input of 719 kW. Optimal productivity (4421 kg/hr), performance ratio (3.81), and recovery ratio (0.851) are achieved at a feed flow rate of 5166 kg/hr, feed pressure of 3.2 bars, and heat input of 794 kW. In conclusion, the techno-economic assessment indicates a levelized cost of water of 1.63 USD/m 3 for parallel configurations and 1.65 USD/m 3 for series configurations, with a payback period of less than two years.

42 ENGINEERING↗

Urban Versus Lake Impacts on Heat Stress and Its Disparities in a Shoreline City

Abstract Shoreline cities are influenced by both urban‐scale processes and land‐water interactions, with consequences on heat exposure and its disparities. Heat exposure studies over these cities have focused on air and skin temperature, even though moisture advection from water bodies can also modulate heat stress. Here, using an ensemble of model simulations covering Chicago, we find that Lake Michigan strongly reduces heat exposure (2.75°C reduction in maximum average air temperature in Chicago) and heat stress (maximum average wet bulb globe temperature reduced by 0.86°C) during the day, while urbanization enhances them at night (2.75 and 1.57°C increases in minimum average air and wet bulb globe temperature, respectively). We also demonstrate that urban and lake impacts on temperature (particularly skin temperature), including their extremes, and lake‐to‐land gradients, are stronger than the corresponding impacts on heat stress, partly due to humidity‐related feedback. Likewise, environmental disparities across community areas in Chicago seen for skin temperature are much higher (1.29°C increase for maximum average values per $10,000 higher median income per capita) than disparities in air temperature (0.50°C increase) and wet bulb globe temperature (0.23°C increase). The results call for consistent use of physiologically relevant heat exposure metrics to accurately capture the public health implications of urbanization.

54 ENVIRONMENTAL SCIENCES↗

Structural Uncertainty in the Sensitivity of Urban Temperatures to Anthropogenic Heat Flux

One key source of uncertainty for weather and climate models is structural uncertainty arising from the fact that these models must simplify or approximate complex physical, chemical, and biological processes that occur in the real world. However, structural uncertainty is rarely examined in the context of simulated effects of anthropogenic heat flux in cities. Using the Weather Research and Forecasting (WRF) model coupled with a single-layer urban canopy model, it is found that the sensitivity of urban canopy air temperature to anthropogenic heat flux can differ by an order of magnitude depending on how anthropogenic heat flux is released to the urban environment. Moreover, varying model structures through changing the treatment of roof-air interaction and the parameterization of convective heat transfer between the canopy air and the atmosphere can affect the sensitivity of urban canopy air temperature by a factor of 4. Urban surface temperature and 2-m air temperature are less sensitive to the methods of anthropogenic heat flux release and the examined model structural variants than urban canopy air temperature, but their sensitivities to anthropogenic heat flux can still vary by as much as a factor of 4 for surface temperature and 2 for 2-m air temperature. Our study recommends using temperature sensitivity instead of temperature response to understand how various physical processes (and their representations in numerical models) modulate the simulated effects of anthropogenic heat flux.

54 ENVIRONMENTAL SCIENCES↗

Effect of heat treatments on superconducting properties and connectivity in K-doped BaFe2As2

Abstract Fe-based superconductors and in particular K-doped BaFe 2 As 2 (K-Ba122) are materials of interest for possible future high-field applications. However the critical current density ( J c ) in polycrystalline Ba122 is still quite low and connectivity issues are suspected to be responsible. In this work we investigated the properties of high-purity, carefully processed, K-Ba122 samples synthesized with two separate heat treatments at various temperatures between 600 and 825 °C. We performed specific heat characterization and T c -distribution analysis up to 16 T and we compared them with magnetic T c and J c characterizations, and transmission-electron-microscopy (TEM) microstructures. We found no direct correlation between the magnetic T c and J c , whereas the specific heat T c -distributions did provide valuable insights. In fact the best J c -performing sample, heat treated first at 750 °C and then at 600 °C, has the peak of the T c -distributions at the highest temperatures and the least field sensitivity, thus maximizing H c2 . We also observed that the magnetic T c onset was always significantly lower than the specific heat T c : although we partially ascribe the lower magnetization T c to the small grain size (< λ , the penetration depth) of the K-Ba122 phase, this behaviour also implies the presence of some grain-boundary barriers to current flow. Comparing the T c -distribution with J c , our systematic synthesis study reveals that increasing the first heat treatment above 750 °C or the second one above 600 °C significantly compromises the connectivity and suppresses the vortex pinning properties. We conclude that high-purity precursors and clean processing are not yet enough to overcome all J c limitations. However, our study suggests that a higher temperature T c -distribution, a larger H c2 and a better connectivity could be achieved by lowering the second heat treatment temperature below 600 °C thus enhancing, as a consequence, J c .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The selective heating effect of microwave irradiation on a binary mixture of water and polyethylene oxide: a molecular dynamics simulation approach

In this study, we investigate the molecular mechanisms of a microwave-driven selective heating process by performing molecular dynamics simulations for three different systems including pure water, pure polyethylene oxide (PEO), and water-PEO mixed systems in the presence of a microwave with two different intensities of electric field such as 0.001 V/Å -1 and 0.01 V/Å -1 at a frequency of 100 GHz. First, from performing molecular dynamics simulations of CO and CO 2 in the presence of the microwave, it is confirmed that the molecular dipole moment is responsible for the rotational motion induced by the oscillating electric field. Second, by analyzing the MD simulations of the pure water system, we discover that the dipole moment of water exhibits a time lag with respect to the microwave. During the heating process, however, the temperature, kinetic, and potential energies increase synchronously with the oscillating electric field of the microwave, showing that the heating of the water system is caused by the molecular reaction of water to the microwave. Comparing the water-PEO mixed system to the pure water and pure PEO systems, the water-PEO mixed system has a higher heating rate than the pure PEO system but a lower heating rate than the pure water system. Therefore, we conclude that heating the water-PEO mixed system is driven by water molecules selectively activated by microwave irradiation. Furthermore, we also calculate the diffusion coefficients of water molecules and PEO chains by describing their mean square displacements, demonstrating that the diffusion coefficients are increased in the presence of microwaves for both water and PEO in pure and mixed systems. Lastly, during the microwave heating process, the structures of the water-PEO mixed system are altered as a function of the intensity of electric field, which is mainly driven by the response of water molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of edge harmonic oscillations on the divertor heat flux in NSTX

Previously, ELM-free and inter-ELM divertor peak heat flux reduction induced by an edge harmonic oscillation (EHO) was observed in NSTX (K.F. Gan et al., 2017 Nucl. Fusion 57 126053). This paper introduces new analysis of the EHO impact on the divertor heat flux. It was found that enhanced edge turbulence significantly altered the divertor heat flux footprint in NSTX H-modes, relative to ELM-free discharges. When the background edge fluctuation level was low, the EHO significantly increased the heat flux width and decreased the divertor peak heat flux. When the background edge fluctuation level was high, the EHO actually increased the divertor peak heat flux. As a result, it was also found that the heat flux width increased with increasing frequency of the EHO.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗