Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Contributions of Astronauts Aerobic Exercise Intensity and Time on Change in VO2peak during Spaceflight

There is considerable variability among astronauts with respect to changes in maximal aerobic capacity (VO2peak) during International Space Station (ISS) missions, ranging from a 5% increase to 30% decline. Individual differences may be due to in-flight aerobic exercise time and intensity. PURPOSE: To evaluate the effects of in-flight aerobic exercise time and intensity on change in VO2peak during ISS missions. METHODS: Astronauts (N=11) performed peak cycle tests approx 60 days before flight (L-60), on flight day (FD) approx 14, and every approx 30 days thereafter. Metabolic gas analysis and heart rate (HR) were measured continuously during the test using the portable pulmonary function system. HR and duration of each in-flight cycle ergometer and treadmill (TM) session were recorded and averaged in time segments corresponding to each peak test. Mixed effects linear regression with exercise mode (TM or cycle) as a categorical variable was used to assess the contributions of exercise intensity (%time >70% peak HR or %time >90% peak HR) and time (min/wk), adjusted for body weight, on %change in VO2peak during the mission, and incorporating the repeated-measures experimental design. RESULTS: 110 observations were included in the model (4-6 peak cycle tests per astronaut, 2 exercise devices). VO2peak was reduced from preflight throughout the mission (FD14: 13+/-13% and FD 105: 8+/-10%). Exercise intensity (%peak HR: FD14=66+/-14; FD105=75+/-8) and time (min/wk: FD14=82+/-46; FD105=158+/-40) increased during flight. The models showed main effects for exercise time and intensity with no interactions between time, intensity, and device (70% peak HR: time [z-score=2.39; P=0.017], intensity [z-score=3.51; P=0.000]; 90% peak HR: time [zscore= 3.31; P=0.001], intensity [z-score=2.24; P=0.025]). CONCLUSION: Exercise time and intensity independently contribute to %change in VO2peak during ISS missions, indicating that there are minimal values for exercise time and intensity required to maintain VO2peak. As the FD105 average exercise intensity and time did not prevent a decline in VO2peak from preflight, astronauts' exercise prescriptions should target at least 160 min of weekly aerobic exercise at an average above 75% peak HR with increased time at intensities above 90% of peak HR starting early in the mission.

Downs, Meghan E.↗

Evaluation of the Danish Aerospace Corporation Portable Pulmonary Function System

A research project designed to investigate changes in maximal oxygen consumption (VO2max) during and following long duration flight on the International Space Station (ISS) has recently been completed. The device used to measure VO2 on board ISS, the Portable Pulmonary Function System (PPFS) manufactured by the Danish Aerospace Corporation (DAC), is based on previous-generation devices manufactured by DAC, but the PPFS has not been validated for analyzing metabolic gases or measuring cardiac output (Qc). The purpose of the present evaluation is to compare PPFS metabolic gas analysis measurements to measurements obtained using a clinically-validated system (ParvoMedics TrueOne(c) 2400 system; Parvo). In addition, Qc data collected with the PPFS were compared to Qc measurements from echocardiography. METHODS: Ten subjects completed three cycle exercise tests to maximal exertion. The first test was conducted to determine each subject's VO2max and set the work rates for the second and third (comparison) tests. The protocol for the two comparison tests consisted of three 5-minute stages designed to elicit 25%, 50%, and 75% VO2max (based upon results from the initial test), followed by 1-minute stages of increasing work rate (25 watt/minute) until the subject reached maximal effort. During one of the two comparison tests, metabolic gases and Qc were assessed with the PPFS; metabolic gases and Qc were assessed with the Parvo and by echocardiography, respectively, during the other test. The order of the comparison tests was counterbalanced. VO2max and maximal work rate during the comparison tests were compared using t tests. Mixed-effects regression modeling was used to analyze submaximal data. RESULTS: All of the data were within normal physiological ranges. The PPFS-measured values for VO2max were 6% lower than values obtained with the Parvo (PPFS: 3.11 +/- 0.75 L/min; Parvo: 3.32 +/- 0.87 L/min; mean +/- standard deviation; P = 0.02); this difference is probably due to flow restriction imposed by the PPFS Qc accessories. Submaximal VO2 values were slightly lower when measured with the PPFS, although differences were not physiologically relevant. The PPFS-measured values of submaximal carbon dioxide production (VCO2) were lower than the data obtained from Parvo, which could be attributed to lower fractions of expired carbon dioxide measured by the PPFS. The PPFS Qc values tended to be lower than echocardiography-derived values. CONCLUSIONS: The results of the present study indicate a need to further examine the PPFS and to better quantify its reproducibility; however, none of the findings of the current evaluation indicate that the PPFS needs to be replaced or modified.

Portable Pulmonary Function System (PPFS)↗

Mars Ecopoiesis Testbed

Mars surface conditions where liquid water is absent were simulated for the purposes of laboratory research. A pressure-temperature (P-T) profile was maintained in which no combination of pressure or temperature corresponds to the liquid region of the water phase diagram. The triple point of pure water occurs at T = 0.1oC and P(H2O) = 6.01 mbar; therefore all temperatures and pressures must be kept below these values, respectively. A 35-day test was performed in a commercial planetary simulation system (Techshot, Inc., Greenville, IN) in which the minimum night-time temperature was -80oC, the maximum daytime temperature was +26oC, the simulated day-night light cycle in earth hours was 12-on and 12-off, and the total pressure of the pure CO2 atmosphere was maintained below 11 mbar. Any water present was allowed to equilibrate with the changing temperature and pressure. The gas phase was sampled into a CR1-A condensation-mirror low-pressure hygrometer, which uses liquid nitrogen (down to 77oK) to determine the dew point (Buck Technologies, Boulder, CO). Dew point was measured once every hour and recorded on a data logger, along with the varying temperature in the chamber, from which the partial pressure of water was calculated. The resulting calculated daily cycles were tracked on the water P-T diagram, and no points were found to fall within the liquid-phase region of the diagram. It is concluded that there was no liquid water present throughout the test except during the initial pump-down period when aqueous specimens were introduced on the first day (less than 1 hour). Mars regolith simulant was present during this test, and further investigation is needed to determine whether liquid water could have been present or absent in the regolith in the form of brine. Biological samples consisting of Cyanobacteria: Anabena sp., Chroococcidiopsis CCMEE171, Plectonema boryanum; Eubacteria: Bacillus subtilis, Pseudomonas aeruginosa, and Eukaryota: Chlorella ellipsoidia were maintained in the simulator under the above-described conditions. The exposed specimens were tested for intracellular esterase activity, chlorophyll content (where appropriate) and reproductive survival. All tests yielded low-level positive results in all cases. In parallel to these terrestrial studies a planned design study was undertaken for the proposed test bed. Design requirements include compact assembly for transport and installation on the planetary surface (multiple units per mission would be expected), protective internal package for the release of organisms, a means of atmosphere exchange, access to sunlight, a means of penetrating the planetary surface, and most importantly a means of acquiring regolith while meeting the requirements of planetary protection. In consultation with advisers a design was created, and a large-scale mock-up of this design was fabricated by additive manufacturing at Techshot, Inc. with moving parts that simulated the components of the design. The mock-up assembly has been demonstrated to interested parties. A means of detecting live metabolism will also be included in the test bed. Several options were reviewed, and it is concluded that, by the time the ecopoiesis test bed is ready for testing the optimum instrument will be the equivalent of a hand-held mass spectrometer for metabolic gas analysis. This will maximize versatility and reveal much more information than could a detector of a single product (such as molecular oxygen), and the

Ecopoiesis↗

Detection of Siderite (FeCO3) in Glen Torridon Samples by the Mars Science Laboratory Rover

Siderite (FeCO3) has been detected in Gale Crater for the first time by the Mars Science Laboratory (MSL) Curiosity and is seen in multiple samples in the Glen Torridon (GT) region. The identification of siderite is based on evolved gas analysis (EGA) data from the Sample Analysis at Mars (SAM) instrument and X-ray diffraction (XRD) data from the Chemistry and Mineralogy (CheMin) instrument. Curiosity descended off of the Vera Rubin ridge (VRR) into the Glen Torridon region on Sol 2300. Glen Torridon is of particular interest because a strong clay mineral signature had been detected by orbital instruments [1]. To date, four drilled samples have been collected at two different drill locations: Kilmarie and Aberlady from adjacent blocks at the base of the south side of VRR in the Jura member and Glen Etive 1 and 2 on the same block in the Knockfarril member.

Archer, P. D.↗

Evidence for Adsorption of Chlorine Species on Iron(III) (hydr)oxides in the Sheepbed Mudstone, Gale Crater, Mars

Chlorine is a widespread element on Mars present in dust, soils and rocks, including the Sheepbed mudstone at Yellowknife Bay, Gale crater. Combined elemental and volatile analyses of two drilled samples, Cumberland and John Klein, indicated that chloride (Cl-) and perchlorate (ClO4 -) are likely present in the mudstone. The nature of chlorine species in Sheepbed mudstone is still not well constrained. It has been proposed that both are present as amorphous or crystalline salts physically mixed with mudstone minerals. We alternatively hypothesize that adsorbed perchlorate and chloride exist in the mudstone and adsorption could occur, in particular, on Fe(III) (hydr)oxide phases as supported by laboratory observations on terrestrial materials. Mineralogical and compositional analyses of the drilled Cumberland mudstone sample revealed the presence of ~30 wt% of a Fe-rich X-ray amorphous phase. Ferrihydrite has been proposed as a component of the Fe-rich X-ray amorphous material. The objectives of this work were to determine adsorption of perchlorate and chloride on ferrihydrite and to enable data comparison by characterizing adsorbed chloride and perchlorate with thermal and evolved gas analysis run under operating conditions similar to the SAM instrument onboard the Curiosity rover.

Peretyazhko, T. S.↗

Mass Spectra Deconvolution of Gaseous Mixtures Containing Volatile Organic Compounds

The Spacecraft Atmosphere Monitor (S.A.M.) analyzes all gaseous pollutants in the 1-150Th mass-to-charge range based on their positive-ion mass spectra. Of particular interest is the Trace Gas Analysis (TGA) mode of operation in which S.A.M detects minute amounts of volatile organic compounds (VOC). Pollutant component of the ambient air is sampled on demand in twenty full mass spectra per second. All spectra is accumulated in two-second intervals by an on-board Field Programmable Gate Arrays (FPGA) unit. Mass spectra represents the number of detected fragment ions in a given mass-to-charge ratio channel. Electron impact ionization of neutral molecules results in creation of numerous fragment ions and most of organic compounds will contribute several identical fragments. Despite the presence of these molecular isobars, we developed the deconvolution algorithm capable of identifying target species based on their characteristic fragmentation patterns. We investigate the efficiency of deconvolution algorithm as a function of mass resolution with which mass spectrum is acquired. Higher the mass resolution, better the chances are to distinguish between stereoisomers using their fragmentation propensities, but also results in higher data volumes to be processed by a set of small footprint software stacks hosted by an on-board computer. Finding the balance between deconvolution accuracy and generated data volume under time constrains and limited computing resources is the main topic of this study.

Darrach, M.↗

Dissolution Rates of Allophane with Variable Fe Contents: Implications for Aqueous Alteration and the Preservation of X-ray Amorphous Materials on Mars

Recent measurements from Mars document X-ray amorphous/nano-crystalline materials in multiple locations across the planet. However, despite their prevalence, little is known about these materials or what their presence implies for the history of Mars. The X-ray amorphous component of the martian soil in Gale crater has an X-ray diffraction pattern that can be partially fit with allophane (approximately Al2O3•(SiO2)1.3-2•(H2O)2.5-3), and the low-temperature water release data are consistent with allophane. The chemical data from Gale crater suggest that other silicate materials similar to allophane, such as Fe-substituted allophane (approximately (Fe2O3)0.01-0.5(Al2O3)0.5-0.99•(SiO2)2•3H2O), may also be present. In order to investigate the properties of these potential poorly crystalline components of the martian soil, Fe-free allophane (Fe:Al = 0), Fe-poor allophane (Fe:Al = 1:99), and Fe-rich allophane (Fe:Al = 1:1) were synthesized and then characterized using electron microscopy and Mars-relevant techniques, including infrared spectroscopy, X-ray diffraction, and evolved gas analysis. Dissolution experiments were performed at acidic (initial pH values pH0 = 3.01, pH0 = 5.04), near-neutral (pH0 = 6.99), and alkaline (pH0 = 10.4) conditions in order to determine dissolution kinetics and alteration phases for these poorly crystalline materials. Dissolution rates (rdiss), based on the rate of Si release into solution, show that these poorly crystalline materials dissolve approximately an order of magnitude faster than crystalline phases with similar compositions at all pH conditions. For Fe-free allophane, logrdiss = -10.65 – 0.15 × pH; for Fe-poor allophane, logrdiss = -10.35 – 0.22 × pH; and for Fe-rich allophane, logrdiss = -11.46 – 0.042 × pH at 25°C, where rdiss has the units of mol m-2 s-1. The formation of incipient phyllosilicate-like phases was detected in Fe-free and Fe-rich allophane reacted in aqueous solutions with pH0 = 10.4 (steady-state pH ≈ 8). Mars-analog instrument analyses demonstrate that Fe-free allophane, Fe-poor allophane, and Fe-rich allophane are appropriate analogs for silicate phases in the martian amorphous soil component. Therefore, similar materials on Mars must have had limited interaction with liquid water since their formation. Combined with chemical changes expected from weathering, such as phyllosilicate formation, the rapid alteration of these poorly crystalline materials may be a useful tool for evaluating the extent of aqueous alteration in returned samples of martian soils.

S J Ralston↗

Hydrogen Plasma Reduction of Silicates for Lunar Oxygen Liberation

As crewed missions to the moon become closer, the focus on in-situ resource utilization efforts has increased. Since lunar soil has abundant oxygen on the surface of the moon, work has been done to process this resource in an efficient manner. Hydrogen reduction of lunar regolith has emerged as a method of liberating oxygen that can be used for fuel and water production. Traditional reduction techniques require high temperatures and increased complexity when dealing with high amounts of silicates. Plasma can reduce silicates efficiently and thus has become of high interest for use in the lunar highlands where silicates exist in high quantities. NASA’s Kennedy Space Center is exploring the use of low temperature plasmas for the reduction of silicates. This work shows that exposing silicates to a hydrogen plasma produces water. Residual gas analysis and optical emission spectroscopy were used to measure the relative quantities of water vapor production and OH (A-X) emission for hydrogen plasma interactions with lunar highland simulant and silica. X-ray photo-electron spectroscopy and scanning electron microscopy/energy-dispersive X-ray spectroscopy were also used to observe surface modifications to the silicates that reflect the key chemical reactions that occurred. From this data, plasma has emerged as a promising solution to produce oxygen on the lunar surface. *Work supported by NASA's Science Technology Mission Directorate Center Innovation Fund.

R. P. Gott↗

Plasma Reduction of Regolith for Oxygen Liberation

As crewed missions to the moon become closer, the focus on in-situ resource utilization efforts has increased. Since lunar soil has abundant oxygen on the surface of the moon, work has been done to process this resource in an efficient manner. Hydrogen reduction of lunar regolith has emerged as a method of liberating oxygen that can be used for fuel and water production. Traditional reduction techniques require high temperatures and increased complexity when dealing with high amounts of silicates. Plasma can reduce silicates efficiently and thus has become of high interest for use in the lunar highlands where silicates exist in high quantities. NASA’s Kennedy Space Center is exploring the use of low temperature plasmas for the reduction of silicates. This work shows that exposing silicates to a hydrogen plasma produces water. Residual gas analysis and optical emission spectroscopy were used to measure the relative quantities of water vapor production and OH (A-X) emission for hydrogen plasma interactions with lunar highland simulant and silica. X-ray photo-electron spectroscopy and scanning electron microscopy/energy-dispersive X-ray spectroscopy were also used to observe surface modifications to the silicates that reflect the key chemical reactions that occurred. From this data, plasma has emerged as a promising solution to produce oxygen on the lunar surface.

Ryan Gott↗

The Chemistry and Mineralogy of Mars Soils: A Tour of Landed Mission Results from the Last 45 years

Eight landed missions demonstrated that martian soils (defined as loose, unconsolidated surface material) consist of basaltic mineralogy, iron (hydr)oxides, amorphous material, sulfate, chloride, (per)chlorate, nitrate, carbonate, and possible organic C. The Viking Lander 1 and 2 (1976), Mars Pathfinder (1997), and Mars Exploration Rover (MER-A,B) (2004) missions determined that martian soil was similar at all landing sites by having mafic chemistry, high S (~ 7 wt.% SO3) and Cl (0.7 wt.%), and spectral detections of poorly crystalline and crystalline Fe-(hydr)oxide phases. The MER Mössbauer spectrometers detected Fe-bearing olivine and pyroxene along with magnetite, nano-phase Fe-oxides (npOx), hematite, and ferric sulfate. The 2008 Phoenix Lander instrumentation measured a soil pH of 7.7 and detected ~0.6 wt.% perchlorate, 3-5 wt.% Ca-rich carbonate and carbon (500 gC/g) consistent with oxidized organics and Fe-rich carbonate. The 2012 Mars Science Laboratory (MSL) rover (Gale Crater) through X-ray diffraction detected plagioclase feldspar, pyroxene, magnetite, hematite, anhydrite, and quartz, with the balance being composed of Si/Fe-containing amorphous (30 to 40 wt.%) material. MSL evolved gas analysis detected (per)chlorate (0.4 wt.% ClO4), nitrate (0.23 wt.%), along with minor Fe/Mg sulfate and oxidized organic C (~2000 gC/g). Limited pedogenesis may have occurred at the 2018 InSight landing site and in one Gusev Crater soil (MER-B) which have 3 to 10 cm-thick duricrust horizons consistent with atmospheric water vapor interactions with soil salts. Martian soil primary mineralogy was derived mostly from local rock (volcanic, sedimentary) that is largely basaltic planet wide. Secondary minerals [e.g., sulfate, chloride, perchlorate, nitrate, carbonate, Fe-(hydr)oxides] in martian soils formed from oxidative aqueous alteration processes and were likely derived from a combination of local sedimentary rock sources and the global bright dust. The Mars 2020 mission will collect soil for Earth return to enable a thorough assessment of the nature and origin of martian soil.

Mars↗

IN-LINE CHEMICAL SENSOR DEPLOYMENT IN A TRITIUM PLANT

The Savannah River Tritium Plant (TP) relies on well understood but aging sensor technology for process gas analysis. Though new sensor technologies have been brought to various readiness levels, the TP has been reluctant to install technologies that have not been tested in tritium service. This gap between sensor technology development and incorporating new technologies into practical applications demonstrates fundamental challenges that exist when transitioning from status quo to state-of-the-art in an extreme environment such as a tritium plant. These challenges stem from three root obstacles: 1) The need for a comprehensive assessment of process sensing needs and requirements; 2) The lack of a pick-list of process-compatible sensor technologies; and 3) The need to test technologies in a tritium-contaminated process environment without risking production. At Savannah River, these issues are being addressed in a two phase project. In the first phase, TP sensing requirements were determined by a team of process experts. Meanwhile, Savannah River National Laboratory sensor experts identified candidate technologies and related them to the TP processing requirements. The resulting roadmap links the candidate technologies to actual plant needs. To provide accurate assessments of how a candidate sensor technology would perform in a contaminated process environment, an instrument demonstration station was established within a TP glove box. This station was fabricated to TP process requirements and designed to handle high activity samples. The combination of roadmap and demonstration station provides the following assets: Creates a partnership between the process engineers and researchers for sensor selection, maturation, and insertion, Selects the right sensors for process conditions Provides a means for safely inserting new sensor technology into the process without risking production, and Provides a means to evaluate off normal occurrences where and when they occur. This paper discusses the process to identify and demonstrate new sensor technologies for the Savannah River TP.

07 ISOTOPE AND RADIATION SOURCES↗

Korea's activities for the development of ITER tritium storage and delivery systems

The ITER fuel cycle plant is composed of various subsystems such as a long term tritium storage system (LTS), a fuel storage and delivery system (SDS), a tokamak exhaust processing system, a hydrogen isotope separation system, and a tritium plant analytical system. Korea shares in the construction of the ITER fuel cycle plant with the EU (Japan)) and US, and is responsible for the development and supply of the SDS and LTS. The authors thus present details on the development status of the tritium transport container, the long term tritium storage beds, the short-term delivery system T{sub 2}, DT, and the D{sub 2} storage beds, the calorimetry system, and the associated He-3 recovery loop, the over pressure protection systems, and the gas analysis manifold connected to the tritium plant's analytical systems. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Roles and Developments needed for Diagnostics in the ITER Fusion Device

Harnessing the power from Fusion on earth is an important and challenging task. Excellent work has been carried out in this area over the years with several demonstrations of the ability to produce power. Now, a new large device is being constructed in the south of France. This is called ITER. ITER is a large-scale scientific experiment that aims to demonstrate a possibility to produce commercial energy from fusion. This project is now well underway with the many teams working on the construction and completing various aspects of the design. This device will carry up to 15 MA of plasma current and produce about 500 MW of power, 400 MW approximately in high energy neutrons. The typical temperatures of the electrons inside this device are in the region of a few hundred million Kelvin. It is maintained using a magnetic field. This device is pushing several boundaries from those currently existing. As a result of this, several technologies need to be developed or extended. This is especially true for the systems or diagnostics that measure the performance and provide the control signals for this device. A diagnostic set will be installed on the ITER machine to provide the measurements necessary to control, evaluate and optimize plasma performance in ITER and to further the understanding of plasma physics. These include amongst others, measurements of the plasma shape, temperature, density, impurity concentration, and particle and energy confinement times. The system will comprise about 45 individual measuring systems drawn from the full range of modern plasma diagnostic techniques, including magnetics, lasers, X-rays, neutron cameras, impurity monitors, particle spectrometers, radiation bolometers, pressure and gas analysis, and optical fibres. These devices will have to be made to work in the new and challenging environment inside the vacuum vessel. These systems will have to cope with a range of phenomena that extend the current knowledge in the Fusion field. One amongst them is the parasitic effect of the neutrons on the while all the performing with great accuracy and precision. The levels of neutral particle flux, neutron flux and neutron fluence will be respectively about 5, 10 and 10,000 times higher than the harshest experienced in today's machines. The pulse length of the fusion reaction-or the amount of time the reaction is sustained-will be about 100 times longer. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of Indirect Quantification of 133mXe to Calibration of HPGe Detector

The INL Noble Gas Laboratory provides intercomparison samples for the noble gas analysis laboratories as part of the CTBTO PrepCom IMS. Xe-133m is one of the four relevant radionuclides in nuclear explosion monitoring. Without commercially available Xe-133m calibration standards laboratories must create and improve calibration methods. Improvements in calibration methods at the INL NGL benefit the CTBTO PrepCom through better certified values for Xe-133m intercomparison samples. Calibration of High Purity Germanium detectors for Xe-133m quantification is complicated by the coexistence of Xe-133 in samples under analysis. Xe-133 is typically produced in larger quantities, has higher gamma emission probabilities, and its gammas are detected more efficiently than Xe-133m. Xe-133m activity of samples can be indirectly inferred through the 133:133m activity ratio of a batch of material, and the Xe-133 counts in the assay of a small aliquot of the same material. This indirect quantification method can be leveraged to perform detector calibrations for quantification of Xe-133m. Calibrations can be performed by inferring the Xe-133m to certify the sample, and direct counting to determine detector efficiency. A comparison of method results will be shown.

133mXe↗

Fast Hyperspectral Imaging Using a Mid-Infrared Tunable External Cavity Quantum Cascade Laser

An active hyperspectral imaging system using an external cavity quantum cascade laser and a focal plane array acquiring images at 25 Hz from 985 cm-1 to 1075 cm-1 with a resolution of 0.3 cm 1 is demonstrated. The chemical imaging of gases is demonstrated in both static and dynamic cases. The system was also used to analyze liquid and solid samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of gas-phase condensation of nickel nanoparticles

Gas-phase condensation of 8000 nickel atoms is examined by molecular dynamics simulation with a tight-binding potential. A detailed study of the evolution of the system cooled at a constant rate from 1000 K to 77 K is presented. The results are used to identify four distinct stages of the evolution from a hot atomic gas to a few synthesized particles. An analysis of possible nanoparticle formation mechanisms suggests that cluster-cluster aggregation is the dominant one. The simulation shows that there two stages of cluster formation are of primary importance with regard to aggregation. At the first stage, spherical liquid clusters nucleate with uniform size distribution. The second stage is characterized by a distinct transition from uniform to bimodal size distribution due to aggregation of relatively large clusters. The particles obtained by gas-phase synthesis are analyzed by the CNA method [25]. It is found that most nanoparticles produced in the simulation have either icosahedral or mixed FCC/HCP structure.

36 MATERIALS SCIENCE↗

Analysis of natural gas bubble in NETL High Pressure Water Tunnel (HPWT) experiment and its application to natural seeps

Conference Presentation at the 9th International Symposium on Environmental Hydraulics. Analysis of natural gas bubbles under deep-ocean conditions, including hydrate armoring. Compares numerical simulations using the Texas A&M Oil spill / outfall Calculator (TAMOC) to data observed in the NETL High Pressure Water Tunnel. Also, presents simulations of natural seep bubbles in the oceans off the coast of Oregon with comparison to acoustic observations of natural gas seep flares.

Kim, Byungjin↗

Entropy Generation/Availability Energy Loss Analysis Inside MIT Gas Spring and "Two Space" Test Rigs

The results of the entropy generation and availability energy loss analysis under conditions of oscillating pressure and oscillating helium gas flow in two Massachusetts Institute of Technology (MIT) test rigs piston-cylinder and piston-cylinder-heat exchanger are presented. Two solution domains, the gas spring (single-space) in the piston-cylinder test rig and the gas spring + heat exchanger (two-space) in the piston-cylinder-heat exchanger test rig are of interest. Sage and CFD-ACE+ commercial numerical codes are used to obtain 1-D and 2-D computer models, respectively, of each of the two solution domains and to simulate the oscillating gas flow and heat transfer effects in these domains. Second law analysis is used to characterize the entropy generation and availability energy losses inside the two solution domains. Internal and external entropy generation and availability energy loss results predicted by Sage and CFD-ACE+ are compared. Thermodynamic loss analysis of simple systems such as the MIT test rigs are often useful to understand some important features of complex pattern forming processes in more complex systems like the Stirling engine. This study is aimed at improving numerical codes for the prediction of thermodynamic losses via the development of a loss post-processor. The incorporation of loss post-processors in Stirling engine numerical codes will facilitate Stirling engine performance optimization. Loss analysis using entropy-generation rates due to heat and fluid flow is a relatively new technique for assessing component performance. It offers a deep insight into the flow phenomena, allows a more exact calculation of losses than is possible with traditional means involving the application of loss correlations and provides an effective tool for improving component and overall system performance.

Ebiana, Asuquo B.↗