Effect of inlet temperature and pressure on emissions from a premixing gas turbine primary zone combustor
Experiments were conducted to determine the performance of a premixing prevaporizing gas turbine primary zone combustor design over a range of combustor inlet temperatures from 700 to 1000 K and a range of inlet pressures from 40 to 240 N/sq cm. The 1 meter long combustor could be operated at pressures up to and including 120 N/sq cm without autoignition in the premixing duct or flashback from the stabilized combustion zone. Autoignition occurred in the mixer tube at the 240 N/sq cm pressure level with an entrance temperature of 830 K and a mixer residence time of 4 msec. Measured NOx level, combustion inefficiency, and hydrocarbon emission index correlated well with adiabatic flame temperature. The NOx levels varied from approximately 0.2 to 2.0 g NO2/kg fuel at combustion inefficiencies from 4 to 0.04 percent, depending upon adiabatic flame temperature and pressure. Measured NOx levels were sensitive to pressure. Tests were made at equivalence ratios ranging from 0.35 to 0.65. The overall total pressure drop for the configuration varied slightly with reference velocity and equivalence ratio, but never exceeded 3 percent.