Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Anisotropic Fano resonance in the Weyl semimetal candidate LaAlSi

Topological Weyl semimetal (WSM) is a solid-state realization of chiral Weyl fermions, whose phonon behaviors provide in-depth knowledge of their electronic properties. In this work, anisotropic Fano resonance is observed in a type-II WSM candidate LaAlSi by polarized Raman spectroscopy. The asymmetric line shape occurs for the $B^2_1$ phonon mode of LaAlSi only for 488- and 532-nm laser excitations but not for 364-, 633-, and 785-nm excitations, suggesting the excitation selectivity. The asymmetry, frequency, and linewidth of the $B^2_1$ phonon mode, along with the spectral background, all show fourfold rotational symmetry as a function of the polarization angle in the polarized Raman spectra. While the shift of Raman frequency in a metal or semimetal is typically attributed to Kohn anomaly, here we show that the anisotropic frequency shift in LaAlSi cannot be explained by the effect of Kohn anomaly, but potentially by the anisotropic scattering background of Fano resonance. Origins of the excitation-energy dependence and anisotropic behavior of the Fano resonance are discussed by the first-principles calculated electronic band structure and phonon dispersion.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Human responses to upright tilt: a window on central autonomic integration

1. We examined interactions between haemodynamic and autonomic neural oscillations during passive upright tilt, to gain better insight into human autonomic regulatory mechanisms. 2. We recorded the electrocardiogram, finger photoplethysmographic arterial pressure, respiration and peroneal nerve muscle sympathetic activity in nine healthy young adults. Subjects breathed in time with a metronome at 12 breaths min-1 (0.2 Hz) for 5 min each, in supine, and 20, 40, 60, 70 and 80 deg head-up positions. We performed fast Fourier transform (and autoregressive) power spectral analyses and integrated low-frequency (0.05-0.15 Hz) and respiratory-frequency (0. 15-0.5 Hz) spectral powers. 3. Integrated areas of muscle sympathetic bursts and their low- and respiratory-frequency spectral powers increased directly and significantly with the tilt angle. The centre frequency of low-frequency sympathetic oscillations was constant before and during tilt. Sympathetic bursts occurred more commonly during expiration than inspiration at low tilt angles, but occurred equally in expiration and inspiration at high tilt angles. 4. Systolic and diastolic pressures and their low- and respiratory-frequency spectral powers increased, and R-R intervals and their respiratory-frequency spectral power decreased progressively with the tilt angle. Low-frequency R-R interval spectral power did not change. 5. The cross-spectral phase angle between systolic pressures and R-R intervals remained constant and consistently negative at the low frequency, but shifted progressively from positive to negative at the respiratory frequency during tilt. The arterial baroreflex modulus, calculated from low-frequency cross-spectra, decreased at high tilt angles. 6. Our results document changes of baroreflex responses during upright tilt, which may reflect leftward movement of subjects on their arterial pressure sympathetic and vagal response relations. The intensity, but not the centre frequency of low-frequency cardiovascular rhythms, is modulated by the level of arterial baroreceptor input. Tilt reduces respiratory gating of sympathetic and vagal motoneurone responsiveness to stimulatory inputs for different reasons; during tilt, sympathetic stimulation increases to a level that overwhelms the respiratory gate, and vagal stimulation decreases to a level below that necessary for maximal respiratory gating to occur.

Non-NASA Center↗

Analytic and numerical vibronic spectra from quasi-classical trajectory ensembles

The truncated Wigner approximation to quantum dynamics in phase space is explored in the context of computing vibronic line shapes for monomer linear optical spectra. We consider multiple model potential forms including a shifted harmonic oscillator with both equal and unequal frequencies on the ground and excited state potentials as well as a shifted Morse potential model. For the equal-frequency shifted harmonic oscillator model, we derive an analytic expression for the exact vibronic line shape that emphasizes the importance of using a quantum mechanical distribution of phase space initial conditions. For the unequal-frequency shifted harmonic oscillator model, we are no longer able to obtain an exact expression for the vibronic line shape in terms of independent deterministic classical trajectories. We show how one can rigorously account for corrections to the truncated Wigner approximation through nonlinear responses of the line shape function to momentum fluctuations along a classical trajectory and demonstrate the qualitative improvement in the resulting spectrum when the leading-order quantum correction is included. Finally, we numerically simulate absorption spectra of a highly anharmonic shifted Morse potential model. We find that, while finite quantization and the dissociation limit are captured with reasonable accuracy, there is a qualitative breakdown of the quasi-classical trajectory ensemble’s ability to describe the vibronic line shape when the relative shift in Morse potentials becomes large. The work presented here provides clarity on the origin of unphysical negative features known to contaminate absorption spectra computed with quasi-classical trajectory ensembles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gyrating ions and large-amplitude monochromatic MHD waves upstream of the earth's bow shock

Episodes of nearly monochromatic, low-frequency (0.03 Hz) hydromagnetic waves are occasionally observed upstream of the earth's bow shock. High time resolution (3 s) measurements of two-dimensional ion distributions during two nearly monochromatic wave events reveal that the ion distributions asociated with these waves are 'gyrating ions.' Such distributions consists of suprathermal ions with parallel and perpendicular velocities confined to a fairly narrow range of (nonzero) values. The ions are also often confined to a fairly narrow range of gyrophase angle ('gyrophase bunched'). In one of the two cases, the observed frequency of the waves agrees quite well with the Doppler shifted resonance frequency of waves in right-hand resonance with the observed gyrating ions. In the second case, the observed frequency is lower than the predicted frequency by a factor of 1.5-2.

Thomsen, M. F.↗

Spectral induced polarization monitoring of induced calcite precipitation in subsurface sediments

Co-precipitation of contaminants within the crystalline structure of calcite is a promising natural attenuation or remedial technology being considered at contaminated sites. We explore the sensitivity of the spectral induced polarization (SIP) method to induced calcite precipitation in natural sediments as a path forward to non-invasively monitor these sites. We performed time-lapse column experiments using phased (I-IV) injections over 40 days on natural sediments from the Hanford Site (Washington State, USA). In the phased injections, abiotic calcite precipitation was induced and confirmed to have occurred. Previous work in glass beads and homogeneous sand was limited to high frequency detection of calcite, however in this work we observed the development of two polarization mechanisms, one at high frequency (>100 Hz) and one at low frequency (< 100 Hz). Based on the characteristic frequencies from the SIP high and low frequency regimes, characteristic length scales (L) were computed where the adsorption mode of Na+ versus Ca2+ was compared by using diffusion coefficients corresponding to Na+ versus an arithmetically averaged value for Na+ and Ca2+. Using the diffusion coefficient of Na+, the high frequency L was found to correlate well with the size of the calcite crystals. The low frequency L correlated well with the individual natural sediment grain sizes within the columns. During late experimental times (day 36 and 40), the characteristic low frequency in two of the experimental columns shifted to lower frequencies (<0.001 Hz) which may signify SIP sensitivity of the formed calcite with the sediment grains. In field applications, the development of a low frequency polarization length scale to monitor calcite precipitation is promising for field monitoring applications, however further laboratory work needs to be performed to examine the SIP sensitivity of calcite formation in the presence of to natural sediments

calcium carbonate, calcite, precipitation, spectra↗

Design of Microwave Resonant Cavity Transducer. Development of sensor performance model of microwave cavity flow meter for advanced reactor high temperature fluids

High-temperature fluid reactors, such as molten salt cooled reactors (MSCR) and sodium fast reactors (SFR), are a promising advanced reactor option. Measurement of high-temperature fluid process variables, in particular the flow inside the pressure vessel, is a challenging task because of harsh environment, which includes high radiation, high temperature, and contact with highly corrosive coolant fluid. We are investigating a microwave cavity-based transducer for high-temperature fluid flow sensing. This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. A cavity is characterized by its resonant frequencies. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the flow sensor is evaluated with signal sensitivity using COMSOL computer simulations. A right cylinder geometry stainless steel cavity with dimeter of 0.8in was investigated. We choose membrane thickness of 10mil, so that corrosion anticipated to proceed at the rate of 1mil/year in liquid sodium would affect no more than 10% of the membrane. Using the properties of liquid sodium fluid, and stainless-steel material property values at 500oC, we calculate frequency shift for a range of values of fluid velocity from 0.5m/s to 2m/s. Results of computer simulations indicate measurable sensitivity to flow for this cavity design. Following these simulations, we have developed a preliminary design for fabrication of a transducer operating in microwave K-band for proof-of-principle tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tensor-to-scalar ratio forecasts for extended LiteBIRD frequency configurations

LiteBIRD is a planned JAXA-led cosmic microwave background (CMB) B-mode satellite experiment aiming for launch in the late 2020s, with a primary goal of detecting the imprint of primordial inflationary gravitational waves. Its current baseline focal-plane configuration includes 15 frequency bands between 40 and 402 GHz, fulfilling the mission requirements to detect the amplitude of gravitational waves with the total uncertainty on the tensor-to-scalar ratio, δr, down to δr < 0.001. A key aspect of this performance is accurate astrophysical component separation, and the ability to remove polarized thermal dust emission is particularly important. In this paper we note that the CMB frequency spectrum falls off nearly exponentially above 300 GHz relative to the thermal dust spectral energy distribution, and a relatively minor high frequency extension can therefore result in even lower uncertainties and better model reconstructions. Specifically, we compared the baseline design with five extended configurations, while varying the underlying dust modeling, in each of which the High-Frequency Telescope (HFT) frequency range was shifted logarithmically toward higher frequencies, with an upper cutoff ranging between 400 and 600 GHz. In each case, we measured the tensor-to-scalar ratio r uncertainty and bias using both parametric and minimum-variance component-separation algorithms. When the thermal dust sky model includes a spatially varying spectral index and temperature, we find that the statistical uncertainty on r after foreground cleaning may be reduced by as much as 30–50% by extending the upper limit of the frequency range from 400 to 600 GHz, with most of the improvement already gained at 500 GHz. We also note that a broader frequency range leads to higher residuals when fitting an incorrect dust model, but also it is easier to discriminate between models through higher χ 2 sensitivity. Even in the case in which the fitting procedure does not correspond to the underlying dust model in the sky, and when the highest frequency data cannot be modeled with sufficient fidelity and must be excluded from the analysis, the uncertainty on r increases by only about 5% for a 500 GHz configuration compared to the baseline.

79 ASTRONOMY AND ASTROPHYSICS↗

Cement sensors with acoustic bandgaps using carbon nanotubes

Cement is widely used in wellbores to stabilize the steel casing used in wellbore operations for oil and gas production, enhanced geothermal systems and carbon sequestration, and to limit fluid movement between sub-surface strata. Flaws such as microcracks in wellbore cement can lead to leakage along the wellbore compromising wellbore integrity. There is an increasing need for methods to monitor cement crack propagation in wellbore environments. In this study, we develop and report the first cementitious sensors capable of exhibiting high frequency acoustic bandgaps (ABGs) using carbon nanotubes (CNTs). Computational simulations of a sensor unit cell are used to design cement-multi walled carbon nanotubes (MWCNTs) sensors that show a wide bandgap. When the cement-MWCNTs sensors is embedded in cement specimens, bandgaps were measured experimentally under 300 kHz and under 600 kHz, consistent with the computationally predicted bandgaps in the range of 290–360 kHz, 410–460 kHz and 515–585 kHz. These bandgap features were absent in homogeneous cement specimens. X-ray tomographic reconstructions showed microscopic debonding at cement-MWCNTs sensor interface. Frequency response analysis of a three-dimensional computational model indicated a shift of frequency of minimum transmission due to the interface debonding, but no perturbation of bandgap response was observed. Here, the cement-MWCNTs sensors developed in this study show the potential of a packed CNT inclusion material in cementitious matrix to create ABGs in a cement matrix.

36 MATERIALS SCIENCE↗

Nonlinear propagation of a wave packet in a two-dimensional acoustically lined duct

The method of multiple scales is used to analyze the nonlinear effects of the gas motion and the acoustic lining material on the propagation and attenuation of a wave packet in a two-dimensional duct of uniform cross section. The partial differential equations describing the space and time variation of amplitudes and phases are obtained and used to show that both the monochromatic waves and the pure amplitude modulated waves are stable. The spatial attenuation of the pure amplitude modulated waves is found to be lower than that of monochromatic waves, while the temporal attenuation of the former waves has a minimum value near the resonant frequency. The nonlinearity shifts the wavenumber and frequency to higher values without changing phase speed for the pure phase modulated waves.

Tsai, M.-S.↗

TlCaBaCuO high Tc superconducting microstrip ring resonators designed for 12 GHz

Microwave properties of sputtered Tl-Ca-Ba-Cu-O thin films were investigated by designing, fabricating, and testing microstrip ring resonators. Ring resonators designed for 12 GHz fundamental resonance frequency, were fabricated and tested. From the unloaded Q values for the resonators, the surface resistance was calculated by separating the conductor losses from the total losses. The penetration depth was obtained from the temperature dependence of resonance frequency, assuming that the shift in resonance frequency is mainly due to the temperature dependence of penetration depth. The effective surface resistance at 12 GHz and 77 K was determined to be between 1.5 and 2.75 mOmega, almost an order lower than Cu at the same temperature and frequency. The effective penetration depth at 0 K is approximately 7000 A.

Subramanyam, G.↗

Segmented Liner to Control Mode Scattering

The acoustic performance of duct liners can be improved by segmenting the treatment. In a segmented liner treatment, one stage of liner reduces the target sound and scatters energy into other acoustic modes, which are attenuated by a subsequent stage. The Curved Duct Test Rig is an experimental facility in which sound incident on the liner can be generated in a specific mode and the scatter of energy into other modes can be quantified. A series of experiments is performed in which the baseline configuration is asymmetric, that is, a liner is on one side wall of the test duct and the wall opposite is acoustically hard. Segmented liner treatment is achieved by progressively replacing sections of the hard wall opposite with liner in the axial direction, from 25% of the wall surface to 100%. It is found that the energy scatter from the (0,0) to the (0,1) mode reduces as the percentage of opposite wall treatment increases, and the frequency of peak attenuation shifts toward higher frequency. Similar results are found when the incident mode is of order (0,1) and scatter is into the (0,0) mode. The propagation code CDUCT-LaRC is used to predict the effect of liner segmenting on liner performance. The computational results show energy scatter and the effect of liner segmentation that agrees with the experimental results. The experiments and computations both show that segmenting the liner treatment is effective to control the scatter of incident mode energy into other modes. CDUCT-LaRC is shown to be a valuable tool to predict trends of liner performance with liner configuration.

Gerhold, Carl H.↗

Reconfigurable Wideband Circularly Polarized Stacked Square Patch Antenna for Cognitive Radios

An almost square patch, a square patch and a stacked square patch with corner truncation for circular polarization (CP) are researched and developed at X-band for cognitive radios. Experimental results indicate, first, that the impedance bandwidth of a CP almost square patch fed from the edge by a 50 ohm line is 1.70% and second, that of a CP square patch fed from the ground plane side by a surface launch connector is 1.87%. Third, the impedance bandwidth of a CP stacked square patch fed by a surface launch connector is 2.22%. The measured center frequency for the CP square patch fed by a surface launch connector without and with an identical stacked patch is 8.45 and 8.1017 GHz, respectively. By stacking a patch, separated by a fixed air gap of 0.254 mm, the center frequency is observed to shift by as much as 348.3 MHz. The shift in center frequency, brought about by the reconfiguring of the physical layer antenna, can be exploited in a cognitive system since it expands the usable frequency spectrum for software reconfiguration in the presence of interference. In addition, varying the fixed air gap in the stacked antenna geometry by increments of 0.254 mm further expands the usable frequency spectrum.

Cognitive↗

Tensor-to-scalar ratio forecasts for extended LiteBIRD frequency configurations

LiteBIRD is a planned JAXA-led cosmic microwave background (CMB) B -mode satellite experiment aiming for launch in the late 2020s, with a primary goal of detecting the imprint of primordial inflationary gravitational waves. Its current baseline focal-plane configuration includes 15 frequency bands between 40 and 402 GHz, fulfilling the mission requirements to detect the amplitude of gravitational waves with the total uncertainty on the tensor-to-scalar ratio, δr , down to δr < 0.001. A key aspect of this performance is accurate astrophysical component separation, and the ability to remove polarized thermal dust emission is particularly important. In this paper we note that the CMB frequency spectrum falls off nearly exponentially above 300 GHz relative to the thermal dust spectral energy distribution, and a relatively minor high frequency extension can therefore result in even lower uncertainties and better model reconstructions. Specifically, we compared the baseline design with five extended configurations, while varying the underlying dust modeling, in each of which the High-Frequency Telescope (HFT) frequency range was shifted logarithmically toward higher frequencies, with an upper cutoff ranging between 400 and 600 GHz. In each case, we measured the tensor-to-scalar ratio r uncertainty and bias using both parametric and minimum-variance component-separation algorithms. When the thermal dust sky model includes a spatially varying spectral index and temperature, we find that the statistical uncertainty on r after foreground cleaning may be reduced by as much as 30–50% by extending the upper limit of the frequency range from 400 to 600 GHz, with most of the improvement already gained at 500 GHz. We also note that a broader frequency range leads to higher residuals when fitting an incorrect dust model, but also it is easier to discriminate between models through higher χ 2 sensitivity. Even in the case in which the fitting procedure does not correspond to the underlying dust model in the sky, and when the highest frequency data cannot be modeled with sufficient fidelity and must be excluded from the analysis, the uncertainty on r increases by only about 5% for a 500 GHz configuration compared to the baseline.

U. Fuskeland↗

Overview of on-line data processing for MST radars (keynote paper), part 7

The most important aspects of the processing of MST radar data are discussed. The important points of on-line data processing for MST radar are reviewed. The goals of the on-line and now almost exclusively digital processing, procedures are to achieve good altitude resolution and coverage, good frequency (Doppler shift) resolution, and good time resolution, while avoiding, the problems of range and frequency ambiguity (aliasing), ground clutter, and interference. Achieving optimum results requires pulse compression and some coherent integration. The first allows full utilization of the average power capability of the transmitter and the second reduces the computing requirements.

Farley, D. T.↗

Center of Mass Estimation for a Spinning Spacecraft Using Doppler Shift of the GPS Carrier Frequency

A sequential filter is presented for estimating the center of mass (CM) of a spinning spacecraft using Doppler shift data from a set of onboard Global Positioning System (GPS) receivers. The advantage of the proposed method is that it is passive and can be run continuously in the background without using commanded thruster firings to excite spacecraft dynamical motion for observability. The NASA Magnetospheric Multiscale (MMS) mission is used as a test case for the CM estimator. The four MMS spacecraft carry star cameras for accurate attitude and spin rate estimation. The angle between the spacecraft nominal spin axis (for MMS this is the geometric body Z-axis) and the major principal axis of inertia is called the coning angle. The transverse components of the estimated rate provide a direct measure of the coning angle. The coning angle has been seen to shift slightly after every orbit and attitude maneuver. This change is attributed to a small asymmetry in the fuel distribution that changes with each burn. This paper shows a correlation between the apparent mass asymmetry deduced from the variations in the coning angle and the CM estimates made using the GPS Doppler data. The consistency between the changes in the coning angle and the CM provides validation of the proposed GPS Doppler method for estimation of the CM on spinning spacecraft.

Spacecraft↗

Center of Mass Estimation for a Spinning Spacecraft Using Doppler Shift of the GPS Carrier Frequency

A sequential filter is presented for estimating the center of mass (CM) of a spinning spacecraft using Doppler shift data from a set of onboard Global Positioning System (GPS) receivers. The advantage of the proposed method is that it is passive and can be run continuously in the background without using commanded thruster firings to excite spacecraft dynamical motion for observability. The NASA Magnetospheric Multiscale (MMS) mission is used as a test case for the CM estimator. The four MMS spacecraft carry star cameras for accurate attitude and spin rate estimation. The angle between the spacecraft nominal spin axis (for MMS this is the geometric body Z-axis) and the major principal axis of inertia is called the coning angle. The transverse components of the estimated rate provide a direct measure of the coning angle. The coning angle has been seen to shift slightly after every orbit and attitude maneuver. This change is attributed to a small asymmetry in the fuel distribution that changes with each burn. This paper shows a correlation between the apparent mass asymmetry deduced from the variations in the coning angle and the CM estimates made using the GPS Doppler data. The consistency between the changes in the coning angle and the CM provides validation of the proposed GPS Doppler method for estimation of the CM on spinning spacecraft.

Estimation↗

Frequency up-conversion of a high-power microwave pulse propagating in a self-generated plasma

In the study of the propagation of a high-power microwave pulse, one of the main concerns is how to minimize the energy loss of the pulse before reaching the destination. A frequency autoconversion process that can lead to reflectionless propagation of powerful electromagnetic pulses in self-generated plasmas is studied. The theory shows that, under the proper condition, the carrier frequency omega of the pulse shifts upward during the growth of local plasma frequency omega(pe). Thus, the self-generated plasma remains underdense to the pulse. A chamber experiment to demonstrate the frequency autoconversion during the pulse propagation through the self-generated plasma is conducted. The detected frequency shift is compared with the theoretical result calculated by using the measured electron density distribution along the propagation path of the pulse. Good agreement is obtained.

Kuo, S. P.↗