Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flooring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Moisture Performance of Unvented Attics With Vapor Diffusion Ports and Buried Ducts in Hot, Humid Climates

Energy efficiency measures, such as cool roofs, radiant barriers, interior radiative control coatings, and buried ducts are increasing in popularity and are promoted by energy codes because of their energy-saving potential. However, these strategies can also pose moisture risks in attics by lowering surface temperatures and increasing condensation potential and moisture accumulation. Of particular concern in hot-humid climates is dripping condensation on cold air-conditioning ductwork in the summer - commonly referred to as duct "sweating" - which threatens the attic floor with conditions conducive to mold growth and rot. One strategy to mitigate these moisture issues is to wrap ductwork in thicker duct-wrap insulation with an integrated exterior vapor barrier, but thick duct wrap can be difficult to come by, expensive, and unwieldy to work with. This study explores an alternative strategy of reducing moisture issues while embracing energy efficiency by using unvented attics with vapor diffusion ports and buried ductwork in hot-humid climates. Vapor diffusion ports have been studied so far in a wide range of U.S. climates, mostly in the context of conditioned attics. In this study, the strategy is implemented in the novel context of hot-humid climates with ductwork sitting atop blown-in attic floor insulation in unconditioned attics. Using a combination of field experiments and hygrothermal modeling, the findings of this project indicate that an unvented attic with vapor diffusion ports and buried ducts may be a key part of a successful low-cost method for reducing the attic moisture load by venting excess moisture out of the attic, keeping duct-jacket surfaces above dew point temperature, and keeping the roof deck safe from winter moisture accumulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microreactor Security-by-Design Recommendations for Domestic and International Deployments

This report outlines methods vendors can use to incorporate security-by-design (SeBD) into their microreactor facility design to support and address security for both U.S. and international deployment. The team developed a hypothetical below-grade microreactor with a physical protection system (PPS) to protect the microreactor against acts of theft and sabotage and evaluated it against two adversary attack scenarios defined by a group of adversary subject matter experts (SMEs). The hypothetical microreactor facility consists of two distinct buildings. The first is the above-grade protected area (PA) entry control point (ECP) building, which houses security personnel responsible for conducting screenings and managing access to the PA. The second building is the reactor building, which features both an above-grade floor and a below-grade floor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Product Defect Detection System: SYSM- 5620 Final Project

Retail sales is a growing market estimated to up to seven percent year over year. With this growing market there is also a trend in growing rate of retail returns, estimated just last year at $\$$850 billion. Retail stores must ensure that products available for purchase remain safe, undamaged, and acceptable to customers throughout their time in the store. This job exists regardless of the specific solution used because stores are always responsible for preventing damaged or defective products from reaching customers and when they fail to this is categorized under operation inefficiencies which accounts for an estimated $\$$12 billion in returns. When defective items remain on the sales floor, stores may experience increased returns, reduced customer satisfaction, loss of customer trust, and potential safety concerns depending on the product type. As a result, the core job to be done is to identify defective products quickly, remove them from the sales floor before they are purchased, and preserve useful information about the defect so that the store can improve its handling, stocking, and supplier coordination over time. The need for a more reliable process is especially important in high volume retail environments where employees manage large numbers of products across many aisles, shelves, and storage areas. In these settings, manual inspection alone can be inconsistent and difficult to sustain at the individual item level. At the same time, broader retail trends continue to emphasize operational efficiency, product visibility, and improved customer experience, creating an opportunity for more automated and data driven defect detection methods.

42 ENGINEERING↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

Feasibility of Large-Scale Ocean CO2 Sequestration

Scientific knowledge of natural clathrate hydrates has grown enormously over the past decade, with spectacular new findings of large exposures of complex hydrates on the sea floor, the development of new tools for examining the solid phase in situ, significant progress in modeling natural hydrate systems, and the discovery of exotic hydrates associated with sea floor venting of liquid CO{sub 2}. Major unresolved questions remain about the role of hydrates in response to climate change today, and correlations between the hydrate reservoir of Earth and the stable isotopic evidence of massive hydrate dissociation in the geologic past. The examination of hydrates as a possible energy resource is proceeding apace for the subpermafrost accumulations in the Arctic, but serious questions remain about the viability of marine hydrates as an economic resource. New and energetic explorations by nations such as India and China are quickly uncovering large hydrate findings on their continental shelves. In this report we detail research carried out in the period October 1, 2007 through September 30, 2008. The primary body of work is contained in a formal publication attached as Appendix 1 to this report. In brief we have surveyed the recent literature with respect to the natural occurrence of clathrate hydrates (with a special emphasis on methane hydrates), the tools used to investigate them and their potential as a new source of natural gas for energy production.

03 NATURAL GAS↗

Development of a Hydronic Rooftop Unit-HyPak-MA

The majority of U.S. commercial floor space is cooled by rooftop HVAC units (RTUs). RTU popularity derives chiefly from their low initial cost and relative ease of service access without disturbing building occupants. Unfortunately, current RTUs are inherently inefficient due to a combination of characteristics that unnecessarily increase cooling loads and energy use. 36% percent of annual U.S. energy, and two-thirds of electricity, is consumed in and by buildings. Commercial buildings consume approximately 4.2 quads of energy each year at a cost of $230 billion per year, with HVAC equipment consuming 1.2 quads of electricity. More than half of all U.S. commercial floor space is cooled by packaged HVAC units, most of which are rooftop units (RTUs). Inefficient RTUs create an estimated 3.5% of U.S. CO{sub 2} emissions, thus contributing significantly to global warming5. Also, RTUs often fail to maintain adequate ventilation air and air filtration, reducing indoor air quality. This is the second HyPak project to be supported by DOE through NETL. The prior project, referred to as HyPak-1 in this report, had two rounds of prototype fabrication and testing as well as computer modeling and market research. The HyPak-1 prototypes demonstrated the high performance capabilities of the HyPak concept, but made it clear that further development was required to reduce heat exchanger cost and improve system reliability before HyPak commercialization can commence. The HyPak-1 prototypes were limited to about 25% ventilation air fraction, limiting performance and marketability. The current project is intended to develop a 'mixed-air' product that is capable of full 0-100% modulation in ventilation air fraction, hence it was referred to as HyPak-MA in the proposal. (For simplicity, the -MA has been dropped when referencing the current project.) The objective of the HyPak Project is to design, develop and test a hydronic RTU that provides a quantum improvement over conventional RTU performance. Our proposal targeted 60% and 50% reduction in electrical energy use by the HyPak RTU for dry and humid climates, respectively, when compared with a conventional unit, and reduction in peak energy consumption of 50% and 33% respectively. In addition to performance targets, our goal is to develop a production-ready design with durability, reliability and maintainability similar to air-cooled packaged equipment, and that can be commercialized immediately following the conclusion of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Anthropogenic N Deposition Slows Decay by Favoring Bacterial Metabolism: Insights from Metagenomic Analyses

Litter decomposition is an enzymatically-complex process that is mediated by a diverse assemblage of saprophytic microorganisms. It is a globally important biogeochemical process that can be suppressed by anthropogenic N deposition. In a northern hardwood forest ecosystem located in Michigan, USA, 20 years of experimentally increased atmospheric N deposition has reduced forest floor decay and increased soil C storage. Here, we paired extracellular enzyme assays with shotgun metagenomics to assess if anthropogenic N deposition has altered the functional potential of microbial communities inhabiting decaying forest floor. Experimental N deposition significantly reduced the activity of extracellular enzymes mediating plant cell wall decay, which occurred concurrently with changes in the relative abundance of metagenomic functional gene pathways mediating the metabolism of carbohydrates, aromatic compounds, as well as microbial respiration. Moreover, experimental N deposition increased the relative abundance of 50 of the 60 gene pathways, the majority of which were associated with saprotrophic bacteria. Conversely, the relative abundance and composition of fungal genes mediating the metabolism of plant litter was not affected by experimental N deposition. Future rates of atmospheric N deposition have favored saprotrophic soil bacteria, whereas the metabolic potential of saprotrophic fungi appears resilient to this agent of environmental change. Results presented here provide evidence that changes in the functional capacity of saprotrophic soil microorganisms mediate how anthropogenic N deposition increases C storage in soil.

54 ENVIRONMENTAL SCIENCES↗

3D Measurement Simulation and Relative Pointing Error Verification of the Telescope Mount Assembly Subsystem for the Large Synoptic Survey Telescope

An engineering validation of a large optical telescope consists of executing major performing tests at the subsystem level to verify the overall engineering performance of the observatory. Thus, the relative pointing error verification of the telescope mount assembly subsystem is of special interest to guarantee the absolute pointing performance of the large synoptic survey telescope. This paper presents a new verification method for the relative pointing error assessment of the telescope mount assembly, based on laser tracker technology and several fiducial points fixed to the floor. Monte-Carlo-based simulation results show that the presented methodology is fit for purpose, even if floor movement occurs due to temperature variation during the measurement acquisition process. A further research about laser tracker technology integration into the telescope structure may suggest that such laser tracker technology could be permanently installed in the telescope in order to provide an active alignment system that aims to detect and correct possible misalignment between mirrors or to provide the required mirror positioning verification accuracy after maintenance activities. The obtained results show that two on-board laser tracker systems combined with eight measurement targets could result in measurement uncertainties that are better than 1 arcsec, which would provide a reliable built-in metrology tool for large telescopes.

47 OTHER INSTRUMENTATION↗

Starburst-driven galactic superbubbles radiating to 10 K

Our three-dimensional hydrodynamical simulations of starbursts examine the formation of superbubbles over a range of driving luminosities and mass loadings that determine superbubble growth and wind velocity. From this we determine the relationship between the velocity of a galactic wind (GW) and the power of the starburst. We find a threshold for the formation of a wind, above which the speed of the wind is not affected by grid resolution or the temperature floor of our radiative cooling. We investigate the effect that two different temperature floors in our radiative cooling prescription have on wind kinematics and content. We find that cooling to 10 K instead of to 10{sup 4} K increases the mass fraction of cold neutral and hot X-ray gas in the GW, while halving that in warm Hα. Our simulations show that the mass of cold gas transported into the lower halo does not depend on the starburst strength. Optically bright filaments form at the edge of merging superbubbles, or where a cold dense cloud has been disrupted by the wind. Filaments formed by merging superbubbles will persist and grow to >400 pc in length if anchored to a star forming complex. Filaments embedded in the hot GW contain warm and cold gas that moves 300−1200 km s{sup −1} slower than the surrounding wind, with the coldest gas hardly moving with respect to the Galaxy. Warm and cold matter in the GW show asymmetric absorption profiles consistent with observations, with a thin tail up to the wind velocity.

79 ASTRONOMY AND ASTROPHYSICS↗

THE AGORA HIGH-RESOLUTION GALAXY SIMULATIONS COMPARISON PROJECT. II. ISOLATED DISK TEST

Using an isolated Milky Way-mass galaxy simulation, we compare results from nine state-of-the-art gravito-hydrodynamics codes widely used in the numerical community. We utilize the infrastructure we have built for the AGORA High-resolution Galaxy Simulations Comparison Project. This includes the common disk initial conditions, common physics models (e.g., radiative cooling and UV background by the standardized package Grackle) and common analysis toolkit yt, all of which are publicly available. Subgrid physics models such as Jeans pressure floor, star formation, supernova feedback energy, and metal production are carefully constrained across code platforms. With numerical accuracy that resolves the disk scale height, we find that the codes overall agree well with one another in many dimensions including: gas and stellar surface densities, rotation curves, velocity dispersions, density and temperature distribution functions, disk vertical heights, stellar clumps, star formation rates, and Kennicutt–Schmidt relations. Quantities such as velocity dispersions are very robust (agreement within a few tens of percent at all radii) while measures like newly formed stellar clump mass functions show more significant variation (difference by up to a factor of ∼3). Systematic differences exist, for example, between mesh-based and particle-based codes in the low-density region, and between more diffusive and less diffusive schemes in the high-density tail of the density distribution. Yet intrinsic code differences are generally small compared to the variations in numerical implementations of the common subgrid physics such as supernova feedback. Our experiment reassures that, if adequately designed in accordance with our proposed common parameters, results of a modern high-resolution galaxy formation simulation are more sensitive to input physics than to intrinsic differences in numerical schemes.

79 ASTRONOMY AND ASTROPHYSICS↗

Inferring the Heliospheric Magnetic Field Back through Maunder Minimum

Recent solar conditions include a prolonged solar minimum (2005–2009) and a solar maximum that has not fully recovered in terms of the Heliospheric Magnetic Field (HMF) strength when compared to the previous maximum values. These anomalies may indicate that we are entering an era of lower solar activity than observed at other times during the space age. We study past solar grand minima, especially the Maunder period (1645–1715) to gain further insight into grand minima. We find the timescale parameters associated with three processes attributed to the magnetic flux balance in the heliosphere using chi-square analysis. We use HMF time series reconstructed based on geomagnetic data and near-Earth spacecraft measurements (OMNI) data to find the fundamental timescales that influence heliospheric field evolution through conversion or opening of magnetic flux from coronal mass ejections (CMEs) into the ambient heliospheric field, removal or loss of the ambient heliospheric field through magnetic reconnection, and interchange reconnection between CME magnetic flux and ambient heliospheric magnetic flux. We also investigate the existence of a floor in the heliospheric magnetic flux, in the absence of CMEs, and show that a floor ⩽1.49nT is sufficient to successfully describe the HMF evolution. The minimum value for the HMF at 1 au in the model-predicted historic record is 3.13 ± 0.35 nT. Our model results favorably reproduce paleocosmic data and near-Earth spacecraft measurements data and show how the HMF may evolve through periods of extremely low activity.

79 ASTRONOMY AND ASTROPHYSICS↗

Stratospheric temperature measurements from nanosatellite stellar occultation observations of refractive bending

Abstract. Stellar occultation observations from space can probe the stratosphere and mesosphere at a fine vertical scale around the globe. Unlike other measurement techniques like radiosondes and aircraft, stellar occultation has the potential to observe the atmosphere above 30 km, and unlike radio occultation, stellar occultation probes fine-scale phenomena with potential to observe atmospheric turbulence. We imaged the refractive bending angle of a star centroid for a series of occultations by the atmosphere. Atmospheric refractivity, density, and then temperature are retrieved from the bending observations with the Abel transformation and Edlén's law, the hydrostatic equation, and the ideal gas law. The retrieval technique is applied to data collected by two nanosatellites operated by Terran Orbital. Measurements were primarily taken by the GEOStare SV2 mission, with a dedicated imaging telescope, supplemented with images captured by spacecraft bus sensors, namely the star trackers on other Terran Orbital missions. The bending angle noise floor is 10 and 30 arcsec for the star tracker and GEOStare SV2 data, respectively. The most significant sources of uncertainty are due to centroiding errors due to the fairly low-resolution stellar images and telescope pointing knowledge derived from noisy satellite attitude sensors. The former mainly affects the star tracker data, while the latter limits the GEOStare SV2 accuracy, with both providing low vertical resolution. This translates to a temperature profile retrieval up to roughly 20 km for both star tracker and GEOStare SV2 datasets. In preparation of an upcoming 2023 mission designed to correct these deficiencies, SOHIP, we simulated bending angle measurements with varying magnitudes of error. The expected maximum altitude of retrieved temperature is 41 km on average for these simulated measurements with a noise floor of 0.39 arcsec. Our work highlights the capabilities of stellar occultation observations from nanosatellites for atmospheric sounding. Future work will investigate high-frequency observations of atmospheric gravity waves and turbulence, mitigating the major uncertainties observed in these datasets.

54 ENVIRONMENTAL SCIENCES↗

Preliminary Wind-Tunnel Investigation of the Performance of Republic F-105 Wing-Root Inlet Configurations at Various Angles of Attack and a Mach Number of 2.01

A 1/13-scale model of the forebody of the Republic F-105 with twin-duct wing-root inlets was tested in the Langley 4- by 4-foot supersonic pressure tunnel through a range of angle of attack from -4 deg to 15 deg at a Mach number of 2.01 and a Reynolds number of approximately 3.4 x 10(exp 6) per foot. The tests were made with four configurations which incorporated varying amounts of sweep and stagger of the inlet leading edges, modifications to the areas of the boundary-layer diverter floor plate, and modifications to the area of the boundary-layer diverter bleed slots. The highest overall pressure recovery at an angle of attack of 0 deg (average total-pressure recovery, 0.84 mass-flow ratio, 0.98) was achieved with configuration having an inlet leading-edge sweep angle of 58 deg with no leading-edge stagger. Stagger was found to improve the angle-of- attack performance, but at a sacrifice in inlet efficiency for an angle of attack of 0 deg. The boundary-layer diverter floor height, of the order of one boundary-layer thickness, was satisfactory for bypassing the fuselage boundary layer. The boundary-layer diverter-plate bleed slots were effective in increasing the total-pressure recovery of the inlet. The total-pressure-recovery contour plots, taken at the compressor-face station, indicate the existence of high-velocity "cores" throughout the inlet operating range.

Kouyoumjian, W. L.↗

Tilt table for ergometers and other biomedical devices

Table adjusts to any position between horizontal and vertical. Apparatus includes - floor plate, plate hinged to floor plate, for carrying ergometer, hydraulic cylinder and piston on plate sides, linking them, hydraulic system, positive stops, padded backrest and headrest, one hand controls, and constraint system.

Gause, R. L.↗

Application study of filamentary composites in a commercial jet aircraft fuselage

A study of applications of filamentary composite materials to aircraft fuselage structure was performed. General design criteria were established and material studies conducted using the 727-200 forebody as the primary structural component. Three design approaches to the use of composites were investigated: uniaxial reinforcement of metal structure, uniaxial and biaxial reinforcement of metal structure, and an all-composite design. Materials application studies for all three concepts were conducted on fuselage shell panels, keel beam, floor beams, floor panels, body frames, fail-safe straps, and window frames. Cost benefit studies were conducted and developmental program costs estimated. On the basis of weight savings, cost effectiveness, developmental program costs, and potential for early application on commercial aircraft, the unaxial design is recommended for a 5-year flight service evaluation program.

Johnson, R. W.↗

The relative age of the transition zone between Hellas and the Martian cratered terrain.

Consideration of the relationships of craters to scarps and ridges and of the antiquity of Hellas relative to the cratered terrain. Scarps and ridges in the transition zone between Hellas and the cratered terrain both postdate and predate large craters. It appears that there are a number of craters which are older than the transition zone structures, which in turn are presumably related in some way to the formation of Hellas. Sharp et al. (1971) have suggested impact, large-scale volcanic explosion, or subsidence for the origin of Hellas. Volcanic explosion seems the least likely explanation, for the resulting deficiency of mass beneath Hellas should induce later isostatic rebound, contrary to observations of the transition zone which imply subsidence relatively late in the history of the Martian surface. An origin of Hellas by impact with later isostatic subsidence (because of a dense mass under its floor, as suggested by Sharp et al.) to account for the characteristics of the transition zone seems to be the best model, and may also account for the featureless floor of the basin.

Thorman, C. H.↗