Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Reliability analysis of an ultra-reliable fault tolerant control system

This report analyzes the reliability of NASA's Ultra-reliable Fault Tolerant Control System (UFTCS) architecture as it is currently envisioned for helicopter control. The analysis is extended to air transport and spacecraft control using the same computational and voter modules applied within the UFTCS architecture. The system reliability is calculated for several points in the helicopter, air transport, and space flight missions when there are initially 4, 5, and 6 operating channels. Sensitivity analyses are used to explore the effects of sensor failure rates and different system configurations at the 10 hour point of the helicopter mission. These analyses show that the primary limitation to system reliability is the number of flux windings on each flux summer (4 are assumed for the baseline case). Tables of system reliability at the 10 hour point are provided to allow designers to choose a configuration to meet specified reliability goals.

Curry, R. E.↗

Utilization of Mobile VLBI for Geodetic Measurements

Three mobile very long base interferometry (VLBI) systems were fabricated for the NASA Crustal Dynamics Project. These systems include the 9-meter-diameter MV-3 telescope. Since 1980, mobile systems operated in conjunction with several fixed base stations in the western United States as part of a geodetic survey program to determine relative motions and regional strain fields near the tectonic plate boundaries in California and Alaska. A description is given of the three mobile systems and the environment in which they must function. The inherent accuracy of mobile VLBI measurements is assessed, based on a consideration of major sources of error. Some recent results are presented which serve to illustrate various aspects of the error model and are of geodetic interest as they span the broad region surrounding the surface trace of the San Andreas Fault. These results indicate that baseline measurements utilizing the current mobile VLBI systems attained an accuracy of 2 cm or better in the horizontal plane. It is likely that crustal motions will be detected within the next few years, provided they are presently occurring at the geological rates.

Davidson, J. M.↗

Utilization of mobile VLBI for geodetic measurements

Three mobile very long base interferometry (VLBI) systems were fabricated for the NASA Crustal Dynamics Project. These systems include the 9-meter-diameter MV-3 telescope. Since 1980, mobile systems operated in conjunction with several fixed base stations in the western United States as part of a geodetic survey program to determine relative motions and regional strain fields near the tectonic plate boundaries in California and Alaska. A description is given of the three mobile systems and the environment in which they must function. The inherent accuracy of mobile VLBI measurements is assessed, based on a consideration of major sources of error. Some recent results are presented which serve to illustrate various aspects of the error model and are of geodetic interest as they span the broad region surrounding the surface trace of the San Andreas Fault. These results indicate that baseline measurements utilizing the current mobile VLBI systems attained an accuracy of 2 cm or better in the horizontal plane. It is likely that crustal motions will be detected within the next few years, provided they are presently occurring at the geological rates.

Davidson, J. M.↗

Precise time and time interval applications to electric power systems

There are many applications of precise time and time interval (frequency) in operating modern electric power systems. Many generators and customer loads are operated in parallel. The reliable transfer of electrical power to the consumer partly depends on measuring power system frequency consistently in many locations. The internal oscillators in the widely dispersed frequency measuring units must be syntonized. Elaborate protection and control systems guard the high voltage equipment from short and open circuits. For the highest reliability of electric service, engineers need to study all control system operations. Precise timekeeping networks aid in the analysis of power system operations by synchronizing the clocks on recording instruments. Utility engineers want to reproduce events that caused loss of service to customers. Precise timekeeping networks can synchronize protective relay test-sets. For dependable electrical service, all generators and large motors must remain close to speed synchronism. The stable response of a power system to perturbations is critical to continuity of electrical service. Research shows that measurement of the power system state vector can aid in the monitoring and control of system stability. If power system operators know that a lightning storm is approaching a critical transmission line or transformer, they can modify operating strategies. Knowledge of the location of a short circuit fault can speed the re-energizing of a transmission line. One fault location technique requires clocks synchronized to one microsecond. Current research seeks to find out if one microsecond timekeeping can aid and improve power system control and operation.

Robert E. Wilson↗

Prospective communications research to support fly by light/power by wire

A NASA Research Grant NAG-1-1309, Distributed Fiber Optic Systems for Commercial Aircraft, was awarded during July 1991. This report primarily constitutes a summary of findings of the original background research done at that time. NASA is embarking on a research project to design the next generation of commercial aircraft, fly by light/power by wire. The objectives of this effort are to improve commercial aircraft design by (1) reducing the weight of the aircraft to improve efficiency and (2) improving the fault tolerance and safety of the aircraft by enhancing current systems with new technologies or introducing new systems into the aircraft.

Game, David↗

A Comparison of Functional Models for Use in the Function-Failure Design Method

When failure analysis and prevention, guided by historical design knowledge, are coupled with product design at its conception, shorter design cycles are possible. By decreasing the design time of a product in this manner, design costs are reduced and the product will better suit the customer s needs. Prior work indicates that similar failure modes occur with products (or components) with similar functionality. To capitalize on this finding, a knowledge base of historical failure information linked to functionality is assembled for use by designers. One possible use for this knowledge base is within the Elemental Function-Failure Design Method (EFDM). This design methodology and failure analysis tool begins at conceptual design and keeps the designer cognizant of failures that are likely to occur based on the product s functionality. The EFDM offers potential improvement over current failure analysis methods, such as FMEA, FMECA, and Fault Tree Analysis, because it can be implemented hand in hand with other conceptual design steps and carried throughout a product s design cycle. These other failure analysis methods can only truly be effective after a physical design has been completed. The EFDM however is only as good as the knowledge base that it draws from, and therefore it is of utmost importance to develop a knowledge base that will be suitable for use across a wide spectrum of products. One fundamental question that arises in using the EFDM is: At what level of detail should functional descriptions of components be encoded? This paper explores two approaches to populating a knowledge base with actual failure occurrence information from Bell 206 helicopters. Functional models expressed at various levels of detail are investigated to determine the necessary detail for an applicable knowledge base that can be used by designers in both new designs as well as redesigns. High level and more detailed functional descriptions are derived for each failed component based on NTSB accident reports. To best record this data, standardized functional and failure mode vocabularies are used. Two separate function-failure knowledge bases are then created aid compared. Results indicate that encoding failure data using more detailed functional models allows for a more robust knowledge base. Interestingly however, when applying the EFDM, high level descriptions continue to produce useful results when using the knowledge base generated from the detailed functional models.

Stock, Michael E.↗

Validation of Helicopter Gear Condition Indicators Using Seeded Fault Tests

A "seeded fault test" in support of a rotorcraft condition based maintenance program (CBM), is an experiment in which a component is tested with a known fault while health monitoring data is collected. These tests are performed at operating conditions comparable to operating conditions the component would be exposed to while installed on the aircraft. Performance of seeded fault tests is one method used to provide evidence that a Health Usage Monitoring System (HUMS) can replace current maintenance practices required for aircraft airworthiness. Actual in-service experience of the HUMS detecting a component fault is another validation method. This paper will discuss a hybrid validation approach that combines in service-data with seeded fault tests. For this approach, existing in-service HUMS flight data from a naturally occurring component fault will be used to define a component seeded fault test. An example, using spiral bevel gears as the targeted component, will be presented. Since the U.S. Army has begun to develop standards for using seeded fault tests for HUMS validation, the hybrid approach will be mapped to the steps defined within their Aeronautical Design Standard Handbook for CBM. This paper will step through their defined processes, and identify additional steps that may be required when using component test rig fault tests to demonstrate helicopter CI performance. The discussion within this paper will provide the reader with a better appreciation for the challenges faced when defining a seeded fault test for HUMS validation.

Dempsey, Paula↗

OPERATIONAL TOPOLOGY ESTIMATION OF THREE PHASE UNBALANCED POWER DISTRIBUTION SYSTEMS WITH OUTAGES

Distribution grid, in general, is constructionally loopy but a radially operated network. Opening and closing of suitable tie-switches allows transition from one radial topology to another. Tie-switches ensure reliability and provide restoration paths when faults (outages) occur. The estimation of the system's current operational topology is a precursor to implementing any optimal control actions (during normal operation) or restorative actions (during outage condition). The existing literature in topology detection suffers with several limitations including: (1) computationally intensive nonlinear formulations that are not scalable for large distribution systems, (2) methods requiring exhaustive search for the correct topology by enumerating the complete topological search space, and (3) approaches requiring large volumes of time-series measurements and are not applicable for estimating continuously changing operational topology. Furthermore, the existing literature on distribution grid topology estimation cannot be extended to estimate the operational topology during outage conditions. For operational topology estimation during outages, our objective is to estimate both energized radial feeder and the outaged sections. Starting with a radial topology, these methods identify outaged feeder sections and hence, are inapplicable when the current radial operational topology is not known. In this work, we present a mathematical programming approach to estimate the operational topology of a three-phase unbalanced power distribution system under both outage and normal operating conditions. The aforementioned limitations of existing literature were countered by modeling the problem as a mixed-integer linear programming (MILP) problem which minimizes the errors in available measurements while satisfying the power flow and structural constraints of the system. Specically, a minimum weighted least absolute value estimator is proposed that uses the instantaneous line flow measurements, historical/ forecasted load data, and ping measurements from a limited set of smart meters and solves an MILP to identify the operational topology based on a linearized three-phase unbalanced power flow model. The proposed approach is tested on IEEE 123-bus feeder and 1069 bus multi-feeder test system and the numerical results prove the applicability of the proposed method to large three phase unbalanced grids with high errors in measurements. It is observed that the approach performs well even at high percentages of measurement errors.

GANDLURU NAGA, ANANDINI↗

Oxide-nitride heteroepitaxy for low-loss dielectrics in superconducting quantum circuits

Superconducting qubits show great promise for the realization of fault-tolerant quantum computing, but lossy, amorphous dielectrics limit current technology. Identifying highly crystalline and stoichiometric dielectrics with intrinsically low microwave loss is therefore a central materials challenge, yet experimentally validated platforms remain scarce. In this work, we integrate a crystalline dielectric into a heteroepitaxial TiN/$γ$-Al$_2$O$_3$/TiN trilayer grown via pulsed laser deposition. Correlative high-resolution imaging, diffraction, and spectroscopy measurements confirm the single-crystal quality and chemical integrity of all layers, with minimal defects and limited anion interdiffusion across the oxide-nitride interfaces. Using microwave lumped-element resonators with parallel-plate capacitors, we report the first direct measurement of the dielectric loss of epitaxial $γ$-Al$_2$O$_3$, for which we find a low intrinsic two-level system loss, $δ_{\text{TLS}}^0 = (2.8 \pm 0.1) \times 10^{-5}$. These results establish heteroepitaxial oxides on transition metal nitrides as an attractive materials platform for superconducting quantum circuits, particularly for integration into compact device architectures such as merged-element transmons and microwave kinetic inductance detectors.

Garcia-Wetten, David A. [Northwestern U.]↗

Steps toward fault-tolerant quantum chemistry.

Developing quantum chemistry programs on the coming generation of exascale computers will be a difficult task. The programs will need to be fault-tolerant and minimize the use of global operations. This work explores the use a task-based model that uses a data-centric approach to allocate work to different processes as it applies to quantum chemistry. After introducing the key problems that appear when trying to parallelize a complicated quantum chemistry method such as coupled-cluster theory, we discuss the implications of that model as it pertains to the computational kernel of a coupled-cluster program - matrix multiplication. Also, we discuss the extensions that would required to build a full coupled-cluster program using the task-based model. Current programming models for high-performance computing are fault-intolerant and use global operations. Those properties are unsustainable as computers scale to millions of CPUs; instead one must recognize that these systems will be hierarchical in structure, prone to constant faults, and global operations will be infeasible. The FAST-OS HARE project is introducing a scale-free computing model to address these issues. This model is hierarchical and fault-tolerant by design, allows for the clean overlap of computation and communication, reducing the network load, does not require checkpointing, and avoids the complexity of many HPC runtimes. Development of an algorithm within this model requires a change in focus from imperative programming to a data-centric approach. Quantum chemistry (QC) algorithms, in particular electronic structure methods, are an ideal test bed for this computing model. These methods describe the distribution of electrons in a molecule, which determine the properties of the molecule. The computational cost of these methods is high, scaling quartically or higher in the size of the molecule, which is why QC applications are major users of HPC resources. The complexity of these algorithms means that MPI alone is insufficient to achieve parallel scaling; QC developers have been forced to use alternative approaches to achieve scalability and would be receptive to radical shifts in the programming paradigm. Initial work in adapting the simplest QC method, Hartree-Fock, to this the new programming model indicates that the approach is beneficial for QC applications. However, the advantages to being able to scale to exascale computers are greatest for the computationally most expensive algorithms; within QC these are the high-accuracy coupled-cluster (CC) methods. Parallel coupledcluster programs are available, however they are based on the conventional MPI paradigm. Much of the effort is spent handling the complicated data dependencies between the various processors, especially as the size of the problem becomes large. The current paradigm will not survive the move to exascale computers. Here we discuss the initial steps toward designing and implementing a CC method within this model. First, we introduce the general concepts behind a CC method, focusing on the aspects that make these methods difficult to parallelize with conventional techniques. Then we outline what is the computational core of the CC method - a matrix multiply - within the task-based approach that the FAST-OS project is designed to take advantage of. Finally we outline the general setup to implement the simplest CC method in this model, linearized CC doubles (LinCC).

99 GENERAL AND MISCELLANEOUS↗

Enhanced Large-Signal Stability Method for Grid-Forming Inverters During Current Limiting: Preprint

Grid-forming (GFM) inverters are a promising technology for the widespread integration of renewable energy sources in future power systems. As a key element of GFM inverter control, the primary controller governs the internal reference voltage and angle. During contingencies in the grid---such as faults, voltage drops, or frequency and phase jumps---an inverter can be forced into a current-limiting mode of operation modulating inverter dynamics, and, as a result, it is prone to losing synchronism with the grid. In this paper, we propose a novel GFM primary control method with an additional synchronization term that naturally activates during contingencies to improve the dynamic response. The method allows the inverter to remain synchronized with the grid, which improves the inverter's dynamic behavior both during and after current-limiting grid conditions and enhances grid support, including voltage support using full current capacity. The method is demonstrated for voltage, frequency, and phase jumps both in a single-machine-to-infinite-bus and a network-wide electromagnetic transient simulation of the IEEE 14-bus system with 5 GFM inverters. The simulations provide insights into the proposed synchronization method and confirm the high potential of the method, which robustly secures synchronism under severe contingencies.

current limiting↗

Flight deck engine advisor

The focus of this project is on alerting pilots to impending events in such a way as to provide the additional time required for the crew to make critical decisions concerning non-normal operations. The project addresses pilots' need for support in diagnosis and trend monitoring of faults as they affect decisions that must be made within the context of the current flight. Monitoring and diagnostic modules developed under the NASA Faultfinder program were restructured and enhanced using input data from an engine model and real engine fault data. Fault scenarios were prepared to support knowledge base development activities on the MONITAUR and DRAPhyS modules of Faultfinder. An analysis of the information requirements for fault management was included in each scenario. A conceptual framework was developed for systematic evaluation of the impact of context variables on pilot action alternatives as a function of event/fault combinations.

Shontz, W. D.↗

Application health monitoring for extreme-scale resiliency using cooperative fault management

Resiliency is and will be a critical factor in determining scientific productivity on current and exascale supercomputers, and beyond. Applications oblivious to and incapable of handling transient soft and hard errors could waste supercomputing resources or, worse, yield misleading scientific insights. In this work, we introduce a novel application-driven silent error detection and recovery strategy based on application health monitoring. Our methodology uses application output that follows known patterns, as indicators of an application's health and knowledge that violation of these patterns could be indication of faults. Information from system monitors that report hardware and software health status is used to corroborate faults. Collectively, this information is used by a fault coordinator agent to take preventive and corrective measures by applying computational steering to an application between checkpoints. This cooperative fault management system uses the Fault Tolerance Backplane as a communication channel. The benefits of this framework are demonstrated with two real application case studies, molecular dynamics, and quantum chemistry simulations, on scalable clusters with simulated memory and I/O corruptions. Lastly, the developed approach is general and can be easily applied to other applications.

97 MATHEMATICS AND COMPUTING↗

High Impedance Fault Detection Through Quasi-Static State Estimation: A Parameter Error Modeling Approach

This paper presents a model for detecting high impedance faults using parameter error modeling and a two step per-phase weighted-least squares state estimation process. The proposed scheme leverages the use of Phasor Measurement Units and synthetic measurements to identify per-phase power flow and injection measurements which indicate a parameter error through ?2 Hypothesis Testing applied to the composed measurement error. Although current and voltage waveforms are commonly analyzed for high-impedance fault detection, wide area power flow and injection measurements, which are already inherent to the state estimation process, also show promise for real-world high-impedance fault detection applications. The error distributions after detection share the measurement function error spread observed in proven parameter error diagnostics and can be applied to high-impedance fault identification. Further, this error spread across measurement functions related to the fault will be clearly discerned from measurement error. Case studies are performed on the IEEE 33-Bus Distribution System along with the proposed model in Simulink.

Cooper, Austin↗

An Innovative Circuit Breaker for Renewable Power Grids

A key step towards a carbon-neutral future could be reached through dispersed power grids, featuring networks of local-scale renewable energy and battery storage plants. To prevent these power grids from damaging themselves and their surroundings when electrical faults arise, they must be integrated with ‘circuit breakers’, which temporarily interrupt the current flowing through them. However, currently available circuit breakers cannot handle the medium-voltage direct currents best suited for these grids. Through an innovative new circuit breaker design, Steve Schmalz and his colleagues at Eaton Corporation, the Illinois Institute of Technology (IIT), Virginia Tech and the National Energy Technology Laboratory (NETL), hope that this challenge will soon be overcome.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Laboratory Studies of Particle Cementation and PV Module Soiling

Monitoring of photovoltaic (PV) systems can maintain efficient operations. However, extensive monitoring of large quantities of data can be a cumbersome process. The present work introduces a simple, inexpensive, yet effective data monitoring strategy for detecting faults and determining lost revenues automatically. This was achieved through the deployment of Raspberry Pi (RPI) device at a PV system's combiner box. The RPI was programmed to collect PV data through Modbus communications, and store the data locally in a MySQL database. Then, using a Gaussian Process Regression algorithm the RPI device was able to accurately estimate string level current, voltage, and power values. The device could also detect system faults using a Support Vector Novelty Detection algorithm. Finally, the RPI was programmed to output the potential lost revenue caused by the abnormal condition. The system analytics information was then displayed on a user interface. The interface could be accessed by operations personal to direct maintenance activity so that critical issues can be solved quickly.

14 SOLAR ENERGY↗

Ensemble models for circuit topology estimation, fault detection and classification in distribution systems

This paper presents a methodology for simultaneous fault detection, classification, and topology estimation for adaptive protection of distribution systems. The methodology estimates the probability of the occurrence of each one of these events by using a hybrid structure that combines three sub-systems, a convolutional neural network for topology estimation, a fault detection based on predictive residual analysis, and a standard support vector machine with probabilistic output for fault classification. The input to all these sub-systems is the local voltage and current measurements. A convolutional neural network uses these local measurements in the form of sequential data to extract features and estimate the topology conditions. The fault detector is constructed with a Bayesian stage (a multitask Gaussian process) that computes a predictive distribution (assumed to be Gaussian) of the residuals using the input. Since the distribution is known, these residuals can be transformed into a Standard distribution, whose values are then introduced into a one-class support vector machine. The structure allows using a one-class support vector machine without parameter cross-validation, so the fault detector is fully unsupervised. Finally, a support vector machine uses the input to perform the classification of the fault types. All three sub-systems can work in a parallel setup for both performance and computation efficiency. In conclusion, we test all three sub-systems included in the structure on a modified IEEE123 bus system, and we compare and evaluate the results with standard approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Fault Location Using the Retardation Method

A new method for short-circuit fault location is proposed. The method is based on instantaneous signal measurement and its first and second derivatives, which are the novel elements of the current approach. The derivatives allow associating a precise time stamp to the occurrence of the fault. Due to retardation phenomena, the difference between the times in which a signal is registered in two detectors can be used to locate the fault. We offer several mathematical models to describe the fault. Although a description of faults in terms of a lumped circuit is useful for elucidating the methods for detecting the fault, this description will not suffice to describe the fault signal propagation; hence, a distributed models is needed, which is given in terms of the telegraph equations. Those equations were used to derive a transmission line transfer function, and an exact analytical description of the fault signal propagating in the transmission line was obtained. The analytical solution was verified both by numerical simulations and experimentally.

42 ENGINEERING↗