Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Accuracy Analysis for Finite-Volume Discretization Schemes on Irregular Grids

A new computational analysis tool, downscaling test, is introduced and applied for studying the convergence rates of truncation and discretization errors of nite-volume discretization schemes on general irregular (e.g., unstructured) grids. The study shows that the design-order convergence of discretization errors can be achieved even when truncation errors exhibit a lower-order convergence or, in some cases, do not converge at all. The downscaling test is a general, efficient, accurate, and practical tool, enabling straightforward extension of verification and validation to general unstructured grid formulations. It also allows separate analysis of the interior, boundaries, and singularities that could be useful even in structured-grid settings. There are several new findings arising from the use of the downscaling test analysis. It is shown that the discretization accuracy of a common node-centered nite-volume scheme, known to be second-order accurate for inviscid equations on triangular grids, degenerates to first order for mixed grids. Alternative node-centered schemes are presented and demonstrated to provide second and third order accuracies on general mixed grids. The local accuracy deterioration at intersections of tangency and in flow/outflow boundaries is demonstrated using the DS tests tailored to examining the local behavior of the boundary conditions. The discretization-error order reduction within inviscid stagnation regions is demonstrated. The accuracy deterioration is local, affecting mainly the velocity components, but applies to any order scheme.

Diskin, Boris↗

Effective noise-suppressed and artifact-reduced reconstruction of SPECT data using a preconditioned alternating projection algorithm

Purpose: The authors have recently developed a preconditioned alternating projection algorithm (PAPA) with total variation (TV) regularizer for solving the penalized-likelihood optimization model for single-photon emission computed tomography (SPECT) reconstruction. This algorithm belongs to a novel class of fixed-point proximity methods. The goal of this work is to investigate how PAPA performs while dealing with realistic noisy SPECT data, to compare its performance with more conventional methods, and to address issues with TV artifacts by proposing a novel form of the algorithm invoking high-order TV regularization, denoted as HOTV-PAPA, which has been explored and studied extensively in the present work. Methods: Using Monte Carlo methods, the authors simulate noisy SPECT data from two water cylinders; one contains lumpy “warm” background and “hot” lesions of various sizes with Gaussian activity distribution, and the other is a reference cylinder without hot lesions. The authors study the performance of HOTV-PAPA and compare it with PAPA using first-order TV regularization (TV-PAPA), the Panin–Zeng–Gullberg one-step-late method with TV regularization (TV-OSL), and an expectation–maximization algorithm with Gaussian postfilter (GPF-EM). The authors select penalty-weights (hyperparameters) by qualitatively balancing the trade-off between resolution and image noise separately for TV-PAPA and TV-OSL. However, the authors arrived at the same penalty-weight value for both of them. The authors set the first penalty-weight in HOTV-PAPA equal to the optimal penalty-weight found for TV-PAPA. The second penalty-weight needed for HOTV-PAPA is tuned by balancing resolution and the severity of staircase artifacts. The authors adjust the Gaussian postfilter to approximately match the local point spread function of GPF-EM and HOTV-PAPA. The authors examine hot lesion detectability, study local spatial resolution, analyze background noise properties, estimate mean square errors (MSEs), and report the convergence speed and computation time. Results: HOTV-PAPA yields the best signal-to-noise ratio, followed by TV-PAPA and TV-OSL/GPF-EM. The local spatial resolution of HOTV-PAPA is somewhat worse than that of TV-PAPA and TV-OSL. Images reconstructed using HOTV-PAPA have the lowest local noise power spectrum (LNPS) amplitudes, followed by TV-PAPA, TV-OSL, and GPF-EM. The LNPS peak of GPF-EM is shifted toward higher spatial frequencies than those for the three other methods. The PAPA-type methods exhibit much lower ensemble noise, ensemble voxel variance, and image roughness. HOTV-PAPA performs best in these categories. Whereas images reconstructed using both TV-PAPA and TV-OSL are degraded by severe staircase artifacts; HOTV-PAPA substantially reduces such artifacts. It also converges faster than the other three methods and exhibits the lowest overall reconstruction error level, as measured by MSE. Conclusions: For high-noise simulated SPECT data, HOTV-PAPA outperforms TV-PAPA, GPF-EM, and TV-OSL in terms of hot lesion detectability, noise suppression, MSE, and computational efficiency. Unlike TV-PAPA and TV-OSL, HOTV-PAPA does not create sizable staircase artifacts. Moreover, HOTV-PAPA effectively suppresses noise, with only limited loss of local spatial resolution. Of the four methods, HOTV-PAPA shows the best lesion detectability, thanks to its superior noise suppression. HOTV-PAPA shows promise for clinically useful reconstructions of low-dose SPECT data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Educating local radial basis functions using the highest gradient of interest in three dimensional geometries: EDUCATING LOCALIZED RBF-SCHEMES

We present a novel methodology to effectively localize radial basis function approximation methods in three dimensions. The local scheme requires shape parameter-dependent functions that can be used to approximate gradients of scattered data and to solve partial differential operators. The optimum shape parameter is obtained from the highest gradient of interest, where a known analytical function, when boundary conditions are not present, or a shape parameter-free global approximation are used to educate the localized scheme. The later option is applicable to problems where the operator needs to be solved multiple times, like in time evolution or stochastic integration. Past shape parameter's optimizations, for two-dimensional domains, based on the condition number of the interpolant matrix, were unable to provide satisfactory approximations. The applicability of our method is illustrated in the context of an analytical expression interpolation and during a Ginzburg-Landau relaxation of a free energy functional. In general, the optimum shape parameter depends on geometry, node distribution, and density, whereas the approximation errors decrease as the node density and the local stencil size increase. The effective localization of radial basis functions motivates its use in moving boundary problems and accelerates solutions through sparse matrix solvers.

free energy functional↗

Bone-marrow densitometry: Assessment of marrow space of human vertebrae by single energy high resolution-quantitative computed tomography

Purpose: Accurate noninvasive assessment of vertebral bone marrow fat fraction is important for diagnostic assessment of a variety of disorders and therapies known to affect marrow composition. Moreover, it provides a means to correct fat-induced bias of single energy quantitative computed tomography (QCT) based bone mineral density (BMD) measurements. The authors developed new segmentation and calibration methods to obtain quantitative surrogate measures of marrow-fat density in the axial skeleton. Methods: The authors developed and tested two high resolution-QCT (HR-QCT) based methods which permit segmentation of bone voids in between trabeculae hypothesizing that they are representative of bone marrow space. The methods permit calculation of marrow content in units of mineral equivalent marrow density (MeMD). The first method is based on global thresholding and peeling (GTP) to define a volume of interest away from the transition between trabecular bone and marrow. The second method, morphological filtering (MF), uses spherical elements of different radii (0.1–1.2 mm) and automatically places them in between trabeculae to identify regions with large trabecular interspace, the bone-void space. To determine their performance, data were compared ex vivo to high-resolution peripheral CT (HR-pQCT) images as the gold-standard. The performance of the methods was tested on a set of excised human vertebrae with intact bone marrow tissue representative of an elderly population with low BMD. Results: 86% (GTP) and 87% (MF) of the voxels identified as true marrow space on HR-pQCT images were correctly identified on HR-QCT images and thus these volumes of interest can be considered to be representative of true marrow space. Within this volume, MeMD was estimated with residual errors of 4.8 mg/cm{sup 3} corresponding to accuracy errors in fat fraction on the order of 5% both for GTP and MF methods. Conclusions: The GTP and MF methods on HR-QCT images permit noninvasive localization and densitometric assessment of marrow fat with residual accuracy errors sufficient to study disorders and therapies known to affect bone marrow composition. Additionally, the methods can be used to correct BMD for fat induced bias. Application and testing in vivo and in longitudinal studies are warranted to determine the clinical performance and value of these methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stochastic-Dynamical Modeling of Space Time Rainfall

The focus of this research work is the elucidation of the physical origins of the observed extreme-rainfall variability over tropical oceans. The quantitative results of this work may be used to establish links between deterministic models of the mesoscale and synoptic scale with statistical descriptions of the temporal variability of local tropical oceanic rainfall. In addition, they may be used to quantify the influence of measurement error in large-scale forcing and cloud scale observations on the accuracy of local rainfall variability inferences, important for hydrologic studies. A simple statistical-dynamical model, suitable for use in repetitive Monte Carlo experiments, is formulated as a diagnostic tool for this purpose. Stochastic processes with temporal structure and parameters estimated from observed large-scale data represent large-scale forcing.

Georgankakos, Konstantine P.↗

Quantum memories based on engineered dissipation

Storing quantum information for long times without disruptions is a major requirement for most quantum information technologies. A very appealing approach is to use self-correcting Hamiltonians, that is tailoring local interactions among the qubits such that when the system is weakly coupled to a cold bath the thermalization process takes a long time. Here we propose an alternative but more powerful approach in which the coupling to a bath is engineered, so that dissipation protects the encoded qubit against more general kinds of errors. We show that the method can be implemented locally in four-dimensional lattice geometries by means of a toric code and propose a simple two-dimensional setup for proof-of-principle experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tracking Coastal Change in American Samoa By Mapping Local Vertical Land Motion with PS-InSAR

Characterizingdiverse contributionsto coastal land change is a key step to mitigating the effects ofrising sea levels that threaten coastal communities. This taskis particularly critical for small island communities in tectonically active regions, which are highlyvulnerableto the effects of sea level rise. We highlight here a case study to extract regional estimates of vertical land motion (VLM) over American Samoa, which in recent years has observedincreased nuisance flooding.Weusedpersistent scatterer Interferometric Synthetic Aperture Radar (PS-InSAR)to derive high-resolutionestimates of crustaldeformationinpopulated regions overTutuila Island from 2015 to 2021. While the area is small and highly vegetatedand poses challenges for InSAR, we wereable to construct a regional map of the estimated deformation ratein these areasandvalidate the time-series with alocal GPS station. Our preliminary results suggest that PS-InSAR has the ability to capture the local and regional deformation patterns, although further workis needed to compensate formore complexatmospheric effects, estimate error margins,and integrate ourresults intomodels of sea-level change that can be used local stakeholders

Stacey A Huang↗

Accuracy of first-principles interatomic interactions and predictions of ferroelectric phase transitions in perovskite oxides: Energy functional and effective Hamiltonian

While first-principles density functional theory (DFT)-based models have been effective in capturing the physics of ferroelectric phase transitions in BaTiO 3 , PbTiO 3 , and KNbO 3 , quantitative estimates of the transition temperatures (T C ) have errors that are believed to originate from the errors in estimating lattice constants obtained within the local density approximation (LDA) and generalized gradient approximation (GGA) of DFT. The recently developed strongly constrained and appropriately normed (SCAN) meta-GGA functional has been shown to be quite accurate in the estimation of lattice constants. Here, we present a quantitative analysis of the estimates of ferroelectric ground-state properties of eight perovskite oxides and transition temperatures of BaTiO 3 , PbTiO 3 , and KNbO 3 obtained with molecular dynamics simulations using an effective Hamiltonian derived from the SCAN meta-GGA-based DFT. Relative to LDA, we find an improvement in the estimates of T C , which arises from the changes in the calculated strain-phonon, anharmonic coupling constants, and strength of ferroelectric instabilities, i.e., frequencies of the soft modes. We also assess the errors in T C originating from approximately integrating out the high-energy phonons during construction of the model Hamiltonian through estimates of the effects of fourth-order couplings between the soft mode and higher-energy modes of BaTiO 3 , PbTiO 3 , and KNbO 3 . We find that inclusion of these anharmonic couplings results in deeper double-well energy functions of ferroelectric distortions and further improvement in the estimates of transition temperatures. Consistently improved estimates of lattice constants and transition temperatures with the SCAN meta-GGA calculations augur well for their use in simulations of superlattices or heterostructures of perovskite oxides, in which the effects of lattice matching are critical.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A comparison of two position estimate algorithms that use ILS localizer and DME information. Simulation and flight test results

Simulation and flight tests were conducted to compare the accuracy of two algorithms designed to compute a position estimate with an airborne navigation computer. Both algorithms used ILS localizer and DME radio signals to compute a position difference vector to be used as an input to the navigation computer position estimate filter. The results of these tests show that the position estimate accuracy and response to artificially induced errors are improved when the position estimate is computed by an algorithm that geometrically combines DME and ILS localizer information to form a single component of error rather than by an algorithm that produces two independent components of error, one from a DMD input and the other from the ILS localizer input.

Knox, C. E.↗

Local position-space two-nucleon potentials from leading to fourth order of chiral effective field theory

We present local, position-space chiral NN potentials through four orders of chiral effective field theory ranging from leading order (LO) to next-to-next-to-next-to-leading order (N 3 LO, fourth order) of the Δ-less version of the theory. The long-range parts of these potentials are fixed by the very accurate πN LECs as determined in the Roy-Steiner equations analysis. At the highest order (N 3 LO), the NN data below 190 MeV laboratory energy are reproduced with the respectable χ 2 /datum of 1.45. A comparison of the N 3 LO potential with the phenomenological Argonne v 18 (AV18) potential reveals substantial agreement between the two potentials in the intermediate range ruled by chiral symmetry, thus, providing a chiral underpinning for the phenomenological AV18 potential. Our chiral NN potentials may serve as a solid basis for systematic ab initio calculations of nuclear structure and reactions that allow for a comprehensive error analysis. In particular, the order by order development of the potentials will make possible a reliable determination of the truncation error at each order. Our new family of local position-space potentials differs from existing potentials of this kind by a weaker tensor force as reflected in relatively low D-state probabilities of the deuteron (P D ≲ 4.0 % for our N 3 LO potentials) and predictions for the triton binding energy above 8.00 MeV (from two-body forces alone). As a consequence, our potentials may lead to different predictions when applied to light and intermediate-mass nuclei in ab initio calculations and, potentially, help solve some of the outstanding problems in microscopic nuclear structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Urban Air Quality Management at Low-Cost Using Micro Air Sensors: A Case Study From Accra, Ghana

Urban air quality management is dependent on the availability of local air pollution data. In many major urban centers of Africa, there is limited to non-existent information on air quality. This is gradually changing in part due to the increasing use of micro air sensors which have the potential to enable the generation of ground-based air quality data at fine scales for understanding local emission trends. Regional literature on the application of the high-resolution data for emission source identification in this region is limited. In this study a micro air sensor was co-located at the Physics Department, University of Ghana with a reference grade instrument to evaluate its performance for estimating PM2.5 pollution accurately at fine scales and the value of this data in identification of local sources and their behavior over time. For this study 15 weeks of data at hourly resolution with approximately 2500 data pairs are generated and analyzed (June 01, 2023, to September 15, 2023). For this time period a coefficient of determination (r 2 ) of 0.83 was generated with a mean absolute error (MAE) of 5.44 μgm -3 between the pre local calibration micro air sensor (i.e. out of box) and the reference-grade instrument. Following currently accepted best practice methods (see e.g., PAS4023) a domain specific (i.e. local) calibration factor was generated using a multi-linear regression model and when this factor is applied to the micro air sensor data, a reduction i.e., improvement in MAE to 1.43 μgm -3 was found. Daily variation was calculated, a receptor model was applied, and time series plots as a function of wind direction were generated, including PM2.5/PM10 ratio scatter and count plots to explore the utility of this observational approach for local source identification. The 3 data sets were compared (out of box, domain calibrated and reference-grade) and it was found that although there were variations in the data reported, source areas highlighted based on these data were similar, with input from local sources such as traffic emissions and biomass burning. As the temporal resolution of observational data associated with these micro air sensors is higher than for reference grade instruments (primarily due to costs and logistics limitations), they have the potential to provide insight into the complex, often hyper localized sources associated with urban areas, such as those found in major African cities.

Source apportionment↗

SU-E-CAMPUS-J-05: Quantitative Investigation of Random and Systematic Uncertainties From Hardware and Software Components in the Frameless 6DBrainLAB ExacTrac System

Purpose: To evaluate setup accuracy and quantify individual systematic and random errors for the various hardware and software components of the frameless 6D-BrainLAB ExacTrac system. Methods: 35 patients with cranial lesions, some with multiple isocenters (50 total lesions treated in 1, 3, 5 fractions), were investigated. All patients were simulated with a rigid head-and-neck mask and the BrainLAB localizer. CT images were transferred to the IPLAN treatment planning system where optimized plans were generated using stereotactic reference frame based on the localizer. The patients were setup initially with infrared (IR) positioning ExacTrac system. Stereoscopic X-ray images (XC: X-ray Correction) were registered to their corresponding digitally-reconstructed-radiographs, based on bony anatomy matching, to calculate 6D-translational and rotational (Lateral, Longitudinal, Vertical, Pitch, Roll, Yaw) shifts. XC combines systematic errors of the mask, localizer, image registration, frame, and IR. If shifts were below tolerance (0.7 mm translational and 1 degree rotational), treatment was initiated; otherwise corrections were applied and additional X-rays were acquired to verify patient position (XV: X-ray Verification). Statistical analysis was used to extract systematic and random errors of the different components of the 6D-ExacTrac system and evaluate the cumulative setup accuracy. Results: Mask systematic errors (translational; rotational) were the largest and varied from one patient to another in the range (−15 to 4mm; −2.5 to 2.5degree) obtained from mean of XC for each patient. Setup uncertainty in IR positioning (0.97,2.47,1.62mm;0.65,0.84,0.96degree) was extracted from standard-deviation of XC. Combined systematic errors of the frame and localizer (0.32,−0.42,−1.21mm; −0.27,0.34,0.26degree) was extracted from mean of means of XC distributions. Final patient setup uncertainty was obtained from the standard deviations of XV (0.57,0.77,0.67mm,0.39,0.35,0.30degree). Conclusion: Statistical analysis was used to calculate cumulative and individual systematic errors from the different hardware and software components of the 6D-ExacTrac-system. Patients were treated with cumulative errors (<1mm,<1degree) with XV image guidance.

60 APPLIED LIFE SCIENCES↗

STUDY OF CALIBRATION OF SOLAR RADIO SPECTROMETERS AND THE QUIET-SUN RADIO EMISSION

This work presents a systematic investigation of the influence of weather conditions on the calibration errors by using Gaussian fitness, least chi-square linear fitness, and wavelet transform to analyze the calibration coefficients from observations of the Chinese Solar Broadband Radio Spectrometers (at frequency bands of 1.0–2.0 GHz, 2.6–3.8 GHz, and 5.2–7.6 GHz) during 1997–2007. We found that calibration coefficients are influenced by the local air temperature. Considering the temperature correction, the calibration error will reduce by about 10%–20% at 2800 MHz. Based on the above investigation and the calibration corrections, we further study the radio emission of the quiet Sun by using an appropriate hybrid model of the quiet-Sun atmosphere. The results indicate that the numerical flux of the hybrid model is much closer to the observation flux than that of other ones.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of Immobilization on Intrafraction Motion for Spine Stereotactic Body Radiotherapy Using Cone Beam Computed Tomography

Purpose: Spine stereotactic body radiotherapy (SBRT) involves tight planning margins and steep dose gradients to the surrounding organs at risk (OAR). This study aimed to assess intrafraction motion using cone beam computed tomography (CBCT) for spine SBRT patients treated using three immobilization devices. Methods and Materials: Setup accuracy using CBCT was retrospectively analyzed for 102 treated spinal metastases in 84 patients. Thoracic and lumbar spine patients were immobilized with either an evacuated cushion (EC, n = 24) or a semirigid vacuum body fixation (BF, n = 60). For cases treated at cervical/upper thoracic (thoracic [T]1-T3) vertebrae, a thermoplastic S-frame (SF) mask (n = 18) was used. Patient setup was corrected by using bony anatomy image registration and couch translations only (no rotation corrections) with shifts confirmed on verification CBCTs. Repeat imaging was performed mid- and post-treatment. Patient translational and rotational positioning data were recorded to calculate means, standard deviations (SD), and corresponding margins {+-} 2 SD for residual setup errors and intrafraction motion. Results: A total of 355 localizations, 333 verifications, and 248 mid- and 280 post-treatment CBCTs were analyzed. Residual translations and rotations after couch corrections (verification scans) were similar for all immobilization systems, with SDs of 0.6 to 0.9 mm in any direction and 0.9 Degree-Sign to 1.6 Degree-Sign , respectively. Margins to encompass residual setup errors after couch corrections were within 2 mm. Including intrafraction motion, as measured on post-treatment CBCTs, SDs for total setup error in the left-right, cranial-caudal, and anterior-posterior directions were 1.3, 1.2, and 1.0 mm for EC; 0.9, 0.7, and 0.9 mm for BF; and 1.3, 0.9, and 1.1 mm for SF, respectively. The calculated margins required to encompass total setup error increased to 3 mm for EC and SF and remained within 2 mm for BF. Conclusion: Following image guidance, residual setup errors for spine SBRT were similar across three immobilization systems. The BF device resulted in the least amount of intrafraction motion, and based on this device, we justify a 2-mm margin for the planning OAR and target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated selection of the local potential for transferable pseudopotentials

We develop an automated procedure to select the local potential of a separable pseudopotential that minimizes transferability errors for the isolated atom, and we show that this optimization leads to significant improvements in the accuracy of predicted solid-state properties. We present pseudopotentials for Y, In, and Sn. For these pseudopotentials, our method reduces solid-state errors by 88% on average, as measured by the Δ-factor test. These pseudopotentials are constructed in the Kleinman-Bylander form; however, our method is applicable to all separable pseudopotentials, such as ONCV pseudopotentials. Here, we perform plane-wave convergence tests according to SSSP standards and show that the modifications to the local potential leave plane-wave convergence unchanged.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing many-body localization on a noisy quantum computer

A disordered quantum system of interacting particles exhibits localized behavior when the disorder is large compared to the interaction strength. Studying this phenomenon on a quantum computer with no, or limited, error correction is challenging because even weak coupling to a thermal environment destroys most signatures of localization. Fortunately, spectral functions of local operators are known to contain features that can survive the presence of noise. In these spectra, discrete peaks and a soft gap at low frequencies compared to the thermal phase indicate localization. Here, we present the computation of spectral functions on a trapped-ion quantum computer for a one-dimensional Heisenberg model with disorder. Further, we design an error-mitigation technique which is effective at removing the noise from the measurement allowing clear signatures of localization to emerge as the disorder increases. Furthermore, we show that spectral functions can serve as a robust and scalable diagnostic of many-body localization on current and future generations of quantum computers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring Interfractional and Intrafractional Motion With Cone Beam Computed Tomography and an Optical Localization System for Lower Extremity Soft Tissue Sarcoma Patients Treated With Preoperative Intensity-Modulated Radiation Therapy

Purpose: To evaluate inter- and intrafractional motion and rotational error for lower extremity soft tissue sarcoma patients by using cone beam computed tomography (CBCT) and an optical localization system. Methods and Materials: Thirty-one immobilized patients received CBCT image-guided intensity-modulated radiation therapy. Setup deviations of >3 mm from the planned isocenter were corrected. A second CBCT acquired before treatment delivery was registered to the planning CT to estimate interfractional setup error retrospectively. Interfractional error and rotational error were calculated in the left-right (LR), superoinferior (SI), and anteroposterior (AP) dimensions. Intrafractional motion was assessed by calculating the maximum relative displacement of optical localization system reflective markers placed on the patient's surface, combined with pre- and postfraction CBCT performed for 17 of the 31 patients once per week. The overall systematic error (SE) and random error (RE) were calculated for the interfractional and intrafractional motion for planning target volume margin calculation. Results: The standard deviation (SD) of the interfractional RE was 1.9 mm LR, 2.1 mm SI, and 1.8 mm AP, and the SE SD was 0.6 mm, 1.2 mm, and 0.7 mm in each dimension, respectively. The overall rotation (inter- and intrafractional) had an RE SD of 0.8{sup o} LR, 1.7{sup o} SI, and 0.7{sup o} AP and an SE SD of 1.1{sup o} LR, 1.3{sup o} SI, and 0.3{sup o} AP. The SD of the overall intrafractional RE was 1.6 mm LR, 1.6 mm SI, and 1.4 mm AP, and the SE SD was 0.7 mm AP, 0.6 mm SI, and 0.6 mm AP. Conclusions: A uniform 5-mm planning target volume margin was quantified for lower extremity soft tissue sarcoma patients and has been implemented clinically for image-guided intensity-modulated radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗