Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

WE-AB-207A-01: BEST IN PHYSICS (IMAGING): High-Resolution Cone-Beam CT of the Extremities and Cancellous Bone Architecture with a CMOS Detector

Purpose: Extremity cone-beam CT (CBCT) with an amorphous silicon (aSi) flat-panel detector (FPD) provides low-dose volumetric imaging with high spatial resolution. We investigate the performance of the newer complementary metal-oxide semiconductor (CMOS) detectors to enhance resolution of extremities CBCT to ∼0.1 mm, enabling morphological analysis of trabecular bone. Quantitative in-vivo imaging of bone microarchitecture could present an important advance for osteoporosis and osteoarthritis diagnosis and therapy assessment. Methods: Cascaded systems models of CMOS- and FPD-based extremities CBCT were implemented. Performance was compared for a range of pixel sizes (0.05–0.4 mm), focal spot sizes (0.3–0.6 FS), and x-ray techniques (0.05–0.8 mAs/projection) using detectability of high-, low-, and all-frequency tasks for a nonprewhitening observer. Test-bench implementation of CMOS-based extremity CBCT involved a Teledyne DALSA Xineos3030HR detector with 0.099 mm pixels and a compact rotating anode x-ray source with 0.3 FS (IMD RTM37). Metrics of bone morphology obtained using CMOS-based CBCT were compared in cadaveric specimens to FPD-based system using a Varian PaxScan4030 (0.194 mm pixels). Results: Finer pixel size and reduced electronic noise for CMOS (136 e compared to 2000 e for FPD) resulted in ∼1.9× increase in detectability for high-frequency tasks and ∼1.1× increase for all-frequency tasks. Incorporation of the new x-ray source with reduced focal spot size (0.3 FS vs. 0.5 FS used on current extremities CBCT) improved detectability for CMOS-based CBCT by ∼1.7× for high-frequency tasks. Compared to FPD CBCT, the CMOS detector yielded improved agreement with micro-CT in measurements of trabecular thickness (∼1.7× reduction in relative error), bone volume (∼1.5× reduction), and trabecular spacing (∼3.5× reduction). Conclusion: Imaging performance modelling and experimentation indicate substantial improvements for high-frequency imaging tasks through adoption of the CMOS detector and small FS x-ray source, motivating the use of these components in a new system for quantitative in-vivo imaging of trabecular bone. Financial Support: US NIH grant R01EB018896. Qian Cao is a Howard Hughes Medical Institute International Student Research Fellow. Disclosures: W Zbijewski, J Siewerdsen and A Sisniega receive research funding from Carestream Health.

60 APPLIED LIFE SCIENCES↗

Comparison of Spatial Discretization Methods for Solving the S N Equations Using a Three-Dimensional Method of Manufactured Solutions Benchmark Suite with Escalating Order of Nonsmoothness

For this study, a comparison of the accuracy and computational efficiency of spatial discretization methods of the three-dimensional S N equations is conducted, including discontinuous Galerkin finite element methods, the arbitrarily high-order transport method of nodal type (AHOTN), the linear-linear method, the linear-nodal (LN) method, and the higher-order diamond difference method. For this purpose, we have developed a suite of method of manufactured solutions benchmarks that provides an exact solution of the S N equations even in the presence of scattering. Most importantly, our benchmark suite permits the user to set an arbitrary level of smoothness of the exact solution across the singular characteristics. Our study focuses on the computational efficiency of the considered spatial discretization methods. Numerical results indicate that the best-performing method depends on the norm used to measure the discretization error. We employ discrete Lp norms and integral error norms in this work. For configurations with continuous exact angular flux, high-order AHOTNs perform best under L p error norms, while the LN method performs best when measured by integral error norms. Lastly, when the angular flux is discontinuous, a new singular-characteristic tracking method for three-dimensional geometries performs best among the considered methods.

97 MATHEMATICS AND COMPUTING↗

Hybrid Enrichment Assay Methods for a UF6 Cylinder Verification Station: FY10 Progress Report

Pacific Northwest National Laboratory (PNNL) is developing the concept of an automated UF6 cylinder verification station that would be located at key measurement points to positively identify each cylinder, measure its mass and enrichment, store the collected data in a secure database, and maintain continuity of knowledge on measured cylinders until the arrival of International Atomic Energy Agency (IAEA) inspectors. At the center of this unattended system is a hybrid enrichment assay technique that combines the traditional enrichment-meter method (based on the 186 keV peak from 235U) with non-traditional neutron-induced high-energy gamma-ray signatures (spawned primarily by 234U alpha emissions and 19F(alpha, neutron) reactions). Previous work by PNNL provided proof-of-principle for the non-traditional signatures to support accurate, full-volume interrogation of the cylinder enrichment, thereby reducing the systematic uncertainties in enrichment assay due to UF6 heterogeneity and providing greater sensitivity to material substitution scenarios. The work described here builds on that preliminary evaluation of the non-traditional signatures, but focuses on a prototype field system utilizing NaI(Tl) and LaBr3(Ce) spectrometers, and enrichment analysis algorithms that integrate the traditional and non-traditional signatures. Results for the assay of Type-30B cylinders ranging from 0.2 to 4.95 wt% 235U, at an AREVA fuel fabrication plant in Richland, WA, are described for the following enrichment analysis methods: 1) traditional enrichment meter signature (186 keV peak) as calculated using a square-wave convolute (SWC) algorithm; 2) non-traditional high-energy gamma-ray signature that provides neutron detection without neutron detectors and 3) hybrid algorithm that merges the traditional and non-traditional signatures. Uncertainties for each method, relative to the declared enrichment for each cylinder, are calculated and compared to the uncertainties from an attended HPGe verification station at AREVA, and the IAEA’s uncertainty target values for feed, tail and product cylinders. A summary of the major findings from the field measurements and subsequent analysis follows: • Traditional enrichment-meter assay using specially collimated NaI spectrometers and a Square-Wave-Convolute algorithm can achieve uncertainties comparable to HPGe and LaBr for product, natural and depleted cylinders. • Non-traditional signatures measured using NaI spectrometers enable interrogation of the entire cylinder volume and accurate measurement of absolute 235U mass in product, natural and depleted cylinders. • A hybrid enrichment assay method can achieve lower uncertainties than either the traditional or non-traditional methods acting independently because there is a low degree of correlation in the systematic errors of the two individual methods (wall thickness variation and 234U/235U variation, respectively). This work has indicated that the hybrid NDA method has the potential to serve as the foundation for an unattended cylinder verification station. When compared to today’s handheld cylinder-verification approach, such a station would have the following advantages: 1) improved enrichment assay accuracy for product, tail and feed cylinders; 2) full-volume assay of absolute 235U mass; 3) assay of minor isotopes (234U and 232U) important to verification of feedstock origin; single instrumentation design for both Type 30B and Type 48 cylinders; and 4) substantial reduction in the inspector manpower associated with cylinder verification.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear Data and Cross Section Testing Using ENDF/B-VIII.0

With the release of the Evaluated Nuclear Data File (ENDF)/B-VIII.0 library, nuclear criticality safety practitioners and engineers have access to the latest cross section sets available for their analyses. However, these cross sections must be rigorously tested and validated to ensure that the nuclear data are responsive to the needs of the individuals responsible for developing, implementing, and maintaining computational tools for criticality safety applications. Thus, the ENDF/B-VIII.0 library is tested and validated with a large collection of experiments that were vetted by the International Criticality Safety Benchmark Evaluation Project and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments. A selection of benchmark experiments for use within the criticality safety community were prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID), which is maintained by the Nuclear Energy and Fuel Cycle Division at Oak Ridge National Laboratory. The performance of the ENDF/B-VIII.0 library is assessed by using VALID models of benchmark experiments with the beta 12 version of SCALE 6.3 KENO V.a and KENO-VI Monte Carlo codes. The performance is compared with the results obtained from with the ENDF/B-VII.1 library. This report considers multigroup (MG) and continuous energy (CE) formats of the ENDF/B-VIII.0 and -VII.1 libraries. The benchmark experiments within VALID that validate the ENDF/B-VIII.0 library cover 15 broad system categories by using a range of fissile materials, uranium enrichments, plutonium isotopic vectors, and mixed uranium/plutonium systems. These forms are represented as metals, solutions, or various arrays of rods or plates that cover a variety of neutron energy spectra: thermal, fast, mixed, and intermediate. Over 600 cases were considered for use with the KENO V.a and KENO-VI codes with the ENDF/B-VIII.0 library. The results of the Monte Carlo comparison of ENDF/B-VIII.0 to ENDF/B-VII.1 with both KENO V.a and KENO-VI indicate that there is a less than 0.53% Δk difference between the bias of calculated k eff from the expected values. The CE ENDF/B-VIII.0 library results in smaller magnitude biases than the ENDF/B-VII.1 data for HEU-MET-FAST, HEU-SOL-THERM, IEU-MET-FAST, LEU-SOL-THERM, PU-SOL-THERM, and U233-MET-FAST systems, while the MG results yielded smaller magnitude biases for HEU-MET-FAST, HEU-SOL-THERM, IEU-MET-FAST, LEU-COMP-THERM, LEU-SOL THERM, MIX-COMP-FAST, and U233-MET-FAST systems. Most notable are the adjustments to the plutonium and 233 U cross section data, which has resulted in noticeably lower biases in the ENDF/B VIII.0 results for the mixed, plutonium, and 233 U systems. Results of the sensitivity data file comparison generated from TSUNAMI-3D for selected VALID cases for the ENDF/B-VIII.0 library indicate a very high level of agreement with correlation coefficients of the effect of nuclear data uncertainty on k eff (the c k integral parameter) all above 0.99. This indicates that cases with the ENDF/B-VIII.0 library would see very similar responses to any nuclear data errors or change as those with the ENDF/B-VII.1 library.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulation Analysis of Mode Hopping Impacts on OFDR Sensing Performance

This article examines the impacts of mode hopping on the sensing performance of optical frequency domain reflectometry (OFDR) and explores the potential for developing economical OFDR interrogators employing low-cost distributed feedback (DFB) lasers. By conducting numerical simulations, this study reveals that mode hopping has minimal effects on distance sensing measurements in free space due to the limited duration of beat interference signal at the incorrect frequency within the coherence length. Additionally, the simulations indicate that mode hopping only slightly affects the distributed strain sensing of OFDR, resulting in an error range of less than ±1µε when 100µε is applied to the sensing fiber. These findings highlight the potential of using low-cost DFB lasers with a 1-nm wavelength sweep range and a 1-MHz linewidth as tunable laser sources in OFDR while maintaining reliable and accurate sensing performance.

Wang, Qirui (ORCID:0000000336532984)↗

A Double-line M-dwarf Eclipsing Binary from CSS × SDSS

Eclipsing binaries offer a unique opportunity to determine basic stellar properties. With the advent of wide-field camera and all-sky time-domain surveys, thousands of eclipsing binaries have been charted via light curve classification, yet their fundamental properties remain unexplored mainly due to the extensive efforts needed for spectroscopic follow-ups. In this paper, we present the discovery of a short-period ( P = 0.313 day), double-lined M-dwarf eclipsing binary, CSSJ114804.3+255132/SDSSJ114804.35+255132.6, by cross-matching binary light curves from the Catalina Sky Survey and spectroscopically classified M dwarfs from the Sloan Digital Sky Survey. We obtain follow-up spectra using the Gemini telescope, enabling us to determine the mass, radius, and temperature of the primary and secondary component to be M {sub 1} = 0.47 ± 0.03(statistic) ± 0.03(systematic) M {sub ⊙}, M {sub 2} = 0.46 ± 0.03(statistic) ± 0.03(systematic) M {sub ⊙}, R {sub 1} = 0.52 ± 0.08(statistic) ± 0.07(systematic) R {sub ⊙}, R {sub 2} =0.60 ± 0.08(statistic) ± 0.08(systematic) R {sub ⊙}, T {sub 1} = 3560 ± 100 K, and T {sub 2} = 3040 ± 100 K, respectively. The systematic error was estimated using the difference between eccentric and non-eccentric fits. Our analysis also indicates that there is definitively third-light contamination (66%) in the CSS photometry. The secondary star seems inflated, probably due to tidal locking of the close secondary companion, which is common for very short-period binary systems. Future spectroscopic observations with high resolution will narrow down the uncertainties of stellar parameters for both components, rendering this system as a benchmark for studying fundamental properties of M dwarfs.

79 ASTRONOMY AND ASTROPHYSICS↗

Validating precision estimates in horizontal wind measurements from a Doppler lidar

Results from a recent field campaign are used to assess the accuracy of wind speed and direction precision estimates produced by a Doppler lidar wind retrieval algorithm. The algorithm, which is based on the traditional velocity-azimuth-display (VAD) technique, estimates the wind speed and direction measurement precision using standard error propagation techniques, assuming the input data (i.e., radial velocities) to be contaminated by random, zero-mean, errors. For this study, the lidar was configured to execute an 8-beam plan-position-indicator (PPI) scan once every 12 min during the 6-week deployment period. Several wind retrieval trials were conducted using different schemes for estimating the precision in the radial velocity measurements. Here, the resulting wind speed and direction precision estimates were compared to differences in wind speed and direction between the VAD algorithm and sonic anemometer measurements taken on a nearby 300 m tower.

17 WIND ENERGY↗

Improving Computational Efficiency of Mechanical Finite Element Method Simulations for PV Modules: Preprint

In this work we have elucidated the trade off between structural mechanics FEM model accuracy and computation time by employing lower fidelity viscoelastic models. Results indicate that computation time can easily be cut in half while only expecting a potential maximum error of 10 % by considering lower fidelity models. A novel approach to produce the Prony Series fit for viscoelastic characterization has also been presented. Employing this approach, we were able to achieve a further 10 % reduction in computation time without further sacrificing simulation accuracy.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Towards a neutron multiplicity measurement with the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26 ton Gadolinium (Gd)-loaded water Cherenkov detector located on the Booster Neutrino Beam line at Fermilab. Its main goals are the measurement of the neutron multiplicity in neutrino-nucleus interactions as well as the cross-section of Charged Current Quasi-Elastic (CCQE) neutrino interactions on water. Besides the physics goals, the experiment also aims to be a testbed for new technologies such as Large Area Picosecond Photodetectors (LAPPDs) and Water-based Liquid Scintillators (WbLS). This thesis presents a preliminary measurement of the neutron multiplicity with {ANNIE}, using an analysis conducted on a fraction of the 2021 beam year. As preparatory measures, the efficiency of ANNIE's Front Muon Veto (FMV) was determined to be {$\bar{\varepsilon}_{\mathrm{FMV}} = (95.6 \pm 1.6)\%$} while the average efficiency for active scintillator paddles in the Muon Range Detector (MRD) was found to be {$\bar{\varepsilon}_ {\mathrm{MRD}} = (92.1 \pm 7.9)\%$}. Furthermore, the simulation framework used for ANNIE was validated and adapted to reproduce the experimental data by comparing the detector response for samples of Michel electrons, Americium Beryllium neutrons, and through-going muons. The analysis finds average neutron yields of {$\bar{n}_{\mathrm{data}} (\mathrm{beam}) = (0.272 \pm 0.010_{\mathrm{stat}})$} for an inclusive set of all identified muon neutrino candidates and {$\bar{n}_{\mathrm{data}} (\mathrm{beam,FV}) = (0.287 \pm 0.044_{\mathrm{stat}})$ for interactions which happened inside of the Fiducial Volume of ANNIE, which was optimized to increase the neutron detection acceptance. The presented neutron multiplicity values represent the number of detected neutrons after all event selection cuts and are not yet corrected for the neutron detection efficiency. An equivalent analysis on a simulated beam sample predicts neutron yields of $\bar{n}_{\mathrm{MC}}(\mathrm{beam}) = (0.515 \pm 0.0 07_{\mathrm{stat}})$ and $\bar{n}_{\mathrm{MC}}(\mathrm{beam,FV}) = (0.627 \pm 0.031_{\mathrm{stat}})$, indicating that the models tend to overpredict the number of neutrons produced in such interactions. Systematic errors have been briefly considered to contribute {$\sigma_{\mathrm{sys,FMV}} \sim 0.01\,$neutrons/$\nu$-interaction} due to the slight FMV inefficiency and {$\sigma_{\mathrm{sys,n}} \sim 0.05\,$neutrons/$\nu$-interaction} due to the neutron detection efficiency. Simulation studies further highlighted the importance of neutron detection in Diffuse Supernova Background (DSNB) searches. A combination of neutron tagging and Convolutional Neural Networks was found to reduce the most relevant Neutral Current Quasi-Elastic (NCQE) interaction background below the signal level, achieving a Signal-to-Background ratio of 4:1. In a further study, we investigated the positive impact of a deployment of a WbLS target on the energy reconstruction in ANNIE. WbLS provides a scintillation signal from hadronic recoils in addition to the charged lepton that can be included in neutrino energy reconstruction. It was found that a deployed WbLS volume in ANNIE improves the neutrino energy reconstruction from 14\% to 12\%, with the potential of going beyond this if more sophisticated reconstruction algorithms are developed in the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Age estimation in forensic sciences: Application of combined aspartic acid racemization and radiocarbon analysis

Age determination of unknown human bodies is important in the setting of a crime investigation or a mass disaster, since the age at death, birth date and year of death, as well as gender, can guide investigators to the correct identity among a large number of possible matches. Traditional morphological methods used by anthropologists to determine age are often imprecise, whereas chemical analysis of tooth dentin, such as aspartic acid racemization has shown reproducible and more precise results. In this paper we analyze teeth from Swedish individuals using both aspartic acid racemization and radiocarbon methodologies. The rationale behind using radiocarbon analysis is that above-ground testing of nuclear weapons during the cold war (1955-1963) caused an extreme increase in global levels of carbon-14 ({sup 14}C) which have been carefully recorded over time. Forty-four teeth from 41 individuals were analyzed using aspartic acid racemization analysis of tooth crown dentin or radiocarbon analysis of enamel and ten of these were split and subjected to both radiocarbon and racemization analysis. Combined analysis showed that the two methods correlated well (R2=0.66, p < 0.05). Radiocarbon analysis showed an excellent precision with an overall absolute error of 0.6 {+-} 04 years. Aspartic acid racemization also showed a good precision with an overall absolute error of 5.4 {+-} 4.2 years. Whereas radiocarbon analysis gives an estimated year of birth, racemization analysis indicates the chronological age of the individual at the time of death. We show how these methods in combination can also assist in the estimation of date of death of an unidentified victim. This strategy can be of significant assistance in forensic casework involving dead victim identification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Organic contamination detection for isotopic analysis of water by laser spectroscopy

Hydrogen and oxygen stable isotope ratios (δ 2 H, δ 17 O, and δ 18 O values) are commonly used tracers of water. These ratios can be measured by isotope ratio infrared spectroscopy (IRIS). However, IRIS approaches are prone to errors induced by organic compounds present in plant, soil, and natural water samples. A novel approach using 17 O-excess values has shown promise for flagging spectrally contaminated plant samples during IRIS analysis. A systematic assessment of this flagging system is needed to prove it useful. Errors induced by methanol and ethanol water mixtures on measured IRIS and isotope ratio mass spectrometry (IRMS) results were evaluated. For IRIS analyses both liquid- and vapour-mode (via direct vapour equilibration) methods are used. The δ 2 H, δ 17 O, and δ 18 O values were measured and compared with known reference values to determine the errors induced by methanol and ethanol contamination. In addition, the 17 O-excess contamination detection approach was tested. This is a post-processing detection tool for both liquid and vapour IRIS triple-isotope analyses, utilizing calculated 17 O-excess values to flag contaminated samples. Organic contamination induced significant errors in IRIS results, not seen in IRMS results. Methanol caused larger errors than ethanol. Results from vapour-IRIS analyses had larger errors than those from liquid-IRIS analyses. The 17 O-excess approach identified methanol driven error in liquid- and vapour-mode IRIS samples at levels where isotope results became unacceptably erroneous. For ethanol contaminated samples, a mix of erroneous and correct flagging occurred with the 17 O-excess method. Here our results indicate that methanol is the more problematic contaminant for data corruption. The 17 O-excess method was therefore useful for data quality control. Organic contamination caused significant errors in IRIS stable isotope results. These errors were larger during vapour analyses than during liquid IRIS analyses, and larger for methanol than ethanol contamination. The 17 O-excess method is highly sensitive for detecting narrowband (methanol) contamination error in vapour and liquid analysis modes in IRIS.

60 APPLIED LIFE SCIENCES↗

SDSS-II: Determination of shape and color parameter coefficients for SALT-II fit model

In this study we look at the SALT-II model of Type IA supernova analysis, which determines the distance moduli based on the known absolute standard candle magnitude of the Type IA supernovae. We take a look at the determination of the shape and color parameter coefficients, {alpha} and {beta} respectively, in the SALT-II model with the intrinsic error that is determined from the data. Using the SNANA software package provided for the analysis of Type IA supernovae, we use a standard Monte Carlo simulation to generate data with known parameters to use as a tool for analyzing the trends in the model based on certain assumptions about the intrinsic error. In order to find the best standard candle model, we try to minimize the residuals on the Hubble diagram by calculating the correct shape and color parameter coefficients. We can estimate the magnitude of the intrinsic errors required to obtain results with {chi}{sup 2}/degree of freedom = 1. We can use the simulation to estimate the amount of color smearing as indicated by the data for our model. We find that the color smearing model works as a general estimate of the color smearing, and that we are able to use the RMS distribution in the variables as one method of estimating the correct intrinsic errors needed by the data to obtain the correct results for {alpha} and {beta}. We then apply the resultant intrinsic error matrix to the real data and show our results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-resolution microcalorimeter detectors as a tool in the future of nuclear safeguards

New measurements are presented from the LANL-NIST microcalorimeter array for two standard plutonium sources. The results demonstrate substantially smaller error bars obtained from the spectral analysis program FRAM. Some areas of improvement to the analysis technique have been identified, indicating that the micro calorimeter results can be improved upon. These results support the viability of a device for performing real nuclear safeguards measurements in the near future. The challenge of providing reliably accurate and precise data is a critical component of any safeguards initiative. In the realm of nuclear safeguards, this is an especially daunting task since inaccurate and/or imprecise data could have very serious international consequences. As such, there is a constant drive within the community to establish better measurement and analysis techniques in order to further reduce the associated errors and uncertainties. Even with todays state of the art equipment, measurement uncertainties can extend to several significant quantities worth of material over a relatively modest period of time. Furthermore, there is a strong desire for improved nondestructive analysis techniques in order to reduce both the cost, turnover rate, and inconvenience of destructive analyses. One promising new technology that may help to realize these goals is that of gamma-ray microcalorimeter detectors. The hallmark quality of this new technique is the ability to achieve energy resolution nearly an order of magnitude better than typical planar high-purity germanium (HPGe) detectors. Such an improvement may help reduce uncertainties associated with, for instance, plutonium isotopics or uranium enrichment measurements. This may, in turn, help to reduce uncertainties in total plutonium and/or uranium content in a given sample without the need for destructive analysis. In this paper, we will describe this new detector technology as well as some recent measurements carried out with the LANL-NIST gamma-ray microcalorimeter ({micro}cal) array. Discussion will focus on the capabilities of this technology as well as the progress toward a practical measurement device.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Copper K-shell emission cross sections for laser–solid experiments

Published measurements and models of the cross section for electrons causing K-shell emission from copper are reviewed to find a suitable expression to use when analyzing K{sub α}-emission measurements in laser–solid experiments at peak intensities above 10{sup 18} W/cm{sup 2}. Few measurements exist in the 0.1- to 10-MeV electron energy range currently of interest, leaving a number of possible suitable models that are summarized here with a number of typing errors corrected. Two different limiting forms for the cross section at relativistic energies are used, and existing measurements do not give a clear indication as to which is correct. Comparison with the limiting form of electron stopping power indicates an alternative relativistic form and also that the density-effect correction will be important in copper above 10 MeV. For data analysis relying on relative K{sub α} emission caused by electrons with energy much greater than the K-shell binding energy, the existing uncertainty in cross sections is unimportant, but it will be a source of uncertainty when using absolute values and for electron energies up to ∼6× the binding energy. K-shell emission caused by photons and protons is also briefly reviewed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quality Control of High-Dose-Rate Brachytherapy: Treatment Delivery Analysis Using Statistical Process Control

Purpose: Statistical process control (SPC) is a quality control method used to ensure that a process is well controlled and operates with little variation. This study determined whether SPC was a viable technique for evaluating the proper operation of a high-dose-rate (HDR) brachytherapy treatment delivery system. Methods and Materials: A surrogate prostate patient was developed using Vyse ordnance gelatin. A total of 10 metal oxide semiconductor field-effect transistors (MOSFETs) were placed from prostate base to apex. Computed tomography guidance was used to accurately position the first detector in each train at the base. The plan consisted of 12 needles with 129 dwell positions delivering a prescribed peripheral dose of 200 cGy. Sixteen accurate treatment trials were delivered as planned. Subsequently, a number of treatments were delivered with errors introduced, including wrong patient, wrong source calibration, wrong connection sequence, single needle displaced inferiorly 5 mm, and entire implant displaced 2 mm and 4 mm inferiorly. Two process behavior charts (PBC), an individual and a moving range chart, were developed for each dosimeter location. Results: There were 4 false positives resulting from 160 measurements from 16 accurately delivered treatments. For the inaccurately delivered treatments, the PBC indicated that measurements made at the periphery and apex (regions of high-dose gradient) were much more sensitive to treatment delivery errors. All errors introduced were correctly identified by either the individual or the moving range PBC in the apex region. Measurements at the urethra and base were less sensitive to errors. Conclusions: SPC is a viable method for assessing the quality of HDR treatment delivery. Further development is necessary to determine the most effective dose sampling, to ensure reproducible evaluation of treatment delivery accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of 12 DIR algorithms in low-contrast regions for mass and density conserving deformation

Purpose: Deformable image registration (DIR) has become a key tool for adaptive radiotherapy to account for inter- and intrafraction organ deformation. Of contemporary interest, the application to deformable dose accumulation requires accurate deformation even in low contrast regions where dose gradients may exist within near-uniform tissues. One expects high-contrast features to generally be deformed more accurately by DIR algorithms. The authors systematically assess the accuracy of 12 DIR algorithms and quantitatively examine, in particular, low-contrast regions, where accuracy has not previously been established.Methods: This work investigates DIR algorithms in three dimensions using deformable gel (DEFGEL) [U. J. Yeo, M. L. Taylor, L. Dunn, R. L. Smith, T. Kron, and R. D. Franich, “A novel methodology for 3D deformable dosimetry,” Med. Phys. 39, 2203–2213 (2012)], for application to mass- and density-conserving deformations. CT images of DEFGEL phantoms with 16 fiducial markers (FMs) implanted were acquired in deformed and undeformed states for three different representative deformation geometries. Nonrigid image registration was performed using 12 common algorithms in the public domain. The optimum parameter setup was identified for each algorithm and each was tested for deformation accuracy in three scenarios: (I) original images of the DEFGEL with 16 FMs; (II) images with eight of the FMs mathematically erased; and (III) images with all FMs mathematically erased. The deformation vector fields obtained for scenarios II and III were then applied to the original images containing all 16 FMs. The locations of the FMs estimated by the algorithms were compared to actual locations determined by CT imaging. The accuracy of the algorithms was assessed by evaluation of three-dimensional vectors between true marker locations and predicted marker locations.Results: The mean magnitude of 16 error vectors per sample ranged from 0.3 to 3.7, 1.0 to 6.3, and 1.3 to 7.5 mm across algorithms for scenarios I to III, respectively. The greatest accuracy was exhibited by the original Horn and Schunck optical flow algorithm. In this case, for scenario III (erased FMs not contributing to driving the DIR calculation), the mean error was half that of the modified demons algorithm (which exhibited the greatest error), across all deformations. Some algorithms failed to reproduce the geometry at all, while others accurately deformed high contrast features but not low-contrast regions—indicating poor interpolation between landmarks.Conclusions: The accuracy of DIR algorithms was quantitatively evaluated using a tissue equivalent, mass, and density conserving DEFGEL phantom. For the model studied, optical flow algorithms performed better than demons algorithms, with the original Horn and Schunck performing best. The degree of error is influenced more by the magnitude of displacement than the geometric complexity of the deformation. As might be expected, deformation is estimated less accurately for low-contrast regions than for high-contrast features, and the method presented here allows quantitative analysis of the differences. The evaluation of registration accuracy through observation of the same high contrast features that drive the DIR calculation is shown to be circular and hence misleading.

61 RADIATION PROTECTION AND DOSIMETRY↗

Minimizing Grating Slope Errors in the IEX Monochromato at the Advanced Photon Source

The IEX beamline at the APS is currently in the commissioning phase. The energy resolution of the beamline was not meeting original specifications by several orders of magnitude. The monochromator, an in-focus VLS-PGM, is currently configured with a high and a medium-line-density grating. Experimental results indicated that both gratings were contributing to the poor energy resolution and this led to venting the monochromator to investigate. The initial suspicion was that a systematic error had occurred in the ruling process on the VLS gratings, but that proved to not be the case. Instead the problem was isolated to mechanical constraints used to mount the gratings into their respective side-cooled holders. Modifications were made to the holders to eliminate problematic constraints without compromising the rest of the design. Metrology performed on the gratings in the original and modified holders demonstrated a 20-fold improvement in the surface profile error which was consistent with finite element analysis performed in support of the modifications. Two gratings were successfully reinstalled and subsequent measurements with beam show a dramatic improvement in energy resolution.

Fisher, M. V.↗

THE ARAUCARIA PROJECT: FIRST CEPHEID DISTANCE TO THE SCULPTOR GROUP GALAXY NGC 7793 FROM VARIABLES DISCOVERED IN A WIDE-FIELD IMAGING SURVEY

For the first time, we have detected Cepheid variables in the Sculptor Group spiral galaxy NGC 7793. From wide-field images obtained in the optical V and I bands on 56 nights in 2003-2005, we have discovered 17 long-period (24-62 days) Cepheids whose periods and mean magnitudes define tight period-luminosity relations. We use the (V - I) Wesenheit index to determine a reddening-free true distance modulus to NGC 7793 of 27.68 {+-} 0.05 mag (internal error) {+-} 0.08 mag (systematic error). The comparison of the reddened distance moduli in V and I with the one derived from the Wesenheit magnitude indicates that the Cepheids in NGC 7793 are affected by an average total reddening of E(B - V) = 0.08 mag, 0.06 of which is produced inside the host galaxy. As in the earlier Cepheid studies of the Araucaria Project, the reported distance is tied to an assumed LMC distance modulus of 18.50. The quoted systematic uncertainty takes into account effects like blending and possible inhomogeneous filling of the Cepheid instability strip on the derived distance. The reported distance value does not depend on the (unknown) metallicity of the Cepheids according to recent theoretical and empirical results. Our Cepheid distance is shorter, but within the errors consistent with the distance to NGC 7793 determined earlier with the TRGB and Tully-Fisher methods. The NGC 7793 distance of 3.4 Mpc is almost identical to the one our project had found for NGC 247, another spiral member of the Sculptor Group located close to NGC 7793 on the sky. Two other conspicuous spiral galaxies in the Sculptor Group, NGC 55 and NGC 300, are much nearer (1.9 Mpc), confirming the picture of a very elongated structure of the Sculptor Group in the line of sight put forward by Jerjen et al. and others.

79 ASTRONOMY AND ASTROPHYSICS↗