Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Progress in development of tapes and magnets made from Bi-2223 superconductors

Long lengths of (Bi,Pb)2Sr2Ca2Cu3O(x) tapes made by powder-in-tube processing have been wound into coils. Performance of the coils has been measured at temperatures of 4.2 to 77 K, and microstructures have been examined by x-ray diffraction and electron microscopy and then related to superconducting properties. A summary of recent results and an overview of future goals are presented.

Balachandran, U.↗

Radio Emissions Observed by Galileo near Io

The Galileo spacecraft observed spin modulation of radio wave emissions near Io in the frequency range from about 600 kHz to about 1.2 MHz. Assuming transverse EM radiation, we have used the modulation of the high-frequency sweep-frequency receiver signals of the electric dipole antenna over many spins to estimate the plane through the source. The emission has a range of frequencies close to the local upper hybrid frequency of the plasma near Io. We conclude that the emission may be associated with either the plasma torus or magnetic flux tubes in the wake of Io (the Alfven current system). We postulate this emission may be associated with a free-energy source such as density gradients, energetic plasma beams and/or an electron distribution with a temperature anisotropy. All of these free-energy sources are observed or expected in the torus near Io. The observations are the first in the hectometric frequency range that have a source associated with Io or in the Io torus.

Menietti, J. D.↗

Computational Investigation of Helical Traveling Wave Tube Transverse RF Field Forces

In a previous study using a fully three-dimensional (3D) helical slow-wave circuit cold- test model it was found, contrary to classical helical circuit analyses, that transverse FF electric fields have significant amplitudes compared with the longitudinal component. The RF fields obtained using this helical cold-test model have been scaled to correspond to those of an actual TWT. At the output of the tube, RF field forces reach 61%, 26% and 132% for radial, azimuthal and longitudinal components, respectively, compared to radial space charge forces indicating the importance of considering them in the design of electron beam focusing.

Kory, Carol L.↗

UAV-Based L-Band SAR with Precision Flight Path Control

NASA's Jet Propulsion Laboratory is currently implementing a reconfigurable polarimetric L-band synthetic aperture radar (SAR), specifically designed to acquire airborne repeat track interferometric (RTI) SAR data, also know as differential interferometric measurements. Differential interferometry can provide key displacement measurements, important for the scientific studies of Earthquakes and volcanoes. Using precision real-time GPS and a sensor controlled flight management system, the system will be able to fly predefined paths with great precision. The radar will be designed to operate on a UAV (Unmanned Arial Vehicle) but will initially be demonstrated on a minimally piloted vehicle (MPV), such as the Proteus build by Scaled Composites. The application requires control of the flight path to within a 10 meter tube to support repeat track and formation flying measurements. The design is fully polarimetric with an 80 MHz bandwidth (2 meter range resolution) and 16 kilometer range swath. The antenna is an electronically steered array to assure that the actual antenna pointing can be controlled independent of the wind direction and speed. The system will nominally operate at 45,000 ft. The program started out as a Instrument Incubator Project (IIP) funded by NASA Earth Science and Technology Office (ESTO).

flight control↗

Transmission Through Carbon Nanotubes with Polyhedral Caps

We study electron transport between capped carbon nanotubes and a substrate, and relate this transport to the local density of states in the cap. Our results show that that the transmission probability mimics the behavior of the density of states at all energies except those that correspond to localized states. For a capped carbon nanotube that is not connected to a substrate, the localized states do not couple to the coexisting continuum states. However, close proximity of a substrate causes hybridization between these states. As a result, new transmission paths open from substrate states to nanotube continuum states via the localized states in the cap. We show that the interference between various paths gives rise to transmission antiresonances with the minimum equal to zero at the energy of the localized state. The presence of defects in the tube places close to the cap transforms antiresonances into resonances. Depending on the spatial position of defects, these resonant states are capable of carrying a large current. The results of this paper are of relevance to carbon nanotube based studies on molecular electronics and probe tip applications.

Anantram, M. P.↗

The Role of Instabilities in Plasmaspheric Heating, Flux Tube Refilling, and the Development of Spatial Structures

Plasma instabilities appear to play an important role in plasmasphere dynamics. Direct interactions between the plasmasphere and other plasma populations lead to energy transfer and heating, to equatorial trapping, and to changes in ionospheric outflow. Super-thermal electron and ring current populations are the dominant sources of energy for these processes. Flute (Interchange), electromagnetic lower-hybrid drift, and E x B drift instabilities can also play important roles in the distribution of thermal, plasmaspheric plasma. As our attention has returned to the remaining plasmaspheric mysteries, it has become clear that the details of plasmaspause formation and erosion and the development of localized, dense thermal plasma structures are almost completely unexplained. Radially sharp density depletions and generalized density loss are seen inside the plasmapause. Narrow and extended regions of enhanced thermal plasma density is found throughout the magnetosphere, even after extended periods of quite geomagnetic conditions. Sharp gradients are often seen on the westward edge of density enhancements, while eastward boundaries are often highly structured.

Gallagher, D. L.↗

Direct conversion of light to radio frequency energy

A description is presented of the test results obtained with the latest models of the phototron. The phototron was conceived as a replacement for the high voltage solar cell-high power klystron combination for the solar power satellite concept. Physically, the phototron is a cylindrical evacuated glass tube with a photocathode, two grids, and a reflector electrode in a planar configuration. The phototron can be operated either in a biased mode where a low voltage is used to accelerate the electron beam produced by the photocathode or in an unbiased mode referred to as self-oscillation. The device is easily modulated by light input or voltage to broadcast in AM or FM. The range of operation of the present test model phototrons is from 2 to 200 MHz.

Freeman, J. W.↗

Design, construction and evaluation of a 12.045 GHz, 2.0 kW-cw permanent-magnet focused klystron amplifier

An analytical and experimental program to demonstrate the technical feasibility of a lightweight, high-efficiency, 1-2 kW cw, permanent magnet focused klystron operating at 12.0 GHz was described. The design is based on use of a samarium-cobalt permanent magnet for focusing of the electron beam and choice of the most optimum parameters for maximum efficiency. A filter-loaded output circuit is used for the required bandwidth. The design incorporates a collector which is demountable from the tube to facilitate multistage depressed collector experiments, permitting replacement with a NASA-designed axisymmetric, electrostatic collector for linear beam microwave tubes. A further requirement is that the focusing field between the last interaction gap and the collector decay in a prescribed manner referred to as adiabatic expansion.

Nishida, J. M.↗

Thermal alteration of young kerogen in relation to petroleum genesis

Kerogen, humic acid, and lipid material were separated from a young marine sediment and heated in sealed tubes in a nitrogen atmosphere at 150 and 410 C. Gaseous and liquid products generated during heating, and also the residual organic material, were characterized by gas-liquid chromatography, elemental analysis, infrared and electron spin resonance spectroscopy, and X-ray diffraction.

Ishiwatari, R.↗

Integrated development facility for the calibration of low-energy charged particle flight instrumentation

The design of a low-energy ion facility for development and calibration of thermal ion instrumentation is examined. A directly heated cathode provides the electrons used to produce ions by impact ionization and an applied magnetic field increases the path length followed by the electrons. The electrostatic and variable geometry magnetic mirror configuration in the ion source is studied. The procedures for the charge neutralization of the beam and the configuration and function of the 1.4-m drift tube are analyzed. A microcomputer is utilized to control and monitor the beam energy and composition, and the mass- and angle-dependent response of the instrument under testing. The facility produces a high-quality ion beam with an adjustable range of energies up to 150 eV; the angular divergence and uniformity of the beam is obtained from two independent retarding potential analyzers. The procedures for calibrating the instrument being developed are described.

Biddle, A. P.↗

Balloon measurements of cosmic ray protons and helium over half a solar cycle 1965-1969.

Evaluation of differential energy spectra for protons and helium covering the energy range from 100 to 260 MeV/nucleon obtained from balloon flights made each summer (1965 to 1969) at Churchill, Manitoba, with the aid of a Geiger-tube hodoscope operated in conjunction with two scintillation elements used to measure dE/dx and E. Supplementary data from balloon flights at Minneapolis, Minn., and Sioux Falls, S. Dak. and from calibration exposures to protons and electrons were used to define backgrounds and to verify the predicted detector response. The observed proton spectra are characterized over a wide range of energy (30 to 300 MeV) by a simple relationship between cosmic-ray intensity J and kinetic energy T: J = AT. The helium spectra also follow this law at solar maximum but rise less steeply near solar minimum. This characteristic behavior can be interpreted in terms of a simple model in which convection is balanced by adiabatic deceleration.-

Rygg, T. A.↗

Evaluation of magnetic refocusing in linear-beam microwave tubes

Magnetic field configurations in which the axial component of the field decays linearly to a constant plateau field are evaluated for use in refocusing the output beam of linear beam microwave tubes. The slope of the decay and the value of the plateau field are parameters in this study. A uniform beam with a space charge force only in the radial direction is assumed, and the electron trajectories are computed for various classes. For a given magnetic configuration (slope and plateau value) the plateau length is calculated for a specified class and the rms deviation of the output angles for all classes is computed at the end of this plateau length. A minimum condition for a refocused beam is defined to be one in which the rms value of the output angles is less than the rms input. Many of the configurations satisfied this criteria and successfully reduced the rms value by half.

Stankiewicz, N.↗

Flow sensor for biomedical fluids

Electronic sensor accurately measures and controls flow of plasma, whole blood, or drugs in solution. Since sensor does not directly contact fluid, it does not have to be sterilized. It is compatible with disposable bottles, tubes, and hypodermic needles widely used in hospitals. Only modification necessary is in tube, which must contain two small metal inserts, spaced to fit in curved thermistor plates.

Winkler, H. E.↗

Production of hydrogen by electron transfer catalysis using conventional and photochemical means

Alternate methods of generating hydrogen from the sulfuric acid thermal or electrochemical cycles are presented. A number of processes requiring chemical, electrochemical or photochemical methods are also presented. These include the design of potential photoelectrodes and photocatalytic membranes using Ru impregnated nafion tubing, and the design of experiments to study the catalyzed electrolytic formation of hydrogen and sulfuric acid from sulfur dioxide and water using quinones as catalysts. Experiments are carried out to determine the value of these approaches to energy conversion.

Rillema, D. P.↗

In situ measurements of the plasma bulk velocity near the Io flux tube

The flow around the Io flux tube was studied by analyzing the eleven spectra taken by the Voyager 1 Plasma Science (PLS) experiment in its vicinity. The bulk plasma parameters were determined using a procedure that uses the full response function of the instrument and the data in all four PLS sensors. The mass density of the plasma in the vicinity of Io is found to be 22,500 + or - 2,500 amu/cu cm and its electron density is found to be 1500 + or - 200/cu cm. The Alfven speed was determined using three independent methods; the values obtained are consistent and taken together yield V sub A = 300 + or - 50 km/sec, corresponding to an Alfven Mach number of 0.19 + or - 0.02. For the flow pattern, good agreement was found with the model of Neubauer (1980), and it was concluded that the plasma flows around the flux tube with a pattern similar to the flow of an incompressible fluid around a long cylinder obstacle of radius 1.26 + or - 0.1 R sub Io.

Barnett, A.↗

Thermodynamic effect of the ion sound instability in the ionosphere

During geomagnetic disturbances when the ring current interacts intensely with the plasmasphere, the plasma of this region undergoes a strong heating due to an ion cyclotron instability. This is followed by the transfer of heat along geomagnetic field lines from the heating region to the ionosphere. One of the results of this process is the formation of non-isothermal region (in which T(sub e) greater than 3.4 T(sub i) at ionospheric heights) caused by a rapid cooling the H(+) ions due to their resonant charge exchange with neutral hydrogen. Heat transfer from the top of the flux tube to the ionosphere is investigated using a hydrodynamic model for the ionosphere-plasmasphere coupling. Field-aligned currents, present in the topside ionosphere, are often accompanied by ion sound turbulence. The turbulence scatters electrons, increasing the total electron collision frequency through wave-particle effects. The influence of wave-particle interactions introduces an anomalous component to the total collision frequency, which modifies substantially the heat conduction coefficient of the plasma. As a result, the plasma is heated more intensely above than below this region of ion sound turbulence.

Khazanov, G. V.↗

DyFK Simulation of Field-Aligned Ion Flows Observed by POLAR within Convecting Flux Over the Polar Ionosphere

Ion (O+ and H+) parallel flows along antisunward convecting flux tubes across the polar ionosphere from day to night side are simulated by an extended Dynamic Fluid semiKinetic (DyFK) model. The collision dominated portion of the flux tubes is treated with a moment-based fluid model for altitudes from 120 ?1100 km, while the generalized semikinetic model is used for the topside through 3 RE region. The effects of cleft/auroral soft electron precipitation and wave-driven transverse ion heating are incorporated into the generalized semi-kinetic treatment of topside ionosphere. The simulated evolution of field-aligned ion flow parameters is compared with observations made by the Thermal Ion Dynamics Experiment (TIDE) on board the POLAR satellite near 5000 km altitude over the southern hemisphere polar ionosphere.

Tu, J.-N.↗

Integrated Microbatteries for Implantable Medical Devices

Integrated microbatteries have been proposed to satisfy an anticipated need for long-life, low-rate primary batteries, having volumes less than 1 mm3, to power electronic circuitry in implantable medical devices. In one contemplated application, such a battery would be incorporated into a tubular hearing-aid device to be installed against an eardrum. This device is based on existing tube structures that have already been approved by the FDA for use in human ears. As shown in the figure, the battery would comprise a single cell at one end of the implantable tube. A small volume of Li-based primary battery cathode material would be compacted and inserted in the tube near one end, followed by a thin porous separator, followed by a pressed powder of a Li-containing alloy. Current-collecting wires would be inserted, with suitably positioned insulators to prevent a short circuit. The battery would contain a liquid electrolyte consisting of a Li-based salt in an appropriate solvent. Hermetic seals would be created by plugging both ends with a waterproof polymer followed by deposition of parylene.

Whitacre, Jay↗