Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Kinetic modeling of solitary wave dynamics in a neutralizing ion beam

In this work, we characterize the formation and evolution of electrostatic solitary waves (ESWs) in the space-charge neutralization of ion beams using particle-in-cell simulations. These waves become excited when the electrons emitted from an external filament source initiate a two-stream instability in the beam. We show that such electrostatic waves become excited in both two-dimensional (2D) and three-dimensional (3D) beams with different shapes and sizes. Through a 1D Bernstein–Greene–Kruskal (BGK) analysis of the 2D beam, we find that the non-Maxwellian nature of the beam electrons gives rise to large-sized ESWs that are not predicted by BGK theory since it assumes a Maxwellian electron velocity distribution in the beam. Finally, we show that a 1D BGK theory is inadequate to describe ESWs in 3D beams because of complex electron trajectories.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Five csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata - Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata - The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata - The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata - The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database.

42 ENGINEERING↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset [Slides]

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Six csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database. [Isotope]_provenance Details on the csv data provider, including laboratory and contract information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A high-power, high-repetition-rate THz source for pump–probe experiments at Linac Coherent Light Source II

Experiments using a THz pump and an X-ray probe at an X-ray free-electron laser (XFEL) facility like the Linac Coherent Light Source II (LCLS II) require frequency-tunable (3 to 20 THz), narrow bandwidth (~10%), carrier-envelope-phase-stable THz pulses that produce high fields (>1 MV cm –1 ) at the repetition rate of the X-rays and are well synchronized with them. Herein, a two-bunch scheme to generate THz radiation at LCLS II is studied: the first bunch produces THz radiation in an electromagnet wiggler immediately following the LCLS II undulator that produces X-rays from the second bunch. The initial time delay between the two bunches is optimized to compensate for the path difference in THz transport. The two-bunch beam dynamics, the THz wiggler and radiation are described, as well as the transport system bringing the THz pulses from the wiggler to the experimental hall.

42 ENGINEERING↗

Photon acceleration of high-intensity vector vortex beams into the extreme ultraviolet

Extreme ultraviolet (XUV) light sources allow for the probing of bound electron dynamics on attosecond scales, interrogation of high-energy-density matter, and access to novel regimes of strong-field quantum electrodynamics. Despite the importance of these applications, coherent XUV sources remain relatively rare, and those that do exist are limited in their peak intensity and spatio-polarization structure. Here, we demonstrate that photon acceleration of an optical vector vortex pulse in the moving density gradient of an electron beam–driven plasma wave can produce a high-intensity, tunable-wavelength XUV pulse with the same vector vortex structure as the original pulse. Quasi-3D, boosted-frame particlein- cell simulations show the transition of optical vector vortex pulses with 800-nm wavelengths and intensities below 10 18 W/cm 2 to XUV vector vortex pulses with 36-nm wavelengths and intensities exceeding 10 20 W/cm 2 over a distance of 1.2 cm. The XUV pulses have sub-femtosecond durations and nearly flat phase fronts. The production of such high-quality, high-intensity XUV vector vortex pulses could expand the utility of XUV light as a diagnostic and driver of novel light–matter interactions.

43 PARTICLE ACCELERATORS↗

Initial conditions for simulations of beam physics in linear induction accelerators

Flash radiography of hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories. At Los Alamos, the DualAxis Radiographic Hydrodynamic Test (DARHT) facility two linear induction electron accelerators (LIAs) make the bremsstrahlung radiographic source spots for point projection radiographs from orthogonal views. A new LIA, called Scorpius, is presently under development to advance this technology. To better understand electron-beam physics in these LIAs, numerical simulations are frequently performed with the objective of improving the radiography. At Los Alamos we frequently use the TRAK ray-trace and LSP particle-in-cell (PIC) codes to simulate the injector, and the XTR and LAMDA envelope/centroid codes along with LSP to simulate transport of the accelerated beam through the LIAs. The LIA simulations need the injected beam parameters as initial conditions for calculating beam transport and stability. The determination of these initial conditions is the topic of this note.

43 PARTICLE ACCELERATORS↗

Correct Initial Conditions for Simulations of Beam Physics in Linear Induction Accelerators

Flash radiography of hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories. At Los Alamos, the Dual Axis Radiographic Hydrodynamic Test (DARHT) facility two linear induction electron accelerators (LIAs) make the bremsstrahlung radiographic source spots for point projection radiographs from orthogonal views. A new LIA, called Scorpius, is presently under development to advance this technology. To better understand electron-beam physics in these LIAs, numerical simulations are frequently performed with the objective of improving the radiography. At Los Alamos we frequently use the TRAK ray-trace and LSP particle-in-cell (PIC) codes to simulate the injector, and the XTR and LAMDA envelope/centroid codes along with LSP to simulate transport of the accelerated beam through the LIAs. The LIA simulations need the injected beam parameters as initial conditions for calculating beam transport and stability. The determination of these initial conditions is the topic of this note.

43 PARTICLE ACCELERATORS↗

Pu 5f Occupation in Plutonium Dioxide

Herein an actinide N 4,5 branching ratio analysis of PuO 2 and UO 2 has been performed, including measurements with a scanning transmission electron microscope at the Advanced Light Source. It is shown that the 5f occupation of the Pu in plutonium dioxide is n = 5. This is contrary to recent results from another technique.

36 MATERIALS SCIENCE↗

Two-dimensional hydrodynamic viscous electron flow in annular Corbino rings

The concept of fluidic viscosity is ubiquitous in condensed-matter systems hosting a continuum where macroscopic properties can emerge. While an important property of liquids and some solids, only recently was the viscosity of an electron shown to play a role in electronic transport experiments. In this Letter, we present nonlocal electronic transport measurements in concentric annular rings formed in high-mobility two-dimensional electron gases, and the resulting data show that viscous hydrodynamic flow can occur far away from the source-drain current region. Our conclusion of viscous electronic transport is further corroborated by simulations of the Navier-Stokes equations that are found to be in agreement with our measurements below T = 1 K . Finally, this work emphasizes the key role played by viscosity via electron-electron ( e − e ) interaction even when the electronic transport is restricted radially, and for which it should have played no major role. Published by the American Physical Society 2025

Vijayakrishnan, Sujatha (ORCID:0009000080933182)↗

Investigating the FLASH Effect in a Rat Brain Organotypic Model With a Novel High-Energy Electron Beam

Ultrahigh dose rate (FLASH) radiation therapy is reported to reduce normal tissue toxicity while maintaining tumor control; however, mechanism(s) remain obscure. To study FLASH mechanisms in brain tissue, we developed a novel experimental platform featuring a specialized high-energy electron linear accelerator, High Intensity Gamma Ray Source (HIGS), paired with an organotypic ex vivo brain metastasis model. We varied interpulse spacing to modulate the mean dose rate (MDR) of our unique 35 MeV electron beam, while maintaining extremely high instantaneous dose rate (IDR). We characterized dosimetry and targeting accuracy of the FLASH beam with film dosimetry. We combined this FLASH beam with an organotypic rat brain slice/breast carcinoma coculture model of brain metastasis to assess effects on normal and neoplastic tissues. Live-cell and bioluminescence imaging demonstrated cancer cell growth effects, whereas normal tissue responses and immune activation were assessed using live-cell imaging, cytokine profiles, and confocal microscopy. Here, we performed comparison experiments with 20 MeV electrons from a Varian clinical linear accelerator (VCLA) using conventional dose rates. The highest IDR of the FLASH beam to date was 20.7 ± 0.6 MGy/s, with maximum MDR of 20.7 MGy/s delivered in 1 pulse of 1 µs duration. Beam targeting was accurate to <1 mm and reproducible. HIGS-FLASH and VCLA dose rates equivalently decreased cancer cell growth. HIGS-FLASH irradiation significantly increased tumor necrosis factor α and fractalkine levels and confocal microscopy revealed distinct changes in microglial morphology slices suggesting microglia activation. Our novel experimental platform produces extremely high dose rates and rapid normal/neoplastic tissue readouts for mechanistic research into the effects of FLASH radiation in the brain. HIGS-FLASH irradiation induces comparable cancer cell growth inhibition but differential effects on cytokines and microglial morphology, suggesting that acute innate immune responses may be involved in FLASH normal tissue effects in the brain.

Kay, Tyler V. [Duke University, Durham, NC (United↗

Low voltage AC electroluminescence in silicon MOS capacitors

Low power silicon based light source and detector are attractive for on-chip photonic circuits given their ease of process integration. However, conventional silicon light emitting diodes emit photons with energies near the band edge where the corresponding silicon photodetectors lack responsivity. On the other hand, previously reported hot carrier electroluminescent silicon devices utilizing a reverse biased diode require high operating voltages. Here, we investigate hot carrier electroluminescence in silicon metal–oxide–semiconductor capacitors operating under transient voltage conditions. Further, during each voltage transient, large energy band bending is created at the edge of the source contact, much larger than what is achievable at a steady state. As a result, electrons and holes are injected efficiently from a single source contact into the silicon channel at the corresponding voltage transient, where they subsequently undergo impact ionization and phonon-assisted interband recombination. Notably, we show low voltage operation down to 2.8 V by using a 20 nm thick high-κ gate dielectric. We show further voltage scaling is possible by reducing the gate dielectric thickness, thus presenting a low voltage platform for silicon optoelectronic integrated circuits.

42 ENGINEERING↗

Quantitative x-ray scattering of free molecules

Advances in x-ray free electron lasers have made ultrafast scattering a powerful method for investigating molecular reaction kinetics and dynamics. Accurate measurement of the ground-state, static scattering signals of the reacting molecules is pivotal for these pump-probe x-ray scattering experiments as they are the cornerstone for interpreting the observed structural dynamics. Here, this article presents a data calibration procedure, designed for gas-phase x-ray scattering experiments conducted at the Linac Coherent Light Source x-ray Free-Electron Laser at SLAC National Accelerator Laboratory, that makes it possible to derive a quantitative dependence of the scattering signal on the scattering vector. A self-calibration algorithm that optimizes the detector position without reference to a computed pattern is introduced. Angle-of-scattering corrections that account for several small experimental non-idealities are reported. Their implementation leads to near quantitative agreement with theoretical scattering patterns calculated with ab-initio methods as illustrated for two x-ray photon energies and several molecular test systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Observation of the molecular response to light upon photoexcitation

Abstract When a molecule interacts with light, its electrons can absorb energy from the electromagnetic field by rapidly rearranging their positions. This constitutes the first step of photochemical and photophysical processes that include primary events in human vision and photosynthesis. Here, we report the direct measurement of the initial redistribution of electron density when the molecule 1,3-cyclohexadiene (CHD) is optically excited. Our experiments exploit the intense, ultrashort hard x-ray pulses of the Linac Coherent Light Source (LCLS) to map the change in electron density using ultrafast x-ray scattering. The nature of the excited electronic state is identified with excellent spatial resolution and in good agreement with theoretical predictions. The excited state electron density distributions are thus amenable to direct experimental observation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Etching of Si 3 N 4 induced by electron beam plasma from hollow cathode plasma in a downstream reactive environment

An etching system based on the interaction of electrons extracted from a direct current (DC) hollow-cathode (HC) Ar plasma and injected towards a Si3N4 covered silicon substrate located in the downstream reactive environment created by an additional remote CF 4 /O 2 plasma source was developed and evaluated. By controlling the properties of the injected beam electrons, this approach allows to deliver energy to a surface functionalized by exposure to reactive species, and initiate surface etching. The energy of the primary beam electrons is controlled by the acceleration voltage relative to the HC discharge. Ar atoms flow from the high-pressure HC discharge into the low pressure downstream reactive environment in the process chamber. For an acceleration voltage greater than the ionization potential of Ar and/or process gas species, the energetic primary beam electrons produce a secondary plasma in the process chamber, and can also cause additional dissociation. We have characterized the properties of the secondary plasma and also surface etching of Si 3 N 4 as a function of process parameters, including acceleration voltage (0-80 V), discharge current of the HC discharge (1-2 A), pressure (3.5-20 mTorr), source to substrate distance (1.5 to 5 cm), and feed gas composition (20% and 80% O2 in CF 4 /O 2 ). The electron energy probability function (EEPF) measured with a Langmuir probe about 2.5 cm below the extraction ring suggests several major groups of electrons for this situation, including high energy primary beam electrons with an energy that varies as the acceleration voltage is changed and low energy electrons produced by beam electron-induced ionization of the Ar gas in the process chamber. When a remote CF 4 /O 2 plasma is additionally coupled to the process chamber, Si 3 N 4 surfaces can be functionalized, and by varying the energy of the beam electrons, Si 3 N 4 etching can be induced by electron-neutral synergy effect with plasma-surface interaction. For conditions without beam electron injection, the remote plasma etching rate (ER) of Si 3 N 4 depends strongly on the O 2 concentration in the CF 4 /O 2 processing gas mixture and can be suppressed for O 2 -rich process conditions by the formation of a SiONF passivation layer on the Si 3 N 4 surface. The combination of the HC electron beam source with the remote plasma source (HCEB-RP) makes it possible to induce Si 3 N 4 etching for O 2 -rich remote plasma conditions where remote plasma by itself produces negligible Si 3 N 4 etching. The electron enhanced etching of Si 3 N 4 depends strongly on O 2 /CF 4 mixing ratio reflecting changing arrival rates of O and F species at the surface. Optical emission spectroscopy was used to estimate the ratio of gas phase F and O densities and found to be controlled by the gas mixing ratio and independent of HC EB operating conditions. At this time the detailed sequence of events operative in the etching mechanism is unclear. While the increase of the electron energy is ultimately responsible for initiating surface etching, at present we cannot rule out a role of ions from the simultaneously produced secondary plasma in plasma surface interaction mechanisms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The impact of cold electrons and cold ions in magnetospheric physics

A review of the impact of the cold-ion and cold-electron populations in the Earth’s magnetosphere is presented in this paper. The cold populations are defined by total energy less than approximately 100 eV, i.e. in the energy range which is strongly affected by spacecraft charging and that often dominates the total plasma density. We also include the warm plasma cloak in the review, since it overlaps partially with the cold energy range and is a population that is still not well understood. The known impacts of cold ions and cold electrons that are discussed are: the source of magnetospheric plasma, solar-wind/magnetosphere coupling, magnetotail reconnection and substorms, Kelvin-Helmholtz instabilities at the magnetopause, chorus, hiss, electromagnetic-ion-cyclotron and ultra-low-frequency wave-particle interactions, aurora structuring and spacecraft charging. Other possible impacts are associated with refilling on open-drift trajectories, the remnant layer and plasmapause disruption. A discussion of the difficulty of cold-plasma measurements and the need for new measurement techniques that measure the full cold-ion and cold-electron distribution functions is also presented. There remain a lot of unknowns about the cold-ion and cold-electron populations, associated with their origin, properties, drivers and impacts. These populations will need to be fully understood before the magnetosphere-ionosphere system can be fully understood.

79 ASTRONOMY AND ASTROPHYSICS↗

Scalable single-mode surface-emitting laser via open-Dirac singularities

Single-aperture cavities are a key component of lasers that are instrumental for the amplification and emission of a single light mode. However, the appearance of high-order transverse modes as the size of the cavities increases has frustrated efforts to scale-up cavities while preserving single-mode operation since the invention of the laser six decades ago. A suitable physical mechanism that allows single-mode lasing irrespective of the cavity size-a 'scale invariant' cavity or laser-has not been identified yet. Here we propose and demonstrate experimentally that open-Dirac electromagnetic cavities with linear dispersion-which in our devices are realized by a truncated photonic crystal arranged in a hexagonal pattern-exhibit unconventional scaling of losses in reciprocal space, leading to single-mode lasing that is maintained as the cavity is scaled up in size. The physical origin of this phenomenon lies in the convergence of the complex part of the free spectral range in open-Dirac cavities towards a constant governed by the loss rates of distinct Bloch bands, whereas for common cavities it converges to zero as the size grows, leading to inevitable multimode emission. An unconventional flat-envelope fundamental mode locks all unit cells in the cavity in phase, leading to single-mode lasing. We name such sources Berkeley surface-emitting lasers (BerkSELs) and demonstrate that their far-field corresponds to a topological singularity of charge two, in agreement with our theory. Open-Dirac cavities unlock avenues for light-matter interaction and cavity quantum electrodynamics.

42 ENGINEERING↗

Ultrafast Dynamics of Molecules on Surfaces Studied with Time-Resolved XUV Photoelectron Spectroscopy (Final Report)

In this project we set out to make technical advances in time-resolved photoemission from surfaces and study molecule-surface charge transfer processes. Combining a novel light source developed at Stony Brook with a new type of time-of-flight photoemission electron microscope (TOF k-mic) developed in Mainz, Germany, we achieved the former goal. Our light source, based on cavity-enhanced high harmonic generation at 61 MHz repetition rate, enables ultrafast time-resolved photoemission experiments to be conducted with orders of magnitude higher photocurrents than otherwise possible. Critically, this provides the high dynamic range necessary to study perturbatively excited samples, such that one can study the intrinsic dynamics of electrons and holes as they would occur in a device. Combining our light source with the TOF k-mic, we’ve achieved an overall improvement in data rate of time- and angle-resolved photoemission (tr-ARPES) of approximately four orders of magnitude over the previous state-of-the-art using kHz-repetition rate sources and conventional hemispherical electron analyzers. This new instrument is now being used in experiments on 2D materials and organic semiconductors.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Multireference Approach to Electron and Electron–Nuclear Dynamics in Nanomaterials (Final Report)

Many important chemical and physical phenomena involve dynamics on large number of electronic states. Thus, there is a critical need to develop methods to simulate dynamics in dense manifolds of states. Towards this end, we have: a) developed the multiple cloning in dense manifolds of states (MCDMS) method, which is capable of accurately modeling the quantum mechanical coherence between populations on a large number of electronic states, b) implemented MCDMS into the free, open-source PySpawn software package, c) developed graphics processing unit-accelerated algorithms modeling electron dynamics in light fields via Floquet time-dependent configuration interaction (F-TDCI), and d) critically compared different orbital bases in order to achieve an accurate and efficient F-TDCI expansion. This grant ended in August 2020, when our group moved to from Michigan State University to Stony Brook University, where this project continues under grant number DE-SC0021643.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗