Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Laboratory Astrophysics using a Microcalorimeter and Bragg Crystal Spectrometer on an Electron Beam Ion Trap

When we last reported, our new microcalorimeter system was being prepared for delivery and permanent installation at the NIST EBIT. This occurred in June 2003 and check-out with the internal calibration source and EBIT plasma x-rays took place over the next several months during which time we modified several component parts to improve the performance. These changes included: 1) A redesign of the x-ray calibration source from a direct electron impact source to one that irradiates the microcalorimeter with fluorescent x-rays. The resulting calibration lines are free of bremsstrahlung background; 2) The microcalorimeter electronic circuit has been significantly improved to ensure long-term stability for the lengthy upcoming runs of the EBIT. Both the preamplifier feedback resistors were changed and the first stage of the preamplifier redesigned. Several photos of the new system are shown in slides 3 and 4. This microcalorimeter spectrometer only requires helium refills every three days (as opposed to every 24 hours in our earlier system) and it will hold a temperature of 65 mK for up to 48 hours (as opposed to 8 hours). Consequently, the efficiency of data acquisition will improve dramatically. The first x-ray spectra of the new calibration source made with the 4-element detector array is shown. An example of the temperature control capabilities of the ADR for a 23 hour interval is shown. The horizontal line shows the temperature stability (about +/- 3 micro kelvin). There are a few short-lived heating excursions caused by technical staff working on the EBIT machine simultaneously. During actual experimental runs these are absent. This temporal profile was interrupted to test additional components of the system; otherwise, the temperature controlling would have continued for another 24 hours.

Silver, Eric↗

Simulations of ion heating due to ion-acoustic instabilities in presheaths

Particle-in-cell, direct simulation Monte Carlo simulations reveal that ion-acoustic instabilities excited in presheaths can cause significant ion heating. Ion-acoustic instabilities are excited by the ion flow toward a sheath when the neutral gas pressure is small enough and the electron temperature is large enough. A series of 1D simulations were conducted in which neutral plasma (electrons and ions) was uniformly sourced with an ion temperature of 0.026 eV and different electron temperatures (0.1 eV–50 eV). Ion heating was observed when the electron-to-ion temperature ratio exceeded the minimum value predicted by linear response theory to excite ion-acoustic instabilities at the sheath edge (T e /T i ≈ 28). When this threshold was exceeded, the temperature equilibration rate between ions and electrons rapidly increased near the sheath so that the local temperature ratio did not significantly exceed the threshold for instability. This resulted in significant ion heating near the sheath edge, which also extended back into the bulk plasma; presumably due to wave reflection from the sheath. Furthermore, this ion-acoustic wave heating mechanism was found to decrease for higher neutral pressures, where ion-neutral collisions damp the ion-acoustic waves and ion heating is instead dominated by inelastic collisions in the presheath.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiometric Calibration Techniques for Signal-of-Opportunity Reflectometers

Bi-static reflection measurements utilizing global navigation satellite service (GNSS) or other signals of opportunity (SoOp) can be used to sense ocean and terrestrial surface properties. End-to-end calibration of GNSS-R has been performed using well-characterized reflection surface (e.g., water), direct path antenna, and receiver gain characterization. We propose an augmented approach using on-board receiver electronics for radiometric calibration of SoOp reflectometers utilizing direct and reflected signal receiving antennas. The method calibrates receiver and correlator gains and offsets utilizing a reference switch and common noise source. On-board electronic calibration sources, such as reference switches, noise diodes and loop-back circuits, have shown great utility in stabilizing total power and correlation microwave radiometer and scatterometer receiver electronics in L-band spaceborne instruments. Application to SoOp instruments is likely to bring several benefits. For example, application to provide short and long time scale calibration stability of the direct path channel, especially in low signal-to-noise ratio configurations, is directly analogous to the microwave radiometer problem. The direct path channel is analogous to the loopback path in a scatterometer to provide a reference of the transmitted power, although the receiver is independent from the reflected path channel. Thus, a common noise source can be used to measure the gain ratio of the two paths. Using these techniques long-term (days to weeks) calibration stability of spaceborne L-band scatterometer and radiometer has been achieved better than 0.1. Similar long-term stability would likely be needed for a spaceborne reflectometer mission to measure terrestrial properties such as soil moisture.

calibrating↗

Radiation studies of optical and electronic components used in astronomical satellite studies

The synchronous orbit of the IUE carries the satellite through Earth's outer electron belt. A 40 mCi Sr90 source was used to simulate these electrons. A 5 mCi source of Co60 was used to simulate bremmstrahlung. A 10 MeV electron Linac and a 1.7 MeV electron Van de Graaf wer used to investigate the energy dependence of radiation effects and to perform radiations at a high flux rate. A 100 MeV proton cyclotron was used to simulate cosmic rays. Results are presented for three instrument systems of the IUE and measurements for specific components are reported. The three instrument systems were the ultraviolet converter, the fine error sensor (FES), and the SEC vidicon camera tube. The components were optical glasses, electronic components, silicon photodiodes, and UV window materials.

Becher, J.↗

Plasma electron acceleration driven by a long-wave-infrared laser

Laser-driven plasma accelerators provide tabletop sources of relativistic electron bunches and femtosecond x-ray pulses, but usually require petawatt-class solid-state-laser pulses of wavelength λ L ~ 1 μm. Longer-λ L lasers can potentially accelerate higher-quality bunches, since they require less power to drive larger wakes in less dense plasma. Here, we report on a self-injecting plasma accelerator driven by a long-wave-infrared laser: a chirped-pulse-amplified CO 2 laser (λ L ≈ 10 μm). Through optical scattering experiments, we observed wakes that 4-ps CO 2 pulses with < 1/2 terawatt (TW) peak power drove in hydrogen plasma of electron density down to 4 × 10 17 cm –3 (1/100 atmospheric density) via a self-modulation (SM) instability. Shorter, more powerful CO 2 pulses drove wakes in plasma down to 3 × 10 16 cm –3 that captured and accelerated plasma electrons to relativistic energy. Collimated quasi-monoenergetic features in the electron output marked the onset of a transition from SM to bubble-regime acceleration, portending future higher-quality accelerators driven by yet shorter, more powerful pulses.

43 PARTICLE ACCELERATORS↗

INTEGRAL/SPI Limits on Electron-Positron Annihilation Radiation from the Galactic Plane

The center of our Galaxy is a known strong source of electron-positron 511- keV annihilation radiation. Thus far, however, there have been no reliable detections of annihilation radiation outside of the central radian of our Galaxy. One of the primary objectives of the INTEGRAL (INTErnational Gamma-RAy Astrophysics Laboratory) mission, launched in Oct. 2002, is the detailed study of this radiation. The Spectrometer on INTEGRAL (SPI) is a high resolution coded-aperture gamma-ray telescope with an unprecedented combination of sensitivity, angular resolution and energy resolution. We report results from the first 10 months of observation. During this period a significant fraction of the observing time was spent in or near the Galactic Plane. No positive annihilation flux was detected outside of the central region (|l| greater than 40 degrees) of our Galaxy. In this paper we describe the observations and data analysis methods and give limits on the 511-keV flux.

Teegarden, B. J.↗

Electronic Systems for Proposed Anti-Proton Source Accumulator Core Betatron Systems

New waveguide pickups and kickers have been proposed for the accumulator core betatron systems. With new waveguide components, the electronics of the system have to be redesigned. The waveguide components have new frequency bands and power concerns that have to be addressed. This paper discusses the calculations used to design the new electronic system, and it also discusses the practical concerns of the electronic hardware.

43 PARTICLE ACCELERATORS↗

Development of a uninterrupted power system: ac and dc to dc converter

This program covered the design, fabrication and testing of an advanced development model uninterrupted power system. The input and output requirements imposed on the power processor were specified such that the unit is electrically interchangeable with existing power systems used by the Federal Aviation Administration in installations which have a history of failure due to electrical transient conditions. Input power is from either of two single-phase ac power sources or batteries with electronic selection and transfer between power sources. Battery reconditioning is automatic when either ac source is present. The output power is rated at 84OW; the nominal output is 24V at 35A. Within the 84OW limit, the regulated output voltage is adjustable from 22V to 30Vdc. Protection against continuous overloading or short circuit is provided. The unit is packaged in a standard 19-inch rack mount configuration with 7-inch panel height. Controls are on the front panel with power input and output through connectors on the rear surface. Cooling is by free convection from fin areas located on the side and rear panels. The packaged unit weighs 52.8 lbs., which can be reduced significantly if a three-phase ac power source is used.

Cronin, D. L.↗

Scalable standard optical sources in the VUV: Emissions from electron impact on metals

The use of electron impact on metals in the development of a compact optical standard lamp in the vacuum ultraviolet is described. Two different mechanisms are exploited, transition radiation and bremsstrahlung. Transition radiation will be used as a primary standard from 1200A to 3000A using 10 keV electron impact on tungsten. Bremsstrahlung will be used in the soft X-ray region below 1200A to less than 5A as an optical transfer standard from 4 keV electron impact on tantalum or tungsten.

Hughes, R.↗

In Situ Geochemical Analysis and Age Dating of Rocks Using Laser Ablation-Miniature Mass Spectrometer

A miniaturized instrument for performing chemical and isotopic analysis of rocks has been developed. The rock sample is ablated by a laser and the neutral species produced are analyzed using the JPL-invented miniature mass spectrometer. The direct sampling of neutral ablated material and the simultaneous measurement of all the elemental and isotopic species are the novelties of this method. In this laser ablation-miniature mass spectrometer (LA-MMS) method, the ablated neutral atoms are led into the electron impact ionization source of the MMS, where they are ionized by a 70-eV electron beam. This results in a secondary ion pulse typically 10-100 microsecond wide, compared to the original 5-10-nanosecond laser pulse duration. Ions of different masses are then spatially dispersed along the focal plane of the magnetic sector of the miniature mass spectrometer and measured in parallel by a modified CCD (charge-coupled device) array detector capable of detecting ions directly. Compared to conventional scanning techniques, simultaneous measurement of the ion pulse along the focal plane effectively offers a 100% duty cycle over a wide mass range. LAMMS offers a more quantitative assessment of elemental composition than techniques that detect laser-ionized species produced directly in the ablation process because the latter can be strongly influenced by matrix effects that vary with the structure and geometry of the surface, the laser beam, and the ionization energies of the elements. The measurement of high-precision isotopic ratios and elemental composition of different rock minerals by LAMMS method has been demonstrated. The LA-MMS can be applied for the absolute age determination of rocks. There is no such instrument available presently in a miniaturized version that can be used for NASA space missions. Work is in progress in the laboratory for geochronology of rocks using LA-MMS that is based on K-Ar radiogenic dating technique.

Sinha, Mahadeva P.↗

Full Inversion of Solar Relativistic Electron Events Measured by the Helios Spacecraft

The Parker Solar Probe and the incoming Solar Orbiter mission will provide measurements of solar energetic particle (SEP) events at close heliocentric distances from the Sun. Up to present, the largest data set of SEP events in the inner heliosphere are the observations by the two Helios spacecraft. Aims.We re-visit a sample of 15 solar relativistic electron events measured by the Helios mission with the goal of better characterizing the injection histories of solar energetic particles and their interplanetary transport conditions at heliocentric distances <1AU. Methods. The measurements provided by the E6 instrument on board Helios provide us with the electron directional distributionsin eight di erent sectors that we use to infer the detailed evolution of the electron pitch-angle distributions. The results of a Monte Carlo interplanetary transport model, combined with a full inversion procedure, were used to fit the observed directional intensities in the 300–800 keV nominal energy channel. Unlike previous studies, we have considered both the energy and angular responses of the detector. This method allowed us to infer the electron release time profile at the source and determine the electron interplanetary transport conditions. Results. We discuss the duration of the release time profiles and the values of the radial mean free path, and compare them with thevalues reported previously in the literature using earlier approaches. Five of the events show short injection histories (<30 min) at the Sun and ten events show long-lasting (>30 min) injections. The values of mean free path range from 0.02AU to 0.27AU.Conclusions. The inferred injection histories match with the radio and soft X-ray emissions found in literature.We find no dependence of the radial mean free path on the radial distance. In addition, we find no apparent relation between the strength of interplanetary scattering and the size of the solar particle release.

Pacheco, D.↗

Ion source design for industrial applications

The more frequently used design techniques for the components of broad-beam electron bombardment ion sources are discussed. The approach used emphasizes refractory metal cathodes and permanent-magnet multipole discharge chambers. Design procedures and sample calculations are given for the discharge chamber, ion optics, the cathodes, and the magnetic circuit. Hardware designs are included for the isolator, cathode supports, anode supports, pole-piece assembly, and ion-optics supports. A comparison is made between two-grid and three-grid optics. The designs presented are representative of current technology and are adaptable to a wide range of configurations.

Kaufman, H. R.↗

Lactiplantibacillus plantarum uses ecologically relevant, exogenous quinones for extracellular electron transfer

Extracellular electron transfer (EET) is a metabolic process that frequently uses quinones to couple intracellular redox reactions with extracellular electron acceptors. The physiological relevance of this metabolism for microorganisms capable of EET but unable to synthesize their own quinones remains to be determined. To address this question, we investigated quinone utilization by Lactiplantibacillus plantarum, a microorganism required for food fermentations, that performs EET and is also a quinone auxotroph. L. plantarum selectively used 1,4-dihydroxy-2-naphthoic acid (DHNA) and more hydrophilic naphthoquinones for EET reduction of insoluble iron (ferrihydrite). However, quinones used for EET also inhibited L. plantarum growth in non-aerated conditions. Transcriptomic analysis showed that DHNA-induced oxidative stress in L. plantarum, but this was alleviated when the electron acceptor, ferric ammonium citrate (FeAC), was included in the growth medium. Although DHNA and FeAC induced L. plantarum EET, this metabolism was still dependent on direct access to environmental electron shuttles. To determine whether quinone-producing food fermentation bacteria could be sources of those electron shuttles, L. plantarum EET was measured after incubation with Lactococcus lactis and Leuconostoc mesenteroides. Quinone-producing L. lactis, but not a quinone-deficient L. lactis ΔmenC mutant, increased L. plantarum ferrihydrite reduction and medium acidification through an EET-dependent mechanism. L. plantarum EET was also stimulated by L. mesenteroides, resulting in greater environmental acidification and transient increases in L. plantarum cell numbers. Our findings show that L. plantarum overcomes the toxic effects of exogenous quinones to use those compounds for EET-conferred, ecological advantages during the early stages of food fermentations.

59 BASIC BIOLOGICAL SCIENCES↗