Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Online and Offline Data Quality Monitoring for the Mu2e Calorimeter

This thesis presents the design, implementation, and validation of a calorimeter Data Quality Monitoring (DQM) toolchain for the Mu2e experiment at Fermilab. Mu2e searches for charged lepton flavor violation via coherent muon-to-electron conversion in the field of an aluminum nucleus, $\mu^- Al \rightarrow e^-Al$, a process whose observation would constitute clear evidence of physics beyond the Standard Model. Achieving target sensitivity requires stringent control of detector performance and data integrity during acquisition, as subtle issues in readout configuration, data formatting, or electronics behavior can compromise reconstruction and bias downstream analyzes. To address these challenges, this work develops a multi-layer DQM approach spanning both raw data validation and reconstructed digi-level diagnostics. At the low level, a fragment analysis component performs word- and bit-field decoding of calorimeter readout blocks, enabling sanity checks of the expected structure and producing detailed error and integrity statistics useful for commissioning and troubleshooting. At the digi level, the CaloDigiDQM analyzer is implemented within the art framework and transforms each CaloDigiCollection into a structured hierarchy of ROOT histograms designed for fast drill-down diagnostics. The module generates coherent monitoring views at global, disk, board, and channel granularity, including occupancy, waveform-derived features (baseline, RMS, peak amplitude and position), and left-right sensor consistency metrics. Detector-aware channel-to-electronics mapping is performed through the conditions system (CaloDAQMap), ensuring that diagnostics remain aligned with hardware identifiers used in operations. For end-to-end testing without reliance on live DAQ data, a synthetic CaloDigi producer is developed to generate realistic waveforms with controlled noise and pulse shapes. The resulting system supports both offline ROOT-file production and online operation, including optional histogram streaming through otsdaq via ots::HistoSender. This toolchain provides a practical and scalable foundation for calorimeter commissioning and stable data collection, enabling early detection of anomalies and reducing operational risk for Mu2e.

Vakulenko, Mark [Drew U.] (ORCID:0009000276197818)↗

Digitization modeling of a CGEM detector based on Garfield++ simulation

Abstract Background The Cylindrical Gas Electron Multiplier Inner Tracker (CGEM-IT) is one of the candidates for the replacement of the current BESIII inner drift chamber, which has developed serious aging effects due to beam-related backgrounds. Purpose To build a full digitization model, it is necessary to understand the electron drift behavior and signal induction. Methods A simulation study based on Garfield++ and ANSYS software has been performed. Results Parameters describing the Lorentz angle, diffusion effect, drift time, multiplication, and induction are obtained from the Garfield++ simulation. Based on these results, a preliminary digitization model is implemented in the BESIII offline software system.

Zhao, Jing-Yi (ORCID:0000000220287286)↗

Planar laser induced fluorescence mapping of a carbon laser produced plasma

We present measurements of ion velocity distribution profiles obtained by laser induced fluorescence (LIF) on an explosive laser produced plasma. The spatiotemporal evolution of the resulting carbon ion velocity distribution was mapped by scanning through the Doppler-shifted absorption wavelengths using a tunable, diode-pumped laser. The acquisition of these data was facilitated by the high repetition rate capability of the ablation laser (1 Hz), which allowed for the accumulation of thousands of laser shots in short experimental times. By varying the intensity of the LIF beam, we were able to explore the effects of fluorescence power against the laser irradiance in the context of evaluating the saturation vs the non-saturation regime. The small size of the LIF beam led to high spatial resolution of the measurement compared to other ion velocity distribution measurement techniques, while the fast-gate operation mode of the camera detector enabled the measurement of the relevant electron transitions.

Instruments & Instrumentation↗

Sensor response and radiation damage effects for 3D pixels in the ATLAS IBL Detector

Pixel sensors in 3D technology equip the outer ends of the staves of the Insertable B Layer (IBL), the innermost layer of the ATLAS Pixel Detector, which was installed before the start of LHC Run 2 in 2015. 3D pixel sensors are expected to exhibit more tolerance to radiation damage and are the technology of choice for the innermost layer in the ATLAS tracker upgrade for the HL-LHC programme. While the LHC has delivered an integrated luminosity of ≃ 235 fb -1 since the start of Run 2, the 3D sensors have received a non-ionising energy deposition corresponding to a fluence of ≃ 8.5 × 10 14 1 MeV neutron-equivalent cm -2 averaged over the sensor area. This paper presents results of measurements of the 3D pixel sensors' response during Run 2 and the first two years of Run 3, with predictions of its evolution until the end of Run 3 in 2025. Data are compared with radiation damage simulations, based on detailed maps of the electric field in the Si substrate, at various fluence levels and bias voltage values. These results illustrate the potential of 3D technology for pixel applications in high-radiation

47 OTHER INSTRUMENTATION↗

Search for the semileptonic decays Ξ c 0 → Ξ 0 ℓ + ℓ − at Belle

Using the full data sample of 980 fb − 1 collected with the Belle detector at the KEKB asymmetric energy electron-positron collider, we report the results of the first search for the rare semileptonic decays Ξ c 0 → Ξ 0 ℓ + ℓ − ( ℓ = e or μ ). No significant signals are observed in the Ξ 0 ℓ + ℓ − invariant-mass distributions. Taking the decay Ξ c 0 → Ξ − π + as the normalization mode, we report 90% credibility upper limits on the branching fraction ratios B ( Ξ c 0 → Ξ 0 e + e − ) / B ( Ξ c 0 → Ξ − π + ) < 6.7 × 10 − 3 and B ( Ξ c 0 → Ξ 0 μ + μ − ) / B ( Ξ c 0 → Ξ − π + ) < 4.3 × 10 − 3 based on the phase-space assumption for signal decays. The 90% credibility upper limits on the absolute branching fractions of B ( Ξ c 0 → Ξ 0 e + e − ) and B ( Ξ c 0 → Ξ 0 μ + μ − ) are found to be 9.9 × 10 − 5 and 6.5 × 10 − 5 , respectively. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Search for the leptonic decays D * + → e + ν e and D * + → μ + ν μ

We present the first search for the leptonic decays D * + → e + ν e and D * + → μ + ν μ by analyzing a data sample of electron-positron collisions recorded with the BESIII detector at center-of-mass energies between 4.178 and 4.226 GeV, corresponding to an integrated luminosity of 6.32 fb − 1 . No significant signal is observed. The upper limits on the branching fractions for D * + → e + ν e and D * + → μ + ν μ are set to be 1.1 × 10 − 5 and 4.3 × 10 − 6 at 90% confidence level, respectively. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Study of D s + → f 0 ( 980 ) ρ + and ϕ π + Decays through D s + → π + π + π − π 0

We perform the first amplitude analysis of D s + → π + π + π − π 0 decays based on data samples of electron-positron collisions recorded with the BESIII detector at center-of-mass energies between 4.128 and 4.226 GeV, corresponding to an integrated luminosity of 7.33 fb − 1 . We report the observation of D s + → f 0 ( 980 ) ρ ( 770 ) + with a statistical significance greater than 10 σ and determine the branching fractions B ( D s + → π + π + π − π 0 | non − η ) = ( 2.04 ± 0.0 8 stat ± 0.0 5 syst ) % and B ( D s + → η π + ) = ( 1.56 ± 0.0 9 stat ± 0.0 4 syst ) % . Moreover, we measure the relative branching fraction between ϕ → π + π − π 0 and ϕ → K + K − to be [ B ( ϕ ( 1020 ) → π + π − π 0 ) / B ( ϕ ( 1020 ) → K + K − ) ] = 0.230 ± 0.01 4 stat ± 0.01 0 syst ., which deviates from the world average value by more than 4 σ . Published by the American Physical Society 2025

Ablikim, M.↗

The VMM3a ASIC

The VMM3a is a custom low-noise Application Specific Integrated Circuit. It is intended to be used in the front end readout electronics of both the Micromegas and sTGC detectors of the ATLAS New Small Wheels upgrade project at CERN. It is fabricated in the 130 nm GlobalFoundries 8RF-DM process. Here, the 64 channels with highly configurable parameters, although designed for a specific project, can meet the processing needs of signals from various detector types in several other applications. In this note, the VMM3a, which is the production version of the VMM family, will be presented along with the features incorporated and its performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plasma enhanced atomic layer deposition and atomic layer etching of gallium oxide using trimethylgallium

Atomic layer etching driven by self-limiting thermal reactions has recently been developed as a highly conformal and isotropic technique for low damage atomic scale material removal by sequential exposures of vapor phase reactants. Gallium oxide (Ga2O3) is currently among the materials of interest due to a large variety of applications including power electronics, solar cells, gas sensors, and photon detectors. In this study, Ga2O3 was deposited by plasma enhanced atomic layer deposition using trimethylgallium [TMG, Ga(CH3)3] and O2 plasma at a substrate temperature of 200 °C. We report a newly developed method for Ga2O3 thermal atomic layer etching, in which surface modification is achieved through HF exposure resulting in a gallium fluoride surface layer, and then removed through volatile product formation via ligand exchange with TMG. Saturation of the precursor exposure at a substrate temperature of 300 °C resulted in an etch rate of 1.0 ± 0.1 Å/cycle for amorphous Ga2O3. Uniformity and conformality of the atomic layer etching process were confirmed via atomic force microscopy with a measured surface roughness of 0.55 ± 0.05 nm that remains unchanged after etching. The use of TMG for etching may expand available precursors for atomic layer etching processes, while allowing for both etching and deposition of Ga2O3 using the same metalorganic precursor.

Hatch, Kevin A. (ORCID:0000000283118623)↗

Implementation of quantum key distribution and quantum clock synchronization via time bin encoding

Quantum key distribution allows for a provably secure transmission of cryptographic keys over an optical channel. Encoded polarization states or time-bin degree of freedom have been used for successful demonstrations. However, photon losses in long fibers, slow single photon detectors, and detector dark counts significantly limit the overall bit rate. Improving key throughput and reducing the overhead of key reconciliation remain as major challenges. Methods which utilize multiple time bins allow for multiple key bits to be encoded in a single photon, thus increasing the fidelity of transmitted keys and decreasing the overhead of key reconciliation in real-world conditions. Previous implementations of these methods required that Alice and Bob share a time reference by sharing a dedicated classical channel used for synchronization. This work presents a technique that allows two parties to exchange time-bin encoded photons without the need for synchronized time references. Our technique uses a framing protocol which allows Alice to encode a time reference along with a key which is determined by Alice before transmission. Security can be achieved by monitoring the visibility of a pair of Franson interferometers, using decoy pulses and measuring the round trip time between Alice and Bob. The bit rate of this technique is limited only by the recovery time of the detector and the speed of the modulation electronics. We experimentally demonstrate a raw bit rate of 5Mb/s over an optical channel with 55dB of loss, which is competitive with current research. We also demonstrate absolute timing synchronization with an accuracy of 20ps.

encryption↗

The Astrophysics Program of NOvA [Poster]

The NOvA detectors, designed primarily to discover and measure electron neutrino appearance in a muon neutrino beam, are versatile instruments being used for a variety of astrophysical analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Bayesian Fit for the NOvA Three Flavor Oscillation Analysis

NOvA is a long baseline neutrino oscillation experiment, using Fermilab's NuMI beam and a functionally identical near and far detector. NOvA measures muon neutrino disappearance and electron neutrino appearance to probe neutrino oscillation parameters, including the large neutrino mixing angle, the mass ordering, and the CP-violating phase. NOvA has developed a Bayesian analysis in addition to its Frequentist analysis, using Markov Chain Monte Carlo. This Bayesian framework allows for measurements previously difficult to make with the Frequentist framework, such as the Jarlskog invariant and the reactor mixing angle. The details and status of the Bayesian Framework will be presented, as well as latest NOvA results on measurements of three-flavor oscillation parameters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Final Report for Grant

This is the final report for this project. The major objectives were to develop full models and standard cells of CMOS silicon photomultipliers (SiPM) for neutron detection applications. Specifically, the research seeks to replace photomultiplier tubes, used in neutron detection applications, with SiPMs containing integrated readout electronics fabricated in standard CMOS processes. The detectors improve on the detection efficiency, readout speed, resolution (sensitivity), and spatial resolution of current systems. In particular, this work involved collaboration with the instrument and detector group at ORNL who build detectors based on discrete commercially available PMTs and SiPMs. The SiPM detectors developed in this work are based on Perimeter Gated Single Photon Avalanche Diodes (PGSPAD). These devices have tunable breakdown voltage which affects other performance characteristics of the detectors. The ability of the detectors to have integrated readout and tune the noise floor and dynamic range in addition to offering a method for non-uniformity compensation in a compact form significantly impacts the imaging research field and includes the nuclear sciences field, circuits and systems field in addition to varied fields such as geography and biology/medicine.

42 ENGINEERING↗

Epoxy-based infrared filter assembly and associated fabrication devices and method

Epoxy-based inline infrared (IR) filter assembly, and manufacture and use of the same. Co-axial infrared filter assemblies comprise a substantially cylindrical filter body forming a central cavity characterized by opposing holes at each end. The filter body forms an outer conductor, and SMA connectors coupled to the opposing holes at each end of the body are electrically coupled to form an inner conductor positioned along a long axis of the filter body. An infrared absorbing material (such as castable epoxy resin) fills the central cavity of the filter body. Methods for producing the co-axial infrared filter include pressing SMA connectors into the respective ends of the filter body, electrically coupling the SMA connectors, and filling the filter body with epoxy. Electronic systems for operating a dark matter detector include a feedline comprising a coaxial filter configured to advantageously block infrared noise.

Spahn, Gabriel↗

Mu2e Tracker Electronics - Construction of a Straw Tracker

The Mu2e experiment, currently under construction at the Fermi National Accelerator Laboratory (FNAL) in Batavia, Illinois, is a particle physics experiment designed to detect Charged Lepton Flavor Violation (CLFV) via muon-to-electron conversion, a process beyond the Standard Model (BSM). One of the primary Mu2e detectors is the Straw Tracker, whose purpose is to measure the momentum of the electron, identify the signal, and reject background. The straw tubes are being read out by a total of 20,736 preamplifiers (preamps) within 36 planes that make up the Tracker. In this presentation, the installation of electronics into the Tracker, the implementation of anti-oscillation copper clips, and the process of installing fully constructed planes into the frame will be discussed in depth.

Lynch, Alec [UC, Berkeley]↗

A method to determine the electric field of liquid argon time projection chambers using a UV laser system and its application in MicroBooNE

Liquid argon time projection chambers (LArTPCs) are now a standard detector technology for making accelerator neutrino measurements, due to their high material density, precise tracking, and calorimetric capabilities. An electric field (E-field) is required in such detectors to 2020 JINST 15 P07010 drift ionization electrons to the anode where they are collected. The E-field of a TPC is often approximated to be uniform between the anode and the cathode planes. However, significant distortions can appear from effects such as mechanical deformations, electrode failures, or the accumulation of space charge generated by cosmic rays. The latter effect is particularly relevant for detectors placed near the Earth’s surface and with large drift distances and long drift time. To determine the E-field in situ, an ultraviolet (UV) laser system is installed in the MicroBooNE experiment at Fermi National Accelerator Laboratory. The purpose of this system is to provide precise measurements of the E-field, and to make it possible to correct for 3D spatial distortions due to E-field non-uniformities. Here we describe the methodology developed for deriving spatial distortions, the drift velocity and the E-field from UV-laser measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector

This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axionlike particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 g Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 g-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section σ ¯ e is constrained for dark matter masses from 0.5 to 10 4 MeV / c 2 ; in the mass range from 1.2 to 50 eV / c 2 the dark photon kinetic mixing parameter ϵ and the axioelectric coupling constant g a e are constrained. The minimum 90% confidence-level upper limits within the above-mentioned mass ranges are σ ¯ e = 8.7 × 10 - 34 cm 2 , ϵ = 3.3 × 10 - 14 , and g a e = 1.0 × 10 - 9 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Fuel Motion Monitoring System at TREAT - Current Status and Future Plans

An important component of the United States Nuclear Fuel Safety Transient Testing Program, the Fuel Motion Monitoring System (FMMS) at Idaho National Laboratory's Transient Reactor Test Facility (TREAT) is fast-neutron hodoscope capable of imaging the location, movement, and relocation of nuclear fuel experiments under simulated transient accident conditions. The FMMS was refurbished in parallel with the TREAT restart program starting in 2014, restoring 96-channels of fast-neutron detection. Since returning to operation in 2017 the FMMS has supported many fuel safety experiments supporting accident tolerant fuel development, light-water reactor safety, space thermal nuclear propulsion fuel development, and advanced reactor research and development. In Phase 2 of the FMMS restoration. work is now under way to expand the FMMS' field-of-view by adding an additional 96 channels of fast neutron detectors to the system's hodoscope, along with an expanded data acquisition system and associated transient timing electronics. An overview of the FMSS system and its fast-neutron detectors will be presented along with examples of current FMMS imaging performance and associated information.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗