Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

The response of covered silicon detectors to monoenergetic gamma rays

Measurements were made of the efficiency in detecting gamma rays of a 0.3-mm, a 3-mm, and a 5-mm silicon detector covered with different absorbers. Calibrated sources covering the range from 279 KeV to 2.75 MeV were used. The need for the absorbers in order to obtain meaningful results, and their contribution to detector response at electron biases from 50 to 200 KeV, are discussed in detail. It is shown that the results are independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias setting is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.↗

Observations of low-energy /0.3- to 1.8-MeV/ differential spectrums of trapped protons.

Measurements of differential energy spectrums of trapped protons obtained from several passes during the period January to November 1969 using the polar orbiting, low-altitude Injun 5 satellite equipped with a special solid-state detector proton-electron telescope are presented. Results reveal the existence of a quasi-persistent peak in the differential energy spectrum in the McIlwain shell parameter (L) range 2 to 2.6 and in the energy range of approximately 0.32 to 0.72 MeV. The fact that the shape of the spectrum is stable for several days or can change with time scales as small as 4 hours suggests an impulsive acceleration mechanism deep in the radiation belts. Other features of the spectrum show that if the spectrum is represented by an exponential form in energy, the dependence of the spectral parameter is in general agreement with diffusion theory over the L range of approximately 2 to 4.

Venkatesan, D.↗

Superconducting magnetic spectrometer for cosmic ray nuclei.

This paper describes the design, calibration, and operation of a magnetic spectrometer for particle astronomy. The spectrometer consists of a superconducting magnet, optical spark chambers, scintillation detectors, and associated electronics. The instrument has been flown in a balloon gondola to 4.8 g/sq cm residual atmosphere, where it was used to analyze the charge and differential rigidity spectra of primary nuclei from 5 to 100 GeV/c.

Smith, L. H.↗

Design, fabrication, assembly and delivery of a laboratory prototype of a residual gas analyzer

The design, development, and testing of a wide mass range residual gas analyzer which will be one component of an integrated real time contamination monitor system are described. The instrument has been developed and tested to the laboratory prototype phase, demonstrating the performance that can be expected from a flight instrument of similar design. The instrument's analyzer is of the quadrupole type and a cold cathode ion source is employed as the ionizer. The associated electronics supply all necessary operating and mass sweep voltages for the ionizer, analyzer and electron multiplier ion detector. The instrument features a very fast linear electrometer with automatic range changing. The full mass range of 2 to 300 amu is automatically and repetitively scanned every sixty seconds and suitable telemetry outputs are provided for intensity and mass identification as well as a digital identification of the electrometer range.

Kreisman, W. S.↗

Helical channel multiplier package design for space instrumentation

The package considered is intended for the channel electron multiplier (CEM) detectors which are to be used for the extreme ultraviolet telescope and helium glow detector instruments of the Apollo-Soyuz test project. In the package design selected, the cone of the CEM is supported at the front end by a silicone rubber ring which is molded in place and self-bonded to both the cone and the housing wall. The helix is supported and insulated from the housing by a fiber glass sleeve which is bonded to the inside of the housing.

Hoshiko, H. H.↗

Silicon solid/state linear arrays for multispectral high resolution imaging systems

Solid-state, electronically scanned, linear detector arrays are now available which can be used in a pushbroom scan mode imaging system for high-resolution multispectral earth resource survey applications. These arrays provide high performance in the visible to near-IR region. Two performance criteria must be assessed in the choice of a detector array: signal-to-noise ratio and spectral response. Consideration of diffraction limitations shows that optics size cannot be significantly reduced by using very low-noise detectors. The required spectral response for a viable detector array should not have spectral ripples that cause a low-level, but significant, error in the detected effective reflectance of the target.

Thompson, L. L.↗

The Pioneer 10 plasma analyzer results at Jupiter

Results are reported for the Pioneer 10 plasma-analyzer experiment at Jupiter. The analyzer system consisted of dual 90-deg quadrispherical electrostatic analyzers, multiple charged-particle detectors, and attendant electronics; it was capable of determining the incident plasma-distribution parameters over the energy range from 100 to 18,000 eV for protons and from approximately 1 to 500 eV for electrons. Data are presented on the interaction between the solar wind and the Jovian magnetosphere, the interplanetary ion flux, observations of the magnetosheath plasma, and traversals of the bow shock and magnetopause. Values are estimated for the proton isotropic temperature, number density, and bulk velocity within the magnetosheath flow field as well as for the beta parameter, ion number density, and magnetic-energy density of the magnetospheric plasma. It is argued that Jupiter has a reasonably thick magnetosphere somewhat similar to earth's except for the vastly different scale sizes involved.

Wolfe, J. H.↗

Comment on low energy electron measurements in the Jovian magnetosphere

It is suggested that the low energy electrons reported by Intriligator and Wolfe (1974) in the outer magnetosphere of Jupiter may actually be photoelectrons and/or secondary electrons from the Pioneer spacecraft surfaces. The electron spectrum is similar to the observed photoelectron spectrum on earth-orbiting satellites where differentially charged surfaces have deflected the electrons into particle detectors.

Grard, R. J. L.↗

A general study of techniques for ultraviolet astrophysical studies on space vehicles

Recent accomplishments in three areas of UV instrumentation for space astronomy are discussed. These areas include reliable UV photometry, sensitive photon-detection techniques, and precise telescope pointing. Calibration facilities for spectrometers designed to operate in the spectral regions above 1200 A and down to 400 A are described which employ a series of diodes calibrated against electron synchrotron radiation as well as other radiometric standards. Improvements in photon-detection sensitivity achieved with the aid of pulse-counting electronics and multispectral detectors are reported, and the technique of precise subarcsecond telescope pointing is briefly noted. Some observational results are presented which demonstrate the advantages and precision of the instruments and techniques considered.

Moos, H. W.↗

New experiments selected for 1980 operational shuttle flight

Experiments selected for NASA's Long Duration Exposure Facility mission are described. Technical areas represented by the experiments include materials, thermal control coatings, detectors, power, micrometeoroids, electronics, lubrication, optics, and space debris detection.

Source record↗

The High Resolution Imaging Instrument for HEAO-B

The High Resolution Imaging Instrument for the HEAO-B X-ray Telescope satellite is designed to reproduce images of celestial X-ray sources in the range of 0.2 to 4.0 keV. It provides both imaging and temporal data. The basic detector is a two-stage microchannel plate with a crossed-grid charge detector. Preamplifiers, detector bias supplies, and some processing circuits are colocated with the detector. The remaining electronic circuits are located in a remote central electronic assembly. The processing system is designed for single-photon processing. The imaging data rate is limited to 100 data points per second. Non-imaging total-field count rate is acquired with a maximum dead time of 14 microseconds per event.

Kubierschky, K.↗

Ultraviolet spectrometer/polarimeter

Improved satellite instrument package consists of telescope, spectrometer with polarimeter, five detectors, and control electronics. Instrument is designed to study solar ultraviolet radiation. Polarimeter will determine four Stokes parameters and possible mechanisms for producing linear and circular polarization. Density measurements of Earth's upper atmosphere constituents are possible.

Source record↗

Hourly average values of solar wing parameters (flow rate and ion temperatures) according to data of measurements of the Venera-9 and Venera-10 automatic interplanetary stations on an Earth-Venus during the period June 1975 - April 1976

Four electrostatic analyzers with channel electron multipliers as detectors were used to measure solar wind ionic flow. The axes of the fields of vision of two of these analyzers were directed along the axis of the automatic interplanetary station, oriented towards the Sun, while the other two were turned in one plane at angles of +15 deg and -15 deg. The full hemisphere of the angular diagram of each analyzer was approximately 5 deg. The energetic resolution was approximately 6%, and the geometric energy was 0.002 sq cm ave. keV. Each analyzer covered an energetic range of approximately 10 in eight energetic intervals. Spectral distributions were processed in order to obtain the velocity and temperature of the protons. Tabular data show the hour interval (universal time) and the average solar wind velocity in kilometers per second.

Vaysberg, O. L.↗

A study to identify research issues in the area of electromagnetic measurements and signal handling of remotely sensed data

Research issues in the area of electromagnetic measurements and signal handling of remotely sensed data are identified. The following seven issues are discussed; platform/sensor system position and velocity, platform/sensor attitudes and attitude rates, optics and antennas, detectors and associated electronics, sensor calibration, signal handling, and system design.

Source record↗

High Resolution Imager (HRI) for the Roentgen Satellite (ROSAT) definition study

The design of the high resolution imager (HRI) on HEAO 2 was modified for use in the instrument complement of the Roentgen Satellite (ROSAT). Mechanical models of the front end assembly, central electronics assembly, and detector assembly were used to accurately represent the HRI envelope for both fit checks and focal plane configuration studies. The mechanical and electrical interfaces were defined and the requirements for electrical ground support equipment were established. A summary description of the ROSAT telescope and mission is included.

Source record↗

Design and fabrication of a CCD camera for use with relay optics in solar X-ray astronomy

Configured as a subsystem of a sounding rocket experiment, a camera system was designed to record and transmit an X-ray image focused on a charge coupled device. The camera consists of a X-ray sensitive detector and the electronics for processing and transmitting image data. The design and operation of the camera are described. Schematics are included.

Source record↗

An EAS experiment at mountain altitude for the detection of gamma-ray sources

The plan of an extensive air shower experiment 2.200 m above sea level for the detection of 10 to the 14th power eV to 10 to the 17th power eV gamma rays from sources in the declination band 0 deg to + 60 deg is described. The site selection, detector array and electronic layout are detailed.

Allkofer, O. C.↗