Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Transforming energy using quantum dots

Transforming and directing the flow of energy from one form (e.g., sunlight, electricity, etc.) to other useful forms of energy (e.g., electricity, chemical bonds, light, etc.) in an efficient and controllable manner is critical to meet the increasing energy demands and build a sustainable society. In search of such energy mediators, colloidal semiconductor nanocrystals, or quantum dots (QDs) are promising building blocks for building and designing systems that can efficiently capture light and convert and direct that energy into other useful forms of energy. In this work, we summarize recent advances using QDs in energy conversion architectures with the express goal of converting optical energy to other forms of energy, including electricity (i.e., photovoltaics) , photons with different energies (i.e., photo up- or downconversion), and chemical bonds (i.e., photocatalysis). The advantages of employing QDs over molecular chromophores in absorbing and then directing and converting optical energy are highlighted. Finally, we discuss ongoing challenges as well as unique opportunities associated with the use of QDs for transforming energy.

30 DIRECT ENERGY CONVERSION↗

The importance of sulfonate to the self-doping mechanism of the water-soluble conjugated polyelectrolyte PCPDTBT-SO 3 K

The conjugated polyelectrolyte poly[2,6-(4,4-bis-potassium butanylsulfonate-4H-cyclopenta-[2,1-b;3,4-b']-dithiophene)-alt-4,7-(2,1,3-benzothiadiazole)] (PCPDTBTSO 3 K, or CPE-K) is part of a unique class of organic semiconducting polymers that are soluble in water and become doped in the presence of a proton source. One of these proton sources is water, which CPE-K is exposed to during purification by dialysis, allowing for its immediate use without an additional doping step. Previous studies have suggested that the actual dopant is H + , and that the addition of sodium hydroxide to CPE-K reverses the process and de-dopes the polymer. Curiously, the majority of these water-soluble self-doped polymers in the literature contain a pendant sulfonate group. However, a detailed study to gain insight into the importance of the sulfonate group in water-soluble self-doped polymer systems is lacking, despite its widespread presence in the literature. In this work, using Fourier-transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), and ultraviolet-visible-near infrared (UV-vis-NIR) absorption spectroscopy, we are able to elucidate the role of the pendant sulfonate group with regards to the fundamental doping mechanism of CPE-K. Specifically, we found the CPDT unit can be protonated by water, which is due to both the stabilizing influence of the sulfonate group, and the relatively high oxidation potential of the CPDT unit, both of which are required for self-doped water soluble polymer systems. Furthermore, we estimate the doping efficiency of CPE-K using electrical measurements and X-ray reflectivity (XRR), and reveal several different methods for the doping and de-doping of this material, showcasing this particular material's superior versatility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of minnealloy fabrication via three routes

Transformer cores exhibiting higher operating power and improved efficiency are of great interest to electrical utilities, industry, and the de-carbonization effort. Minnealloy, α″-Fe16(C,N)2, a martensite made only of iron, nitrogen, and carbon, has shown the largest saturation magnetization of any soft ferromagnet, 250 emu/g, and tunable magnetocrystalline anisotropy. Given this represents a significant increase in power transferred per cycle compared to legacy transformer core materials, we investigate three novel, industrially scalable routes for fabricating Minnealloy. The martensite phase content is investigated for each route. Vibrating sample magnetometry is used to investigate the change in saturation magnetization and coercivity with respect to the relative content of the desired phase and other iron, iron-nitride, and iron oxide phase impurities. The relationship between structure and magnetic properties of bulk α″-Fe16(C,N)2 is investigated using LDA, PBE, and PBEsol exchange-correlation functionals within the frameworks of Hubbard-corrected density functional theory (DFT+U).

36 MATERIALS SCIENCE↗

Equity in Transactive Energy Systems

Transactive energy (TE) research primarily focuses on efficient and reliable operation of the electricity grid by using economic or market-based constructs to incorporate significant amounts of responsive, demand-side assets. This research examines the literature to evaluate if the design of TE demonstrations incorporates microeconomic principles of equity and fairness. We also consider the extent to which the design and implementation of TE affects energy inequities, and how these inequities could be addressed in future research with specific equity valuation metrics. The design of TE systems can impact energy equity across several dimensions and we provide recommendations for incorporating microeconomic principles of equity and fairness in TE system architecture as well as metrics for improving equitable outcomes in TE system design, implementation, and performance.

Energy, Transactive Energy, Economics↗

A small number of point mutations confer formate tolerance in Shewanella oneidensis

ABSTRACT Microbial electrosynthesis (MES) is a sustainable approach to chemical production from CO 2 and clean electricity. However, limitations in electron transfer efficiency and gaps in understanding of electron transfer pathways in MES systems prevent full realization of this technology. Shewanella oneidensis could serve as an MES biocatalyst because it has a well-studied, efficient transmembrane electron transfer pathway. A key first step in MES in this organism could be CO 2 reduction to formate. However, we report that wild-type S. oneidensis does not tolerate high levels of formate. In this work, we created and characterized formate-tolerant strains of S. oneidensis for further engineering and future use in MES systems through adaptive laboratory evolution. Two different point mutations in a gene encoding a predicted sodium-dependent bicarbonate transporter and a DUF2721-containing protein separately confer formate tolerance to S. oneidensis . The mutations were further evaluated to understand their role in improving formate tolerance. We also show that the wild-type and mutant versions of the putative sodium-dependent bicarbonate transporter improve formate tolerance of Zymomonas mobilis , indicating the potential of transferring this formate tolerance phenotype to other organisms. IMPORTANCE Shewanella oneidensis is a bacterium with a well-studied, efficient extracellular electron transfer pathway. This capability could make this organism a suitable host for microbial electrosynthesis using CO 2 or formate as feedstocks. However, we report here that formate is toxic to S. oneidensis , limiting the potential for its use in these systems. In this work, we evolve several strains of S. oneidensis that have improved formate tolerance, and we investigate some mutations that confer this phenotype. The phenotype is confirmed to be attributed to several single point mutations by transferring the wild-type and mutant versions of each gene to the wild-type strain. Finally, the formate tolerance mechanism of one variant is studied using structural modeling and expression in another host. This study, therefore, presents a simple method for conferring formate tolerance to bacterial hosts.

Cross, Megan C. Gruenberg (ORCID:0000000291589900)↗

Dataset for Blueprinting Electrified Transit System Implementation

This dataset contains the figures and tabulated results generated from a system-level optimization study of transit fleet electrification planning. The dataset does not include executable modeling code required to reproduce the optimization. The dataset includes results for optimized charging infrastructure deployment by location and power level and service block assignments by fuel type, battery capacity selections, and distributed energy resource sizing. It also contains aggregated financial results, capital expenditures, operating cost summaries, net present cost comparisons across scenarios, and quantified air quality impacts. Results are structured to reflect multiple planning scenarios, including heuristic electrification plans, system-optimized configurations, and sensitivity cases with alternative objective weightings. The modeling was developed using publicly available General Transit Feed Specification data from Omnitrans and standardized modeling assumptions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dataset for Blueprinting Electrified Transit System Implementation

This dataset contains the figures and tabulated results generated from a system-level optimization study of transit fleet electrification planning. The dataset does not include executable modeling code required to reproduce the optimization. The dataset includes results for optimized charging infrastructure deployment by location and power level and service block assignments by fuel type, battery capacity selections, and distributed energy resource sizing. It also contains aggregated financial results, capital expenditures, operating cost summaries, net present cost comparisons across scenarios, and quantified air quality impacts. Results are structured to reflect multiple planning scenarios, including heuristic electrification plans, system-optimized configurations, and sensitivity cases with alternative objective weightings. The modeling was developed using publicly available General Transit Feed Specification data from Omnitrans and standardized modeling assumptions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power Sector Transformation Pathways: Exploring Objectives, Factors, and Technology Innovations to Inform Power Sector Pathway Decisions

The power and heating sectors are responsible for around 30% of global CO2 emissions and this share is likely to grow as countries move towards electrification of the transportation and building sectors. Therefore, enabling forward-thinking, long term strategies in the power sector is a crucial area for international collaboration and support. The rapid transition of power systems toward modern, low-carbon pathways and technologies will be necessary to meet key climate goals while also enabling other critical objectives such as economic development, energy access, and energy system resiliency, among others. Many developed and developing countries are well-poised to champion power sector transformation (PST), however, further support is needed to identify pathways and implement critical near and long-term actions. To address this need, the Low Emission Development Strategies Global Partnership (LEDS GP) together with an expert team including Agora Energiewende, Energy Innovation, European Climate Foundation, Fraunhofer Institute for Systems and Innovation Research , Prayas Energy Group and LEDS Latin America and Caribbean Platform, developed a framework identifying four key pathways that can be integrated and combined to support low-carbon PST. These four pathways are: (1) Distributed Energy Resource Revolution, (2) Bulk Power Transformation, (3) Transmission and Distribution Interactivity, and (4) Distributed Transactional Future. To support exploration of pathways, this study examines PST objectives and factors that may lead countries or jurisdictions to place a greater relative emphasis on certain pathways as well as a framework and complementary tool for considering the emphasis in a hands on manner. The report provides case studies on application of the approach to bring life to the topic. The case studies include Haiti, Kenya, Mexico, Southeast Asia, and the European Union, among others. The report also presents actions to-be-taken in the near-, medium- and long-term to support the realization of pathways and long-term transformation of the power sector. The report, together with a complementary spreadsheet tool developed under the effort, can be used to enable stakeholder engagement and visioning for the power sector over the long-term, taking into account key factors and potential innovations. It can also be used to understand and inform relevant analysis tools and models based on which pathways are emphasized, and to identify key actions in the near- and medium-term to avoid lock-in of carbon-intensive technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluate the System-Level Impact of Connected and Automated Vehicles Coupled with Shared Mobility: An Agent-based Simulation Approach

With the rapid growth of information and communication technologies, Connected and Automated Vehicles (CAVs) are deemed to be disruptive with the potential to significantly improve overall transportation system efficiency, however, may bring Vehicle Miles Traveled (VMT) increase or other issues. Further, shared mobility systems are another disruptive force that is reshaping our travel patterns. To quantify the combined impact of CAV and shared mobility on travel behavior, traffic performance and energy efficiency, we develop a mesoscopic simulation-based framework for mobility and energy efficiency evaluation considering the disruptive transportation technologies. Under this framework, we develop novel models for energy intensity and modal activity, and evaluated a variety of energy scenarios for different combinations of CAV applications, various levels of automation, roadway characteristics, and traffic conditions, while also varying different vehicle types and fuel/powertrain technologies. Based applying this modeling suite to a calibrated BEAM simulation network in Riverside California, it was found that cooperative automated driving in general will improve mobility, but automated vehicles, even when deployed in a shared autonomous fleet, will likely bring an increase of VMT (up to 36%) due to mode shifts and deadheading. Ride-hailing vehicles typically have better energy efficiency and a higher share of electric vehicles, which helps offset the negative impact from VMT increases when estimating the system-level energy consumption. In general, simulation results show a 6% increase in energy consumption for the scenarios with an increasing shift to ride-hailing modes.

42 ENGINEERING↗

Microelectronics at the Department of Energy: Capabilities and Opportunities for Driving U.S. Competitiveness

Microelectronics are everywhere—embedded in our consumer products; underlying our power, transportation, and information infrastructure; and fortifying our national security. These and other microelectronics applications are also intricately linked with America’s energy and decarbonization goals. For instance, advanced power electronics are critical to our transition to renewable power and electric transport, and more energy-efficient computing and consumer devices are needed as energy consumption grows rapidly. Meanwhile, global supply chain disruptions beginning in 2020 and the ensuing chip shortage caused by the COVID-19 pandemic highlight the vulnerability of microelectronics supply chains. The globally distributed manufacturing base can be disrupted in unexpected ways, and there is no single solution to these challenges given the range of applications and technologies within the microelectronics industry—from ever-smaller, nanoscale feature sizes to large-scale commodity use cases to specialized functionalities. Rather, solutions will require the private sector, federal agencies, and research and development (R&D) organizations such as labs and universities to act in concert beyond their individual missions.

36 MATERIALS SCIENCE↗

Avista’s Shared Energy Economy Model Pilot: A Techno-economic Assessment

As part of the second round of the Washington Clean Energy Fund, Avista Corp received a $3.5 million matching grant in support of a shared energy economy project to test the integration of energy assets–from rooftop solar and battery storage to building energy management systems–that can be shared and used for multiple purposes. The goal of this project is to demonstrate how both the customer and the utility can benefit from this shared energy economy model and demonstrate that the electric grid can become more reliable, efficient, resilient, and flexible. Pacific Northwest National Laboratory was engaged by the U.S. Department of Energy and the Washington State Department of Commerce to work with Avista in assessing the benefits of the shared energy economy model. This report documents the techno-economic assessment of the shared energy economy model, including the definition of use cases and applications, collection and preparation of data and input parameters, development of modeling and optimization methods, and case studies and analysis results.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units

The heat pump rooftop units (RTUs) measure replaces gas furnace and electric resistance RTUs with high-efficiency heat pump rooftop units (HP-RTUs). The HP-RTUs are intended to be top-of-the line, including high-efficiency fans and heat pump systems. The fans are variable speed, allowing the HP-RTUs to operate as single-zone variable air volume systems. The heat pumps are also variable speed, allowing for high part load performance. All schedules in the existing RTUs are transferred to the new HP-RTUs for consistency. Furthermore, any energy efficiency features in the existing baseline RTUs such as energy recovery or economizers are also transferred to the new HP-RTUs for consistency. This measure is applicable to approximately 45% of the ComStock floor area. The HP-RTU measure demonstrates 10.3% total site energy savings (449 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Guanajuato Policy Options for Land Transportation Greenhouse Gas Reduction [Slides]

NREL consulted the Mexican state of Guanajuato to help them identify and prioritize policies that are specifically applicable to their land transportation system and help them meet their greenhouse gas (GHG) reduction goals. Three focus groups were held across Guanajuato to get the input from a wide variety of users of the transportation system. These focus groups performed a SWOT (strengths, weaknesses, opportunities and threats) analysis of Guanajuato's transportation system and logged the policy goals of participants. NREL then developed a menu of policy options that have been used successfully in relevant countries and prioritized these policies based on the weighted input from stakeholder groups. The most applicable policies were a paid parking strategy, regional transit master plan, and expanded bike and pedestrian infrastructure. Case studies of these three policies, plus a few more, were then presented to inform Guanajuato of how these policies could successfully be implemented. Finally, the GHG reductions for five of the most applicable policies were estimated to reduce emissions from Guanajuato's land transportation system nearly 40% below business-as-usual emissions by 2050.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hanover LED Streetlight Conversion

On May 8, 2017, Hanover residents voted overwhelmingly to transition to 100% renewable electricity by 2030 and heating, cooling and transportation by 2050. In so doing, we became the first municipality in the country to make this commitment by popular vote. To accomplish these goal town leaders developed a plan to address first transitioning municipal energy uses to renewable forms of energy, through on-site generation of the municipal electrical load, load reduction through energy efficiency improvements to town facilities and infrastructure. Significant progress has been accomplished in the generation of energy with 90%+ of the 2024 municipal load being offset by generation and through various energy efficiency projects. The utility owned street lighting was identified as a large energy consumer of 165 MWh annually (7% of the annual municipal load) due to old inefficient high-pressure sodium and mercury vapor streetlights with no ability to reduce wattage during periods with low lighting needs. The Hanover LED Streetlight Replacement Project replaced utility owned streetlights with town owned controllable (dimmable and trimmable) LED lights that can be adjusted by location and time of night. Coupled with ownership of the streetlights transfer to the town, the town’s share of the project pay back is 11 months and for the complete project including federal share the payback is approximately 3 years. With the completion of lighting upgrade, the annual streetlighting energy load has dropped by 60% to 67 MWh in the first year of operation (7/1/24 - 6/30/25). This amounts to an approximate $90,000 annual savings or a local 1% tax rate impact. Additionally, over 200,000 pounds of CO2 will be saved annually.

99 GENERAL AND MISCELLANEOUS↗

Bridging the length scales in ionic separations via data-driving machine learning

We pursued a data science driven machine learning (ML) approach that blended molecular scale attributes informed from molecular dynamics (MD) simulation and materials properties to the selectivity and energy efficiency in targeted ionic separations using electric fields. The model mixtures investigated for ionic separations are pH sensitive and include organic acids, silica and boron, transition metals, such as copper and chromium. There were two major research thrusts of this project. Firstly, we investigated surrogate models and deep learning that relate material chemistries and structures to selective transport of ionic species under applied electric fields. Secondly we investigated how the bipolar junction interfacial design and water dissociation catalyst in bipolar membranes affect reverse bias polarization behavior and pH modulation in deionization platforms as a function of the platform operating parameters (e.g., cell voltage, residence time, and salt feed concentration). As a result of this work, we also were able to start a new direction, namely ML models for molecular design of surfactants.

36 MATERIALS SCIENCE↗

Energy 101: Distributed Energy Resources and Controllable Loads [Slides]

The Energy 101: Distributed Energy Resources and Storage presentation, developed for the Energy Technology Innovation Partnership Project (ETIPP), provides an overview of distributed energy resources (DERs) and energy storage. It covers fundamental concepts, technologies, considerations, case studies, and additional resources.

14 SOLAR ENERGY↗

Seamlessly Fuel Flexible Heat Pump with Optimal Model-based Control Strategies to Reduce Peak Demand, Utility Cost and CO2 Emission

This research develops a novel hybrid fuel heat pump system for space heating of residential and small commercial buildings with built-in optimization and control. Whereas conventional dual fuel systems either run on gas or electricity at any given moment, the proposed seamlessly fuel flexible heat pump (SFFHP) simultaneously consumes gas and electricity and continuously optimizes the proportion of each. The building air flows across the heat pump condenser first and then flows across the furnace coil, and this reduces the heat pump temperature lift. The SFFHP delivers energy savings by allowing each subsystem (gas furnace and electric heat pump) to operate where it performs best to improve energy efficiency, minimize energy cost, and minimize carbon footprint. The capacities of the electric heat pump and gas furnace are continuously adjusted based on ambient conditions, utility price signals, and marginal grid emission signals. An optimal model predictive control strategy was developed with the goal of minimizing utility cost and minimizing CO2 emission. Two case studies were conducted to simulate the performance of SFFHP during the heating season in Chicago and Los Angeles, respectively. Compared with a conventional electric heat pump, SFFHP yields 33% utility cost reduction and 49% CO2 emission reduction in Chicago. Similarly, it achieves 23% utility cost reduction and 17% CO2 emission reduction in Los Angeles. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. Due to the hybrid fuel nature of this novel equipment, user comfort will always be maintained. The fuel flexibility makes it an attractive option for demand response programs.

Li, Zhenning↗