Integrated protonic ceramic electrochemical cell for sustainable energy economy using water-energy nexus framework

Reliance on fossil fuels will continue for the next decades even though there are global pushes away from it to mitigate the overarching climate challenge, most especially by its highest consumers and availability. While there is a hastening global shift away from fossil fuel, integrating its assets into this technology helps limit the risk and future losses of stranded assets and reduce the cost of investment in the new technologies. Moreover, the generation of electricity from intermittent renewable sources like solar and wind has witnessed a significant surge in recent years, leading to a pressing demand for practical energy storage systems. Electrical energy storage is anticipated to play a pivotal role in the future global energy system, facilitating load-leveling operations to support the greater integration of renewable and distributed generation. Reversible electrochemical cells (RECs) offer a promising option for addressing the fossil fuel assets integration and energy storage challenges through the interconversion between electrical and chemical energy and concurrent utilizing carbon emission. In their electrolysis mode, the RECs convert electricity into durable, storable, and portable valuable chemical fuels such as syngas and methane. Conversely, the produced chemical fuels can be used as reactants in the fuel cell mode to generate electricity on demand with minimal (hydrocarbons) or zero when H2 or NH3 is used emissions. However, a challenging goal for this type of technology remains to achieve optimal operation and high roundtrip efficiencies, which has hindered the deployment of previous electrochemical cells. This dissertation demonstrates how reversible protonic ceramic electrochemical cells (RePCECs) can be integrated with fossil fuel power plants and renewable energy sources as a potential energy storage system. In this work, integrated RePCEC systems are designed and examined using computational modeling at scales to determine appropriate system configurations and operating conditions that achieve high roundtrip efficiencies. Cell level design of the PCEC is the first approach, several cells are assembled for the stack level model that is integrated into combined cycle powerplant and solar photovoltaic for the system level model. After critical literature review, this answered the operational and integration research questions proposed to address these challenges. The designed systems perform two functions, utilizing captured CO2 and storing renewable energy through co-electrolysis of steam and CO2. The co-electrolysis reaction involves endothermic water electrolysis and exothermic methanation reaction. To enhance high roundtrip efficiency, there is a need for thermal balance and management in the electrolysis mode. This involves operating the RePCEC stack under conditions that favor methane production to balance out heat needed by water electrolysis, it crucial for the RePCEC system operation. Methanation is enhanced by low temperatures. Leveraging on fabricated BCZYYb-electrolyte RePCEC, the cell model designed revealed that the optimum temperature for methane production is 450℃ at atmospheric pressure. Thus, to achieve optimum system performance, operating in the temperature range 450-525℃ is recommended at the given configuration, combining between the optimum temperature for methane production and temperature for the optimum stack roundtrip efficiency. Configuration with carbon capture system and purge stream is the optimum configuration from the seven conceptualized and evaluated. The modeling outcomes include a thermodynamic examination of integrated RePCEC systems, calibration of cell and stack level models, and steady-state simulation and integration into a 600MW combined cycle power plant retrofitted with two two-stage membrane-based carbon capture system and a wastewater treatment and recovery unit. At 100% powerplant loading, the stack and system roundtrip efficiencies are 72% and 51.37% respectively. Adding a purge stream for produced hydrogen at the system downstream improves the efficiencies to 74 and 55.48% respectively. At atmospheric pressure and 525℃, the system model suggests that a stack roundtrip of 82% is achievable, and overall system efficiency increases by reducing the energy consumption by the balance of plant components for steam generation and storage. Economic analysis of the process gives levelized cost of methane as $2.24/MMBtu lower than the conventional production route that range between $3.46/MMBtu and $9.85/MMBtu. The lifecycle analysis shows that the global warming potential for the production of methane and hydrogen from the RePCEC system is 3.83 kg CO2 eq which is lower than 9.35 kg CO2 eq emission during steam methane reforming for hydrogen production. This answered both the environmental and economic concerns in the raised research question. The proposed RePCEC configuration and analysis carried out in this dissertation to address the surge in renewable energy and challenges with PCEC technology hold significant potential in achieving large-scale energy storage while simultaneously reducing carbon emissions. These advancements, coupled with suitable governmental policies and incentive programs, have the potential to economically disrupt the natural gas industries by using RePCEC systems for methane production, thereby making them more favorable for eventual implementation and commercialization.

25 ENERGY STORAGE↗

Electric Grid and Markets 101 [Slides]

This presentation covers aspects of operating the bulk power system with a focus on the regulatory levels of the US grid at a pretty introductory level. It was meant ot help inform a request from USDA for a "101" presentation that spoke to how electricity markets, contracting and regulation interact with the engineering and physics of operating the bulk power system. They are presently moving to being able to more directly fund PPAs or other non-co-op owned assets for member co-ops, is my understanding.

24 POWER TRANSMISSION AND DISTRIBUTION↗

County Electric Vehicle Home Charging Access Shares from the 2030 National Charging Network Study

This file contains modeled county-level home electric vehicle (EV) charging access shares from the study, "The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure" by Wood et al. (2023). These are based on modeling in "There's No Place Like Home: Residential Parking, Electrical Access, and Implications for the Future of Electric Vehicle Charging Infrastructure" by Ge et al. (2021). Wood, Eric, et al. 2023. The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure. Golden, CO: National Renewable Energy Laboratory. NREP/TP-5400-85654. https://www.nlr.gov/docs/fy23osti/85654.pdf . Ge, Yanbo, et al. 2021. There's No Place Like Home: Residential Parking, Electrical Access, and Implications for the Future of Electric Vehicle Charging Infrastructure. Golden, CO: National Renewable Energy Laboratory. NREL/TP-5400-81065. https://www.nlr.gov/docs/fy22osti/81065.pdf .

24 POWER TRANSMISSION AND DISTRIBUTION↗

An integrated approach to optimizing concentration shock wave electrodialysis using 2D multicell simulation and response surface models

Shock wave electrodialysis (SWED) is a highly promising technique for energy-efficient ion separation in the context of a circular economy. This paper presents a approach way of modeling and improving SWED using a two-dimensional multicell model combined with the COMSOL program and response surface methodology. The model integrates the Nernst-Planck equation, Darcy's law, and first-order electroosmosis to examine the local concentration, flux of ionic species, distribution of current, and velocity of flow in SWED cells under various operating conditions. We first illustrate the clear depiction of concentration, velocity, and electric potential distribution through contours which aids in identifying optimal operating conditions and designing scalable SWED systems. The results emphasize the significance of surface charge density and voltage in influencing the features of shock waves for obtaining effective ion separation while optimizing energy consumption and improving current efficiency by controlling the retention time of feed flow. Here, this study defines two crucial characteristics of shock waves, namely the length of the flat depletion zone of a fully developed shock wave (shock wave height) and the distance of shock wave propagation (shock wave length). These properties significantly impact separation performance, as determined by the simulation results. Additionally, the response surface methodology is incorporated with the COMSOL models to develop predictive models and graph responses, enabling a more comprehensive understanding of the interactions between parameters and performance indicators, such as removal ratio, energy consumption, and water recovery. Finally, this work suggests design tactics for expanding SWED processes and outlines potential areas for further research. This research provides valuable insights into the prospective applications, design optimization, and scalability of SWED in the field of electrokinetic separation technologies for green chemistry and a circular economy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen Transportation and Distributed Energy Systems Seismic Risk Assessment for Cascadia Subduction Zone Airport Facilities

Portland International Airport in Oregon is exploring operating a fleet of 28 fuel cell electric buses to support airport operations and possibly provide backup power during outages. In this report, we evaluate the risk of hydrogen deployment at an airport considering the potential for seismic activity. We present a seismic risk assessment for pressurized piping for a generic hydrogen refueling station at the airport. Only pressurized piping was considered in the risk analysis because of its vulnerability and availability of fragility information unlike the other components. Seismic capacity of other components should be included as more information becomes available.

08 HYDROGEN↗

​​Hydrogen Transportation and Distributed Energy Systems Seismic Risk Assessment for Cascadia Subduction Zone Airport Facilities​

Portland International Airport in Oregon is exploring operating a fleet of 28 fuel cell electric buses to support airport operations and possibly provide backup power during outages. In this report, we evaluate the risk of hydrogen deployment at an airport considering the potential for seismic activity. We present a seismic risk assessment for pressurized piping for a generic hydrogen refueling station at the airport. Only pressurized piping was considered in the risk analysis because of its vulnerability and availability of fragility information unlike the other components. Seismic capacity of other components should be included as more information becomes available. To characterize the seismic hazard, we considered the initiating event frequency of a Cascadia Subduction Zone earthquake event based on data from the literature. Seismic stressors that translate to the site from an earthquake event are expressed as peak ground acceleration. Site disturbance is characterized as a function of soil conditions, represented by different shear wave velocity values, which affect how seismic waves propagate and impact structures. Pipe fragility curves as a function of seismic capacity were used to correlate ground acceleration and failure probability. These fragility characteristics were combined with site-specific soil conditions to calculate the probability of pipe rupture during a seismic event. It should be noted that multiple simultaneous failures due to an earthquake event as a common cause are not considered. Some epistemic uncertainties such as self-exciting shocks, aftershocks, and the time variant nature of the ground motion are not considered either.

08 HYDROGEN↗

Distributed Wind Certification Best Practices Guideline: January 16, 2023-January 15, 2026

This Distributed Wind (DW) Certification Best Practices Guideline describes the typical approach for certification of distributed wind turbines above and below 150 kilowatts (kW) in size based on the conformity assessment requirements in the United States. The purpose of the guideline is to clarify and consistently describe the complex path to certification for various systems and components. This is done via clarification of both the required turbine type certification elements, as well as third-party electrical safety listing of turbine system components and subassemblies.

17 WIND ENERGY↗

It's All About the Envelope: Prioritizing Envelope Upgrades for Electrification of Cold Climate Homes

Building decarbonization via electrification on a clean grid is the most promising climate solution proposed to date for the building sector. In cold climate zones, building electrification will be driven in large part by moving from natural gas space heating to cold climate heat pumps (CCHPs). CCHPs are commercially available today, including economical cold climate air source heat pumps (ccASHPs). But there's one big problem - wide-scale adoption of ccASHPs will dramatically increase winter peak electricity demand, even with the highest efficiency ccASHP products. Furthermore, cold climate space heating loads will drive unprecedented electric system peaks during the lowest periods of renewable generation and are likely to overwhelm existing distribution systems. This scenario is avoidable by coupling electrification with building envelope upgrades to reduce peak heating loads. This paper presents a model, built from home energy audit and research data sets, that quantifies the above challenges. Results demonstrate how weatherization efforts coupled with additional high-performance envelope upgrade measures can prepare the building stock for electrification and show the benefit these measures can bring to future utility operations. Much of this envelope upgrade work is cost-effective, according to conservative cost-benefit testing and program successes to date, and is coupled with substantial non-energy benefits. However, persistent market barriers have made scaling of envelope retrofit work challenging for decades, suggesting additional policy support is required. Lessons learned from previous policy experience, combined with new technology and administrative support, create exciting potential for this decarbonization climate solution.

air sealing↗

Evaluating the Impact of Managed EV Charging for Reliable Operation of Bulk Power Systems with High Non-Dispatchable Generation

The growth of electric vehicles (EVs) and variable-generation (VG) sources introduces new challenges for power-system operations. This study introduces a modeling framework and evaluates five EV charging strategies under projected 2040 grid conditions in the Evergy service territory with high non-dispatchable generation. Using realistic EV behavior and generation models, their impacts on system peak demand, ramp rate, and reserve capacity are evaluated. Results show that only the peak-avoidance strategy effectively reduces system peak demand, while decentralized strategies-particularly cost based dynamic charging-can exacerbate peaks due to synchronized user behavior. However, ramp-rate minimization strategy significantly reduce the stress on dispatchable generation achieving the lowest maximum absolute ramp rate (MARR) (56.81 MW) and lowest reserve requirement (2.39 GW). In contrast, unmanaged and TOU random strategies increase the stress on dispatchable generation sources with increased MARR and reserve requirements. These findings highlight the importance of coordinated, system-aware managed charging strategies to ensure reliable and affordable grid operation in the presence of EVs and VG sources.

14 - SOLAR ENERGY↗

Incentivizing Distributed Energy Resource Participation in Grid Services

The bulk power system is experiencing a dramatic shift as renewable generation growth continues to accelerate. Large-scale renewables adoption will help societies transition to a low-carbon, low-cost, and environmentally friendly electrical power system. However, the transition from a paradigm of generation following load to one where load follows generation will require large-scale interconnection and coordinated operation of Distributed Energy Resources (DERs), supported by open communication protocols. In this future grid scenario, DER aggregations will provide critical grid services that enable high penetration levels of renewable generation. This position paper presents an Energy Service Interface (ESI) that defines scope for ensuring secure, trustworthy information exchange between grid service providers and DERs. The goal of the ESI is to encourage large-scale participation of DERs in order to provide grid services through dispatch of DER aggregations. This position paper also presents an open smart energy communications protocol that allows DERs to advertise their characteristics and participate in grid services, within constraints established by the ESI. The paper presents several monetization incentives that grid service providers could use to encourage large-scale DER participation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Joint Estimation of Behind-the-Meter Solar Generation in a Community

Distribution grid planning, control, and optimization require accurate estimation of solar photovoltaic (PV) generation and electric load in the system. Most of the small residential solar PV systems are installed behind-the-meter making only the net load readings available to the utilities. This paper presents an unsupervised framework for joint disaggregation of the net load readings of a group of customers into the solar PV generation and electric load. Our algorithm synergistically combines a physical PV system performance model for individual solar PV generation estimation with a statistical model for joint load estimation. The electric loads for a group of customers are estimated jointly by a mixed hidden Markov model (MHMM) which enables modeling the general load consumption behavior present in all customers while acknowledging the individual differences. At the same time, the model can capture the change in load patterns over a time period by the hidden Markov states. The proposed algorithm is also capable of estimating the key technical parameters of the solar PV systems. Our proposed method is evaluated using the net load, electric load, and solar PV generation data gathered from residential customers located in Austin, Texas. Testing results show that our proposed method reduces the mean squared error of state-of-the-art net-load disaggregation algorithms by 67%.

behind-the-meter solar generation↗

Valuing Resilience Benefits of Microgrids for an Interconnected Island Distribution System

Extreme climate-driven events such as hurricanes, floods, and wildfires are becoming more intense in areas exposed to these threats, requiring approaches to improve the resilience of the electrical infrastructure serving these communities. Long-duration outages caused by such high impact events propagate to economic, health, and social consequences for communities. As essential service providers, electric utilities are mandated to provide safe, economical and reliable electricity to their customers. The public is becoming less tolerant to these more frequent disruptions, especially in view of technological advances that are intended to improve power quality, reliability and resilience. One promising solution is state-of-the-art microgrids and the advanced controls employed therein. This paper presents and demonstrates an approach to technoeconomic analysis that can be used to value the avoided economic consequences of grid resilience investments, as applied to the islands of Vieques and Culebra in Puerto Rico. This valuation methodology can support policies to incorporate resilience value into any investment decision-making process, especially those which serve the public interest.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EMP-Resilient Electric Grid Transformer Analysis

The response of a high - voltage (HV) transformer to fast rise time voltages, such as that from a electromagnetic pulse (EMP) can result in interruption of power distribution and possibly system failure. To help identify these potential occurrences, it is necessary to develop a transformer model that not only captures the input/output response of the transformer but also the internal behavior. The model constructed should cover the frequency band of interest while capturing the internal physical and electrical characteristics. This broad-band, high-fidelity model would enable the prediction of unwanted effects through simulation. A proposed modeling scheme for a HV transformer is described in Part 1 of this report. Part 2 of this report details assessments of internal voltage and electrical field holdoff testing of transformer insulation dielectric breakdown, including comparison of low frequency (DC/60 Hz) holdoff to rise times characteristic of lightning (1 s) and EMP E1 transients (10 - 30 ns). This initial project is a path toward establishing electrical grid transformer failure criteria for EMP voltage transients. We developed modeling methods and measured breakdown electrical field statistical distributions for direct current, 60 Hz, lightning and EMP characteristic voltage rise times. Methods of nanosecond-scale capacitive discharge unit high voltage source development, suggestions for derating of 60 Hz insulation maximum electrical fields for EMP nanosecond pulse voltage withstand rating, and potential methods for increasing transformer resilience to such fast rise time pulses are described.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Remote monitoring system

A remote monitoring system for monitoring parameters of an underground asset, such as an electric cable system, a pipeline serving as a conduit for water, gas, oil, sewage, or the like. Parameter detectors, such as sensors that measure temperature, voltage, current, moisture, etc., are distributed along the asset to provide electrical signals that represent respective monitored parameters of the asset. An underground hub disposed in an underground vault, or manhole, through which the asset passes is coupled to the parameter detectors to acquire the signals provided by the parameter detectors. The hub includes a controller to provide data derived from the acquired signals, the data being transmitted to a remote central location by a transceiver, or modem, via LP-WAN communication. Signals from the transceiver are transmitted directly from underground.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On Distribution Grid Optimal Power Flow Development and Integration

Due to changes in electric distribution grid operation, new operation regimes have been recommended. Distribution grid optimal power flow (DOPF) has received tremendous attention in the research community, yet it has not been fully adopted across the utility industry. Our paper recognizes this problem and suggests a development and integration procedure for DOPF. We propose development of DOPF as a three step procedure of 1) processing the grid, 2) obtaining a tractable solution, and 3) implementing multiple solution algorithms and benchmarking them to improve application reliability. For the integration of DOPF, we demonstrate how a DOPF federate may be developed that can be integrated in a co-simulation environment to mimic the real-world conditions and hence improve its practicality to be deployed in the field. To demonstrate the efficacy of the proposed methods, tests on IEEE 123 bus system are performed where the usage of tractable formulation in DOPF algorithm development and its comparison to the benchmark solution are demonstrated.

Hanif, Sarmad↗

Scalable Unit Commitment with Security Constrained AC Power Flow via ADMM and Hybrid Modeling Strategies

This research introduces a more efficient way to optimize power grid operations, breaking the problem into manageable steps and using advanced mathematical techniques to speed up calculations. By incorporating smart heuristics, improved preprocessing, and contingency analysis, the approach allows operators to make better decisions faster. These innovations enhance our understanding of how to optimize energy generation, making it possible to anticipate failures before they happen, reduce system costs, and improve overall grid performance. Ultimately, this research helps bridge the gap between theoretical models and real-world applications, paving the way for a smarter, more resilient power grid. This research directly benefits the public by making electricity more affordable, reliable, and sustainable. By improving how power grids schedule and distribute electricity, the project helps energy providers reduce operational costs, which can lead to lower electricity prices for consumers. Additionally, the ability to predict and prevent power system failures enhances grid reliability, reducing the likelihood of blackouts that can disrupt homes, businesses, and critical infrastructure such as hospitals. From an environmental perspective, optimizing power generation reduces energy waste and lowers carbon emissions, contributing to cleaner air and a more sustainable energy system. Furthermore, with extreme weather events becoming more frequent, these advancements make the power grid more resilient, ensuring communities are better prepared for emergencies and natural disasters. By strengthening the nation's energy infrastructure, this research plays a crucial role in improving economic stability, public safety, and environmental sustainability.

24 POWER TRANSMISSION AND DISTRIBUTION↗