Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources: Preprint

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Community-Based Transactive Coordination Mechanism for Enabling Grid Edge Systems

The changing landscape of the electricity industry, characterized by a surge in distributed energy resources (DERs) and proactive customers, necessitates practical solutions for coordinated operations especially at the distribution-level. This paper introduces a community-based transactive coordination mechanism designed to incentivize customers for providing localized and system-level services reflected through real-time prices. The work presents a bidding approach for communities with DERs, such as solar photovoltaic (PV) and battery energy storage systems (BESS), to formulate their price-responsiveness for retail energy coordination, emphasizing a community-centric model. By sending bidding curves to a third-party, the mechanism enables customers with DER assets to actively participate in localized coordination with the load serving entity (LSE), thereby supplementing each other’s and even the utilities needs through a shared energy economy. The proposed transactive mechanism is implemented leveraging a co-simulation framework that integrates a distribution grid simulator and Python-based agents for performance evaluation. Collaboration with a local utility to access real distribution feeder models and consumption profiles yields simulation results demonstrating the potential to reduce costs by 12\% for communities with DERs like PV and BESS.

Community-based coordination, grid-edge systems, R↗

EV Charging Infrastructure Energization An Overview of Approaches for Simplifying and Accelerating Timelines to Processing EV Charging Load Service Requests

The United States has seen significant growth in electric vehicle (EV) adoption, leading to increased demand for EV charging infrastructure. Over the past decade, EV charging infrastructure site developers, site hosts, and electric distribution utilities have navigated the process to integrate chargers onto the electric grid. Site developers and site hosts have raised the alarm that the integration process for high-powered EV charging projects does not meet the needs of the EV market for timeliness or cost. High-powered charging stations typically require a load service request or an agreement with the local utility to connect to the grid. The process of energizing a new high-powered charging site can be complex and time-consuming, often taking up to 2 years. This timeline is the result of current utility energization processes having been designed for construction projects that take longer to build (i.e., buildings). The specific challenges stem from various factors, including compartmentalization in application processes, the integration of EV charging process approvals with other distributed energy resources (DERs), and the need to ensure grid reliability. The energization process needs to evolve to meet the growing demand for high-powered EV charging. This white paper compiles information gathered through various conversations with key stakeholders, including utilities, utility regulators, EV charging operators, site developers, and authorities having jurisdiction (AHJ) as well as through an extensive literature review. This document identifies the challenges and provides potential solutions to streamline the process of connecting EV charging infrastructure to the power grid in the United States, serving as a starting point for future conversations around these solutions. The solutions noted in this white paper require collaborative efforts among utilities, regulators, and EV charging infrastructure developers to streamline the grid connection process for EV charging infrastructure. They are broadly organized into four areas: 1. Increase data access and transparency: Develop automated load service request tools, integrate hosting capacity and load service request analyses, incorporate EV adoption forecasts, and provide transparency on the processing queue. 2. Improve energization processes and timing: Create fast-track options based on prescreening criteria, provide flexibility or phased approvals in the load service request/interconnection process, build internal knowledge within utilities about EV charging technologies, and provide standardized workforce training. 3. Promote economic efficiency: Right size distribution components to accurately reflect the load requirements of EV charging infrastructure, make proactive investments in grid infrastructure based on EV adoption forecasts and growth projections, and consider energy equity and environmental justice factors such as equitable access to EV charging when planning infrastructure. 4. Improve grid reliability and resilience: Use load management/power control systems (PCS) at EV charging stations, adopt and implement harmonized standards for communication protocols and information models between the EV charging and grid control infrastructure, and address cybersecurity considerations by implementing robust security measures and standards for EV charging infrastructure—with particular emphasis on clarifying the security requirements for the interface to the grid. The objective of the solutions proposed in this white paper is to accelerate the timeline and decrease costs associated with connecting EV charging infrastructure to the grid. Electric utilities, utility regulators, EV charging infrastructure developers, and site hosts will first need to understand which solutions are available in their service territory, and if warranted, which combination of solutions would support their specific needs. Through the successful implementations of solutions at scale detailed here, industry will demonstrate a new and innovative ecosystem where timely deployment and energization of EV charging infrastructure with greater grid resiliency and reliability is a reality.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced eLectrical Bus (ALBus) CubeSat: From Build to Flight

Advanced eLectrical Bus (ALBus) CubeSat is a technology demonstration mission of a 3-U CubeSat with an advanced digitally controlled electrical power system and novel use of Shape Memory Alloy (SMA) technology for reliable deployable solar array mechanisms. The primary objective was to advance the power management and distribution (PMAD) capabilities to enable future missions requiring more flexible and reliable power systems with higher output power capabilities. Goals included demonstration of 100W distribution to a target electrical load, response to continuous and fast transient power requirements, and exhibition of reliable deployment of solar arrays and antennas utilizing re-settable SMA mechanisms. The power distribution function of the ALBus PMAD system is unique in the total power to target load capability, as power is distributed from batteries to provide 100W of power directly to a resistive load. The deployable solar arrays utilize NASA’s Nickel-Titanium-Palladium-Platinum (NiTiPdPt) high-temperature SMAs for the retention and release mechanism, and a superelastic binary NiTi alloy for the hinge component. The project launched as part of the CubeSat Launch Initiative (CLI) Educational Launch of Nanosatellites (ELaNa) XIX mission on Rocket Lab’s Electron in December 2018. This paper summarizes the final launched design and the lessons learned from build to flight.

Deboshri Sadhukhan↗

Communication enabled fast-acting imbalance reserve

A system and method for control of dispatchable resources on an electrical power distribution grid is disclosed. The disclosed method provides improved response to power imbalance based on a communications signal independent of system frequency. The communication signal provides a feed-forward control of dispatchable power resources. A communications network is employed to generate a signal to dispatchable resources that a power imbalance has occurred. Due to fast response power transmission network interfaces associated with the dispatchable resources, the respective resources respond in significantly less time than feedback controlled conventional generators which depend on line frequency sensing. The rapid response mitigates the impact of power imbalances and enables greater penetrations of converter-interfaced power generation units such as renewable energy sources to be connected to the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The ERDA/LeRC Photovoltaic Systems Test Facility

The ERDA/LeRC Photovoltaic Systems Test Facility (STF) provides a vital support function to the overall ERDA National Solar Photovoltaic Program. It allows preliminary investigation and checkout of components, subsystems, and complete photovoltaic systems before installation in actual service. The STF can also be used to determine optimum system configurations and operating modes. A facility description is presented, taking into account the solar cell array, the energy storage equipment, the power conditioning equipment, electric utility distribution network and loads, and instrumentation and data acquisition systems. Safety procedures which have been set up for maintenance and inspection of the solar array are discussed. Attention is also given to a number of investigations regarding the effect of environmental factors on solar cell array operation.

Forestieri, A. F.↗

Distribution System Research Roadmap; Energy Efficiency and Renewable Energy

The scope of the U.S. Department of Energy's Energy Efficiency and Renewable Energy (EERE) office covers a number of distributed energy resource (DER) technologies, including distributed photovoltaics, smart buildings, wind, water, behind-the-meter-storage, and electric vehicles. The impact of these technologies on the distribution system is often assessed with an individual technology focus. Similarly, different technology offices often leverage different sets of tools, leading to analyses that are not comparable. EERE sought the ability to assess the impact of integrating multiple DER technologies, and to comprehensively address DER integration challenges across the portfolio of EERE technologies. This project built on existing work understanding technical challenges, mapped out the key research questions, assessed relevant capabilities across the national laboratory network, identified key gaps, and produced a research roadmap to inform EERE investment decisions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Development of Prototypical District-Scale Models

The U.S. has set the climate goal to achieve net-zero greenhouse gas emissions by 2050. District-scale solutions, which include scale-specific opportunities for energy and emissions savings, can be investigated and implemented to help accelerate decarbonization and progress toward this goal. However, there is currently a lack of district-scale models of buildings and community energy systems that can be used to evaluate potential district-scale technologies and strategies across a range of representative community types. This initial work aims to define and develop prototype district models that can be adapted to support the planning, design, and operation of buildings and energy systems in districts considering the complexity and interactions of diverse building loads, weather impacts, distributed energy resources (e.g., PV, EV, electric and thermal energy storage), electric and thermal grid systems, and pricing signals. An overall workflow for developing these prototype district models is established. Stakeholders and potential users of the prototype district models provided technical feedback. The specifications of the selected high priority districts were defined and documented in a scorecard format. An example prototype district model was implemented with the URBANopt platform workflows. A case study was performed to demonstrate the model application.

building energy modeling↗

Advancing Transportation Efficiency and Electric Vehicles in Tonga: A Review of Relevant Trends, Best Practices, and Future Work

Tonga is facing a transportation sector characterized by private passenger vehicles, poorly maintained roads and walkways, and an inadequate public transit system. By understanding detailed global and regional trends for transport energy efficiency and electric vehicles (EVs) within this context, the Government of Tonga can proactively plan its future transportation systems. In addition to global and regional trends, this presentation also briefly examines Tonga's own transportation policies and actions. Jurisdictions leading in EV adoption have implemented policies such as reducing taxes on EVs compared to internal combustion engine (ICE) vehicles, providing subsidies and rebates for EV charger installation, instituting an age limit on imported ICE vehicles, and developing EV maintenance courses to expand the skill set of current automotive technicians. This presentation was developed for the Pacific Islands Workshop on Electric Mobility, held from November 28th to November 30th 2022 in Fiji. NREL presented virtually and the conference was sponsored by the Pacific Centre for Renewable Energy and Energy Efficiency (PCREEE).

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

The Use of Software Agents for Autonomous Control of a DC Space Power System

In order to enable manned deep-space missions, the spacecraft must be controlled autonomously using on-board algorithms. A control architecture is proposed to enable this autonomous operation for an spacecraft electric power system and then implemented using a highly distributed network of software agents. These agents collaborate and compete with each other in order to implement each of the control functions. A subset of this control architecture is tested against a steadystate power system simulation and found to be able to solve a constrained optimization problem with competing objectives using only local information.

autonomous control↗

Introduction to Microgrids

A microgrid is simply a typical power system that has distributed energy resources (DERs), like small diesel generators, with loads in the network. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. One key factor that differentiates microgrids from a typical distribution grid is its ability to disconnect itself in the event of a blackout and sustain its loads through DERs. Microgrid systems will reconnect to the main grid when the grid comes back up. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. This presentation discusses the typical key steps involved in microgrid planning, installation, operation in a interoperable and interconnectable fashion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Based Resilience Enhancement Strategies for Electric-Gas Systems Against Sequential Extreme Weather Events

Some extreme weather events, such as the hurricane, pass through an area sequentially and thus are called sequential extreme weather events (SEWEs). This paper proposes a data-based robust optimization (RO) model to enhance the resilience of the integrated electricity and gas system (IEGS) against SEWEs. Specifically, the SEWE strikes the IEGS sequentially. After each attack, the system state is adjusted immediately to minimize the maximized expected system cost caused by the SEWE. The attack-defense procedures are repeated alternatively during the SEWE. Preventive measures, hardening, are made in advance to reduce the impact of sequential attacks. The entire process is formulated as a multi-period RO model. Furthermore, it is proved that the most effective resilience enhancement strategies for this model are the same as those for a two-stage RO model, which can be solved by the nested column-and-constraint generation (C&CG) algorithm. In addition, the property of SEWEs, sequentially endangering limited regions of the IEGS, is incorporated to build a data-based uncertainty set and reduce its conservativeness. Simulation results on two IEGSs validate the effectiveness of the proposed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cryogenic propellant management system requirements for Space Station Freedom

Specific propellant management system requirements have been identified for each facility category of SSF. Distributed systems have been analyzed to indentify momentum management, guidance, and traffic management requirements associated with the guidance, navigation, and control system; space-to-space communications and enhanced tracking requirements associated with the communications and tracking system; and propellant management system utility requirements associated with the electrical power system. Flight element analyses determined attach structure, utility distribution, and structural integrity requirements for the pre-integrated truss and high mass manipulation and translation requirements for the mobile base system.

Saucillo, R. J.↗

FERC Order No. 2222 and Considerations for Distributed Wind

The Federal Energy Regulatory Commission (FERC) issued Order No. 2222 in October 2020. The rule directs Regional Transmission Organizations and Independent System Operators (ISOs) to amend their tariffs and participation models to accommodate heterogeneous distributed energy resource (DER) aggregations in the wholesale energy markets that they operate, including capacity, energy, and ancillary service markets. The Commission issued the rule to better capture the benefits provided by DERs deployed in the United States, whose use has been expanding rapidly. The Commission defines DERs as “any resource located on the distribution system, any subsystem thereof or behind a customer meter,” including but not limited to “electric storage resources, distributed generation, demand response, energy efficiency, thermal storage, and electric vehicles and their supply equipment.” The rule aims to increase DER participation in wholesale markets by allowing the creation of DER aggregations, in which multiple DERs that are too small to meet minimum capacity requirements for wholesale markets individually would be able to participate in markets as a single unit. As of June 20, 2023, all ISOs have filed initial compliance plans and a number have begun implementation. Compliance dates range from 2024 to 2029, with Midcontinent ISO having the latest date of compliance proposed for 2029. Southwest Power Pool still has an outstanding date, having no final order yet from FERC, but a target date of the third quarter of calendar year 2025. The rule, which is technology agnostic and requires ISOs to create participation plans that accommodate different DERs, provides an opportunity for distributed wind market expansion. In addition, distributed wind can bring benefits to heterogenous DER aggregations. These benefits include resource diversity (i.e., a complementary generation profile to other types of distributed generation), its small footprint and ability to be co-located with load, and its potential to provide frequency response, voltage support, and black start services, among other ancillary services. This report provides a status update on FERC Order No. 2222, the current state of ISO compliance, and information relevant to the distributed wind industry as DER aggregators and other stakeholders expand their participation to wholesale energy markets.

17 WIND ENERGY↗

Benefit-cost methodology study with example application of the use of wind generators

An example application for cost-benefit methodology is presented for the use of wind generators. The approach adopted for the example application consisted of the following activities: (1) surveying of the available wind data and wind power system information, (2) developing models which quantitatively described wind distributions, wind power systems, and cost-benefit differences between conventional systems and wind power systems, and (3) applying the cost-benefit methodology to compare a conventional electrical energy generation system with systems which included wind power generators. Wind speed distribution data were obtained from sites throughout the contiguous United States and were used to compute plant factor contours shown on an annual and seasonal basis. Plant factor values (ratio of average output power to rated power) are found to be as high as 0.6 (on an annual average basis) in portions of the central U. S. and in sections of the New England coastal area. Two types of wind power systems were selected for the application of the cost-benefit methodology. A cost-benefit model was designed and implemented on a computer to establish a practical tool for studying the relative costs and benefits of wind power systems under a variety of conditions and to efficiently and effectively perform associated sensitivity analyses.

Zimmer, R. P.↗