Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Electrically‐Driven Metal‐Insulator Transitions Emerging from Localizing Current Density and Temperature

Negative differential resistance (NDR) is a key electronic response enabling two‐terminal artificial neurons that can be achieved through different physical phenomena, including phase‐homogeneous current density and temperature (electro‐thermal) localizations and spatially‐localized metal‐insulator phase transitions (MITs). These two effects have been observed to occur sequentially in select electrically‐biased transition metal oxides. However, it is unknown why and under what conditions localizing behaviors precede MITs, particularly as a function of device length scale. To this end, the interplay between phase‐homogeneous electro‐thermal localizations and MITs is investigated in a 3D multiphysics simulation of a lateral thin film device, using the material properties of the prototype MIT material VO 2 . These findings demonstrate that the MIT is nucleated through dynamically localizing current density and temperature. A critical device width (≈0.7 µm in this study) is identified, below which both the electrically‐induced electro‐thermal and phase inhomogeneities cease to appear. It is demonstrated that the formation of spatial inhomogeneities directly relates to device dimensions, and demonstrate the decoupling of NDR from the MIT through device scaling relationships. These results provide insight into the material phenomena underlying the material's electrical responses, clarifying conditions under which spatial inhomogeneities form in electrically‐biased MIT materials.

artificial neuron↗

All-Electric Nonassociative Learning in Nickel Oxide

Habituation and sensitization represent nonassociative learning mechanisms in both non-neural and neural organisms. They are essential for a range of functions from survival to adaptation in dynamic environments. Design of hardware for neuroinspired computing strives to emulate such features driven by electric bias and can also be incorporated into neural network algorithms. Herein, cellular-like learning in oxygen-deficient NiO x devices is demonstrated. Both habituation learning and sensitization response can be achieved in a single device by simply controlling the magnitude of the electric field. Spontaneous memory relaxations and dynamic redistribution of oxygen vacancies under electric bias enable such learning behavior of NiO x under sequential training. These characteristics in simple device arrays are implemented to learn alphabets as well as demonstrate simulated algorithmic use cases in digit recognition. Transition metal oxides with carefully prepared defect concentrations can be highly sensitive to electronic structure perturbations under moderate electrical stimulus and serve as building blocks for next-generation neuroinspired computing hardware.

36 MATERIALS SCIENCE↗

Evaluation of the rheological and electrical percolation of high‐density polyethylene/carbon black composites using mathematical models

Abstract In this work, conductive polymer composites (CPCs) of bio‐based polyethylene (BioPe) containing different concentrations of carbon black (CB) were developed. By using oscillatory rheology analysis, a Newtonian plateau was observed in BioPe, and all BioPe/CB composites had a behavior of a pseudo‐solid and that composites with volume fractions ranging from 0.24 to 0.56 presented higher viscosity, storage, and loss modulus. This suggests the formation of a percolated network and by using the power‐law models, it was observed that the electrical percolation threshold was higher than the rheological percolation threshold. The electrical conductivity was measured using the four‐point probe method and a sigmoid model was used to predict the CPCs' electrical conductivity percolation threshold. The results indicated that the four‐point probe method presented satisfactory results according to the calculated standard deviations and voltage–current characteristics for each round of measurements considering the same ranging as used in rheology analysis. The analytical model used showed a coefficient of determination ( R 2 ) higher than 95%, allowing the prediction of the electrical conductivity of the CPC and the percolation threshold as a function of the volumetric fraction of the CB.

da SiIva, Moacy P.↗

Spurious poles in the scattering of electric and magnetic charges

Theories with both electric and magnetic charges (“mutually non-local” theories) have several major obstacles to calculating scattering amplitudes. Even when the interaction arises through the kinetic mixing of two, otherwise independent, U(1)’s, so that all low-energy interactions are perturbative, difficulties remain: using a self-dual, local formalism leads to spurious poles at any finite order in perturbation theory. Correct calculations must show how the spurious poles cancel in observable scattering amplitudes. Consistency requires that one type of charge is confined as a result of one of the U(1)’s being broken. Here we show how the constraints of confinement and parity conservation on observable processes manages to cancel the spurious poles in scattering and pair production amplitudes, paving the way for systematic studies of the experimental signatures of “dark” electric-magnetic processes. Along the way we demonstrate some novel effects in electric-magnetic interactions, including that the amplitude for single photon production of magnetic particles by electric particles vanishes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tunable phase structure in NaNbO 3 ceramics by grain-size effect, electric field and heat treatment

Large polarization and strain change during antiferroelectric - ferroelectric phase transition under electric field is the foundation for realizing excellent electrical properties in antiferroelectric ceramics, therefore, the adjustment of antiferroelectricity and clarification of the corresponding mechanism is the foundation for controlling electrical properties. NaNbO3 is the most complex perovskite system showing multiple antiferroelectric phases in a wide temperature range, in which the antiferroelectricity shows obvious instability with changing external and internal conditions, namely the antiferroelectric phase can be adjusted by grain-size effect, electric field and heat treatment. According to the systematical study in terms of the Rietveld refinement of synchrotron XRD and Raman, NaNbO3 exhibits a ferrielectric P21ma structure at room temperature, the ferroelectric component of which increases with decreasing grain size. Two antiferroelectric tetragonal phases exist around Curie temperature TC before the entrance of antiferroelectric R phase zone, while an antiferroelectric monoclinic phase, which can be maintained to room temperature by annealing treatment, acts as the bridge for the depolarization of the poled NaNbO3 with ferroelectric Q phase. A detailed phase diagram mainly focused on the antiferroelectric phase zones of NaNbO3 is plotted, which gives a clear understanding about the polymorphic phase transitions under different conditions. Finally, the results concluded in this work would give a clear guidance for designing high-performance NaNbO3-based lead-free ceramics from the point of structure.

36 MATERIALS SCIENCE↗

Electrical and structural characterization of nano-carbon–aluminum composites fabricated by electro-charging-assisted process

Incorporating nano-carbon phases into metal-matrix composites is a promising strategy for simultaneously enhancing electrical conductivity and mechanical properties of metals. Here, we describe the manufacture of novel nano-carbonaluminum composites by an electro-charge-assisted process (EAP) that show 5.6% ± 1.7% increase in electrical conductivity compared to the base metal alloy. The source of nano-carbon that we used in this study is activated carbon with particle size less than 100 nm. The enhancement is attributed to nano-graphitic structures that extend through the lattice of the metal. Through electron transfer from the metal to the nanostructures the electron density at the interface of nano-crystalline graphite and the metal lattice increases thereby enhancing the bulk electrical conductivity. We identify the important fabrication parameters of the EAP for a reaction system employing a tapered graphite cathode. Here, a high current density of 100 A/cm 2 causes ionization and crystallization of the carbon in the liquid metal. The increase in electrical conductivity of the composite are directly related to the incorporation of the nanocrystalline carbon in the metal lattice. The superior performance of these nano-carbon aluminum composites makes them promising candidates for power transmission lines and other applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stress due to electric charge density distribution in a dielectric slab

The spatial distribution of electric field due to an imposed electric charge density profile in an infinite slab of dielectric material is derived analytically by integrating Gauss’s law. Various charge density distributions are considered, including exponential and power-law forms. Here, the Maxwell stress tensor is used to compute a notional static stress in the material due to the charge density and its electric field. Characteristics of the electric field and stress distributions are computed for example cases in polyethylene, showing that field magnitudes exceeding the dielectric strength would be required in order to achieve a stress exceeding the ultimate tensile strength.

42 ENGINEERING↗

Technoeconomic Analysis of Steel Production with Electric Thermal Energy Storage

The iron and steel industry is an important manufacturing sector and one of the largest energy consumers in the United States and globally. Hydrogen direct reduction of iron ore (H2DRI) is considered a promising process that could enhance domestic steel production. This process requires hydrogen inlet temperatures up to 950 degrees C to drive the endothermic reduction of the iron ore pellets. In this work we investigate the technoeconomic performance of an H2DRI plant using electric thermal energy storage (ETES) technologies for the hydrogen heating, compared to conventional natural gas fired heaters, hydrogen fired heaters, and electric hydrogen heaters. A technoeconomic analysis framework for the plant is developed and used in multiple case studies, covering different hydrogen prices, grid electricity profiles, and financing scenarios. The levelized cost of steel production is found out to be in the range of $775-950/mt, which is mostly inside the benchmarked steel price of $941/mt. ETES-based hydrogen heating is found to be in par with conventional natural gas fired heaters, and cheaper than hydrogen fired heaters and electric hydrogen heaters. The major cost drivers are the iron ore and hydrogen feedstock, followed by the hydrogen compression and heating capital. Several insights and suggested future directions are identified.

08 HYDROGEN↗

Economic dispatch for electricity merchant with energy storage and wind plant: State of charge based decision making considering market impact and uncertainties

Here this paper investigates how the market impact of electricity merchants and uncertainty of wind generation affect their co-optimized scheduling policy, specifically for merchants who have both energy storage and wind plants. In the existing literature, merchants' trading actions are usually assumed not to affect market prices; however, a large-scale energy storage merchant's actions can affect market prices. To this end, we approximate the electricity price by a linear function of the quantity of power traded by the merchant in the reward function to achieve decision-making incorporating the market impact. This paper utilizes the dynamic programming approach to analyze merchants' optimal multi-period decision-making incorporating market impact, uncertain wind generation, and energy storage constraints. First, our results demonstrate that for a merchant with co-located energy storage facilities and wind power plants, the energy storage's feasible state of charge (SOC) range can be segmented into four possible sub-ranges by three analytically developed SOC reference points. The unique optimal trading decision can be achieved by comparing the current energy inventory and the SOC references of the next period. Second, our results show that market impact and uncertainties substantially change the optimal storage scheduling policy by impacting the values of the reference points. To mitigate the negative effect of the merchant's market impact on buying and selling actions, the merchant may reduce the amount of generating or pumping electricity each period to maximize profit. Moreover, we identify and investigate the trade-off between market price and transaction quantity. Our findings provide co-optimized scheduling guidance for electricity merchants with co-located energy storage and renewable power plants systems.

17 WIND ENERGY↗

Extremum-Seeking-Based Ultra-local Model Predictive Control and Its Application to Electric Motor Speed Regulation

Electric vehicle (EV) market is rapidly expanding. As a critical component of EV, an electric motor needs to accurately follow a reference speed signal while respecting the electrical current constraint for safety. Those requirements are usually formulated as a model predictive control (MPC) problem. However, the performance of traditional model-based MPC depends on the accuracy of the system model, which may not always be guaranteed in reality. Therefore, we utilize a data-driven, model-free predictive control strategy, called ultra-local MPC (ULMPC), to control the speed of an electric motor. To further enhance the control performance of ULMPC, we employ the extremum-seeking control (ESC) to tune the control gain of the ULMPC online. Simulation and hardware experiments demonstrate the enhancement of the extremum-seeking-based ULMPC over a constant-gain ULMPC.

Zhou, Yujing↗

Grid-responsive hydrogen production: Capital utilization and current density vs. efficiency in variable electricity markets

To achieve low-cost hydrogen production from water electrolyzers, grid tied electrolysis may need to operate dynamically to minimize the cost of supplying energy to the electrolyzer stack and produce hydrogen during low-cost hours and turn off/down during high-cost hours. Operating systems in this way can decrease capital utilization (capacity factor) and electricity costs. This strategy would shift the dominant cost drivers away from electricity (and thus efficiency) to the capital costs of the system, due to the underutilized capital when operating at low-capacity factors. Increasing the operational current density of the system could, in effect, reduce the capital cost of the system while producing hydrogen at a lower efficiency on a per unit energy basis. In the variable electricity cost profiles analyzed in this paper, increasing the current density for liquid alkaline from 0.5 A/cm2 to 1.5 Ac/m2 and proton exchange membrane electrolyzers from 2 A/cm2 to 4 A/cm2 resulted in substantial reductions in the levelized cost of hydrogen. Additionally, as capacity factors and electricity costs decrease, the optimal operating current density of the electrolyzer systems analyzed increases. These findings suggest R&D efforts should focus on increasing the operational current densities, reducing the turn down ratios, and understanding the durability implications of those strategies on low-temperature liquid alkaline and proton exchange membrane electrolyzers.

08 HYDROGEN↗

Effects of Deep Reductions in Energy Storage Costs on Highly Reliable Wind and Solar Electricity Systems.

We use 36 years (1980-2015) of hourly weather data over the contiguous United States (CONUS) to assess the impact of low-cost energy storage on highly reliable electricity systems that use only variable renewable energy (VRE; wind and solar photovoltaics). Even assuming perfect transmission of wind and solar generation aggregated over CONUS, energy storage costs would need to decrease several hundred-fold from current costs (to ~$1/kWh) in fully VRE electricity systems to yield highly reliable electricity without extensive curtailment of VRE generation. The role of energy storage changes from high-cost storage competing with curtailment to fill short-term gaps between VRE generation and hourly demand to near-free storage serving as seasonal storage for VRE resources. Energy storage faces "double penalties" in VRE/storage systems: with increasing capacity, (1) the additional storage is used less frequently and (2) hourly electricity costs would become less volatile, thus reducing price arbitrage opportunities for the additional storage.

14 SOLAR ENERGY↗

Achieving an 80% carbon-free electricity system in China by 2035

Dramatic reductions in solar, wind, and battery storage costs create new opportunities to reduce emissions and costs in China’s electricity sector, beyond current policy goals. This study examines the cost, reliability, emissions, public health, and employment implications of increasing the share of non-fossil fuel (“carbon free”) electricity generation in China to 80% by 2035. The analysis uses state-of-the-art modeling with high resolution load, wind, and solar inputs. The study finds that achieving an 80% carbon free electricity system in China by 2035 could reduce wholesale electricity costs, relative to a current policy baseline, while maintaining high levels of reliability, reducing deaths from air pollution, and increasing employment. In our 80% scenario, wind and solar generation capacity reach 3 TW and battery storage capacity reaches 0.4 TW by 2035, implying a rapid scale up in these resources that will require changes in policy targets, markets and regulation, and land use policies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

US building energy efficiency and flexibility as an electric grid resource

Buildings consume 75% of U.S. electricity; therefore, improving the efficiency and flexibility of building operations could increase the reliability and resilience of the rapidly-changing electricity system. We estimate the technical potential near- and long-term impacts of best available building efficiency and flexibility measures on annual electricity use and hourly demand across the contiguous U.S. Co-deployment of building efficiency and flexibility avoids up to 742 TWh of annual electricity use and 181 GW of daily net peak load in 2030, rising to 800 TWh and 208 GW by 2050; at least 59 GW and 69 GW of the peak reductions are dispatchable. Implementing efficiency measures alongside flexibility measures reduces the potential for off-peak load increases, underscoring limitations on load shifting in efficient buildings. Overall, however, we find a substantial building-grid resource that could reduce future fossil-fired generation needs while also reducing dependence on energy storage with increasing variable renewable energy penetration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Measurement of optically-pumped electron spin polarization in n-GaAs at high external electric fields

We use the technique of time-resolved Kerr rotation (TRKR) to measure the electron spin polarization generated by optical spin pumping in an n-type gallium arsenide (GaAs) epilayer when an external electric field is simultaneously applied on the sample. The drift of the electron spins under the influence of the external electric field is captured with spatial scans of the pump–probe separation. A significant decay in the magnitude of electron spin polarization with electric field is observed and is attributed to the increased inhomogeneous broadening caused by the field-induced drift and the hot electron effects. Here, we extend the electric field range to as high as the Gunn threshold field in the measurement and we do not observe a spin amplification effect due to the spin Gunn effect under our experimental scheme.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical passivation of III-V multijunction solar cells with luminescent coupling effect

Perimeter recombination is one of the causes identified for having a nonuniform luminescent coupling effect in III-V multijunction solar cells. A potential solution could be the electrical passivation of the multijunction solar cell perimeter. To test this hypothesis, electrical passivation of InGaP/GaAs/Ge 3-junction solar cells was done by the atomic layer deposition of thin Al2O3 films. Further, perimeter passivation of a 3-junction solar cell relatively increased current collection measured at luminescent coupling and direct subcell excitation by as much as 11.4% and 29.8%, respectively. Meanwhile, the current homogeneity improved relatively by as much as 7.9% after electrical passivation. At 1-sun global standard illumination (AM 1.5G), 0.2% absolute conversion efficiency increase was achieved. Therefore, electrical passivation of fully working III-V multijunction solar cells is a non-invasive, post-treatment process that can recover losses due to surface defects caused by oxidation.

14 SOLAR ENERGY↗

Life Cycle Emissions and Health Cost Impacts of Producing Ethanol and Electricity from Willow and Switchgrass in the Riparian Buffers of Mid-Atlantic United States

The United States (US Mid-Atlantic Region (MAR) has the potential to grow a variety of perennial feedstocks such as switchgrass and shrub willow to increase domestic energy production. These cellulosic feedstocks have also shown improved ecosystem services, such as soil carbon sequestration, nitrate leaching reduction, and flood mitigation along rivers and streams as partially harvested riparian buffers. To examine the effects on greenhouse gases (GHGs) and criteria air pollutants (CAPs) from using these feedstocks to produce ethanol or electricity, we conducted a comprehensive life cycle assessment (LCA) and estimated the impact on human health costs when land use is changed from corn production for ethanol. Results indicate up to 54% reduced GHG per hectare from using willow and switchgrass feedstock sources to produce ethanol instead of corn. However, there was a trade-off in terms of CAP emission, as grass-based energy emitted more NO x and SO x compared to the corn ethanol pathway, except for SO X emissions from willow-based electricity. Electricity from cellulosic biomass had higher particulate matter (PM) emission compared to that from corn ethanol. Estimates for health cost to society ranged from $2498 ha –1 for electricity from switchgrass to a net benefit of $448 ha –1 for ethanol production from willow, depending on varying biomass yield under different market scenarios. Although using cellulosic feedstocks to produce bioenergy has great potential to reduce GHG emissions, CAP control measures are needed to manage CAP-induced health costs.

Bioenergy↗