A memory-distributed quasi-Newton solver for nonlinear programming problems with a small number of general constraints

We approach the problem of parallelizing state-of-the-art nonlinear programming optimization algorithms.Specifically, we focus on parallelizing quasi-Newton interior-point methods that use limited-memory secant Hessian approximations. Such interior-point methods are known to have better convergence properties and to be more effective on large-scale problems than gradient-based and derivative-free optimization algorithms. We target nonlinear and potentially nonconvex optimization problems with an arbitrary number of bound constraints and a small number of general equality and inequality constraints on the optimization variables. These problems occur for example in the form of optimal control, optimal design, and inverse problems governed by ordinary or partial differential equations, whenever they are expressed in a “reduced-space” optimization approach. We introduce and analyze the time and space complexity of a decomposition method for solving the quasi-Newton linear systems that leverages the fact that the quasi-Newton Hessian matrix has a small number of dense blocks that border a low-rank update of a diagonal matrix. This enables an efficient parallelization on memory-distributed computers of the iterations of the optimization algorithm, a state-of-the-art filter line-search interior-point algorithm by Wächter et. al. We illustrate the efficiency of the proposed method by solving structural topology optimization problems on up to 4608 cores on a parallel machine.

97 MATHEMATICS AND COMPUTING↗

Current developments in laser ablation-inductively coupled plasma-mass spectrometry for use in geology, forensics, and nuclear nonproliferation research

This dissertation focused on new applications of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The diverse fields that were investigated show the versatility of the technique. In Chapter 2, LA-ICP-MS was used to investigate the rare earth element (REE) profiles of garnets from the Broken Hill Deposit in New South Wales, Australia. The normalized REE profiles helped to shed new light on the formation of deposits of sulfide ores. This information may be helpful in identifying the location of sulfide ore deposits in other locations. New sources of metals such as Pg, Zn, and Ag, produced from these ores, are needed to sustain our current technological society. The application of LA-ICP-MS presented in Chapter 3 is the forensics analysis of automotive putty and caulking. The elemental analysis of these materials was combined with the use of Principal Components Analysis (PCA). The PCA comparison was able to differentiate the automotive putty samples by manufacturer and lot number. The analysis of caulk was able to show a differentiation based on manufacturer, but no clear differentiation was shown by lot number. This differentiation may allow matching of evidence in the future. This will require many more analyses and the construction of a database made up of many different samples. The 4th chapter was a study of the capabilities of LA-ICP-MS for fast and precise analysis of particle ensembles for nuclear nonproliferation applications. Laser ablation has the ability to spatially resolve particle ensembles which may contain uranium or other actinides from other particles present in a sample. This is of importance in samples obtained from air on filter media. The particle ensembles of interest may be mixed in amongst dust and other particulates. A problem arises when ablating these particle ensembles directly from the filter media. Dust particles other than ones of interest may be accidentally entrained in the aerosol of the ablated particle ensemble. This would cause the analysis to be skewed. The use of a gelatin substrate allows the ablation a particle ensemble without disturbing other particles or the gelatin surface. A method to trap and ablate particles on filter paper using collodion was also investigated. The laser was used to dig through the collodion layer and into the particle ensemble. Both of these methods fix particles to allow spatial resolution of the particle ensembles. The use of vanillic acid as a possible enhancement to ablation was also studied. A vanillic acid coating of the particles fixed on top of the gelatin substrate was not found to have any positive effect on either signal intensity or precision. The mixing of vanillic acid in the collodion solution used to coat the filter paper increased ablation signal intensity by a factor of 4 to 5. There was little effect on precision, though. The collodion on filter paper method and the gelatin method of resolving particles have shown themselves to be possible tools in fighting proliferation of nuclear weapons and material. Future applications of LA-ICP-MS are only limited by the imagination of the investigator. Any material that can be ablated and aerosolized is a potential material for analysis by LA-ICP-MS. Improvements in aerosol transport, ablation chamber design, and laser focusing can make possible the ablation and analysis of very small amounts of material. This may perhaps lead to more possible uses in forensics. A similar method to the one used in Chapter 3 could perhaps be used to match drug residue to the place of origin. Perhaps a link could be made based on the elements leached from the soil by plants used to make drugs. This may have a specific pattern based on where the plant was grown. Synthetic drugs are produced in clandestine laboratories that are often times very dirty. The dust, debris, and unique materials in the lab environment could create enough variance to perhaps match drugs produced there to samples obtained off the street. Even if the match was not strong enough to be evidence, the knowledge that many samples of a drug are being produced from a similar location could help law enforcement find and shut down the lab. Future nuclear nonproliferation research would also be helped by the ability to get more analyte signal from smaller and smaller amounts of material. One possible future line of research would be to find a way to make the collodion layer as thin as possible so less laser shots are needed to get to the particle of interest. Collodion and gelatin analysis could also be used for environmental applications where spatial resolution of particles is needed. Individual particles could give information about the contaminants present in a given location. The wide versatility of LA-ICP-MS makes it a useful tool for nearly nondestructive analysis of a variety of samples and matrices.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Helicopter terminal approach using differential GPS with vertical-axis enhancement

The NAVSTAR Global Positioning System (GPS) in differential mode (DGPS) has been shown to be least accurate in the vertical axis. The vertical axis also has the most stringent accuracy requirements for aircraft precision approach and landing. A series of flight tests were conducted to evaluate a concept for improving the DGPS vertical axis navigation performance. These tests incorporated augmentation sensors to aid the DGPS navigation solution during terminal approach operations. A GPS receiver was installed on board a NASA helicopter and interfaced with a real-time digital computer system. A reconfigurable navigation filter programmed in the digital computer provided an augmented DGPS solution, with selectable inputs from a low-cost vertical accelerometer, a barometric altimeter, and the aircraft attitude gyros. The reference aircraft position was determined by a laser tracker. Extensive post-test analysis was done to optimize the filter performance during the terminal approach operation. Test results show that baro-altimeter aiding can significantly improve vertical axis performance. Follow-on tests are planned for the optimized configurations.

Edwards, F. G.↗

Investigation of nonlinear motion simulator washout schemes

An overview is presented of some of the promising washout schemes which have been devised. The four schemes presented fall into two basic configurations; crossfeed and crossproduct. Various nonlinear modifications further differentiate the four schemes. One nonlinear scheme is discussed in detail. This washout scheme takes advantage of subliminal motions to speed up simulator cab centering. It exploits so-called perceptual indifference thresholds to center the simulator cab at a faster rate whenever the input to the simulator is below the perceptual indifference level. The effect is to reduce the angular and translational simulation motion by comparison with that for the linear washout case. Finally, the conclusions and implications for further research in the area of nonlinear washout filters are presented.

Riedel, S. A.↗

NASA Tech Briefs, September 2009

opics covered include: Filtering Water by Use of Ultrasonically Vibrated Nanotubes; Computer Code for Nanostructure Simulation; Functionalizing CNTs for Making Epoxy/CNT Composites; Improvements in Production of Single-Walled Carbon Nanotubes; Progress Toward Sequestering Carbon Nanotubes in PmPV; Two-Stage Variable Sample-Rate Conversion System; Estimating Transmitted-Signal Phase Variations for Uplink Array Antennas; Board Saver for Use with Developmental FPGAs; Circuit for Driving Piezoelectric Transducers; Digital Synchronizer without Metastability; Compact, Low-Overhead, MIL-STD-1553B Controller; Parallel-Processing CMOS Circuitry for M-QAM and 8PSK TCM; Differential InP HEMT MMIC Amplifiers Embedded in Waveguides; Improved Aerogel Vacuum Thermal Insulation; Fluoroester Co-Solvents for Low-Temperature Li+ Cells; Using Volcanic Ash to Remove Dissolved Uranium and Lead; High-Efficiency Artificial Photosynthesis Using a Novel Alkaline Membrane Cell; Silicon Wafer-Scale Substrate for Microshutters and Detector Arrays; Micro-Horn Arrays for Ultrasonic Impedance Matching; Improved Controller for a Three-Axis Piezoelectric Stage; Nano-Pervaporation Membrane with Heat Exchanger Generates Medical-Grade Water; Micro-Organ Devices; Nonlinear Thermal Compensators for WGM Resonators; Dynamic Self-Locking of an OEO Containing a VCSEL; Internal Water Vapor Photoacoustic Calibration; Mid-Infrared Reflectance Imaging of Thermal-Barrier Coatings; Improving the Visible and Infrared Contrast Ratio of Microshutter Arrays; Improved Scanners for Microscopic Hyperspectral Imaging; Rate-Compatible LDPC Codes with Linear Minimum Distance; PrimeSupplier Cross-Program Impact Analysis and Supplier Stability Indicator Simulation Model; Integrated Planning for Telepresence With Time Delays; Minimizing Input-to-Output Latency in Virtual Environment; Battery Cell Voltage Sensing and Balancing Using Addressable Transformers; Gaussian and Lognormal Models of Hurricane Gust Factors; Simulation of Attitude and Trajectory Dynamics and Control of Multiple Spacecraft; Integrated Modeling of Spacecraft Touch-and-Go Sampling; Spacecraft Station-Keeping Trajectory and Mission Design Tools; Efficient Model-Based Diagnosis Engine; and DSN Simulator.

Source record↗

Differentiating multi-MeV, multi-ion spectra with CR-39 solid-state nuclear track detectors

The development of high intensity petawatt lasers has created new possibilities for ion acceleration and nuclear fusion using solid targets. In such laser-matter interaction, multiple ion species are accelerated with broad spectra up to hundreds of MeV. To measure ion yields and for species identification, CR-39 solid-state nuclear track detectors are frequently used. However, these detectors are limited in their applicability for multi-ion spectra differentiation as standard image recognition algorithms can lead to a misinterpretation of data, there is no unique relation between track diameter and particle energy, and there are overlapping pit diameter relationships for multiple particle species. In this report, we address these issues by first developing an algorithm to overcome user bias during image processing. Second, we use calibration of the detector response for protons, carbon and helium ions (alpha particles) from 0.1 to above 10 MeV and measurements of statistical energy loss fluctuations in a forward-fitting procedure utilizing multiple, differently filtered CR-39, altogether enabling high-sensitivity, multi-species particle spectroscopy. To validate this capability, we show that inferred CR-39 spectra match Thomson parabola ion spectrometer data from the same experiment. Filtered CR-39 spectrometers were used to detect, within a background of ~ 2 × 10 11 sr -1 J -1 protons and carbons, (1.3 ± 0.7) × 10 8 sr -1 J -1 alpha particles from laser-driven proton-boron fusion reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image quality comparison between single energy and dual energy CT protocols for hepatic imaging

Purpose: Multi-detector computed tomography (MDCT) enables volumetric scans in a single breath hold and is clinically useful for hepatic imaging. For simple tasks, conventional single energy (SE) computed tomography (CT) images acquired at the optimal tube potential are known to have better quality than dual energy (DE) blended images. However, liver imaging is complex and often requires imaging of both structures containing iodinated contrast media, where atomic number differences are the primary contrast mechanism, and other structures, where density differences are the primary contrast mechanism. Hence it is conceivable that the broad spectrum used in a dual energy acquisition may be an advantage. In this work we are interested in comparing these two imaging strategies at equal-dose and more complex settings. Methods: We developed numerical anthropomorphic phantoms to mimic realistic clinical CT scans for medium size and large size patients. MDCT images based on the defined phantoms were simulated using various SE and DE protocols at pre- and post-contrast stages. For SE CT, images from 60 kVp through 140 with 10 kVp steps were considered; for DE CT, both 80/140 and 100/140 kVp scans were simulated and linearly blended at the optimal weights. To make a fair comparison, the mAs of each scan was adjusted to match the reference radiation dose (120 kVp, 200 mAs for medium size patients and 140 kVp, 400 mAs for large size patients). Contrast-to-noise ratio (CNR) of liver against other soft tissues was used to evaluate and compare the SE and DE protocols, and multiple pre- and post-contrasted liver-tissue pairs were used to define a composite CNR. To help validate the simulation results, we conducted a small clinical study. Eighty-five 120 kVp images and 81 blended 80/140 kVp images were collected and compared through both quantitative image quality analysis and an observer study. Results: In the simulation study, we found that the CNR of pre-contrast SE image mostly increased with increasing kVp while for post-contrast imaging 90 kVp or lower yielded higher CNR images, depending on the differential iodine concentration of each tissue. Similar trends were seen in DE blended CNR and those from SE protocols. In the presence of differential iodine concentration (i.e., post-contrast), the CNR curves maximize at lower kVps (80–120), with the peak shifted rightward for larger patients. The combined pre- and post-contrast composite CNR study demonstrated that an optimal SE protocol has better performance than blended DE images, and the optimal tube potential for SE scan is around 90 kVp for a medium size patients and between 90 and 120 kVp for large size patients (although low kVp imaging requires high x-ray tube power to avoid photon starvation). Also, a tin filter added to the high kVp beam is not only beneficial for material decomposition but it improves the CNR of the DE blended images as well. The dose adjusted CNR of the clinical images also showed the same trend and radiologists favored the SE scans over blended DE images. Conclusions: Our simulation showed that an optimized SE protocol produces up to 5% higher CNR for a range of clinical tasks. The clinical study also suggested 120 kVp SE scans have better image quality than blended DE images. Hence, blended DE images do not have a fundamental CNR advantage over optimized SE images.

60 APPLIED LIFE SCIENCES↗

An Instrument to Enable Identification of Anthropogenic CO2 Emissions Using Concurrent CO Measurements

We have developed an instrument concept that will enable the measurement of CO from the top of the atmosphere to the Earth's surface with very high sensitivity and at the high spatial and temporal resolutions required by the NRC Decadal Survey mission Active Sensing of Carbon Dioxide (CO2) over Nights, Days and Seasons (ASCENDS). We are developing an innovative CO sensor that will enable the ASCENDS mission to differentiate between anthropogenic and natural sources and sinks of global carbon. The NRC Decadal Survey places particular emphasis on retrieving CO information for the planetary boundary layer. Measurement made using both the 2.3 micron and 4.7 micron channels are needed to achieve the sensitivity required in the lower atmosphere where the degree of CO - CO2 correlation is indicative of anthropogenic sources of CO2. Measurements made using only the 4.7 micron channel cannot provide sufficient sensitivity to CO in the very lowest layers of the atmosphere. The fundamental method we use is Gas Filter Correlation Radiometry (GFCR), a highly successful technique used in other airborne and space-based missions for detecting trace species in the Earth's atmosphere. Our version of GFCR overcomes many of the limitations encountered by prior and existing instruments, allowing us to measure weak signals from small targets very quickly and with extremely high specificity by employing a new dual beam radiometer concept using a focal plane array. Our design will provide a means to make the desired CO measurements for the ASCENDS mission. A simple change in gas filter cell contents would allow the same hardware to measure CH4 with high precision under the nominal ASCENDS mission spatial and temporal constraints. All critical components in the sensor design are mature, many subsystems tested, and the system has been extensively modeled, bringing it to a present Technology Readiness Level (TRL) of 3 (though some individual components are at TRLs 6-9). We are presently developing critical components for the new spectrometer and advancing our understanding of the measurement requirements for both CO and CH4. This new GFCR technique/sensor will enable measurements of trace gases with high sensitivity while maintaining the inherent robustness and simplicity of the more traditional radiometer hardware. Initial estimates of cost/risk of a spacebased 2-channel GFCR indicate that our design is extremely cost effective and will fit within existing ASCENDS mission budget constraints as determined by the NRC Decadal Survey and a NASA-sponsored mission study.

Cook, William B.↗

Improved sensing of vertical velocity for vertical position control using loop voltage signals on EAST

Vertical position control of shaped plasma is critical for all elongated tokamaks to achieve safe and stable plasma discharge. In EAST, the in-vessel coil (IC) is employed for fast control of plasma vertical motion which power supply capabilities limits the controllability of vertical instability. Moreover, adequate signal-to-noise ratio of vertical position measurement can also realize an improvement in vertical control. In EAST, plasma vertical position Z p is produced nearly by all integrated magnetics, fast Z error signal is obtained by filtering from Zp. Then this fast Z error and its derivative term (dz/dt) are controlled by IC with a separate PD controller. Yet, it has a low signal-to-noise ratio which limits the gains that can be used successfully in the PD control loops. To provide less noisy dz/dt signal, the successful use of multiple up/down loop voltage pairs instead of derivative of z derived from magnetic probe signals will be discussed. Experiment show that even a single pair of loop voltage signal has better signal-to-noise ratio than differentiation of Z p . In addition, flux loop pickup signals from the IC current are also measured with series of positive and negative IC current pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimum constrained image restoration filters

The research described centered on development of an optimum image restoration filter (IRF) minimizing the radius of gyration of the corrected or composite system point-spread function (P-SF) subject to contraints, and reducing 2-dimensional spatial smearing or blurring of an image. The constraints are imposed on the radius of gyration of the IRF P-SF, the total restored image noise power, and the shape of the composite system frequency spectrum. The image degradation corresponds to mapping many points from the original image into a single resolution element. The P-SF is obtained as solution to a set of simultaneous differential equations obeying nonlinear integral constraints. Truncation errors due to edge effects are controlled by constraining the radius of gyration of the IRF P-SF. An iterative technique suppresses sidelobes of the composite system P-SF.

Riemer, T. E.↗

Polymer, Additives, and Processing Effects on N95 Filter Performance

The current severe acute respiratory syndrome coronavirus 2 (SARS-COV-2) pandemic has highlighted the need for personal protective equipment, specifically filtering facepiece respirators like N95 masks. While it is common knowledge that polypropylene (PP) is the industry standard material for filtration media, trial and error is often required to identify suitable commercial precursors for filtration media production. This work aims to identify differences between several commercial grades of PP and demonstrate the development of N95 filtration media with the intent that the industry partners can pivot and help address N95 shortages. Three commercial grades of high melt flow index PP were melt blown at Oak Ridge National Laboratory and broadly characterized by several methods including differential scanning calorimetry (DSC), X-ray diffraction (XRD), and neutron scattering. Despite the apparent similarities (high melt flow and isotacticity) between PP feedstocks, the application of corona charging and charge enhancing additives improve each material to widely varying degrees. From the analysis performed here, the most differentiating factor appears to be related to crystallization of the polymer and the resulting electret formation. Materials with higher crystallization onset temperatures, slower crystallization rates, and larger number of crystallites form a stronger electret and are more effective at filtration.

36 MATERIALS SCIENCE↗

Reduced Common-Mode Voltage PWM Scheme for Full-SiC Three-Level Uninterruptible Power Supply With Small DC-Link Capacitors

In this article, a pulsewidth modulation (PWM) scheme for three-level full-SiC uninterruptible power supplies is developed to achieve a high power density. Two key passive components are selected for size reduction of the ac-ac stage: common-mode (CM) EMI filter, and dc-link capacitors. To reduce the CM noise, a new vector combination is proposed based on synchronous switching among three-phases. The proposed combinations align CM voltage (CMV) to be a single pulse per switching period. Owing to the simple shape, CMV cancellation between a three-level rectifier and inverter can be maximally utilized. A transition between the three combinations can control the drift of neutral point voltage. An equivalent carrier-based implementation is developed. Second, a simple algorithm to compensate neutral point voltage fluctuation is proposed both for differential mode (DM) and CM output voltage. Low-order harmonics on three-phase currents and an additional high-frequency CM noise by misaligned switching instant can be eliminated. The proposed compensation can be implemented by a simple correction on carrier slopes and injected zero-sequence voltage. The proposed PWM scheme is verified with 20-kW full-SiC UPS switching at 60 kHz with 140 μF dc-link capacitors.

42 ENGINEERING↗

From Individuals to Epidemics

Heterogeneous mixing fundamentally changes the dynamics of infectious diseases; finding ways to incorporate it into models represents a critical challenge. Phenomenological approaches are deficient in their lack of attention to underlying processes; individual-based models, on the other hand, may obscure the essential interactions in a sea of detail. The challenge then is to find ways to bridge these levels of description, starting from individual-based models and deriving macroscopic descriptions from them that retain essential detail, and filter out the rest. In this paper, attempts to achieve this transformation are described for a class of models where non-random mixing arises from the spatial localization of interactions. In general, the epidemic threshold is found to be larger owing to spatial localization than for a homogeneous mixing population. An improved estimate of the dynamics is developed by the use of moment equations, and a simple estimate of the threshold in terms of a 'dyad heuristic'. For more general models in which local infection is not described by mass action, the connection with related partial differential equations is investigated.

Levin, Simon A.↗

Filtered Mass Density Function for Design Simulation of High Speed Airbreathing Propulsion Systems

The objective of this research is to develop and implement new methodology for large eddy simulation of (LES) of high-speed reacting turbulent flows. We have just completed two (2) years of Phase I of this research. This annual report provides a brief and up-to-date summary of our activities during the period: September 1, 2000 through August 31, 2001. In the work within the past year, a methodology termed "velocity-scalar filtered density function" (VSFDF) is developed and implemented for large eddy simulation (LES) of turbulent flows. In this methodology the effects of the unresolved subgrid scales (SGS) are taken into account by considering the joint probability density function (PDF) of all of the components of the velocity and scalar vectors. An exact transport equation is derived for the VSFDF in which the effects of the unresolved SGS convection, SGS velocity-scalar source, and SGS scalar-scalar source terms appear in closed form. The remaining unclosed terms in this equation are modeled. A system of stochastic differential equations (SDEs) which yields statistically equivalent results to the modeled VSFDF transport equation is constructed. These SDEs are solved numerically by a Lagrangian Monte Carlo procedure. The consistency of the proposed SDEs and the convergence of the Monte Carlo solution are assessed by comparison with results obtained by an Eulerian LES procedure in which the corresponding transport equations for the first two SGS moments are solved. The unclosed SGS convection, SGS velocity-scalar source, and SGS scalar-scalar source in the Eulerian LES are replaced by corresponding terms from VSFDF equation. The consistency of the results is then analyzed for a case of two dimensional mixing layer.

Drozda, T. G.↗

Niche differentiation among annually recurrent coastal Marine Group II Euryarchaeota

Since the discovery of archaeoplankton in 1992, the euryarchaeotal Marine Group II (MGII) remains uncultured and less understood than other planktonic archaea. We characterized the seasonal dynamics of MGII populations in the southern North Sea on a genomic and microscopic level over the course of four years. We recovered 34 metagenome-assembled genomes (MAGs) of MGIIa and MGIIb that corroborated proteorhodopsin-based photoheterotrophic lifestyles. However, MGIIa and MGIIb MAG genome sizes differed considerably (~1.9 vs. ~1.4 Mbp), as did their transporter, peptidase, flagella and sulfate assimilation gene repertoires. MGIIb populations were characteristic of winter samples, whereas MGIIa accounted for up to 23% of the community at the beginning of summer. Both clades consisted of annually recurring, sequence-discrete populations with low intra-population sequence diversity. Oligotyping of filtered cell-size fractions and microscopy consistently suggested that MGII cells were predominantly free-living. Cells were coccoid and ~0.7 µm in diameter, likely resulting in grazing avoidance. Based on multiple lines of evidence, we propose distinct niche adaptations of MGIIa and MGIIb Euryarchaeota populations that are characteristic of summer and winter conditions in the coastal North Sea.

Environmental Sciences & Ecology↗

Angular-Rate Estimation Using Delayed Quaternion Measurements

This paper presents algorithms for estimating the angular-rate vector of satellites using quaternion measurements. Two approaches are compared one that uses differentiated quaternion measurements to yield coarse rate measurements, which are then fed into two different estimators. In the other approach the raw quaternion measurements themselves are fed directly into the two estimators. The two estimators rely on the ability to decompose the non-linear part of the rotas rotational dynamics equation of a body into a product of an angular-rate dependent matrix and the angular-rate vector itself. This non unique decomposition, enables the treatment of the nonlinear spacecraft (SC) dynamics model as a linear one and, thus, the application of a PseudoLinear Kalman Filter (PSELIKA). It also enables the application of a special Kalman filter which is based on the use of the solution of the State Dependent Algebraic Riccati Equation (SDARE) in order to compute the gain matrix and thus eliminates the need to compute recursively the filter covariance matrix. The replacement of the rotational dynamics by a simple Markov model is also examined. In this paper special consideration is given to the problem of delayed quaternion measurements. Two solutions to this problem are suggested and tested. Real Rossi X-Ray Timing Explorer (RXTE) data is used to test these algorithms, and results are presented.

Azor, R.↗

Reaching the Diffraction Limit - Differential Speckle and Wide-Field Imaging for the WIYN Telescope

Speckle imaging allows telescopes to achieve diffraction limited imaging performance. The technique requires cameras capable of reading out frames at a very fast rate, effectively 'freezing out' atmospheric seeing. The resulting speckles can be correlated and images reconstructed that are at the diffraction limit of the telescope. These new instruments are based on the successful performance and design of the Differential Speckle Survey Instrument (DSSI).The instruments are being built for the Gemini-N and WIYN telescopes and will be made available to the community via the peer review proposal process. We envision their primary use to be validation and characterization of exoplanet targets from the NASA, K2 and TESS missions and RV discovered exoplanets. Such targets will provide excellent follow-up candidates for both the WIYN and Gemini telescopes. We expect similar data quality in speckle imaging mode with the new instruments. Additionally, both cameras will have a wide-field mode and standard SDSS filters. They will be highly versatile instruments and it is that likely many other science programs will request time on the cameras. The limiting magnitude for speckle observations will remain around 13-14th at WIYN and 16-17th at Gemini, while wide-field, normal CCD imaging operation should be able to go to much fainter, providing usual CCD imaging and photometric capabilities. The instruments will also have high utility as scoring cameras for telescope engineering purposes, or other applications where high time resolution is needed. Instrument support will be provided, including a software pipeline that takes raw speckle data to fully reconstructed images.

detector↗

Narrowband Lyman-continuum imaging of galaxies at z ∼ 2.85

We present results from a survey for z ∼ 2.85 Lyman-continuum (LyC) emission in the HS1549+1933 field and place constraints on the amount of ionizing radiation escaping from star-forming galaxies. Using a custom narrowband filter (NB3420) tuned to wavelengths just below the Lyman limit at z ≥ 2.82, we probe the LyC spectral region of 49 Lyman break galaxies (LBGs) and 91 Lyα emitters (LAEs) spectroscopically confirmed at z ≥ 2.82. Four LBGs and seven LAEs are detected in NB3420. Using V-band data probing the rest-frame nonionizing UV, we observe that many NB3420-detected galaxies exhibit spatial offsets between their LyC and nonionizing UV emission and are characterized by extremely blue NB3420–V colors, corresponding to low ratios of nonionizing to ionizing radiation (F {sub UV}/F {sub LyC}) that are in tension with current stellar population synthesis models. We measure average values of (F {sub UV}/F {sub LyC}) for our LBG and LAE samples, correcting for foreground galaxy contamination and H I absorption in the intergalactic medium. We find (F{sub UV}/F{sub LyC}){sub corr}{sup LBG}=82±45 and (F{sub UV}/F{sub LyC}){sub corr}{sup LAE}=7.4±3.6. These flux density ratios correspond, respectively, to relative LyC escape fractions of f{sub esc,} {sub rel}{sup LBG}=5%--8% and f{sub esc,} {sub rel}{sup LAE}=18%--49%, absolute LyC escape fractions of f{sub esc}{sup LBG}=1%--2% and f{sub esc}{sup LAE}=5%--15%, and a comoving LyC emissivity from star-forming galaxies of 8.8-15.0 × 10{sup 24} erg s{sup –1} Hz{sup –1} Mpc{sup –3}. In order to study the differential properties of galaxies with and without LyC detections, we analyze narrowband Lyα imaging and rest-frame near-infrared imaging, finding that while LAEs with LyC detections have lower Lyα equivalent widths on average, there is no substantial difference in the rest-frame near-infrared colors of LBGs or LAEs with and without LyC detections. These preliminary results are consistent with an orientation-dependent model where LyC emission escapes through cleared paths in a patchy interstellar medium.