Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “difference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Assessment of SNPP VIIRS RSB detector-to-detector differences using deep convective clouds and deserts

An accurate on-orbit characterization of the Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the Suomi National Polar-orbiting Partnership satellite is essential to satisfy the requirements from NOAA, NASA, and the general research community for high-quality operational and research products. NASA’s Land Science Investigator-led Processing System (LSIPS) sensor data records (SDRs) are utilized to assess the stability of the calibrated top of atmosphere reflectance over the deep convective clouds (DCCs) and over the Libya-4desert site. The results from DCCs and desert show detector-to-detector (D2D) reflectance differences in the VIIRS reflective solar bands, 10 moderate-resolution bands (M-bands, M1to M5, M7 to M11), and three imagery resolution bands (I-bands, I1-I3). More importantly, the D2D differences exhibit an increase in magnitude over time for bands M1 to M5 and I1to I2, which induces noticeable striping and higher uncertainties in the downstream data products. The largest D2D difference is observed in bands M1 and M2, with magnitudes greater than1.8% in trends among the 16 detectors and standard deviations less than 0.12% over time. TheD2D stability assessment results over DCCs are consistent with those observed over the Libya-4desert site. To improve the quality of the calibrated SDR reflectance data, NASA’s VIIRS characterization support team has improved the calibration algorithm to incorporate corrections based on these DCC measurements to mitigate the striping (detector differences) observed in the current version of the SDR. These improvements are planned to be included in the next mission reprocessing of the LSIPS land products.

SNPP VIIRS↗

MODIS Detector Differences Using Deep Convective Clouds and Desert Targets

An accurate on-orbit characterization of the Moderate Resolution Imaging Spectroradiometer (MODIS) sensors onboard the Terra and Aqua satellites is essential to satisfy the requirements from the scientific community for high-quality operational and research products. In this study, NASA’s C6.1 L1B data are utilized to assess the stability of the calibrated top of atmosphere reflectance retrieved from individual detectors within a spectral band over deep convective clouds (DCCs) and desert sites. The results from these invariant Earth targets show detector-to-detector (D2D) differences in the L1B reflectance products for select MODIS reflective solar bands. For Aqua MODIS, the D2D differences have no significant change over time for the bands studied. However, the D2D differences exhibit an increase in magnitude over time for Terra MODIS bands 1, 3-7, and 26, which can induce noticeable striping and higher uncertainties in the downstream data products. The D2D stability assessment results over DCCs are consistent with those observed over desert sites. In addition, the view-angle dependence of the D2D differences is investigated by separating the frames along scan into five zones. The D2D assessment is performed for each of the five zones, and the results will further benefit any improvements in the calibration of a detector-dependent response versus scan angle that can be considered for future MODIS Level 1B Collections.

MODIS↗

Different controls of tropical cyclone activity in the Eastern Pacific for two types of El Niño

Abstract The El Niño–Southern Oscillation (ENSO) is known to have different modes of expression, characterized by different dynamics and spatial anomalies patterns: the Eastern Pacific (EP) and Central Pacific (CP) El Niño. The main region of influence of the former is located in the Eastern Pacific, while CP events have a stronger signature of ocean/climate anomalies in the Central West Pacific. This leads to distinctive oceanic and atmospheric signatures that likely have different influences on tropical cyclone (TC) activity in the Eastern Pacific, the second most active region in the world. In this study we investigate the respective role of oceanic and atmospheric conditions on TC formation and intensification in the Eastern Pacific associated with these two flavors of ENSO. We find that the oceanic control, through meridional redistribution of subsurface heat, is the main driver of TC activity during the hurricane season following EP events. In contrast, atmospheric conditions tend to be destructive to TC intensification after those events. The altered atmospheric circulation, in particular the reduction of vertical wind shear and the increase in relative humidity, tends to be more influential in controlling TC activity post CP events. However, unlike for subsurface heat, these changes in atmospheric conditions are not statistically distinct between these two ENSO flavors—although they are consistent across all atmospheric data sets tested. Overall, unlike after EP El Niño events, the hurricane season activity following a CP event is not significantly different from neutral or even La Niña years.

Boucharel, Julien↗

Non-conservation and conservation for different formulations of moist potential vorticity

Potential vorticity (PV) is one of the most important quantities in atmospheric science. In the absence of dissipative processes, the PV of each fluid parcel is known to be conserved, for a dry atmosphere. However, a parcel's PV is not conserved if clouds or phase changes of water occur. Recently, PV conservation laws were derived for a cloudy atmosphere, where each parcel's PV is not conserved but parcel-integrated PV is conserved, for integrals over certain volumes that move with the flow. Hence a variety of different statements are now possible for moist PV conservation and non-conservation, and in comparison to the case of a dry atmosphere, the situation for moist PV is more complex. Here, in light of this complexity, several different definitions of moist PV are compared for a cloudy atmosphere. Numerical simulations are shown for a rising thermal, both before and after the formation of a cloud. These simulations include the first computational illustration of the parcel-integrated, moist PV conservation laws. The comparisons, both theoretical and numerical, serve to clarify and highlight the different statements of conservation and non-conservation that arise for different definitions of moist PV.

54 ENVIRONMENTAL SCIENCES↗

Self‐Assembly Methods Induce Different Individual‐Polymer‐Block Solvation Responses

An understanding of block-specific responses to stimuli in self-assembled copolymers is essential for the effective design of responsive materials. Here, materials formed from different post-reaction processing methods of the same ROMP block copolymer exhibit different block-specific solvent responses, as characterized in situ by fluorescence lifetime imaging microscopy (FLIM). FLIM data were acquired by tagging the polar or nonpolar block separately with a covalently incorporated viscosity-sensitive fluorescent molecular rotor to measure the changing tightness or looseness of assembly upon changes in solvent composition. Rapid precipitation from an insoluble solvent to form a film results in tighter assembly and less difference in tightness/looseness between the two blocks. Further, it interrupts individual block-solvent response behavior. Both results indicate an apparent disruption of the core–shell assembly. This model from FLIM is further supported by differential scanning calorimetry (DSC) and small-angle X-ray scattering (SAXS) data from isolated solids, which show tighter long-range interactions and more long-range order in these kinetically trapped states. Here, the experiments develop FLIM as a method for pinpointing stimuli-responsive behaviors from different processing methods to individual blocks. Together these outcomes provide a future handle for tailoring solvent-triggered assembly/disassembly behavior.

López, Pía A. [University of California, Irvine, C↗

Analysis of Dynamical Peculiarities in Nanoalloys at Subsystems Level: Dynamical Degrees of Freedom, Temperature Differences, and the Chameleon Effect

Abstract A novel analysis of the dynamical behavior of nanoalloy systems, as represented by model Ni/Al 13‐atom clusters, over a broad range of energies that cover the stage‐wise transition of the systems from their solid‐like to liquid‐like state is presented. Conceptually, the analysis is rooted in partitioning the systems into judiciously chosen subsystems and characterizing the latter in terms of subsystem‐specific dynamical descriptors that include dynamical degrees of freedom , root‐mean‐square bond‐length fluctuation , and element‐specific subsystem temperature . The analysis reveals a host of intriguing new peculiarities in the dynamical behavior of the Ni/Al 13‐mers, among which are what we call the chameleon effect and the difference in the temperatures of the Ni and Al subsystems at high energies, a difference that strongly depends on the cluster composition and also changes with energy. These do not have an analog in pure Ni 13 and Al 13 and are explained in terms of the coupled effects of the difference between the masses of the Ni and Al atoms (the mass effect) and of the difference in the anharmonicity of the overall interaction potential as experienced by the Ni and Al subsystems of the clusters (the potential effect).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Newly developed sugarbeet lines with altered postharvest respiration rates differ in transcription factor and glycolytic enzyme expression

Respiration is the principal cause for postharvest sucrose loss in sugarbeet (Beta vulgaris L.) roots. Although reductions in respiration rate could mitigate these losses, developing sugarbeet cultivars and storage procedures that reduce respiration are hindered by a lack of knowledge of the genetic and metabolic factors that control storage respiration rate. Research was conducted to identify genes and gene products that affect storage respiration rate by creating two sugarbeet lines that differ in respiration rate and characterizing gene expression differences between these lines. Sugarbeet lines F1056 and F1057, which differ by up to 42% in respiration rate, were created by divergent selection of a sugarbeet population using root respiration rate after 30 d in storage as the principal selection criterion. RNA sequencing identified 287 differentially expressed genes (DEGs) between these lines on the day of harvest and after 28-d storage. Of these DEGs, nine encoded transcription factors and five encoded enzymes involved in the respiratory pathway. Other DEGs contributed to a variety of biological and molecular functions based on gene ontology classifications. Of respiratory pathway DEGS, genes for NAD+- and NADP+-dependent forms of glyceraldehyde-3-phosphate dehydrogenase were of note due to their high upregulation in the high respiring line and for their established role in glycolysis, a pathway identified as a likely bottleneck in respiratory substrate production. Overall, lines F1056 and F1057 provide new tools for investigating genetic and physiological differences in storage respiration rate, and their DEGs identify candidates for genes affecting sugarbeet root respiration rate.

59 BASIC BIOLOGICAL SCIENCES↗

Mechanistic Differences between Electrochemical Hydrogenation and Hydrogenolysis of 5‐Hydroxymethylfurfural and Their pH Dependence

Abstract Hydrogenation and hydrogenolysis are two important reactions for electrochemical reductive valorization of biomass‐derived oxygenates such as 5‐hydroxymethylfurfural (HMF). In general, hydrogenolysis (which combines hydrogenation and deoxygenation) is more challenging than hydrogenation (which does not involve the cleavage of carbon–oxygen bonds). Thus, identifying factors and conditions that can promote hydrogenolysis is of great interest for reductive valorization of biomass‐derived oxygenates. For the electrochemical reduction of HMF and its derivatives, it is known that aldehyde hydrogenation is not a part of aldehyde hydrogenolysis but rather a competing reaction; however, no atomic‐level understanding is currently available to explain their electrochemical mechanistic differences. In this study, combined experimental and computational investigations were performed using Cu electrodes to elucidate the key mechanistic differences between electrochemical hydrogenation and hydrogenolysis of HMF. The results revealed that hydrogenation and hydrogenolysis of HMF involve the formation of different surface‐adsorbed intermediates via different reduction mechanisms and that lowering the pH promoted the formation of the intermediates required for aldehyde and alcohol hydrogenolysis. This study for the first time explains the origins of the experimentally observed pH‐dependent selectivities for hydrogenation and hydrogenolysis and offers a new mechanistic foundation upon which rational strategies to control electrochemical hydrogenation and hydrogenolysis can be developed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of Cadmium Bioavailability in Food on Its Distribution in Different Tissues in the Ground Beetle Pterostichus oblongopunctatus

In most laboratory studies with oral exposure of terrestrial invertebrates to metals an artificial food, which is easy to handle, is used. The bioavailability of metals from this artificial food may, however, be much higher than from more field relevant food sources. Such differences may affect toxicokinetic processes in different tissues. To test the effect of bioavailability of Cd in food on Cd toxicokinetics and internal distribution in terrestrial invertebrates, we performed the experiment using the ground beetle Pterostichus oblongopunctatus exposed to Cd via food differing in their soluble Cd pool. We showed that in carabids Cd accumulation and elimination pattern in different tissues is not governed by the metal availability in food.

54 ENVIRONMENTAL SCIENCES↗

Percutaneous Biopsy of Osteoid Osteomas Prior to Percutaneous Treatment Using Two Different Biopsy Needles

Biopsy is usually performed as the first step in percutaneous treatment of osteoid osteomas prior to laser photocoagulation. At our institution, 117 patients with a presumed diagnosis of osteoid osteoma had a trephine biopsy before a percutaneous laser photocoagulation. Biopsies were made using two different types of needles. A Bonopty biopsy needle (14-gauge cannula, 16-gauge trephine needle; Radi Medical Systems, Uppsala, Sweden) was used in 65 patients, and a Laurane biopsy needle (11-gauge cannula, 12.5-gauge trephine needle; Laurane Medical, Saint-Arnoult, France) in 43 patients. Overall biopsy results were positive for osteoid osteoma in 83 (70.9%) of the 117 cases. The Laurane needle provided a significantly higher positive rate (81.4%) than the Bonopty needle (66.1%; p < 0.05). This difference was not due to the size of the nidus, which was similar in the two groups (p < 0.05) and may be an effect of differences in needle caliber (12.5 vs. 14 gauge) as well as differences in needle design. The rate of positive biopsy results obtained in the present series with the Laurane biopsy needle is, to our knowledge, the highest rate reported in series dealing with percutaneous radiofrequency ablation and laser photocoagulation of osteoid osteomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stent Retriever Thrombectomy in Different Thrombus Locations of Anterior Cerebral Circulation

BackgroundMechanical thrombectomy (MT) is a safe and efficient treatment for acute ischemic stroke in patients with proximal anterior occlusion and large penumbra. We evaluated the technical and clinical success of MT in relation to the location of the occlusion (internal carotid artery, M1 and M2 segments of the middle cerebral artery).MethodsWe prospectively reviewed 130 patients of whom 105 met the inclusion criteria. Baseline clinical, procedural and imaging variables, technical outcome (TICI, thrombolysis in cerebral infarction), 24 h imaging outcome and three-month clinical outcome (mRS, modified Rankin Scale) were recorded. Differences between the groups were studied with statistical tests according to the type of the variable.ResultsThere were 37, 46 and 22 patients in the internal carotid artery (ICA), M1 and M2 groups, respectively. TICI 2b or 3 was achieved in 92 cases (88 %) with a non-significant trend towards a better recanalization outcome in the ICA and M1 groups. Overall, 57 of the 105 patients (55 %) experienced favorable clinical outcome (mRS ≤ 2) with no significant differences between the groups. Excellent outcome (mRS ≤ 1) was seen in 40 patients (39 %) and there proportionally more patients with excellent outcome in the ICA and M1 groups (ICA: 44 %, M1: 41 %, M2: 23 % of patients, p = 0.22).ConclusionsThere were no statistically significant differences in the technical or clinical outcomes between the different sites of occlusion (ICA, M1 or M2). There was a non-significant trend towards achieving excellent clinical outcome (3-month mRS ≤ 1) more often and better recanalization results in the two more proximal locations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pharmacokinetic Evaluation of Two Paclitaxel-Coated Balloons with Different Drug Load in a Short-Term Porcine Study

PurposeThe aim of the study was to evaluate the pharmacokinetics and tissue absorption of 2 paclitaxel (PTX) drug-coated balloons (DCB) using different drug loads in a porcine-injured iliac artery model.Materials and MethodsTwenty-eight pigs were randomized into 2 groups. In group B1, angioplasty was performed with a 1.0 µg/mm{sup 2} DCB with PTX and in group B3, with a 3.0 µg/mm{sup 2} DCB with PTX. An overstretched model of the iliac artery was used for angioplasty under fluoroscopy. Blood and vessel wall PTX were measured with liquid-chromatography mass spectrometry at 1, 5, 30 min, 1, 7, and 28 days. Remaining drug in the balloon was analyzed.ResultsMean PTX in blood was significantly higher in the group B3 0.269 ± 0.085 µg/ml compared with the B1 0.218 ± 0.085 µg/ml; p = 0.01. Peak blood PTX concentration was detected at 1 min, and PTX was undetectable 24 h post-angioplasty. There were no statistically significant differences in the mean arterial wall concentration from the treated iliac artery between group-B1 (15.24 ± 21.29 ng/mg) and B3 (15.68 ± 16.33 ng/mg), or in the PTX wall concentration measured at different time points. Mean remaining drug in assayed balloons was lower for group-B1 and represented 8 % of the initial dose.ConclusionsBlood PTX was higher when using 3.0 µg/mm{sup 2} DCB, with a peak drug concentration at 1-min, although the drug was undetectable at 24 h, independently of the loading dose. This study demonstrates no difference in arterial wall uptake of a low dose DCB (1.0 µg/mm{sup 2}), when compared to a common dose DCB (3.0 µg/mm{sup 2}) suggesting that the dose of drug in the DCB could be reduced obtaining a similar clinical effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing free tropospheric quasi-equilibrium for different GCM resolutions using a cloud-resolving model simulation of tropical convection

Abstract This study examines the free-tropospheric quasi-equilibrium at different global climate model (GCM) resolutions using the simulation of tropical convection by a cloud-resolving model during the Tropical Western Pacific International Cloud Experiment. The simulated dynamic and thermodynamic fields within the model domain are averaged over subdomains of different sizes equivalent to different GCM resolutions. These coarse-grained fields are then used to compute CAPE and its change with time, and their relationships with simulated convection. Results show that CAPE change with time is controlled predominantly by variations of thermodynamic properties in the planetary boundary layer for all subdomain sizes ranging from 64 to 4 km. Lag correlation analysis shows that CAPE generation by the free-tropospheric dynamical advection (dCAPE ls ) leads convective precipitation but is in phase with convective mass flux at 600 mb and 500 mb vertical velocity for all subdomain sizes. However, the correlation coefficients and regression slopes decrease as the subdomain size decreases for subdomain sizes smaller than 16 km. This is probably due to increased randomness of convection and more scale-dependence of the relationships when the subdomain size reaches the grey zone. By examining the sensitivity of the relationships of convection with dCAPE ls to temporal scales in different subdomain size, it shows that the quasi-equilibrium between dCAPE ls and convection holds well for timescales of 30 min or longer at all subdomain sizes. These results suggest that the free tropospheric quasi-equilibrium assumption may still be useable even for GCM resolutions in the grey zone.

54 ENVIRONMENTAL SCIENCES↗

Corrosion Behavior of Pipeline Steel with Different Microstructures Under AC Interference in Acid Soil Simulation Solution

Corrosion behavior of X65 pipeline steels with different microstructures under alternating current (AC) interference was investigated in acid soil simulation solution by potentiodynamic polarization curve, potentiostatic polarization curve and immersion test. The results show that superimposed AC causes a sharp increase in corrosion current density of X65 steel. With the increase in i{sub AC}, the corrosion current densities of steels with various microstructures increase, especially at high i{sub AC}. Hot-rolled steel mainly experiences uniform corrosion, with very slight pit corrosion. Serious corrosion degrees with intensive corrosion pits can be observed on the surfaces of normalized and quenched microstructure steels. The annealed steel exhibits the feature of non-uniform corrosion with some pitting. The steels with various microstructures applied with AC have different corrosion resistance. The normalized steel shows the worst corrosion resistance, then the quenched microstructure, and the hot-rolled steel displays the optimum corrosion resistance. The difference in the microstructure can result in difference in corrosion degree and occurrence position of pitting corrosion of X65 steel. The normalized microstructure composed of polygonal ferrite and a large amount of pearlite and bainite is the most susceptible to AC corrosion.

36 MATERIALS SCIENCE↗

Microstructure and Mechanical Behavior of Friction Stir-Welded Sc-Modified Al-Zn-Mg Alloys Made Using Different Base Metal Tempers

The microstructure and property of friction stir weld joints of a Sc-modified Al-Zn-Mg alloy developed using base metal in hot-rolled (HR) and T6 temper were studied and compared in this work. The results showed that the microstructure and property exhibited significant difference between the two friction stir weld joints. The weld efficiency of the FSW joint developed using base metal in HR condition is over 90%, while that of the FSW joint developed using base metal in T6 condition is only 70%. The hardness of the weld nugget of HR joint is obviously higher than that of the weld nugget of T6 joint, due to the different changes in the original precipitates during the friction stir welding process. The strengthening mechanism in different zones of the two FSW joints was discussed to examine the microstructure–properties relationship, and the main difference of the strengthening mechanism between the two FSW joints was revealed.

36 MATERIALS SCIENCE↗

Comparison of Simultaneous Shock Temperature Measurements from Three Different Pyrometry Systems

Pyrometry is one of the most prevalent techniques for measuring temperature in shock physics experiments. However, the challenges of applying pyrometry in such highly dynamic environments produces multiple sources of uncertainty that require investigation. An outstanding question is the degree of agreement between different pyrometers and different experiments. Here we report a series of novel plate impact experiments with simultaneous thermal radiance measurements using three different multi-wavelength optical pyrometry systems, each with different spatial and temporal resolutions, on samples shocked to identical states. We compare the temperatures measured by each system and their associated uncertainties using a number of emissivity assumptions. The results shown that the measurements from all three systems agree within uncertainty. Furthermore, some non-thermal light contamination was observed despite a number of prevention measures.

36 MATERIALS SCIENCE↗

Analytical solutions for quantum walks on 1D chain with different shift operators

In this paper, we study the discrete-time quantum walks on 1D Chain with the moving and swapping shift operators. We derive analytical solutions for the eigenvalues and eigenstates of the evolution operator U{sup -hat} using the Chebyshev polynomial technique, and calculate the long-time averaged probabilities for the two different shift operators respectively. It is found that the probability distributions for the moving and swapping shift operators display completely different characteristics. For the moving shift operator, the probability distribution exhibits high symmetry where the probabilities at mirror positions are equal. The probabilities are inversely proportional to the system size N and approach to zero as N→∞. On the contrary, for the swapping shift operator, the probability distribution is not symmetric, the probability distribution approaches to a power-law stationary distribution as N→∞ under certain coin parameter condition. We show that such power-law stationary distribution is determined by the eigenstates of the eigenvalues ±1 and calculate the intrinsic probability for different starting positions. Our findings suggest that the eigenstates corresponding to eigenvalues ±1 play an important role for the swapping shift operator. - Highlights: • QWs on 1D chain with the moving and swapping operators are studied for the first time. • We derive analytical results for the probability distribution for the two operators. •We compare the dynamics of QWs with two different shift operators. • We find the particular eigenvalues ±1 play an important role for the dynamics. • We use the Chebyshev technique to treat the problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Differences in the catalytic mechanisms of mesophilic and thermophilic indole-3-glycerol phosphate synthase enzymes at their adaptive temperatures

Highlights: Black-Right-Pointing-Pointer Catalytic mechanisms of thermophilic-mesophilic enzymes may differ. Black-Right-Pointing-Pointer Product release is rate-determining for thermophilic IGPS at low temperatures. Black-Right-Pointing-Pointer But at higher temperatures, proton transfer from the general acid is rate-limiting. Black-Right-Pointing-Pointer Rate-determining step is different still for mesophilic IGPS. Black-Right-Pointing-Pointer Both chemical and physical steps of catalysis are important for temperature adaptation. -- Abstract: Thermophilic enzymes tend to be less catalytically-active at lower temperatures relative to their mesophilic counterparts, despite having very similar crystal structures. An often cited hypothesis for this general observation is that thermostable enzymes have evolved a more rigid tertiary structure in order to cope with their more extreme, natural environment, but they are also less flexible at lower temperatures, leading to their lower catalytic activity under mesophilic conditions. An alternative hypothesis, however, is that complementary thermophilic-mesophilic enzyme pairs simply operate through different evolutionary-optimized catalytic mechanisms. In this communication, we present evidence that while the steps of the catalytic mechanisms for mesophilic and thermophilic indole-3-glycerol phosphate synthase (IGPS) enzymes are fundamentally similar, the identity of the rate-determining step changes as a function of temperature. Our findings indicate that while product release is rate-determining at 25 Degree-Sign C for thermophilic IGPS, near its adaptive temperature (75 Degree-Sign C), a proton transfer event, involving a general acid, becomes rate-determining. The rate-determining steps for thermophilic and mesophilic IGPS enzymes are also different at their respective, adaptive temperatures with the mesophilic IGPS-catalyzed reaction being rate-limited before irreversible CO{sub 2} release, and the thermophilic IGPS-catalyzed reaction being rate limited afterwards.

60 APPLIED LIFE SCIENCES↗