Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Quantum state preparation and nonunitary evolution with diagonal operators

Realizing nonunitary transformations on unitary-gate-based quantum devices is critically important for simulating a variety of physical problems, including open quantum systems and subnormalized quantum states. Here, we present a dilation-based algorithm to simulate nonunitary operations using probabilistic quantum computing with only one ancilla qubit. We utilize the singular-value decomposition (SVD) to decompose any general quantum operator into a product of two unitary operators and a diagonal nonunitary operator, which we show can be implemented by a diagonal unitary operator in a one-qubit dilated space. While dilation techniques increase the number of qubits in the calculation, and thus the gate complexity, our algorithm limits the operations required in the dilated space to a diagonal unitary operator, which has known circuit decompositions. We use this algorithm to prepare random subnormalized two-level states on a quantum device with high fidelity. Furthermore, we present the accurate nonunitary dynamics of two-level open quantum systems in a dephasing channel and an amplitude-damping channel computed on a quantum device. The algorithm presented will be most useful for implementing general nonunitary operations when the SVD can be readily computed, which is the case for most operators in the noisy intermediate-scale quantum computing era.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In operando cryo-STEM of pulse-induced charge density wave switching in TaS 2

The charge density wave material 1T-TaS 2 exhibits a pulse-induced insulator-to-metal transition, which shows promise for next-generation electronics such as memristive memory and neuromorphic hardware. However, the rational design of TaS 2 devices is hindered by a poor understanding of the switching mechanism, the pulse-induced phase, and the influence of material defects. Here, we operate a 2-terminal TaS 2 device within a scanning transmission electron microscope at cryogenic temperature, and directly visualize the changing charge density wave structure with nanoscale spatial resolution and down to 300 μs temporal resolution. We show that the pulse-induced transition is driven by Joule heating, and that the pulse-induced state corresponds to the nearly commensurate and incommensurate charge density wave phases, depending on the applied voltage amplitude. With our in operando cryogenic electron microscopy experiments, we directly correlate the charge density wave structure with the device resistance, and show that dislocations significantly impact device performance. This work resolves fundamental questions of resistive switching in TaS 2 devices, critical for engineering reliable and scalable TaS 2 electronics.

36 MATERIALS SCIENCE↗

Kinetic equilibrium reconstructions of plasmas in the MAST database and preparation for reconstruction of the first plasmas in MAST upgrade

Reconstructions of plasma equilibria using magnetic sensors were routine during operation of the Mega Ampere Spherical Tokamak (MAST) device, but reconstructions using kinetic profiles were not. These are necessary for stability and disruption analysis of the MAST database, as well as for operation in the upgrade to the device, MAST-U. The three-dimensional (3D) code VALEN is used to determine eddy currents in the 3D vessel structures for vacuum coil test shots, which are then mapped to effective resistances in the two-dimensional vessel groupings in the EFIT equilibrium reconstruction code to be used in conjunction with nearby loop voltage measurements for estimated currents in the structures during reconstruction. Kinetic equilibrium reconstructions with EFIT, using all available magnetic sensors as well as Thomson scattering measurements of electron temperature and density, charge exchange recombination spectroscopy measurements of ion temperature, and internal magnetic field pitch angle measurements from a motional Stark effect (MSE) diagnostic are performed for a large database of MAST discharges. Excellent convergence errors are obtained for the portions of the discharges where the stored energy was not too low, and it is found that reconstructions performed with temperature and density measurements but without MSE data usually already match the pitch angle measurements well. A database of 275 kinetic equilibria is used to test the ideal MHD stability calculation capability for MAST. In conclusion, the necessary changes to conducting structure in VALEN, and diagnostic setup in EFIT have been completed for the upgrade from MAST to MAST-U, enabling kinetic reconstructions to commence from the first plasma discharges of the upgraded device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrasound Interim cyber-physical research evaluation

Recent events have presented Medical Practitioners with concerns about safety and privacy implications associated with GE’s VScan MIot Ultrasound Device. Concerns relate to the devices potential risk to broadcast location data that can pose serious risks to device users and patients. This report was commission in collaboration with Augusta University to determine if device concerns pose real threat to operators and patients. In effort to ensure all potential threat vectors are targeted, the initial step was to analyze the supply chain. Here the devices are CT scanned to look for any hardware anomalies that could present threat vectors to users of these devices. (See SRNL-STI-2024-00225 for detailed analysis). No anomalies were found associated with the hardware utilized within the GE VScan Air.

42 ENGINEERING↗

Transport from electron-scale turbulence in toroidal magnetic confinement devices

Plasma transport driven by turbulence ultimately determines the energy confinement performance of controlled fusion devices regardless of their confinement schemes and configurations. A large variety of plasma instabilities have been proposed for driving turbulence responsible for anomalous plasma transport beyond classical/neoclassical transport due to collisions. Although ion-scale turbulence usually dominates due to its large eddy size and saturation level, electron-scale turbulence has been recognized to be important in regions where ion-scale turbulence is suppressed (e.g., in internal transport barrier and in spherical tokamak H-mode plasmas) or is close to marginality. Electron-scale turbulence has been shown to nonlinearly interact with ion-scale turbulence, which modifies the dynamics of both and affects the resulting plasma transport, particularly when ion-scale instability is weakly driven. In this review paper, we focus on electron-scale turbulence that is believed to operate in magnetically confinement fusion devices and aim to provide a review of theoretical, numerical, and experimental developments in understanding electron-scale turbulence and its role in driving anomalous plasma turbulence. In particular, we focus on the electrostatic electron temperature gradient (ETG) mode which is the most widely recognized plasma instability underlying electron-scale turbulence observed in magnetically confined plasmas. Finally, we note that there are other less studied instabilities that might be responsible for observed electron-scale turbulence, most notably ubiquitous mode, and short-wavelength ion temperature gradient (SWITG) mode, which will be briefly touched on in this review.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Topology optimization of compliant mechanisms under transient thermal conditions

This work considers multi-material topology optimization of compliant mechanisms under transient thermal and quasi-static mechanical conditions wherein thermally actuated devices are optimized for different operating conditions. The materials are modeled using finite strain thermo-hyperelasticity and a two way coupling between the energy balance and equilibrium equations is investigated. The design updates are generated from the gradient-based method of moving asymptotes optimizer and the sensitivities are computed using the time dependent adjoint sensitivity analysis. Results show the impact of designing for short versus long actuation times.

42 ENGINEERING↗

Disruption modelling for engineering and physics design of ST-E1 fusion power plant

Plasma disruptions represent a critical challenge for high-performance tokamak operations, as they can compromise machine integrity and reduce operational availability. Although future fusion devices essentially need to incorporate strategies to minimise disruption occurrence, complete avoidance remains unattainable. Consequently, assessing and characterising unmitigated disruption consequences is fundamental for the design and qualification of next-generation fusion power plants. This work supports the pre-conceptual design of ST-E1, a low aspect-ratio Tokamak Fusion Power Plant developed by Tokamak Energy Ltd., by presenting a comprehensive disruption modelling approach applied across different design stages. The methodology integrates both physics and engineering considerations to evaluate the impact of disruptions on machine performance and structural integrity. From an engineering perspective, several ST-E1 layout options were analysed to investigate the electromagnetic response of key components under disruption-induced loads, enabling comparison between alternative design solutions. On the physics side, a broad set of disruption scenarios was explored, scanning operational space parameters, plasma-material interactions, and associated thermal loads. Furthermore, the study examined variations in disruption behaviour arising from different reference equilibria, focusing on a range starting from Double Null to Single Null configurations, reflecting the increasing up-down asymmetry consequences. The results reveal significant contrasts in plasma dynamics and structures electromagnetic behaviour between configurations, highlighting the importance of disruption modelling in guiding design choices. These analyses have proven instrumental in shaping ST-E1 development, offering critical insights for mitigating risks and optimising future fusion power plant designs.

Borowiec, Katarzyna [ORNL] (ORCID:0000000335911739↗

MPEX High Heat Flux Plasma Dump Design, Manufacture, and Articles Test

Here, the Material Plasma Exposure eXperiment (MPEX) device is a steady-state linear plasma device currently in the final design phase at the Oak Ridge National Laboratory. This device will reach ion fluences up to 10 31 m -2 and will be used to expose neutron-irradiated materials to divertor-relevant plasmas and to study the effects of plasma-material interactions. These studies will elucidate the complex effects of plasmas with divertor candidate materials capable of withstanding high heat flux and high fluences for next-generation fusion devices. Bidirectional plasma will be generated using a high-power (200 kW) helicon source. Plasma will be confined by superconducting magnets. The last plasma-facing component on the upstream side of the MPEX device is the dump, which has been designed to intercept plasma and energetic particles. The dump will have a total heat load of 9.2 kW. A copper alloy (Glidcop AL-15) was selected for use in the water-cooled flange design because of its high thermal conductivity, its retaining strength at elevated temperatures, and its ability to be used in the high-temperature braze joints used in this application. Titanium-zirconium-molybdenum (TZM) tiles are brazed to the Glidcop AL-15 flange using high-temperature braze alloy. External water-cooling channels are used on the dump flange to prevent water leakage inside the vacuum space. This article discusses the details of the high heat flux dump design, including the computational fluid dynamics (CFD) and structural analyses performed to validate the design to meet the operational requirements of the MPEX device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robust and resilient coordination of feeders with uncertain distributed energy resources: from real-time control to long-term planning

To enable flexible demand and ensure reliable and economical operation of distribution systems, we present a novel hierarchical scheme that actively coordinates responsive behind-the-meter grid resources, including distributed energy resources (DERs), to reliably manage each unbalanced distribution feeder and exploits the available flexibility to economically optimize the entire network. Each layer of the scheme employs advanced optimization methods at different timescales to ensure that the system operates within both grid and device limits. The hierarchy is validated in a large-scale realistic simulation based on data from the industry. Simulation results show that coordination of flexibility improves both system reliability and economics, and enables greater penetration of solar PV. Discussion is also provided on the practical viability of the required communications and controls to implement the presented scheme within a large DSO.

14 SOLAR ENERGY↗

Hierarchical, Grid-Aware, and Economically Optimal Coordination of Distributed Energy Resources in Realistic Distribution Systems

Renewable portfolio standards are targeting high levels of variable solar photovoltaics (PV) in electric distribution systems, which makes reliability more challenging to maintain for distribution system operators (DSOs). Distributed energy resources (DERs), including smart, connected appliances and PV inverters, represent responsive grid resources that can provide flexibility to support the DSO in actively managing their networks to facilitate reliability under extreme levels of solar PV. This flexibility can also be used to optimize system operations with respect to economic signals from wholesale energy and ancillary service markets. Here, we present a novel hierarchical scheme that actively controls behind-the-meter DERs to reliably manage each unbalanced distribution feeder and exploits the available flexibility to ensure reliable operation and economically optimizes the entire distribution network. Each layer of the scheme employs advanced optimization methods at different timescales to ensure that the system operates within both grid and device limits. The hierarchy is validated in a large-scale realistic simulation based on data from the industry. Simulation results show that coordination of flexibility improves both system reliability and economics, and enables greater penetration of solar PV. Discussion is also provided on the practical viability of the required communications and controls to implement the presented scheme within a large DSO.

distribution network↗

Iodine’s Wild Ride Leading to Photoinstability in Halide Perovskite Solar Cells

Understanding processes that contribute to efficiency losses during long-term operation of perovskite solar cells is crucial for achieving operational stability. Although maximum power point tracking optimizes outdoor performance, it is not uncommon that devices are kept under open-circuit conditions during sunny hours. Under these conditions, charge carriers accumulate at the interfaces rather than flowing through the circuit. In the case of the MAPbI 3 /spiro-OMeTAD interface studied here, hole accumulation leads to formation of I2 and subsequent oxidation of spiro-OMeTAD. By employing in situ absorption measurements, we show that the decrease in power conversion efficiency follows the spiro-OMeTAD oxidation while operating the device under open-circuit conditions. In short-circuit conditions, where photogenerated charge carriers are extracted in the external circuit, the I 2 -induced oxidation of spiro-OMeTAD and the device instability are minimized. The photoinduced expulsion of iodine from MAPbI 3 into spiro-OMeTAD discussed in this work provides new insight into the photoinstability of perovskite solar cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrically-driven IMT and volatile memristor behavior in NdNiO 3 films

Abstract Transition metal oxides with insulator-metal transitions (IMTs) are uniquely suited for volatile memristor devices that mimic the spiking of biological neurons. Unlike most non-volatile memristors, which often operate via ion migration into filaments, volatile devices utilize a reversible phase change that returns to a ground state in the absence of applied stimulus. In these devices, Joule heating triggers the IMT and changes the bulk resistivity rather than influencing conduction through defects, as in previous studies. This volatile resistive switching behavior has previous been leveraged in niobium and vanadium oxides, but not in rare-earth nickelates, despite their tunable transition temperatures. This study demonstrates an electrically driven IMT in the prototypical rare-earth nickelate, NdNiO 3 , in large area devices. While previous work examining the electrically-driven IMT in NdNiO 3 suggests defect-dominated conduction, this study shows clear s-type negative differential resistance (NDR) consistent with temperature-dependent resistivity measurements. The NDR peak-to-valley voltage scales linearly with temperature as expected for conductivity pathways dominated by bulk IMT behavior. Unlike other transition metal oxides, which are modeled using the insulator-metal phase fraction as the internal state variable, a thermoelectric model with temperature as the internal state variable is found to more accurately describe the current–voltage characteristic of NdNiO 3 volatile memristors. Overall, we report the synthesis, fabrication, and characterization of NdNiO 3 volatile memristors with resistivity dominated by bulk-like IMT behavior which is scalable and not dependent upon oxygen vacancy migration or defect mediated conduction pathways.

36 MATERIALS SCIENCE↗

Two-phase separator device for removing condensate or particulate from a gas stream

This disclosure provides a two-phase separator device for separating condensate or particulate from a gas stream. In some implementations, the separator device removes water from air and may operate under micro-gravity conditions. The gas stream flows through the two-phase separator device and passes through a rotatable vane assembly along a flow path without being redirected in another flow path. Condensate or particulate in the gas stream is impacted by a plurality of vanes of the rotatable vane assembly, and the condensate is captured by features formed within the plurality of vanes. The captured condensate is accelerated radially outwardly along the each of the plurality of vanes towards a sloped inner wall, and further moved along the sloped inner wall in a direction against the flow path of the gas stream during rotation.

Cognata, Thomas↗

Electrical and thermal characteristics of LaB6 thermionic hollow cathodes operating in He, D2, Ar, and Xe at 4–200 Pa and 0.25–5 A cm−2

We report characteristics of lanthanum hexaboride (LaB6) cathodes for conditions relevant to a high-voltage, high-current switching device. LaB6 is selected because of its relatively low work function, stability in the presence of many common gas impurities, and a low evaporation rate (long life) at operating temperatures. We have investigated the effect of cathode geometry, gas type, pressure, and current on a LaB6 hollow cathode in a diode configuration with an opposing planar anode. The gas is stagnant at a relatively low pressure of 4–200 Pa (0.03–1.5 Torr) because of device high-voltage standoff requirements. In all cases, the plasma voltage decreases to a plateau value with increasing current where a practical device would operate. The plateau voltage aligns with the fill gas excitation or ionization voltage, depending on conditions. At high current, the cathode temperature exceeds that required for thermionic emission to supply the total current, a behavior that is understood by accounting for back-diffusing bulk electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of MHD stability and active mode control on KSTAR for high confinement, disruption-free plasma

Long-pulse plasma operation at high normalized beta, $β_N$, above the $\textit{n}$= 1 ideal MHD no-wall stability limit in KSTAR is presently limited by tearing instabilities rather than resistive wall modes. H-mode plasma operation during the recent KSTAR device campaign produced discharges having strong $\textit{m/n}$= 2/1 tearing instabilities at $β_N$ lower than the ideal MHD no-wall beta limit. The unstable tearing mode consequently reduced plasma confinement and toroidal plasma rotation significantly. We report the experiment confirmed that an extended duration of electron cyclotron heating (ECH) at the initial phase of the discharge plays a critical role in mode destabilization. To study destabilizing mechanisms that affect the mode growth, the stability of the observed tearing modes from plasmas with significantly different $β_N$ is computed by using the resistive DCON code and the M3D-C 1 code. Equilibrium reconstructions that include constraints from internal profile diagnostics, and computed fast particle pressure are used as input for reliable computation of stability. The classical tearing stability index, Δ', from resistive DCON is computed to be unstable when the island is fully saturated with large amplitude, while the unstable mode is not computed by M3D-C 1 . The modified Rutherford equation (MRE) describing the evolution of the island width has been constructed for KSTAR plasmas by using plasma parameters computed by the TRANSP code. The MRE model estimates a saturated island width corresponding to ~10% of the plasma minor radius for equilibrium at high $β_N$ 3 having a stable Δ' from the resistive DCON. In preparation for long-pulse plasma operation at higher beta utilizing increased plasma heating power, a resistive wall mode (RWM) active feedback control algorithm has been completed and enabled on KSTAR. To accurately determine the $\textit{n}$= 1component produced by RWMs, an algorithm has been developed that includes magnetic sensor compensation of the prompt applied field and the field from the induced current on the passive conductors. Use of multiple toroidal sensor arrays is enabled by modifying the sensor toroidal angles assumed in mode decomposition to include the effect of varied mode helicities in the outboard region where the mode measurement is made. This analysis on stability, transport, and control provides the required foundation for disruption prediction and avoidance research on KSTAR.

resistive wall mode (RWM)↗

Color‐Stable, All‐Phosphorescent White Organic Light Emitting Diodes Using the Polariton‐Enhanced Purcell Effect

Abstract The short operational lifetimes of high efficiency phosphorescent organic blue light emitting devices (PHOLEDs) has limited their use in displays and lighting. Previously, this problem has been avoided by using less efficient fluorescent blue devices in separately biased red, green, and blue emissive elements to achieve stable full color emission. However, the operational lifetime of blue phosphorescent OLEDs has been significantly improved through the utilization of the plasmon‐exciton‐polariton‐enhanced (PEP) Purcell effect. Here, a white emitting PHOLED comprising stacked red, green, and blue elements is demonstrated that exploits PEPs to extend the operational lifetime of the blue element such that all emissive layers degrade at the same rate. The device features white light emission with an external quantum efficiency of 19.1 ± 0.4%, luminous power efficiency of 13.3 ± 0.3 lm W −1 at a luminance of 1000 cd m −2 when measured over 4π solid angle, with a color rendering index of 76 unchanged throughout the device aging to 70% of its initial luminance, T 70 . A 2.9 times enhancement in the operational lifetime of the Purcell‐enhanced device is achieved to yield T 70 = 2900 ± 100 h for an initial luminance of 1000 cd m −2 , compared to devices lacking this enhancement with T 70 = 1000 ± 100 h.

36 MATERIALS SCIENCE↗