Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “delay errors.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Multi-scale dynamic modeling and validation of radial flow fixed bed contactors for post-combustion CO 2 capture using bench scale and pilot plant data

Here, in this work, a multi-scale model of a radial flow fixed bed contactor packed with a carbon sorbent is developed and validated with laboratory-scale and pilot plant scale dynamic data. For the lab scale system, the model results were compared with low, medium and high gas and sweep flowrates, yielding root mean square error (RMSE) of 0.80, 0.63, 0.96 CO 2 mol%, respectively, for the outlet CO 2 concentration profile considering the entire A-D cycle. For the bed outer temperature profile, maximum RMSE was found to be 5.5 °C considering all flowrates and entire A-D cycles. An experimental campaign was developed and applied to a pilot plant at Technology Center Mongstad (TCM), Norway. Approaches were developed for pre-processing of data including consideration of the effect of gas mixing, measurement delay, and determination of cyclic steady-state conditions. Considering profiles during A-D cycles for all test runs, it was found that the maximum RMSE for pressure drop, temperature for the outer section of the bed, temperature for the middle section of the bed, and outlet CO 2 concentration profile remained less than 1.5 mbar, 3.5 °C, 2.8 °C, and 1.3 CO 2 mol%, respectively. The validated model was used to perform sensitivity studies on several key design operating variables for the adsorption-desorption cycle. It was found that the flow rate and concentration of flue gas have dominant nonlinear effects on the breakthrough time while the desorption time was strongly affected by the sweep gas flowrate for the specific sorbent being evaluated in this study.

20 FOSSIL-FUELED POWER PLANTS↗

Precision geodesy using the Mark-III very-long-baseline interferometer system

Very-long-baseline interferometry (VLBI) has been used to make precise measurements of the vector separation between widely separated antennas. The system for acquiring and processing VLBI data known as Mark-III is described. Tests of the system show it to have millimeter-level accuracy on short baselines; measurements of baselines longer than a few hundred kilometers suggest that accuracy is limited by the uncertainty in the calibration of tropospheric path delay to the level of a few centimeters. VLBI experiments conducted between 1976 and 1983 have demonstrated the stability of the North American plate by showing that there is no change in the distance between eastern California and Massachusetts at the level of a few millimeters per year or greater. Experiments made from 1980 to 1984 indicate that the distance from Massachusetts to Sweden is increasing by 1.7 + or - 1 cm/year where the quoted standard deviation includes the estimated effects of systematic errors.

Clark, T. A.↗

Using Transponders on the Moon to Increase Accuracy of GPS

It has been proposed to place laser or radio transponders at suitably chosen locations on the Moon to increase the accuracy achievable using the Global Positioning System (GPS) or other satellite-based positioning system. The accuracy of GPS position measurements depends on the accuracy of determination of the ephemerides of the GPS satellites. These ephemerides are determined by means of ranging to and from Earth-based stations and consistency checks among the satellites. Unfortunately, ranging to and from Earth is subject to errors caused by atmospheric effects, notably including unpredictable variations in refraction. The proposal is based on exploitation of the fact that ranging between a GPS satellite and another object outside the atmosphere is not subject to error-inducing atmospheric effects. The Moon is such an object and is a convenient place for a ranging station. The ephemeris of the Moon is well known and, unlike a GPS satellite, the Moon is massive enough that its orbit is not measurably affected by the solar wind and solar radiation. According to the proposal, each GPS satellite would repeatedly send a short laser or radio pulse toward the Moon and the transponder(s) would respond by sending back a pulse and delay information. The GPS satellite could then compute its distance from the known position(s) of the transponder(s) on the Moon. Because the same hemisphere of the Moon faces the Earth continuously, any transponders placed there would remain continuously or nearly continuously accessible to GPS satellites, and so only a relatively small number of transponders would be needed to provide continuous coverage. Assuming that the transponders would depend on solar power, it would be desirable to use at least two transponders, placed at diametrically opposite points on the edges of the Moon disk as seen from Earth, so that all or most of the time, at least one of them would be in sunlight.

Penanen, Konstantin↗

Limitations and Feasibility of Mini X-Ray Devices in Space Environments

LIMITATIONS AND FEASIBILITY OF MINI X-RAY DEVICES IN SPACE ENVIRONMENTS As space exploration advances toward long-duration missions, reliable medical diagnostic tools become increasingly critical. The miniature x-ray (XR) technology demonstrations by the Exploration Medical Capability (ExMC) and the Exploration Medical Integrated Product Team (XMIPT) aim to assess the feasibility and utility of miniature XR devices in spaceflight. This abstract explores the limitations of current miniature XR systems, the challenges of training crew members, the potential role of clinical decision support systems (CDSS), and the feasibility of ground-based image interpretation. We also propose the integration of miniature XR into other ExMC efforts aimed at identifying the capabilities and resources needed for future exploration class missions. One of the primary challenges with miniature XR devices is the ability to achieve specific anatomical views, particularly in the confined and weightless conditions of a spacecraft. Operators may struggle to acquire diagnostic-quality images when space is limited for proper patient positioning and the volume of the imaging device. Since space radiation and detector limitations may further impact image quality, the flexibility of the operating procedures of these devices will be critical for their success in space applications. CHALLENGES IN TRAINING CREW TO OPERATE IMAGING DEVICES Training in the skills necessary to acquire diagnostic-quality scans may be a barrier for non-clinician crewmembers. The curriculum developed for crew medical officers (CMOs) will require simplification and adaptation to fit into the highly truncated pre-flight training period. Therefore, hands-on familiarization and simulation, both pre-flight and just-in-time training during missions, will be crucial to ensuring the crew can operate the devices in real-life situations. The ability to adjust acquisition parameters must be simplified or made automatic through exam selections on equipment user interfaces, and subject and operator positioning should be assisted with laser guidance and pictorial guides. POTENTIAL FOR CDSS OR ARTIFICIAL INTELLIGENCE (AI)-ASSISTED CDSS CDSS and AI-assisted CDSS offer significant promise in assisting crew members with limited medical training. These systems could provide real-time feedback on image quality and interpretation, helping to mitigate the risks of human error during space missions. Integrating procedural guidance tools, such as virtual and augmented reality, will support crewmembers in accurately positioning patients and obtaining high-quality images. However, the success of such systems will depend on the development of robust training datasets, integration with spaceflight-rated hardware, and the medical decision-making capabilities of operators. FEASIBILITY OF GROUND INTERPRETATION AND DATA TRANSMISSION Reliance on ground-based interpretation may prove difficult for acute care during exploration class-missions due to delays in transmission with increasing distance from Earth or complete communication blackout periods. In such instances where immediate interpretation for clinical intervention is required, crew must be able to interpret the images independently or utilize AI-based assistance to do so. File sizes for XR exams can also be large if numerous images are acquired and bandwidth constraints may limit data transmissions for both radiography and ultrasound exams. FUTURE WORK AND INTEGRATION INTO THE EVIDENCE LIBRARY Future work proposes integrating miniature XR devices into NASA’s Evidence Library to address medical conditions identified as significant contributors to crew morbidity and mortality. The possibility of combining miniature XR with other imaging modalities, such as ultrasound devices, is also under investigation. In conclusion, while miniature XR technology holds potential for extraterrestrial medical systems, there are significant challenges to overcome. Training, integration of AI tools, dedicated exam protocols for microgravity, and improved data transmission systems will be key to realizing the full benefits of miniature XR technology in space.

A M Nelson↗

An Analytical Approach to the Design of an Automatic Discontinuous Control System

An analytical investigation was conducted concerning the design of an attitude-stabilization system for stabilizing a vehicle experiencing negligible external moments. The system studied was an automatic discontinuous control system employing a linear switching function including effects of pure time delays, rise and decay time, and neutral zone. Equations were developed which generalize the transient and limit-cycle performance of the control system. understanding of how the physical constants of the system affect its performance, the equations enable the optimization of the system with regard to most considerations that can be expressed mathematically. Design charts are presented which enable rapid calculation of the best thrust level and switching-function coefficient for minimizing power required to stabilize the vehicle within some amplitude, minimizing attitude error, and minimizing angular-velocity error after a period of operation.

Taylor, Lawrence W., Jr.↗

TDCOSMO. I. An exploration of systematic uncertainties in the inference of $H_0$ from time-delay cosmography

Time-delay cosmography of lensed quasars has achieved 2.4% precision on the measurement of the Hubble constant, H0. As part of an ongoing effort to uncover and control systematic uncertainties, we investigate three potential sources: 1- stellar kinematics, 2- line-of-sight effects, and 3- the deflector mass model. To meet this goal in a quantitative way, we reproduced the H0LiCOW/SHARP/STRIDES (hereafter TDCOSMO) procedures on a set of real and simulated data, and we find the following. First, stellar kinematics cannot be a dominant source of error or bias since we find that a systematic change of 10% of measured velocity dispersion leads to only a 0.7% shift on H0 from the seven lenses analyzed by TDCOSMO. Second, we find no bias to arise from incorrect estimation of the line-of-sight effects. Third, we show that elliptical composite (stars + dark matter halo), power-law, and cored power-law mass profiles have the flexibility to yield a broad range in H0 values. However, the TDCOSMO procedures that model the data with both composite and power-law mass profiles are informative. If the models agree, as we observe in real systems owing to the “bulge-halo” conspiracy, H0 is recovered precisely and accurately by both models. If the two models disagree, as in the case of some pathological models illustrated here, the TDCOSMO procedure either discriminates between them through the goodness of fit, or it accounts for the discrepancy in the final error bars provided by the analysis. This conclusion is consistent with a reanalysis of six of the TDCOSMO (real) lenses: the composite model yields H0 = 74.0−1.8+1.7 km s−1 Mpc−1, while the power-law model yields 74.2−1.6+1.6 km s−1 Mpc−1. In conclusion, we find no evidence of bias or errors larger than the current statistical uncertainties reported by TDCOSMO.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation-induced genomic instability

Quantitative assessment of the heritable somatic effects of ionizing radiation exposures has relied upon the assumption that radiation-induced lesions were 'fixed' in the DNA prior to the first postirradiation mitosis. Lesion conversion was thought to occur during the initial round of DNA replication or as a consequence of error-prone enzymatic processing of lesions. The standard experimental protocols for the assessment of a variety of radiation-induced endpoints (cell death, specific locus mutations, neoplastic transformation and chromosome aberrations) evaluate these various endpoints at a single snapshot in time. In contrast with the aforementioned approaches, some studies have specifically assessed radiation effects as a function of time following exposure. Evidence has accumulated in support of the hypothesis that radiation exposure induces a persistent destabilization of the genome. This instability has been observed as a delayed expression of lethal mutations, as an enhanced rate of accumulation of non-lethal heritable alterations, and as a progressive intraclonal chromosomal heterogeneity. The genetic controls and biochemical mechanisms underlying radiation-induced genomic instability have not yet been delineated. The aim is to integrate the accumulated evidence that suggests that radiation exposure has a persistent effect on the stability of the mammalian genome.

NASA Discipline Radiation Health↗

Adaptive filtering of biodynamic stick feedthrough in manipulation tasks on board moving platforms

A novel approach to suppress the effects of biodynamic interference is presented. An adaptive noise canceling technique is employed for substracting the platform motion correlated components from the control stick output. The effects of biodynamic interference and its suppression by adaptive noise cancellation has been evaluated in a series of tracking tasks performed in a moving base simulator. Simulator motions were in pitch, roll and combined pitch and roll. Human operator performance was assessed from the mean square values of the tracking error and the control activity. The tracking error and the total stick output signal were found to increase significantly with motion and to diminish substantially with adaptive noise cancellation, thus providing a considerable improvement in tracking performance under conditions in which platform motion were present. The adaptive filter was found to cause a significant increase in the cross-over frequency and decrease in the phase margin. Moreover, the adaptive filter was found to significantly improve the human operator visual motor response. This improvement is manifested as an increased human operator gain, a smaller time delay and lower pilot workload.

Velger, M.↗

Multipath noise reduction spread spectrum signals

The concepts of early-prompt delay tracking, multipath correction of early-prompt delay tracking from correlation shape, and carrier phase multipath correction are addressed. In early-prompt delay tracking, since multipath is always delayed with respect to the direct signals, the system derives phase and pseudorange observables from earlier correlation lags. In multipath correction of early-prompt delay tracking from correlation shape, the system looks for relative variations of amplitude across the code correlation function that do not match the predicted multipath-free code cross-correlation shape. The system then uses deviations from the multipath-free shape to infer the magnitude of multipath, and to generate corrections pseudorange observables. In carrier phase multipath correction, the system looks for variations of phase among plural early and prompt lags. The system uses the measured phase variations, along with the general principle that the multipath errors are larger for later lags, to infer the presence of multipath, and to generate corrections for carrier-phase observables.

Meehan, Thomas K.↗

Robust Optimal Adaptive Control Method with Large Adaptive Gain

In the presence of large uncertainties, a control system needs to be able to adapt rapidly to regain performance. Fast adaptation is referred to the implementation of adaptive control with a large adaptive gain to reduce the tracking error rapidly. However, a large adaptive gain can lead to high-frequency oscillations which can adversely affect robustness of an adaptive control law. A new adaptive control modification is presented that can achieve robust adaptation with a large adaptive gain without incurring high-frequency oscillations as with the standard model-reference adaptive control. The modification is based on the minimization of the Y2 norm of the tracking error, which is formulated as an optimal control problem. The optimality condition is used to derive the modification using the gradient method. The optimal control modification results in a stable adaptation and allows a large adaptive gain to be used for better tracking while providing sufficient stability robustness. Simulations were conducted for a damaged generic transport aircraft with both standard adaptive control and the adaptive optimal control modification technique. The results demonstrate the effectiveness of the proposed modification in tracking a reference model while maintaining a sufficient time delay margin.

Nguyen, Nhan T.↗

Permutation codes for sources.

Source encoding techniques based on permutation codes are investigated. For a broad class of distortion measures it is shown that optimum encoding of a source permutation code is easy to instrument even for very long block lengths. Also, the nonparametric nature of permutation encoding is well suited to situations involving unknown source statistics. For the squared-error distortion measure a procedure for generating good permutation codes of a given rate and block length is described. The performance of such codes for a memoryless Gaussian source is compared both with the rate-distortion function bound and with the performance of various quantization schemes. The comparison reveals that permutation codes are asymptotically ideal for small rates and perform as well as the best entropy-coded quantizers presently known for intermediate rates. They can be made to compare favorably at high rates, too, provided the coding delay associated with extremely long block lengths is tolerable.

Berger, T.↗

Optical Performance Modeling of FUSE Telescope Mirror

We describe the Metrology Data Processor (METDAT), the Optical Surface Analysis Code (OSAC), and their application to the image evaluation of the Far Ultraviolet Spectroscopic Explorer (FUSE) mirrors. The FUSE instrument - designed and developed by the Johns Hopkins University and launched in June 1999 is an astrophysics satellite which provides high resolution spectra (lambda/Delta(lambda) = 20,000 - 25,000) in the wavelength region from 90.5 to 118.7 nm The FUSE instrument is comprised of four co-aligned, normal incidence, off-axis parabolic mirrors, four Rowland circle spectrograph channels with holographic gratings, and delay line microchannel plate detectors. The OSAC code provides a comprehensive analysis of optical system performance, including the effects of optical surface misalignments, low spatial frequency deformations described by discrete polynomial terms, mid- and high-spatial frequency deformations (surface roughness), and diffraction due to the finite size of the aperture. Both normal incidence (traditionally infrared, visible, and near ultraviolet mirror systems) and grazing incidence (x-ray mirror systems) systems can be analyzed. The code also properly accounts for reflectance losses on the mirror surfaces. Low frequency surface errors are described in OSAC by using Zernike polynomials for normal incidence mirrors and Legendre-Fourier polynomials for grazing incidence mirrors. The scatter analysis of the mirror is based on scalar scatter theory. The program accepts simple autocovariance (ACV) function models or power spectral density (PSD) models derived from mirror surface metrology data as input to the scatter calculation. The end product of the program is a user-defined pixel array containing the system Point Spread Function (PSF). The METDAT routine is used in conjunction with the OSAC program. This code reads in laboratory metrology data in a normalized format. The code then fits the data using Zernike polynomials for normal incidence systems or Legendre-Fourier polynomials for grazing incidence systems. It removes low order terms from the metrology data, calculates statistical ACV or PSD functions, and fits these data to OSAC models for the scatter analysis. In this paper we briefly describe the laboratory image testing of FUSE spare mirror performed in the near and vacuum ultraviolet at John Hopkins University and OSAC modeling of the test setup performed at NASA/GSFC. The test setup is a double-pass configuration consisting of a Hg discharge source, the FUSE off-axis parabolic mirror under test, an autocollimating flat mirror, and a tomographic imaging detector. Two additional, small fold flats are used in the optical train to accommodate the light source and the detector. The modeling is based on Zernike fitting and PSD analysis of surface metrology data measured by both the mirror vendor (Tinsley) and JHU. The results of our models agree well with the laboratory imaging data, thus validating our theoretical model. Finally, we predict the imaging performance of FUSE mirrors in their flight configuration at far-ultraviolet wavelengths.

Saha, Timo T.↗

Precise timing correlation in telemetry recording and processing systems

Independent PCM telemetry data signals received from missiles must be correlated to within + or - 100 microseconds for comparison with radar data. Tests have been conducted to determine RF antenna receiving system delays; delays associated with wideband analog tape recorders used in the recording, dubbing and repdocuing processes; and uncertainties associated with computer processed time tag data. Several methods used in the recording of timing are evaluated. Through the application of a special time tagging technique, the cumulative timing bias from all sources is determined and the bias removed from final data. Conclusions show that relative time differences in receiving, recording, playback and processing of two telemetry links can be accomplished with a + or - 4 microseconds accuracy. In addition, the absolute time tag error (with respect to UTC) can be reduced to less than 15 microseconds. This investigation is believed to be the first attempt to identify the individual error contributions within the telemetry system and to describe the methods of error reduction within the telemetry system and to describe the methods of error reduction and correction.

Pickett, R. B.↗

Total ionospheric electron content calibration using SERIES GPS satellite data

The current status of the Deep Space Network advanced systems research into ionospheric calibration techniques, based on Global Positioning System (GPS) data is described. A GPS-based calibration system is planned to replace the currently used Faraday rotation method by 1989. The SERIES receiver system determines the differential group delay of signals transmitted at two different carrier frequencies. This differential delay includes an ionospheric component and a GPS transmitter offset. The transmitter offsets are different for each GPS satellite. Tests were conducted to assess the effect of the offsets on the ionospheric calibration accuracy. From the obtained data, the total electron content and GPS transmitter offsets are calculated by a least squares estimation method employing a local model of total ionospheric electron content. The end product is an estimation of the total ionospheric content for an arbitrary line-of-sight direction. For the presented polynomial fitting technique, the systematic error due to mismodeling is estimated to be approximately 6 x 10 to the 16th power el/sq m, while the formal error is approximately 2 x 10 to the 16th power el/sq m. The final goal is an error of 3 x 10 to the 16th power el/sq m (approximately 0.7 ns at 2.3 GHz).

Lanyi, G.↗

Hydrogen oxidation mechanism with applications to (1) the chaperon efficiency of carbon dioxide and (2) vitiated air testing

Ignition delay times for the hydrogen/oxygen/carbon dioxide/argon system were obtained behind reflected shock waves. A detailed kinetic mechanism modeled the experimental hydrogen/oxygen data, Skinner and Ringrose's high-pressure data, and Slack and Grillo's hydrogen/air data. A carbon dioxide chaperon efficiency of 7.0 +/- 0.2 was determined. The reaction pathway H2O yields H2O2 yields OH yields H was required to model the high-pressure data. It is suggested that some of the lowest temperature data points (1.0 and 0.5 atm) for Slack and Grillo's hydrogen/air experiments are in error. It was found that the technique of simplifying a detailed kinetic mechanism for a limited range of experimental data may render the model useless for other test conditions.

Brabbs, Theodore A.↗

Quantum Vibronic Effects on the Electronic Properties of Molecular Crystals

We present a study of molecular crystals, focused on the effect of nuclear quantum motion and anharmonicity on their electronic properties. We consider a system composed of relatively rigid molecules, a diamondoid crystal, and one composed of floppier molecules, NAI-DMAC, a thermally activated delayed fluorescence compound. We compute fundamental electronic gaps at the density functional theory (DFT) level of theory, with the Perdew–Burke–Erzenhof (PBE) and strongly constrained and approximately normed (SCAN) functionals, by coupling first-principles molecular dynamics with a nuclear quantum thermostat. We find a sizable zero-point renormalization (ZPR) of the band gaps, which is much larger in the case of diamondoids (0.6 eV) than for NAI-DMAC (0.22 eV). We show that the frozen phonon (FP) approximation, which neglects intermolecular anharmonic effects, leads to a large error (~50%) in the calculation of the band gap ZPR. Instead, when using a stochastic method, we obtain results in good agreement with those of our quantum simulations for the diamondoid crystal. However, the agreement is worse for NAI-DMAC where intramolecular anharmonicities contribute to the ZPR. Our results highlight the importance of accurately including nuclear and anharmonic quantum effects to predict the electronic properties of molecular crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TOPEX microwave radiometer system calibration - Refining the SMMR heritage

A modified version of the Scanning multichannel Microwave Radiometer (SMMR) will be used for wet tropospheric path-delay corrections to the TOPEX/POSEIDON radar altimeter measurements. A number of the sources of calibration problems encountered by SMMR onboard the Seasat and Nimbus-7 platforms have been identified, and appropriate corrections have been attempted. Calibration hardware corrections include a more representative modeling of the microwave losses and reflections, and a reduction in the thermal gradients expected across this hardware through the use of radomes and sun shades and the choice of pertinent orbit parameters. Antenna calibration corrections include a postlaunch fine tuning of the antenna pattern correction algorithm to accommodate small errors in the prelaunch antenna pattern measurements. This is accomplished by overpasses of ground-based, upward-looking water vapor radiometers. An absolute calibration accuracy of 1.0 K or less is anticipated.

Ruf, Christopher S.↗

Truncated ARQ Statistical Link Analysis for Dynamic Links

The future deep space links are migrating towards higher frequency bands such as Ka band and optical. These links are susceptible to non Gaussian and non linear effects such as atmospheric turbulence, scintillation, antenna mis-pointing, jitter, etc. These dynamic links thus will experience various degrees of fading loss, and some of these link disruptions cannot be effectively mitigated by forward error correction coding and/or interleaving. One effective way to ensure reliable communication is by using Automatic Repeat Request (ARQ) protocol, where the receiver acknowledges to the transmitter whether or not a data unit is successfully received. If a data unit is not successfully received (such as after a pre-set time-out), the transmitter would then re-transmit the lost data unit to the receiver. In a previous paper, we derived a statistical link analysis method of finding the optimal operating Signal-to-Noise Ratio (SNR) and estimating the latency of an ARQ scheme. In a more recent paper, we demonstrated the above method using the SNR distribution constructed from the Ka-band (32 GHz) flight data. To simplify the discussion, we considered the academic approach that the ARQ scheme allows for an infinite number of retransmissions. In this paper, we consider the more practical case of a truncated ARQ scheme, where there is a limit on the number of retransmissions. We derive the error probability, the optimal SNR setting, and the latency statistics of the correctly received frames of the truncated ARQ schemes. We first discuss the truncated ARQ link analysis principles using the Gaussian assumption for SNR distribution with a large variance. Next, we demonstrate the statistical truncated ARQ link analysis using the SNR distribution constructed from the Ka-band flight data. The results in this paper can be applied in the design of reliable communication systems such as the Consultative Committee for Space Data System (CCSDS) File Transfer Protocol (CFTP) and the Delay Tolerant Network (DTN).

Morabito, David↗