Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cost data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

ARETE: Accurate Error Assessment via Machine Learning-Guided Dynamic-Timing Analysis

Nanometer circuits are increasingly prone to timing errors, escalating the need for fault injection frameworks to accurately evaluate their impact on applications. Here in this paper, we propose ARETE, a novel cross-layer, fault-injection framework that combines dynamic-binary instrumentation with machine learning-guided dynamic-timing analysis. ARETE enables accurate fault-injection into any application by estimating the location of the injecting errors via dynamic-timing analysis. To accelerate fault-injection, we develop a novel, data-aware, machine learning-based mechanism that dynamically pre-selects the error-prone instructions and limits the application of the costly dynamic-timing analysis only to them. To evaluate ARETE's accuracy, our fully automated toolflow is configured to support fault-injection based on detailed post-layout gate-level simulations as well as via existing workload-agnostic error models. Our results for various workloads, including an autonomous-driving library, show that the location and time of injected errors performed by ARETE, is 89.9% consistent with fault-injection based on full gate-level simulation. On average, ARETE executes 84.6x faster than gate-level simulation and at a cost of 3.4% loss in the program output quality estimation. When compared to the existing statistical fault-injection tools that are based on workload-agnostic error models, ARETE improves the accuracy of fault-injection rate and output quality estimation by 143.9% and 40.4% on average, respectively.

97 MATHEMATICS AND COMPUTING↗

Enabling Staged Pressurized Oxy-Combustion: Improving Flexibility and Performance at Reduced Cost

Introduction: The staged pressurized oxy-combustion (SPOC) process, developed by Washington University in St. Louis (WUSTL), is an oxy-combustion carbon capture technology that employs a steam power cycle to generate electricity. As with atmospheric-pressure oxy-combustion processes, carbon dioxide (CO 2 ) capture rates of 90% or higher can be achieved. The staged-combustion approach of the SPOC process, when operated at elevated gas pressure, allows for near elimination of flue gas recycle (FGR) and leads to significant improvements in efficiency and reduced costs. The primary goal of this project was to investigate the potential for SPOC for flexible operation beyond the capabilities of conventional coal-fired power plants, particularly those employing carbon capture and storage (CCS). Oxy-combustion differs from conventional coal combustion in that the combustion of coal is carried out using oxygen as opposed to air. The resultant flue gas is a mixture of primarily CO 2 and water, greatly simplifying CO 2 capture. As SPOC does the oxy-combustion process under pressure, it is higher efficiency and lower cost than atmospheric oxy-combustion. The project was led by the Electric Power Research Institute, Inc., with the assistance of WUSTL, Doosan Babcock (DBL – boiler plant original equipment manufacturer), and Air Liquide (AL – air separation experts). The specific objectives of the project were to: (1) Evaluate the SPOC concept and develop a risk-based approach to the heating surface layout ensuring that performance (gas and steam side), manufacturing, transportation, and plant erection considerations were fully accounted for in the system design. (2) Improve the technology to ensure its performance and cost potential are substantially better than today’s baseline pulverized coal power plant with post-combustion capture (PCC) or atmospheric oxy-combustion, and show progress toward performance commensurate with projected commercial operation, including 90% or more CO 2 capture. (3) Address critical technology gaps and improving overall system performance for the technology. (4) Perform combustion tests at scale under commensurate pressure to the commercial operating system validate combustor and advance the SPOC combustion modeling tools that will facilitate full-scale design. Combustion Testing: Testing was initially carried out at atmospheric pressure with methane to ensure that all systems were correctly operating. Following this, the testing then proceeded to moderate pressure operation at 4 bara, where different stoichiometric conditions were used across an extended heat input range, showing that a stable flame could be maintained. Testing then proceeded at 10 and 15 bara where it was shown that the ignition system needed to be replaced at these operating conditions. When testing recommenced, a similar stable flame shape was achieved, without any methane support, and the full 100 kWth coal oxy-combustion was demonstrated. Heat flux measurements showed 400 kW/m 2 (0.126 MMBtu/hr-ft 2 ) from the flame, within the 450 kW/m 2 (0.142 MMBtu/hr-ft 2 ) preferred limit defined by DBL for the full-scale design case. Carbon monoxide and carbon-in-ash measurements showed that complete combustion was possible with ultra-low excess oxygen at 1 vol % in the product flue gas. This allowed the full-scale models to be calculated based on this level of excess oxygen, improving the performance of the system as lower feed oxygen is produced in the air separation unit (ASU), saving auxiliary power. Full-Scale Design: The full-scale design is sized to deliver 550 MWe net electrical power output to allow direct comparison with the National Energy Technology Laboratory (NETL) baseline cases using the same Montana Powder River Basin (PRB) fuel. The cases used for direct comparison are: Case S12A (supercritical [SC] coal without CO 2 capture), Case S12B (SC coal with PCC at 90% CO 2 capture, and Case S12F (atmospheric oxy-combustion SC coal with 90% CO 2 capture). The SPOC stages were configured to be identical arrangements, allowing for a more straightforward design, construction, and control strategy. Each stage consists of two PVs, the first being the combustor PV module and the second being the convective PV module. The combustor module is the tallest vessel, with local coal feeding equipment and the burner FGR and oxygen plenums at the top and ash management at the bottom. The combustor module is effectively an open cross section with membrane tubes around the circumference – this unobstructed slender profile ensures that the relatively slower burnout mechanism needed for the low-speed turbulent mixing burner can proceed unimpeded and that molten ash will not attach to any surfaces at an angle to the predominant flue gas flow. The steam turbine used in the SPOC design is essentially the same unit utilized in the atmospheric oxy-combustion case except the degree of heat recovery possible allows the low-pressure (LP) feedwater heater train to be eliminated. This is a result of being able to capture the latent heat of evaporation of the moisture produced in the combustion (normally lost to the stack). The SPOC system outperforms the NETL atmospheric oxy-combustion baseline case by 3.3% points and the PCC case by 7.5% points. This performance increase is mainly a result of the improved heat recovery possible from the product flue gas and from the reduced auxiliary power consumption from the ASU and the CO 2 compression and purification unit over the atmospheric equivalent. The combined improvement in boiler efficiency and reduction in the steam turbine heat rate resulted in a net improvement in the overall plant efficiency by 0.61%, to 35.6% on a HHV basis. This relatively small improvement in plant efficiency between sub-bituminous and bituminous coals shows the value of useful moisture latent heat recovery offered by the SPOC system when using low rank fuels. Flexibility and Turndown: The SPOC system has inherent high turndown capabilities because of a demonstrated high range of combustion stability and the ability to bypass stages, thereby reducing steam generation rates proportionally without altering firing rates in operating stages. ASU units do not generally offer significant turndown opportunities as they are limited by the performance of the compression plant. The baseline SPOC design has a 2-train ASU configuration, needed to be able to meet the 10,500 tonnes per day duty, that can deliver efficient turndown points between 85–100% load with both trains operating, and at 45–50% load with a single train operating. Outside these operating points, the flexibility and efficiency are limited and may be uncompetitive at loads below 45% as the ASU systems are unable to turndown beyond 85% for the base case and 70% for the flexible case. The ASU cold box for the flexible case was designed to operate at loads between 40-100%, below this operating range the purity of the produced oxygen cannot be guaranteed, resulting in additional load for the CPU equipment. The additional power consumption of these cases yields an uneconomic operating condition with poor efficiency when operating at low loads such as 25% and 12%. To address this flexibility constraint, AL evaluated how the ASU configuration could be altered to deliver efficient oxygen supply over the load range. This involved integrating the compressor duties across both ASU trains into a shared duty arrangement with multiple compressors, strategically sized to deliver the duty required across all load ranges between 40–100% by enabling different combinations of the main air compressors and the booster air compressors. The oxygen purity cannot be guaranteed below 40% load for each train – the power consumption at 25% and 12% loads were estimated based on the multi-compressor configuration at maximum turndown as these load cases were not considered in the flexible ASU design. With a different cold box configuration, i.e. number of trains, the entire load range could be delivered within oxygen purity specifications. Although there is a small efficiency reduction at full load, there are significant improvements in overall plant performance during low-load operation. The exact ASU configuration needed will therefore be dependent on the expected operating profile of the unit. Economic Analysis: Cost estimates for the baseline and the flexible cases were developed using NETL baseline case data for common BOP items and an Association for the Advancement of Cost Engineering International Class 5 (conceptual/screening study) assessment of key components unique to the SPOC system. The capital, operating, and maintenance costs were assessed along with the first-year power cost, levelized cost of electricity, and CO 2 captured and avoided cost for the SPOC cases were compared against the relevant NETL baseline cases in January 2019 dollars. Both SPOC cases achieve a lower cost that the alternative NETL baseline cases (with the flexible SPOC case being slightly higher than the baseline SPOC case due to the compounded impact of higher capital costs and lower efficiency at full load). The SPOC cases deliver a lower cost of CO 2 avoided than the NETL baseline cases due to greater efficiency in generating low-carbon power. However, the cost of CO 2 captured is higher because the higher efficiency of the SPOC process generates less CO 2 , hence less needs to be captured, resulting in a high capital cost being shared over a reduced CO 2 quantity. The flexible ASU adds 1.6% overall to the plant cost in comparison to the baseline case, but the efficiency improvements at loads below 50% are significant. Subsequently, depending on the plant load-profile expectation, the flexible ASU would be beneficial if the plant spends a significant portion of its operating life below 50% load. This kind of operating profile is likely to be required for all fossil plants when more renewable electricity generators are installed on the local grid, particularly solar power that can be predicted ahead of time, allowing for appropriate pricing signals to be incorporated into the diurnal cycle. R&D Recommendations: SPOC, while a promising technology, is a relatively recent concept and, as such, operability issues of combustor design and steam-side integration for such systems at a scale relevant to commercial deployment have not been evaluated. WUSTL has conducted extensive small pilot-scale (100 kWth) research to understand and advance pressurized oxy-combustion processes, including investigation of combustion and flame characteristics, radiative heat flux, burner operability, turn down, char burnout, ash characteristics, water-wash column operation, etc. for pressurized oxy-combustion systems. Nonetheless, at this stage in the development of the SPOC process, what is needed is a large-scale pilot plant that can serve to study pressurized oxy-combustion systems and components at a scale commensurate with the maturity of the technology. A scale of 10 MWth, which includes steam-side integration and two stages would yield essential information with respect to heat transfer characteristics both in the radiative and convective sections of the pressure vessels, and the ability to operate the fuel staging process. In addition, while modeling results indicate that combustion and flame characteristics improve with scale, direct studies of the combustor at this scale will ensure that the models can be relied upon for scale up to commercial scale. Furthermore, a detailed analysis must be performed to understand the scaling aspects of key components and systems.

20 FOSSIL-FUELED POWER PLANTS↗

A sophisticated, multi-channel data acquisition and processing system for high frequency noise research

A sophisticated, multi-channel computerized data acquisition and processing system was developed at the NASA LeRC for use in noise experiments. This technology, which is available for transfer to industry, provides a convenient, cost-effective alternative to analog tape recording for high frequency acoustic measurements. This system provides 32-channel acquisition of microphone signals with an analysis bandwidth up to 100 kHz per channel. Cost was minimized through the use of off-the-shelf components. Requirements to allow for future expansion were met by choosing equipment which adheres to established industry standards for hardware and software. Data processing capabilities include narrow band and 1/3 octave spectral analysis, compensation for microphone frequency response/directivity, and correction of acoustic data to standard day conditions. The system was used successfully in a major wind tunnel test program at NASA LeRC to acquire and analyze jet noise data in support of the High Speed Civil Transport (HSCT) program.

Hall, David G.↗

An Analysis of U.S. Civil Rotorcraft Accidents by Cost and Injury (1990-1996)

A study of rotorcraft accidents was conducted to identify safety issues and research areas that might lead to a reduction in rotorcraft accidents and fatalities. The primary source of data was summaries of National Transportation Safety Board (NTSB) accident reports. From 1990 to 1996, the NTSB documented 1396 civil rotorcraft accidents in the United States in which 491 people were killed. The rotorcraft data were compared to airline and general aviation data to determine the relative safety of rotorcraft compared to other segments of the aviation industry. In depth analysis of the rotorcraft data addressed demographics, mission, and operational factors. Rotorcraft were found to have an accident rate about ten times that of commercial airliners and about the same as that of general aviation. The likelihood that an accident would be fatal was about equal for all three classes of operation. The most dramatic division in rotorcraft accidents is between flights flown by private pilots versus professional pilots. Private pilots, flying low cost aircraft in benign environments, have accidents that are due, in large part, to their own errors. Professional pilots, in contrast, are more likely to have accidents that are a result of exacting missions or use of specialized equipment. For both groups judgement error is more likely to lead to a fatal accident than are other types of causes. Several approaches to improving the rotorcraft accident rate are recommended. These mostly address improvement in the training of new pilots and improving the safety awareness of private pilots.

Iseler, Laura↗

Development of a Multivariable Parametric Cost Analysis for Space-Based Telescopes

Over the past 400 years, the telescope has proven to be a valuable tool in helping humankind understand the Universe around us. The images and data produced by telescopes have revolutionized planetary, solar, stellar, and galactic astronomy and have inspired a wide range of people, from the child who dreams about the images seen on NASA websites to the most highly trained scientist. Like all scientific endeavors, astronomical research must operate within the constraints imposed by budget limitations. Hence the importance of understanding cost: to find the balance between the dreams of scientists and the restrictions of the available budget. By logically analyzing the data we have collected for over thirty different telescopes from more than 200 different sources, statistical methods, such as plotting regressions and residuals, can be used to determine what drives the cost of telescopes to build and use a cost model for space-based telescopes. Previous cost models have focused their attention on ground-based telescopes due to limited data for space telescopes and the larger number and longer history of ground-based astronomy. Due to the increased availability of cost data from recent space-telescope construction, we have been able to produce and begin testing a comprehensive cost model for space telescopes, with guidance from the cost models for ground-based telescopes. By separating the variables that effect cost such as diameter, mass, wavelength, density, data rate, and number of instruments, we advance the goal to better understand the cost drivers of space telescopes.. The use of sophisticated mathematical techniques to improve the accuracy of cost models has the potential to help society make informed decisions about proposed scientific projects. An improved knowledge of cost will allow scientists to get the maximum value returned for the money given and create a harmony between the visions of scientists and the reality of a budget.

Dollinger, Courtnay↗

Life Cycle Inventories and Data Gap Analysis for Rare Earth Elements: Neodymium and Dysprosium from Mining to Magnets

The United States demand for Neodymium-Iron-Boron (NdFeB) magnets, produced from rare earth elements (REEs) such as (Nd) and Dysprosium (Dy), far exceeds its nascent domestic production capacity, rendering it reliant on vulnerable global supply chains dominated by China. To guide research and development investments in securing U.S. REE supply, defensible benchmark metrics across environmental, economic, and social dimensions are needed. In this study, we built globally-representative, process-based cradle-to-cradle life cycle inventories for Nd and Dy in NdFeB magnets lifecycles, encompassing primary material acquisition, beneficiation, smelting and refining, metal processing, specialty alloy and chemical transformation, subcomponent manufacturing, consumer application (use phase) and end-of-life management. We carried out detailed literature review, and applied process engineering principles to build industry-representative upscaled life cycle inventories for both metals. We used these models to conduct bottom-up literature review and gap analysis on existing literature, compilation of data sources for each life cycle stage (and transformations where necessary), and a preliminary technoeconomic analysis (TEA)/life cycle costing analysis (LCCA). Findings from this work emphasize the need for metal specific, representative REE LCIs to establish robust benchmarks for advancing sustainable REE technologies and guiding R&D in REE supply chains.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Methods for Analysis of Outdoor Performance Data (Presentation)

The ability to accurately predict power delivery over the course of time is of vital importance to the growth of the photovoltaic (PV) industry. Two key cost drivers are the efficiency with which sunlight is converted to power and secondly how this relationship develops over time. The accurate knowledge of power decline over time, also known as degradation rates, is essential and important to allstakeholders--utility companies, integrators, investors, and scientists alike. Different methods to determine degradation rates and discrete versus continuous data are presented, and some general best practice methods are outlined. In addition, historical degradation rates and some preliminary analysis with respect to climate are given.

14 SOLAR ENERGY↗

Applying Technology Ranking and Systems Engineering in Advanced Life Support

According to the Advanced Life Support (ALS) Program Plan, the Systems Modeling and Analysis Project (SMAP) has two important tasks: 1) prioritizing investments in ALS Research and Technology Development (R&TD), and 2) guiding the evolution of ALS systems. Investments could be prioritized simply by independently ranking different technologies, but we should also consider a technology's impact on system design. Guiding future ALS systems will require SMAP to consider many aspects of systems engineering. R&TD investments can be prioritized using familiar methods for ranking technology. The first step is gathering data on technology performance, safety, readiness level, and cost. Then the technologies are ranked using metrics or by decision analysis using net present economic value. The R&TD portfolio can be optimized to provide the maximum expected payoff in the face of uncertain future events. But more is needed. The optimum ALS system can not be designed simply by selecting the best technology for each predefined subsystem. Incorporating a new technology, such as food plants, can change the specifications of other subsystems, such as air regeneration. Systems must be designed top-down starting from system objectives, not bottom-up from selected technologies. The familiar top-down systems engineering process includes defining mission objectives, mission design, system specification, technology analysis, preliminary design, and detail design. Technology selection is only one part of systems analysis and engineering, and it is strongly related to the subsystem definitions. ALS systems should be designed using top-down systems engineering. R&TD technology selection should consider how the technology affects ALS system design. Technology ranking is useful but it is only a small part of systems engineering.

Jones, Harry↗

ANSI/ASHRAE/IES Standard 90.1-2010 Final Determination Quantitative Analysis

The U.S. Department of Energy (DOE) conducted a final quantitative analysis to assess whether buildings constructed according to the requirements of the American National Standards Institute (ANSI)/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)/Illuminating Engineering Society of North America (IESNA) Standard 90.1-2010 (ASHRAE Standard 90.1-2010, Standard 90.1-2010, or 2010 edition) would result in energy savings compared with buildings constructed to ANSI/ASHRAE/IESNA Standard 90.1-2007(ASHRAE Standard 90.1-2007, Standard 90.1-2007, or 2007 edition). The final analysis considered each of the 109 addenda to ASHRAE Standard 90.1-2007 that were included in ASHRAE Standard 90.1-2010. All 109 addenda processed by ASHRAE in the creation of Standard 90.1-2010 from Standard 90.1-2007 were reviewed by DOE, and their combined impact on a suite of 16 building prototype models in 15 ASHRAE climate zones was considered. Most addenda were deemed to have little quantifiable impact on building efficiency for the purpose of DOE's final determination. However, out of the 109 addenda, 34 were preliminarily determined to have a measureable and quantifiable impact. A suite of 240 computer energy simulations for building prototypes complying with ASHRAE 90.1-2007 was developed. These prototypes were then modified in accordance with these 34 addenda to create a second suite of corresponding building simulations reflecting the same buildings compliant with Standard 90.1-2010. The building simulations were conducted using the DOE EnergyPlus building simulation software. The resulting energy use from the complete suite of 480 simulation runs was then converted to energy use intensity (EUI, or energy use per unit floor area) metrics (Site EUI, Primary EUI, and energy cost intensity [ECI]) results for each simulation. For each edition of the standard, these EUIs were then aggregated to a national basis for each prototype using weighting factors based on construction floor area developed for each of the 15 U.S. climate zones using commercial construction data. When compared, the resulting weighted EUIs indicated that each of the 16 building prototypes used less energy under Standard 90.1-2010 than under Standard 90.1-2007 on a national basis when considering site energy, primary energy, or energy cost. The EUIs were also aggregated across building types to a national commercial building basis using the same weighting data. On a national basis, the final quantitative analysis estimated a floor-space-weighted national average reduction in new building energy consumption of 18.2 percent for source energy and 18.5 percent when considering site energy. An 18.2 percent savings in energy cost, based on national average commercial energy costs for electricity and natural gas, was also estimated.

03 NATURAL GAS↗

ANSI/ASHRAE/IES Standard 90.1-2010 Final Determination Quantitative Analysis

The U.S. Department of Energy (DOE) conducted a final quantitative analysis to assess whether buildings constructed according to the requirements of the American National Standards Institute (ANSI)/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)/Illuminating Engineering Society (IES) Standard 90.1-2010 (ASHRAE Standard 90.1-2010, Standard 90.1-2010, or 2010 edition) would result in energy savings compared with buildings constructed to ANSI/ASHRAE/Illuminating Engineering Society of North America (IESNA) Standard 90.1- 2007(ASHRAE Standard 90.1-2007, Standard 90.1-2007, or 2007 edition). The final analysis considered each of the 109 addenda to ASHRAE Standard 90.1-2007 that were included in ASHRAE Standard 90.1- 2010. All 109 addenda processed by ASHRAE in the creation of Standard 90.1-2010 from Standard 90.1-2007 were reviewed by DOE, and their combined impact on a suite of 16 building prototype models in 15 ASHRAE climate zones was considered. Most addenda were deemed to have little quantifiable impact on building efficiency for the purpose of DOE’s final determination. However, out of the 109 addenda, 34 were preliminarily determined to have a measureable and quantifiable impact. A suite of 240 computer energy simulations for building prototypes complying with ASHRAE 90.1- 2007 was developed. These prototypes were then modified in accordance with these 34 addenda to create a second suite of corresponding building simulations reflecting the same buildings compliant with Standard 90.1-2010. The building simulations were conducted using the DOE EnergyPlus building simulation software. The resulting energy use from the complete suite of 480 simulation runs was then converted to energy use intensity (EUI, or energy use per unit floor area) metrics (Site EUI, Primary EUI, and energy cost intensity [ECI]) results for each simulation. For each edition of the standard, these EUIs were then aggregated to a national basis for each prototype using weighting factors based on construction floor area developed for each of the 15 U.S. climate zones using commercial construction data. When compared, the resulting weighted EUIs indicated that each of the 16 building prototypes used less energy under Standard 90.1-2010 than under Standard 90.1-2007 on a national basis when considering site energy, primary energy, or energy cost. The EUIs were also aggregated across building types to a national commercial building basis using the same weighting data. On a national basis, the final quantitative analysis estimated a floor-space-weighted national average reduction in new building energy consumption of 18.2 percent for source energy and 18.5 percent when considering site energy. An 18.2 percent savings in energy cost, based on national average commercial energy costs for electricity and natural gas, was also estimated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pumped Storage Hydropower Potential and Opportunities

Pumped storage hydropower (PSH) is a flexible energy storage technology with the potential to improve grid reliability, resiliency, and stability in the electric grid of the future. NREL has developed a range of data and tools to help understand opportunities for new PSH deployment, including nationwide resource assessment data, a bottom-up component-level cost model, and a lifecycle greenhouse gas emissions calculator. These datasets can then be used to inform grid planning models, analysis, and decision making to understand the role PSH can play in the power sector.

cost↗

Field Validation of Cloud Properties Sensor Field Campaign Report

The purpose of this campaign is to deploy Aerodyne Research Inc.’s extended wavelength cloud optical properties sensor (TWST-EN) in an operationally relevant environment with co-located, validated sensors. The Atmospheric Radiation Measurement (ARM) user facility’s Southern Great Plains (SGP) observatory is ideal for this deployment because of the variety of operational sensors that can measure some of the same cloud properties using different modalities. While cloud property sensors have long existed, they tend to be costly to produce and maintain. Our sensor measures absolute spectral radiance in the two bands and will retrieve cloud optical depth (COD), droplet effective radius, and thermodynamic phase. Our prototype is built predominantly from off-the-shelf components and uses uncooled spectrometers. A lower-cost, easy-to-use sensor such as this could allow deployment at many more sites for greater spatial coverage. Analysis and retrieval algorithm development using the data from this deployment has been a central technical objective of our U.S. Department of Energy Small Business Innovative Research (SBIR) Phase 2 contract (DE-SC0020473: Low-Cost Shortwave Spectroradiometer for Retrieval of Cloud Properties).

54 ENVIRONMENTAL SCIENCES↗

Cost effectiveness of conventional versus LANDSAT use data for hydrologic modeling

Six case studies were analyzed to investigate the cost effectiveness of using land use data obtained from LANDSAT as opposed to conventionally obtained data. A procedure was developed to determine the relative effectiveness of the two alternative means of acquiring data for hydrological modelling. The cost of conventionally acquired data ranged between $3,000 and $16,000 for the six test basins. Information based on LANDSAT imagery cost between $2,000 and $5,000. Results of the effectiveness analysis shows the differences between the two methods are insignificant. From the cost comparison and the act that each method, conventional and LANDSAT, is shown to be equally effective in developing land use data for hydrologic studies, the cost effectiveness of the conventional or LANDSAT method is found to be a function of basin size for the six test watersheds analyzed. The LANDSAT approach is cost effective for areas containing more than 10 square miles.

George, T. S.↗

Automated Performance Characterization of DSN System Frequency Stability Using Spacecraft Tracking Data

This software provides an automated capability to measure and qualify the frequency stability performance of the Deep Space Network (DSN) ground system, using daily spacecraft tracking data. The results help to verify if the DSN performance is meeting its specification, therefore ensuring commitments to flight missions; in particular, the radio science investigations. The rich set of data also helps the DSN Operations and Maintenance team to identify the trends and patterns, allowing them to identify the antennas of lower performance and implement corrective action in a timely manner. Unlike the traditional approach where the performance can only be obtained from special calibration sessions that are both time-consuming and require manual setup, the new method taps into the daily spacecraft tracking data. This new approach significantly increases the amount of data available for analysis, roughly by two orders of magnitude, making it possible to conduct trend analysis with good confidence. The software is built with automation in mind for end-to-end processing. From the inputs gathering to computation analysis and later data visualization of the results, all steps are done automatically, making the data production at near zero cost. This allows the limited engineering resource to focus on high-level assessment and to follow up with the exceptions/deviations. To make it possible to process the continual stream of daily incoming data without much effort, and to understand the results quickly, the processing needs to be automated and the data summarized at a high level. Special attention needs to be given to data gathering, input validation, handling anomalous conditions, computation, and presenting the results in a visual form that makes it easy to spot items of exception/deviation so that further analysis can be directed and corrective actions followed.

Pham, Timothy T.↗

Cost analysis of atmosphere monitoring systems

A methodology was developed to predict realistic relative cost of life support systems and to define areas of major cost impacts in the development cycle. Emphasis was given to tailoring the cost data for usage by program planners and designers. Cost estimates can be completed using the developed equations for varying degrees of equipment refinement, as well as comparative costs between different functional methods. Cost analysis of two leading atmosphere monitoring systems, namely the mass spectrometer and the gas chromatograph, is discussed. A summary of the approach used in developing the cost estimating techniques is presented. Included are the cost estimating techniques, the development of cost estimating relationships, and the atmosphere monitoring system cost estimates.

Yakut, M. M.↗

TransPlatformer

We propose TransPlatformer for translating toxicogenomics from one platform to another. Transcriptomic profiling has evolved through multiple generations of technology, from microarrays (e.g., Affymetrix, CodeLink) to more recent high-throughput sequencing and targeted panels such as S1500+. Microarrays, which dominated gene expression studies in the early 2000s, provided affordable and high-throughput transcript quantification but suffered from cross-hybridization issues and limited dynamic range . RNA-Seq, introduced in the late 2000s, revolutionized transcriptomics by enabling unbiased and comprehensive gene expression analysis, albeit at higher costs and computational demands . Despite advances, many studies rely on historical microarray data, necessitating the translation of legacy data into modern platforms to ensure continuity and comparability. This translation is complicated by factors such as platform-specific probe design, differences in transcript coverage, and batch effects . Existing methods for cross-platform mapping include statistical normalization, machine learning models, and biological anchoring approaches. The ability to translate transcriptomic data between platforms has broad implications, including enhanced meta-analyses, improved toxicological modeling, and better integration of historical datasets with contemporary research. TransPlatformer seeks to contribute to this effort by evaluating translation methodologies and proposing novel strategies to improve cross-platform gene expression harmonization. In this repository there are code examples for TransPlatformer implementation

Cong, Guojing↗

Fully integrated safeguards and security for reprocessing plant monitoring.

Nuclear fuel reprocessing plants contain a wealth of plant monitoring data including material measurements, process monitoring, administrative procedures, and physical protection elements. Future facilities are moving in the direction of highly-integrated plant monitoring systems that make efficient use of the plant data to improve monitoring and reduce costs. The Separations and Safeguards Performance Model (SSPM) is an analysis tool that is used for modeling advanced monitoring systems and to determine system response under diversion scenarios. This report both describes the architecture for such a future monitoring system and present results under various diversion scenarios. Improvements made in the past year include the development of statistical tests for detecting material loss, the integration of material balance alarms to improve physical protection, and the integration of administrative procedures. The SSPM has been used to demonstrate how advanced instrumentation (as developed in the Material Protection, Accounting, and Control Technologies campaign) can benefit the overall safeguards system as well as how all instrumentation is tied into the physical protection system. This concept has the potential to greatly improve the probability of detection for both abrupt and protracted diversion of nuclear material.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrated FHR technology development: Tritium management, materials testing, salt chemistry control, thermal hydraulics and neutronics, associated benchmarking and commercial basis

This report summarizes the results of a 3-year Integrated Research Project (IRP) sponsored by the U.S. Department of Energy to address major technical challenges in the development of the Fluoride-salt-cooled High-temperature Reactor (FHR). The IRP universities included the Massachusetts Institute of Technology (MIT), the University of California at Berkeley (UCB), the University of Wisconsin (UW), and the University of New Mexico (UNM). The FHR is a new reactor concept less than 20 years old that combines (1) a clean fluoride salt coolant, (2) the graphite-matrix coated-particle fuel originally developed for High- Temperature Gas-Cooled Reactors and (3) passive decay heat removal systems from sodium fast reactors. The base-line design is a pebble-bed FHR that delivers heat between 600 to 700°C with a 7 Li 2 BeF 4 (flibe) salt coolant to the power cycle or industrial users. The Executive Summary describes what was accomplished and summarizes major conclusions. The main report contains stand-alone sections in each major area of work. Highlights are summarized below. Tritium. The coolant salt produces tritium necessitating understanding and control of tritium. Experimental work included measuring hydrogen uptake on carbon, tritium uptake during irradiation of graphite in 700°C salt and the permeability of tritium through metals with and without coatings. An FHR systems model was developed to predict tritium behavior and enable design of tritium control systems. The leading candidate for tritium removal from the flibe salt is carbon bed outside the reactor core. Thermal hydraulics and Neutronics. A 10-meter high FHR integral effects test facility, using Dowtherm A®, has been built and used to simulate the integral response of a representative FHR to improve understanding of FHR thermal hydraulics and validate thermal hydraulics codes used for the FHR. Neutronic analysis included code-to-code benchmarking, multiphysics modeling, uncertainty analysis for nuclear data uncertainties and shielding analysis. Twisted-tube heat exchangers were examined that may provide significant cost reductions because of their improved heat-transfer performance with liquid salts. The impacts on safety and design caused by uncertainties in physical properties of the salt were assessed with recommendations on where added physical property measurements are needed. Work began on understanding radiative heat transfer that becomes important in salt systems at higher temperatures. Materials. Static corrosion tests were conducted on graphite and materials in 700°C salt -- both in the UW laboratory and in the MIT reactor. In addition to static corrosion testing, a circulating salt corrosion loop was built and is operating. Methods to measure salt properties including redox were developed. The presence of carbon increases corrosion. With good redox control, the evidence indicates stainless steel can be used as a material of construction. Benchmarking. An additional series of workshops where held to enable benchmarking and comparison of results between different investigators. Commercialization. The FHR delivers higher average-temperature (~650°C) heat to the power cycle or industry than other reactors. This enables power cycles with lower-cost heat storage for variable electricity to the grid while the reactor operates at base-load -- providing a major competitive advantage by maximizing revenue from electricity sales. In October, 2016, a new startup company named Kairos Power was formed, and opened its first office in Jack London Square, Oakland, California, in January 2017. Kairos Power exists largely due to the work that was accomplished by this IRP and the previous DOE-funded FHR IRP that performed research on FHR technology from 2012 to 2015. In September, 2018, as this IRP is concluding, Kairos Power was staffed at 60 full time employees, working to develop technology derived from this IRP. Many of these employees worked with the IRP before joining Kairos Power 1 (https://kairospower.com). Other students and researchers from this IRP have joined other startup companies, including the Terrapower Molten Chloride Fast Reactor and the Terrestrial Energy development efforts.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗