Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

CBETA 4-pass Orbit Correction and Tolerance Study (CBETA Machine Note #037)

The main goal of this study is to find the tolerance of the CBETA FFAG lattice subjected to various errors. Common error sources include non-ideal magnet positioning and alignment, undesired multipole field strengths, and BPM offsets. In order to fix the beam trajectories (orbits) affected by the errors, dipole kickers have been allocated throughout the FFAG beamline to serve as correctors. Since there are four coexisting orbits in the FFAG, the correction scheme must aim to correct all four of them simultaneously. The simulation is performed using Bmad, developed by Cornell University to model relativistic beam dynamics in customized accelerator lattices. The core of orbit correction is the singular value decomposition (SVD) optimization. As the error magnitudes increase, the beam size and emittance after correction could undesirably increase, and our goal is to find the "individual limit" of each error type beyond which the increases become unacceptable. Typically this limit is reached before the orbits become un-correctable. Similarly we can also find the "combined limit" of various errors. Both limits will be properly defined in the later section.

43 PARTICLE ACCELERATORS↗

Closure Report for Corrective Action Unit 414: Clean Slate III Plutonium Dispersion (TTR) Tonopah Test Range, Nevada

The purpose of this CR is to provide documentation and justification for the clean closure of CAU 414 under the FFACO without further corrective action. This justification is based on historical knowledge of the site, previous site investigations, closureactivities conducted at the site, and the results of verification samples. Clean closure activities included excavating and disposing of radiologically contaminated soil and debris in the vicinity of ground zero, and collecting verification samples to support the corrective action of clean closure. Results confirmed that further corrective action is not required at CAU 414. Based on the corrective action activities conducted, clean closure of the site is complete; the closure objectives established in the CADD/CAP have been achieved; and no further corrective action at the site is required.

54 ENVIRONMENTAL SCIENCES↗

YALINA-booster subcritical assembly pulsed-neutron e xperiments: detector dead time and apatial corrections.

In almost every detector counting system, a minimal dead time is required to record two successive events as two separated pulses. Due to the random nature of neutron interactions in the subcritical assembly, there is always some probability that a true neutron event will not be recorded because it occurs too close to the preceding event. These losses may become rather severe for counting systems with high counting rates, and should be corrected before any utilization of the experimental data. This report examines the dead time effects for the pulsed neutron experiments of the YALINA-Booster subcritical assembly. The nonparalyzable model is utilized to correct the experimental data due to dead time. Overall, the reactivity values are increased by 0.19$ and 0.32$ after the spatial corrections for the YALINA-Booster 36% and 21% configurations respectively. The differences of the reactivities obtained with He-3 long or short detectors at the same detector channel diminish after the dead time corrections of the experimental data for the 36% YALINA-Booster configuration. In addition, better agreements between reactivities obtained from different experimental data sets are also observed after the dead time corrections for the 21% YALINA-Booster configuration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Correction for GALEX Spectroscopic UV Flux Distributions from Comparisons with CALSPEC and IUE

The CALSPEC database of absolute spectral energy distributions (SEDs) from the Hubble Space Telescope is based on pure hydrogen model atmosphere calculations for three unreddened white dwarf stars and represents the current UV flux calibration standard with a precision approaching 1% for well observed stars. Following our previous work to correct International Ultraviolet Explorer (IUE) fluxes, this paper provides an average correction for the Galaxy Evolution Explorer (GALEX) spectral database that places GALEX fluxes on the current CALSPEC scale. Our correction is derived by comparing GALEX spectroscopic flux distributions with CALSPEC and corrected IUE SEDs. This recalibration is relevant for any project based on GALEX archival spectroscopic data, e.g., UV or multi-wavelength analyses, correlating GALEX spectra with other existing or future databases, and planning of new observations. The recalibration will be applied to our planned catalog of corrected GALEX SEDs.

79 ASTRONOMY AND ASTROPHYSICS↗

Iron-corrected Single-epoch Black Hole Masses of DESI Quasars at Low Redshift

We present a study on the possible overestimation of single-epoch supermassive black hole (SMBH) masses in previous works, based on more than 55,000 type 1 quasars at 0.25 < z < 0.8 from the Dark Energy Spectroscopic Instrument (DESI). We confirm that iron emission strength serves as a good tracer of the Eddington ratio, and estimate SMBH masses using an iron-corrected R–L relation for Hβ, where R is the broad-line region size and L is the continuum luminosity. Compared with our measurements, previous canonical measurements without the iron correction are overestimated by a factor of 1.5 on average. The overestimation can be up to a factor of 5 for super-Eddington quasars. The fraction of super-Eddington quasars in our sample is about 5%, significantly higher than 0.4% derived from the canonical measurements. Using a sample featuring both Hβ and Mg II emission lines, we calibrate Mg II -based SMBH masses using iron-corrected, Hβ-based SMBH masses and establish an iron-corrected R–L relation for Mg II . The revised relation features a flatter luminosity dependence with a slope of 0.36 and incorporates an additional term of −0.21R Fe , where R Fe denotes the relative iron strength. We use this formula to build a catalog of about 0.5 million DESI quasars at 0.6 < z < 1.6. If these iron-corrected R–L relations for Hβ and Mg II are valid at high redshift, current mass measurements of luminous quasars at z ≥ 6 would have been overestimated by a factor of 2.3 on average, alleviating the tension between SMBH mass and growth history in the early universe.

active galactic nuclei↗

Scanning ARM Cloud Radar Corrections (SACRCOR)

This dataset contains moments from the Scanning ARM Cloud Radars (SACRs) which have been filtered and corrected in order to provide a product for non-radar meteorologists which contains fewer measurement artifacts and effects from signal propagation. Corrections have been applied to selected moments. The 'reflectivity_corrected' variable has been corrected for gaseous attenuation effects. Dealiasing of Doppler velocities is performed using two algorithms, with the results stored in the variables 'mean_doppler_velocity_corrected' and 'mean_doppler_velocity_corrected2.' This product removes returns from non-atmospheric source, such as insects, ground clutter, and second trip echoes, leaving only meaningful returns from clouds and precipitation. Users should note that the filter mask in this product is not perfect. A small amount of clutter, insects and second trip echo artifacts may still be present in the filtered data, especially near the radar where classification is particularly challenging. Additionally, due to the instrument configuration, no filtering of insects was performed on data from the X-band SACR. Improvements to these algorithms are planned as further testing is performed and additional data becomes available.

54 ENVIRONMENTAL SCIENCES↗

SAIL-Net Raw and Post Corrected POPS Data Fall 2021 - Summer 2023

SAIL-Net is a DOE funded project in the East River Watershed near Crested Butte, Colorado with the goal of advancing our understanding of aerosol-cloud interactions in complex, mountainous regions. Through the deployment of a network of six low cost microphysics nodes in Fall 2021 in the same domain at the SAIL campaign, SAIL-Net provides data on aerosol size distributions, cloud condensation nuclei (CCN), and ice nucleation particles (INP). This network enables the investigation of small-scale variations in complex terrain. Two datasets are provided - one containing raw data and the other containing post-corrected data. The raw dataset provides the raw data recorded from the POPS which were deployed at each of the six sites. These data are organized by site and broken down into daily data files. The six site names used here are: “gothic”, “irwin”, “cbtop”, “cbmid”, “pumphouse”, and “snodgrass”. These data are not cleaned or post-corrected, but some flags have been added. The data are reported at 1 second time resolution. The post-corrected dataset provides the post-corrected and cleaned data recorded from the POPS which were deployed at each of the six sites. This data are also organized by site (same as those found in the raw data) and broken down into daily data files. Unlike the raw POPS data, these data have already been cleaned to remove what we believe are bad values. These data should be ready to use with no cleaning. For a full description of the cleaning and post-correction process, see the readme.

54 ENVIRONMENTAL SCIENCES↗

Detection and Correction of Silent Data Corruption for Large-Scale High-Performance Computing

Faults have become the norm rather than the exception for high-end computing on clusters with 10s/100s of thousands of cores. Exacerbating this situation, some of these faults remain undetected, manifesting themselves as silent errors that corrupt memory while applications continue to operate and report incorrect results. This paper studies the potential for redundancy to both detect and correct soft errors in MPI message-passing applications. Our study investigates the challenges inherent to detecting soft errors within MPI application while providing transparent MPI redundancy. By assuming a model wherein corruption in application data manifests itself by producing differing MPI message data between replicas, we study the best suited protocols for detecting and correcting MPI data that is the result of corruption. To experimentally validate our proposed detection and correction protocols, we introduce RedMPI, an MPI library which resides in the MPI profiling layer. RedMPI is capable of both online detection and correction of soft errors that occur in MPI applications without requiring any modifications to the application source by utilizing either double or triple redundancy. Our results indicate that our most efficient consistency protocol can successfully protect applications experiencing even high rates of silent data corruption with runtime overheads between 0% and 30% as compared to unprotected applications without redundancy. Using our fault injector within RedMPI, we observe that even a single soft error can have profound effects on running applications, causing a cascading pattern of corruption in most cases causes that spreads to all other processes. RedMPI's protection has been shown to successfully mitigate the effects of soft errors while allowing applications to complete with correct results even in the face of errors.

Fiala, David J↗

Validation of Subhourly Clipping Loss Error Corrections: Preprint

Under-performance of solar PV systems is an important issue that increases risks for stakeholders, including developers, investors and operators. Recently some attention has focused on underestimation of inverter clipping losses as a possible source of over-prediction where sub-hourly solar variability is high. Several models and data sets have been analyzed over the past few years, with the aim of quantifying, predicting, and correcting underestimated clipping loss errors for systems with high DC/AC ratio and solar variability. In this research, we apply a machine learning model developed at NREL to two physical PV systems, to correct for subhourly clipping losses. For each system, we compare overall AC power output for the model taken at 1-minute intervals to AC power output taken at 1-hour intervals with the addition of the subhourly clipping correction. Our findings consistently show that the addition of the clipping loss correction lead to a reduction in mean bias error of 0.6\% and 1.1\% for systems A and B, respectively, with no additional filtering applied. When examining high solar variability periods where clipping is more pronounced, system A and B experienced a 1.4\% and 2.5\% reduction in mean bias error, respectively, when the clipping correction was applied.

machine learning↗

Passive and Active Neutron Matrix Correction for Heterogeneous Distributions Utilizing the Neutron Imaging Technique

Classical Non-Destructive Assay (NDA) Passive Neutron Coincidence Counting (PNCC) and Differential Die-Away (DDA) active neutron interrogation techniques [1, 2] are well suited for determining the gross matrix correction factors for homogenous mass distributions of Special Nuclear Material (SNM) within an interfering waste drum matrix. These measured passive and active matrix correction factors are crucial in quantifying the SNM mass, associated Total Measurement Uncertainty (TMU), and Minimum Detectable Activity (MDA) within the drum. When heterogeneous SNM mass distributions are encountered, the measured SNM mass, TMU and MDA biases introduced may be 100%, or greater, especially for dense hydrogenous matrices. The standard matrix correction factors can be adjusted if a coarse spatial image of the SNM mass, relative to the matrix, is available. The image can then be analyzed to determine the spatially-adjusted, matrix correction factors case by case. This image analysis approach was accomplished by modifying the standard Passive-Active Neutron (PAN) counter design [3] to accommodate a unique data acquisition architecture that supports a newly developed image acquisition and analysis application called the Neutron Imaging Technique (NIT). The NIT functionality supports both PNCC and DDA acquisition and analysis modes and exploits the symmetry between a stored set of factory acquired NIT images with those from the unknown PAN assay. The NIT result is then an adjustment to the classical correction factor reducing, if not removing, the SNM mass bias and revealing the true TMU and MDA values. In this paper we describe the NIT for the PAN design from the software and algorithmic perspectives and how this technique accommodates waste matrix drums that are difficult, from the classical standpoint, if not impossible, to extract meaningful SNM mass, TMU and MDA results. (authors)

42 ENGINEERING↗

Uncertainty Quantification of Spatial Correction Factor for Sjoestrand Method due to Cross-section Data

Accelerator-driven System (ADS), which couples a subcritical core with a spallation neutron source, is proposed as a nuclear transmutation technology to reduce the radioactive half-life of high-level waste. To maintain a safe operation in ADS, the core should be kept in subcritical state. Thus, the subcritical state of the core must be quantified through measurement of subcriticality, which is a quantitative margin from critical state. The area ratio method, or the Sjoestrand method, is one of the subcriticality measurement techniques applicable to the ADS. In this method, the absolute value of subcriticality can be obtained by analyzing the temporal variation of neutron density in the core due to the periodic injection of neutron pulses. In practice, the value of subcriticality is measured by the temporal variation of neutron count rate detected by a detector in the core. Time integrals of count rates due to prompt and delayed neutrons A{sub p} and A{sub d}, are measured. Then, the ratio of A{sub p} to A{sub d}, which is called as the area ratio, yields negative reactivity -ρ, i.e. subcriticality, in dollar units: A{sub p}/A{sub d} ≅ -ρ/β{sub eff'} (1) where β{sub eff} is the effective delayed neutron fraction. Equation (1) represents the basic idea of the Sjoestrand method. Note, however, that Eq. (1) is approximately derived using the point kinetics model. In an actual subcritical system, the measured area ratio is not necessarily equal to the exact value of subcriticality in dollar units, due distortion by spatial higher-order modes. Hence, in the actual measurement, this spatial effect is corrected by a spatial correction factor such as the Bell and Glasstone correction factor (the Bell factor), or by extraction of the fundamental mode (so-called the extrapolated area ratio method). In addition, there is an effect due to the neutron detector materials (e.g. {sup 3}He(n,p) and {sup 235}U(n,f)). These effects must be considered in the correction of the measured area ratio. In this study, we focused on the uncertainty of Bell factor. The Bell factor f is defined by the ratio of the area ratio to the subcriticality as follows: f ≡ -[ρ/β{sub eff}]/[A{sub p}/A{sub d}] (2) The Bell factor f can be evaluated by a core analysis. By multiplying the measured area ratio by the Bell factor?, the spatial higher-order mode effect in the area ratio can be corrected. However, the uncertainty of the Bell factor due to uncertainties of cross-section data (covariance data) has not been quantitatively evaluated so far. In this study, we propose a method to quantify the uncertainty of the Bell factor in an actual core analysis. As a feasibility study, the uncertainty quantification is carried out in a simple one-dimensional subcritical core system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Regional Multi-station Discriminants: Magnitude, Distance and Amplitude Corrections and Sources of Error

Magnitude, distance and amplitude corrections (MDAC) made to observed regional amplitudes are necessary so that what remains in the corrected amplitude is mostly information about the seismic source-type. Corrected amplitudes can be used in ratios to discriminate between earthquakes and explosions. However, there remain source effects such as those due to depth, focal mechanism, local material property and apparent stress variability that cannot easily be determined and applied as amplitude corrections. We develop a mathematical model to capture these near source effects as random (unknown) giving an error partition of three sources: model inadequacy, station noise and amplitude correlations. This mathematical model is the basis for a general multi-station regional discriminant formulation. The standard error of the discriminant includes these three sources of error in its formulation. The developed methods are demonstrated with a collection of Nevada Test Site (NTS) events observed at regional stations. Importantly, the proposed formulation includes all corrected amplitude information through the construction of multi-station discriminants. In contrast, previous studies have only computed discriminants from single stations having both P and S amplitudes. The proposed multi-station approach has similarities to the well established m{sub b} versus M{sub s} discriminant and represents a new paradigm for the regional discrimination problem.

58 GEOSCIENCES↗

Absorption Correction for Cylindrical and Annular Specimens and their Containers or Supports

Abstract The absorption correction for cylindrical specimens, typically capillary or annular, is affected by absorption in both the specimen and supporting material. These corrections are calculated here using numerical integration of the lengths through the different regions of the specimen that the beam traverses. Suitable formulae have been derived and built into a computer program for calculating the absorption correction for a range of cylindrical geometries. The influence of absorption in the support is most significant for annular specimens on a highly absorbing core, and for capillary specimens of highly absorbing compounds. The error arising from neglecting absorption in the specimen and additionally in the capillary is demonstrated in Rietveld refinements of LaB6. Interpolation of correction factors between values calculated at discrete θ intervals, and θ offsets arising from absorption are also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Energy Scale Correction Techniques for the X-ray Transition Edge Sensors of the Athena mission

The X-ray Integral Field Unit (X-IFU) onboard the future European X-ray telescope Athena will be the first space instrument carrying an array of more than a thousand transition edge sensors. One of the key challenges of the X-IFU is the measurement of narrow X-ray atomic lines to determine velocity shifts at an unprecedented level of accuracy. For this reason, the energy scale of the instrument needs to be known with extreme accuracy, of 0.4 eV (1σ) up to 7 keV. The energy scale will be measured on the ground through a dedicated calibration campaign using fiducial X-ray sources. Though calibrated, the energy scale is extremely sensitive to the environmental conditions around the TES array, and drifts in the readout chain electronics. Uncorrected, the energy scale can naturally drift up to hundreds of eVs. Changes of the TES gain will be monitored via onboard X-ray calibration sources, and the energy scale will be corrected either per pixel, or within a small groups of pixels. Although simulations show that a 0.4 eV level can be achieved, the very high accuracy required by the X-IFU calls for experimental validation. A dedicated measurement campaign has been performed by NASA Goddard Space Flight Center to characterize the energy scale of a prototype kilo-pixel array of X-IFU-representative TESs. The analysis of the data demonstrated the ability to correct for various drifts using two fiducial lines to track the temporal gain variation. In this paper, we propose to extend this study on the same data set by investigating multi-parameter correction techniques based on both the pulse-height of the fiducial line and the prepulse baseline level, using the knowledge of the TES energy scale at reference temperature/magnetic field set points acquired on the ground. Investigations on the co-adding of pixels to perform a joint correction over pools of pixels is also explored.

79 ASTRONOMY AND ASTROPHYSICS↗

A relative radiometric correction method for airborne SWIR hyperspectral image using the side-slither technique

Stripe noise still remains in airborne short-wave infrared (SWIR) hyperspectral (HS) images after laboratory calibration due to the stray light of HS imager, nonlinear response of infrared focal plane array, and the distinct difference of equivalent color temperature between the integrating sphere and the sun. It is difficult to get a sun-like radiation source, and we apply the side-slither technique for relative radiometric correction of HS images. The calibration data corresponding to different irradiance were obtained by the side-slither technique of imager. Then, the two-point multi-section method is used for relative radiometric correction of HS images. This paper presents the principle, the experimental results, and the analysis of the proposed method. To validate the effectiveness of this method, it was compared with other methods and evaluated by quantitative quality indices. The results reveal that this method has a good performance in relative radiometric correction of HS image and is superior to the laboratory calibration based on integrating sphere. Consequently, the proposed method can successfully eliminate the adverse effect caused by the difference of equivalent color temperature between radiation sources, and also can improve the accuracy of HS applications such as absolute radiation correction and target recognition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization-based mesh correction with volume and convexity constraints

Here, we consider the problem of finding a mesh such that 1) it is the closest, with respect to a suitable metric, to a given source mesh having the same connectivity, and 2) the volumes of its cells match a set of prescribed positive values that are not necessarily equal to the cell volumes in the source mesh. Also, this volume correction problem arises in important simulation contexts, such as satisfying a discrete geometric conservation law and solving transport equations by incremental remapping or similar semi-Lagrangian transport schemes. In this paper we formulate volume correction as a constrained optimization problem in which the distance to the source mesh defines an optimization objective, while the prescribed cell volumes, mesh validity and/or cell convexity specify the constraints. We solve this problem numerically using a sequential quadratic programming (SQP) method whose performance scales with the mesh size. To achieve scalable performance we develop a specialized multigrid-based preconditioner for optimality systems that arise in the application of the SQP method to the volume correction problem. Numerical examples illustrate the importance of volume correction, and showcase the accuracy, robustness and scalability of our approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accelerating eigenvalue computation for nuclear structure calculations via perturbative corrections

Subspace projection methods utilizing perturbative corrections have been proposed for computing the lowest few eigenvalues and corresponding eigenvectors of large Hamiltonian matrices. In this paper, we build upon these methods and introduce the term Subspace Projection with Perturbative Corrections (SPPC) method to refer to this approach. We tailor the SPPC for nuclear many-body Hamiltonians represented in a truncated configuration interaction subspace, i.e., the no-core shell model (NCSM). We use the hierarchical structure of the NCSM Hamiltonian to partition the Hamiltonian as the sum of two matrices. The first matrix corresponds to the Hamiltonian represented in a small configuration space, whereas the second is viewed as the perturbation to the first matrix. Eigenvalues and eigenvectors of the first matrix can be computed efficiently. Because of the split, perturbative corrections to the eigenvectors of the first matrix can be obtained efficiently from the solutions of a sequence of linear systems of equations defined in the small configuration space. These correction vectors can be combined with the approximate eigenvectors of the first matrix to construct a subspace from which more accurate approximations of the desired eigenpairs can be obtained. We show by numerical examples that the SPPC method can be more efficient than conventional iterative methods for solving large-scale eigenvalue problems such as the Lanczos, block Lanczos and the locally optimal block preconditioned conjugate gradient (LOBPCG) method. The method can also be combined with other methods to avoid convergence stagnation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Corrections for the geometric distortion of the tube detectors on SANS instruments at ORNL

Small-angle neutron scattering instruments at the Oak Ridge National Laboratory's High Flux Isotope Reactor were upgraded in area detectors from the large, single volume crossed-wire detectors originally installed to staggered arrays of linear position-sensitive detectors (LPSDs). The specific geometry of the LPSD array requires that approaches to data reduction traditionally employed be modified. Here, two methods for correcting the geometric distortion produced by the LPSD array are presented and compared. The first method applies a correction derived from a detector sensitivity measurement performed using the same configuration as the samples are measured. In the second method, a solid angle correction is derived that can be applied to data collected in any instrument configuration during the data reduction process in conjunction with a detector sensitivity measurement collected at a sufficiently long camera length where the geometric distortions are negligible. Furthermore, both methods produce consistent results and yield a maximum deviation of corrected data from isotropic scattering samples of less than 5% for scattering angles up to a maximum of 35°. The results are broadly applicable to any SANS instrument employing LPSD array detectors, which will be increasingly common as instruments having higher incident flux are constructed at various neutron scattering facilities around the world.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗