Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controllable loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Fully integrated multi-phase buck converter with coupled air core inductors

A multi-phase buck switching converter having grouped pairs of phases, each phase using two magnetically coupled air-core inductors. For each group, a first driver circuit controlling switching of a first power transistor switching circuit coupled to a first air-core inductor output for driving an output load at the first phase. A second driver circuit controlling switching of a second power transistor switching circuit coupled to a second air-core inductor output for driving said output load at the second phase. The first and second phases are spaced 180° apart. The coupled air-core inductors per group of such orientation, separation distance and mutual inductance polarity relative to each other such that magnetic coupling between the two or more inductors at each phase results in a net increase in effective inductance per unit volume. Each air-core inductor is a metal slab of defined length, height and thickness formed using back-end-of-line semiconductor manufacturing process.

Zhang, Xin↗

Flashlamp drive system for a high-energy 10–100 kHz pulse-burst Nd:YAG laser

We present the design of the flashlamp drive system for the NG100 laser, a 1 J/pulse, 10–100 kHz, pulse-burst Nd:YAG laser system being developed for application in a Thomson scattering plasma diagnostic. This flashlamp drive system is under active development, with a prototype now being constructed. The flashlamp drive system is modular, with each module capable of driving a series pair of linear flashlamps. Each drive module contains and is controlled by a dedicated Analog Regulator Controller. Thus each module is independently operable and controllable. This modular approach imposes no intrinsic limit to the number of modules that may be applied to drive the flashlamp pairs in a laser system. Each flashlamp drive module has a switch-regulated topology. An 1800 V main capacitor bank provides 25 kJ of energy storage, while a lower voltage output capacitor bank provides filtering and the initial energy delivered to the flashlamps at the start of the drive pulse. The main bank is recharged after each flashlamp drive pulse. As energy is drawn from the output bank by the flashlamps, an IGBT switching regulator feeds current from the main bank through an inductor to replenish the output capacitor bank. The rate of replenishment is feedback-controlled to maintain a regulated supply of power to the flashlamp load, with a setpoint range of 0.07 to 1.65 MW. An Analog Regulator Controller produces two-state variable pulse width feedback switching of the regulator IGBT. The switching frequency is ≤ 20 kHz, dynamically adjusted to limit ripple of the flashlamp power to ±3% statistical standard deviation of mean. For development or troubleshooting, each module is operable independent of the laser digital control system (microcontroller and FPGA).

Plasma diagnostics - interferometry↗

Battery inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 30 kW off-the-shelf grid following battery inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Split phase inverter data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 8.35 kW off-the-shelf grid following split phase PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mechanistic basis of post-treatment control of SIV after anti-α4β7 antibody therapy

Treating macaques with an anti-α4β7 antibody under the umbrella of combination antiretroviral therapy (cART) during early SIV infection can lead to viral remission, with viral loads maintained at < 50 SIV RNA copies/ml after removal of all treatment in a subset of animals. Depletion of CD8+ lymphocytes in controllers resulted in transient recrudescence of viremia, suggesting that the combination of cART and anti-α4β7 antibody treatment led to a state where ongoing immune responses kept the virus undetectable in the absence of treatment. A previous mathematical model of HIV infection and cART incorporates immune effector cell responses and exhibits the property of two different viral load set-points. While the lower set-point could correspond to the attainment of long-term viral remission, attaining the higher set-point may be the result of viral rebound. Here we expand that model to include possible mechanisms of action of an anti-α4β7 antibody operating in these treated animals. We show that the model can fit the longitudinal viral load data from both IgG control and anti-α4β7 antibody treated macaques, suggesting explanations for the viral control associated with cART and an anti-α4β7 antibody treatment. This effective perturbation to the virus-host interaction can also explain observations in other nonhuman primate experiments in which cART and immunotherapy have led to post-treatment control or resetting of the viral load set-point. Interestingly, because the viral kinetics in the various treated animals differed—some animals exhibited large fluctuations in viral load after cART cessation—the model suggests that anti-α4β7 treatment could act by different primary mechanisms in different animals and still lead to post-treatment viral control. This outcome is nonetheless in accordance with a model with two stable viral load set-points, in which therapy can perturb the system from one set-point to a lower one through different biological mechanisms.

60 APPLIED LIFE SCIENCES↗

Nontargeted vs. Targeted vs. Smart Load Shifting Using Heat Pump Water Heaters

Deployment of CTA-2045–enabled devices is increasing in the U.S. market. These devices allow utilities or third-party aggregators to control appliance energy use in homes, and could also be applied to end uses in small commercial buildings. This study focuses on a field study using CTA-2045–enabled water heaters to shift electric load off the peak and toward periods when renewable resources are more prevalent (e.g., near noon for solar resources and near midnight for wind resources). The following load shifting strategies were compared to understand effects on the aggregate load-shifting capabilities of Heat Pump Water Heaters (HPWHs) and on consumer hot water supply: non-targeted (traditional), targeted (grouped, with different shifting schedules) and “smart” (adaptive control commands). The results of this study show that targeted and smart control strategies yield significantly more load-shifting potential from a population of water heaters than the non-targeted approach without sacrificing hot water supply to occupants. However, as control commands become more aggressive, aggregators may face challenges in meeting consumer hot water demand. Furthermore, the findings and lessons learned can benefit electric utilities and inform updates to manufacturer controls and communications standards. The data collected may also be useful for developing and validating HPWH models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Engineered Multifunctional Composite for Passive Sensing, Power Harvesting, and In Situ Damage Identification with Enhanced Mechanical Performance

A multifunctional fiber-reinforced composite with passive self-sensing, energy-harvesting, and damage detection capabilities is presented. In this work, barium titanate piezoelectric microparticles are deposited on basalt fibers by a scalable, low-cost, environmentally friendly continuous feed-through process. The resulting composite derives a superior interlaminar shear strength from the microparticle-modified fiber–matrix interfaces. The composite also demonstrates passive self-sensing capabilities that produce electrical signals proportional to various dynamic loading events. Vibration and strain-controlled experiments are performed on composite beams to quantify the sensitivity and power output as a function of input acceleration and strain. Furthermore, these composite-generated electrical signals are used to identify in situ damage initiation for structural health monitoring to inform composite damage prior to structural failure. In brief, this truly multifunctional composite simultaneously displays a sensitivity of 0.5–2.6 mV g -1 at a resolution of 0.045–0.20g (g = gravitational acceleration), energy harvesting in the range of nW cc -1 , and prediction of early damage by exhibiting 0.017–1.17 mV peaks in voltage–time history profiles while assuring ≈20% improved interlaminar shear strength.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enabling 6C Fast Charging of Li–Ion Batteries with Graphite/Hard Carbon Hybrid Anodes

Li-ion batteries that can simultaneously achieve high-energy density and fast charging are essential for electric vehicles. Graphite anodes enable a high-energy density, but suffer from an inhomogeneous reaction current and irreversible Li plating during fast charging. In contrast, hard carbon exhibits superior rate performance but lower energy density owing to its lower initial coulombic efficiency and higher average voltage. In this work, these tradeoffs are overcome by fabricating hybrid anodes with uniform mixtures of graphite and hard carbon, using industrially-relevant multi-layer pouch cells (>1 Ah) and electrode loadings (3 mAh cm –2 ). By controlling the graphite/hard carbon ratio, this study shows that battery performance can be systematically tuned to achieve both high-energy density and efficient fast charging. Pouch cells with optimized hybrid anodes retain 87% and 82% of their initial specific energy after 500 cycles of 4C and 6C fast-charge cycling, respectively. This is significantly higher than the 61% and 48% specific energy retention with graphite anodes under the same conditions. The enhanced performance is attributed to improved homogeneity of the reaction current throughout the hybrid anode, which is supported by continuum-scale modeling. Furthermore, this process is directly compatible with existing roll-to-roll battery manufacturing, representing a scalable pathway to fast charging.

25 ENERGY STORAGE↗

Renal vascular control during normothermia and passive heat stress does not differ between healthy younger men and women

The mechanisms underlying greater heat-induced acute kidney injury risk in men versus women remain unknown. This study examined renal vascular control, including both vasodilatory (oral protein load) and vasoconstrictor (cold presser test) responses, during normothermia and heat stress and compared these responses between men and women. The results indicated that in both conditions neither renal vasodilatory nor vasoconstrictor responses differ between younger men and younger women.

Physiology↗

Ring Pull Strain Analysis

Ring Pull Strain Analysis (RPSA) is a framework for analysis of Digital Image Correlation (DIC) data of gaugeless ring pull testing. It is meant for analysis of rings cut from tube cross sections and pulled in a displacement-controlled tensile test. This code takes load frame data, images take during testing, and csv files from the DIC analysis of those images and allows the user to analyze and plot data from the test. Some important features of the software include getting the strain values as a function of radial distance and angle, plotting of the strain around the ring, and stress-strain analysis of the load frame data.

Beck, Peter↗

Ring Pull Strain Analysis

Ring Pull Strain Analysis (RPSA) is a framework for analysis of Digital Image Correlation (DIC) data of gaugeless ring pull testing. It is meant for analysis of rings cut from tube cross sections and pulled in a displacement-controlled tensile test. This code takes load frame data, images take during testing, and csv files from the DIC analysis of those images and allows the user to analyze and plot data from the test. Some important features of the software include getting the strain values as a function of radial distance and angle, plotting of the strain around the ring, and stress-strain analysis of the load frame data. Additional capability is included with Ring Pull Coating Analysis (RPCA, also part of the software). Additional images are taken of samples with an outer coating and are used to correlate failure of the coating with strain values measured with DIC.

Beck, Peter↗

UMap: An application-oriented user level memory mapping library

Exploiting the prominent role of complex memories in exascale node architecture, the UMap page fault handler offers new capabilities to access large memory-mapped data sets directly. UMap provides flexible configuration options to customize page handling to each application, including analysis of massive observational and simulation data sets. The high-performance design features I/O decoupling, dynamic load balancing, and application-level controls. Page faults triggered by application threads and processes accessing data mapped to a UMapp’ed region are handled via the Linux userfaultfd protocol, an asynchronous message-oriented kernel-user communication mechanism that avoids the context switch penalty of traditional signal fault handlers. UMap is fully open source. In this paper, we give an overview of the UMap library architecture, its extensible plugin architecture, and the use/performance of UMap in emerging heterogeneous memory hierarchies such as near-node Non-volatile Memory (NVM) and network attached memories. We highlight new capabilities in two pagefault management plugins, the NetworkStore and SparseStore. We demonstrate the integration between UMap and multiple ECP products including Caliper, Metall, ZFP, Mochi, and Ripples.

97 MATHEMATICS AND COMPUTING↗

A machine learning-based fast frequency response control for a VSC-HVDC system

An HVDC system can realize a very fast frequency response to the disturbed system under a contingency because its active power control is decoupled from the frequency deviation. However, most of existing HVDC frequency control strategies are coupled with system primary frequency control and secondary frequency control. Since the traditional system frequency control is dominated by the thermal generators, the advantage of the fast response of the HVDC system is not made fully used. The development of a frequency response estimation based on a machine learning algorithm provides another approach to improve the frequency response capability of the HVDC system. Different from other frequency deviation tracking strategies, a machine learning based HVDC frequency response control can directly increase the power flow of a HVDC system by estimation of the system generator or load lost. In this paper, a fast frequency response control using a HVDC system for a large power system disturbance based on the multivariate random forest regression (MRFR) algorithm is proposed. The simulation is carried out with an integrated power system model based on the North American interconnections. The simulation results indicate that the proposed MRFR based frequency response control can significantly improve the frequency low point during an event, while stabilizing the frequency in advance.

42 ENGINEERING↗

Leveraging Computational Storage Devices in Campaign Storage [Slides]

Computational storage provides new ways of accelerating data-intensive applications. In-drive data management schemes matter (O_DIRECT, clustered index). Layer violation: “cheating” one filesystem may be possible; cheating multiple layers of filesystems is hard (FS internal load balancing, fail over, compression, concurrency control). The future directions include block-based acceleration to object-based acceleration.

97 MATHEMATICS AND COMPUTING↗

A novel methodology for assessing the hygroscopicity of aerosol filter samples

Abstract. Due to US regulations, concentrations of hygroscopic inorganic sulfate and nitrate have declined in recent years, leading to an increased importance of the hygroscopic nature of organic matter (OM). The hygroscopicity of OM is poorly characterized because only a fraction of the multitude of organic compounds in the atmosphere is readily measured, and there is limited information on their hygroscopic behaviors. Hygroscopicity of aerosol is traditionally measured using a humidified tandem differential mobility analyzer (HTDMA) or electrodynamic balance (EDB). EDB measures water uptake by a single particle. For ambient and chamber studies, HTDMA measurements provide water uptake and particle size information but not chemical composition. To fill this information gap, we developed a novel methodology to assess the water uptake by particles collected on Teflon filters. This method uses the same filter sample for both hygroscopicity measurements and chemical characterization, thereby providing an opportunity to link the measured hygroscopicity with ambient particle composition. To test the method, hygroscopic measurements were conducted in the laboratory for ammonium sulfate, sodium chloride, glucose, and malonic acid, which were collected on 25 mm Teflon filters using an aerosol generator and sampler. Constant-humidity solutions (CHSs), including potassium chloride, barium chloride dihydrate, and potassium sulfate, were employed in a saturated form to maintain the relative humidity (RH) at approximately 84 %, 90 %, and 97 % in small chambers. Our preliminary experiments revealed that, without the pouch, water uptake measurements were not feasible due to rapid water loss during weighing. Additionally, we observed some absorption by the aluminum pouch itself. To account for this, concurrent measurements were conducted for both the loaded and the blank filters at each RH level. Thus, the dry loaded and blank Teflon filters were placed in aluminum pouches with one side open and in RH-controlled chambers for more than 24 h. The wet loaded samples and wet blanks were then weighed using an ultramicrobalance to determine the water uptake by the respective compound and the blank Teflon filter. The net amount of water absorbed by each compound was calculated by subtracting the water uptake of the blank filter from that of the wet loaded filter. Hygroscopic parameters, including the water-to-solute (W / S) ratio, molality, mass fraction solute (mfs), and growth factors (GFs), were calculated from the measurements. The results obtained are consistent with those reported by the Extended Aerosol Inorganics Model (E-AIM) and previous studies utilizing HTDMA and EDB for these compounds, highlighting the accuracy of this new methodology. This new approach enables the hygroscopicity and chemical composition of individual filter samples to be assessed so that in complex mixtures, such as chamber and ambient samples, the total water uptake can be parsed between the inorganic and organic components of the aerosol.

54 ENVIRONMENTAL SCIENCES↗

NREL: Working Towards a Superlab 2.0 With ESnet and Other National Laboratories

We can currently link models and simulations across the national laboratory complex, but imagine connecting these models with equipment, devices, and scientists so they can work together as if side by side instead of thousands of miles apart. In a future like this, researchers could run experiments that leverage thousands of devices to model the millions of devices that make up our increasingly complex energy systems. With such resources, labs could simulate, for example, the electric grid of California and validate control strategies to best serve critical loads during outages caused by wildfires. The National Renewable Energy Laboratory's (NREL's) Advanced Research on Integrated Energy Systems (ARIES) platform is making that vision a reality, one step at a time.

ARIES↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗