At least 613 records · Page 34

The Potential of High-Contrast Coronagraphy

The direct detection of faint companions near much brighter stars requires the development of very high-contrast, small field-of-view detection techniques, and the past decade has seen remarkable conceptual and instrumental progress in this area. New coronagraphic techniques are being developed and deployed, as are extreme adaptive optics (ExAO) systems that will enable the advantageous exploitation of these new techniques. This paper provides a short overview of promising high contrast coronagraphic techniques, as well as recent examples of ExAO coronagraphy and transit measurements obtained with the ExAO-level "well-corrected subaperture" at Palomar.

Serabyn, E.↗

The CHARIS IFS for high contrast imaging at Subaru

The Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) is an integral field spectrograph (IFS) being built for the Subaru telescope. CHARIS will take spectra of brown dwarfs and hot Jovian planets in the coronagraphic image provided by the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) and AO188 adaptive optics systems. The system is designed to detect objects five orders of magnitude dimmer than their parent star down to an 80 milliarcsecond inner working angle. For characterization, CHARIS has a high-resolution prism providing an average spectral resolution of R82, R69, and R82 in J, H, and K bands respectively. The so-called discovery mode uses a second low-resolution prism with an average spectral resolution of R19 spanning 1.15-2.37 microns (J+H+K bands). This is unique compared to other high contrast IFS designs. It augments low inner working angle performance by reducing the separation at which we can rely on spectral differential imaging. The principal challenge for a high-contrast IFS is quasi-static speckles, which cause undue levels of spectral crosstalk. CHARIS has addressed this through several key design aspects that should constrain crosstalk between adjacent spectral features to be below 1%. Sitting on the Nasmyth platform, the alignment between the lenslet array, prism, and detector will be highly stable, key for the performance of the data pipeline. Nearly every component has arrived and the project is entering its final build phase. Here we review the science case, the resulting design, status of final construction, and lessons learned that are directly applicable to future exoplanet instruments.

Subaru Coronagraphic Extreme Adaptive Optics (SCEx↗

A Qualitative Review of Selected Infrared Flow Visualization Processing Techniques: Contrast Enhancement and Frequency Domain Analysis

The deployment and integration of high-sensitivity infrared cameras in a transonic wind tunnel test environment has resulted in a unique capability to image aerodynamic phenomena in real-time. Multi-camera infrared flow visualization data systems are now routinely utilized at the NASA Ames Unitary Plan Wind Tunnel. The small flow-induced temperature gradients on the surface of the wind tunnel test article coupled with the high bit-depth of the infrared camera sensor makes the processing of the image data critically important. An image processing routine must enhance features of interest with minimal artifacts. Additionally, the production wind tunnel test environment demands that these processed images are made available in a real-time, automatic fashion. Therefore, any image processing routine must be computationally economical and enhance the image data with minimal input from a human operator. The following seeks to qualitatively explore selected image processing techniques by assessing their effectiveness to resolve flow features on a wind tunnel test article. A multi-scale contrast enhancement technique is introduced as well as a new implementation of a multi-scale, non-interpolated adaptive histogram equalization. Finally, a novel method is introduced that demonstrates the ability to resolve flow features imaged on bare-steel test articles possessing low emissivity. This method merges frequency domain analysis with contrast enhancement and has the potential to extend the application of infrared flow-visualization within the wind tunnel test environment.

Infrared Imaging↗

Hi-5: A Potential High-Contrast Thermal Near-Infrared Imager for the VLTI

Hi-5 is a high-contrast (or high dynamic range) infrared imager project for the VLTI. Its main goal is to characterize young extra-solar planetary systems and exozodiacal dust around southern main-sequence stars. In this paper, we present an update of the project and key technology pathways to improve the contrast achieved by the VLTI. In particular, we discuss the possibility to use integrated optics, proven in the near-infrared, in the thermal near-infrared (L and M bands, 3-5 μm) and advanced fringe tracking strategies. We also address the strong exoplanet science case (young exoplanets, planet formation, and exozodiacal disks) offered by this wavelength regime as well as other possible science cases such as stellar physics (fundamental parameters and multiplicity) and extragalactic astrophysics (active galactic nuclei and fundamental constants). Synergies and scientific preparation for other potential future instruments such as the Planet Formation Imager are also briefly discussed.

exozodiacal dust↗

High-Contrast Polarimetry Observation of the T Tau Circumstellar Environment

We conducted high-contrast polarimetry observations of T Tau in the H-band, using the High Contrast Instrument for the Subaru Next Generation Adaptive Optics instrument mounted on the Subaru Telescope, revealing structures as near as 0farcs1 from the stars T Tau N and T Tau S. The whole T Tau system is found to be surrounded by nebula-like envelopes, and several outflow-related structures are detected in these envelopes. We analyzed the detailed polarization patterns of the circumstellar structures near each component of this triple young star system and determined constraints on the circumstellar disks and outflow structures. We suggest that the nearly face-on circumstellar disk of T Tau N is no larger than 0".8, or 117 au, in the northwest, based on the existence of a hole in this direction, and no larger than 0".27, or 40 au, in the south. A new structure, "N5," extends to about 0."42, or 59 au, southwest of the star, and is believed to be part of the disk. We suggest that T Tau S is surrounded by a highly inclined circumbinary disk with a radius of about 0."3, or 44 au, with a position angle of about 30°, that is misaligned with the orbit of the T Tau S binary. After analyzing the positions and polarization vector patterns of the outflow-related structures, we suggest that T Tau S should trigger the well-known E–W outflow, and is also likely to be responsible for a southwest precessing outflow "coil" and a possible south outflow.

Yang, Yi↗

Characterization of Low Mass Deformable Mirrors and ASIC Driver for High-Contrast Imaging

The development of compact, high performance Deformable Mirrors (DMs) is one of the most important techno-logical challenges for high-contrast imaging on space missions. Microscale Inc. has fabricated and characterized piezoelectric stack actuator deformable mirrors (PZT-DMs) and Application-Speci c Integrated Circuit (ASIC) drivers for direct integration. The DM-ASIC system is designed to eliminate almost all cables, enabling a very compact optical system with low mass and low power consumption. We report on the optical tests used to evaluate the performance of the DM and ASIC units. We also compare the results to the requirements for space-based high-contrast imaging of exoplanets. .

Prada, Camilo Mejia↗

Evaluation of Tablet-Based Methods for Assessment of Contrast Sensitivity

Some astronauts have suffered degradation of vision during long-duration space flight, suffering from a condition that has come to be known as Spaceflight Associated Neuro-ocular Syndrome (SANS). While related morphological changes can be observed with imaging technologies such as optical coherence tomography (OCT), it may be useful to have a rapid method for functional vision assessment. In this paper, we compare three tablet-based methods for rapid assessment of contrast sensitivity. First, a relatively novel method developed expressly for touch screens, in which the subject ”swipes” a frequency/contrast sweep grating to indicate the boundary between visible and invisible patterns; second, a method-of-adjustment task in which the subject adjusts the contrast of a grating patch up and down to bracket the visual threshold; and third, a traditional temporal two-alternative forced choice (2AFC) task, in which the subject is presented with a near-threshold stimulus in one of two intervals, and must report the interval containing the stimulus. The swipe method shows variability comparable to the 2AFC method, and shows good agreement in estimates of the spatial frequency of peak sensitivity. The absolute sensitivity estimated with the swipe method is higher than that of the other methods, perhaps because subjects are biased to trace outside of the visible pattern region, or perhaps due to stimulus differences.

Mulligan, Jeffrey B.↗

Keck/OSIRIS Paβ High-contrast Imaging and Updated Constraints on PDS 70b

We present a high-contrast imaging search for Paβ line emission from protoplanets in the PDS 70 system with Keck/OSIRIS integral field spectroscopy. We applied the high-resolution spectral differential imaging technique to the OSIRIS J-band data but did not detect the Paβ line at the level predicted using the parameters of Hashimoto et al. (2020). This lack of Paβ emission suggests the MUSE-based study may have overestimated the line width of Hα. We compared our Paβ detection limits with the previous Hα flux and Hβ limits and estimated AV to be ∼0.9 and 2.0 for PDS 70 b and c, respectively. In particular, PDS 70 b’s AV is much smaller than implied by high-contrast near-infrared studies, which suggests the infrared-continuum photosphere and the hydrogen-emitting regions exist at different heights above the forming planet.

Taichi Uyama↗

Enabling High-Contrast Imaging of Binary Stars With the Roman Space Telescope Coronagraph Instrument

A large fraction of Sun-like stars is contained in binary systems, in fact within 10 pc there are 67 FGK stars, out of which 42 belong to a multi-star system, and 28 have companion leak that is greater than 1e-9 contrast, assuming typical Hubble-quality space optics. Currently, those binary stars are not included in the Roman Space Telescope Coronagraph Instrument target list, but they could be observed if high-contrast imaging around binary star systems using Roman was possible. The Multi-Star Wavefront Control (MSWC) algorithm can be used to suppress companion star leakage. If the targets have angular separations larger than the Nyquist controllable region of the Deformable Mirror, MSWC must operate in its Super-Nyquist (SN) mode. This mode requires a target star replica within the SN region in order to provide the ability to null speckles at SN angular separations. For the case of Roman, more than half of the targets that can be observed using MSWC, including Alpha Centauri, have angular separations larger than the Nyquist controllable region of the 48x48 actuator Deformable Mirror (DM) to be used. In this paper, we describe how super-Nyquist MSWC can be implemented in Roman CGI adding a mild grating on a replica of the Wide-field Shaped Pupil mask, which would use a spare space in the Shaped Pupil Active Mechanism. We present the feasibility analysis, simulation results, and discuss the latest results on MSWC experiment from three different laboratories at NASA Ames, the Jet Propulsion Laboratory, and the Subaru telescope.

Prada, Camilo Mejia↗

LUVOIR-ECLIPS Closed-Loop Adaptive Optics Performance and Contrast Predictions

One of the primary science goals of the Large UV/Optical/Infrared Surveyor (LUVOIR) mission concept is to detect and characterize Earth-like exoplanets orbiting nearby stars with direct imaging. The success of its coronagraph instrument ECLIPS (Extreme Coronagraph for Living Planetary Systems) depends on the ability to stabilize the wavefront from a large segmented mirror such that optical path differences are limited to tens of picometers RMS during an exposure time of a few hours. In order to relax the constraints on the mechanical stability, ECLIPS will be equipped with a wavefront sensing and control (WS\&C) architecture to correct wavefront errors up to temporal frequencies $\gtrsim$1 Hz. These errors may be dominated by spacecraft structural dynamics exciting vibrations at the segmented primary mirror. In this work, we present detailed simulations of the WS\&C system within the ECLIPS instrument and the resulting contrast performance. This study assumes wavefront aberrations based on a finite element model of a simulated telescope with spacecraft structural dynamics. Wavefront residuals are then computed according to a model of the adaptive optics system that includes numerical propagation to simulate a realistic wavefront sensor and an analytical model of the temporal performance. An end-to-end numerical propagation model of ECLIPS is then used to estimate the residual starlight intensity distribution at the science detector. We show that the contrast performance depends strongly on the target star magnitude and the spatio-temporal distribution of wavefront errors from the telescope. In cases with significant vibration, we advocate for the use of laser metrology to mitigate high temporal frequency wavefront errors and increase the mission yield.

Sirbu, Dan↗

Contrast variation in spin-echo small angle neutron scattering

The principle of using contrast variation spin-echo small angle neutron scattering (SESANS) technique for colloidal structural investigation is discussed. Based on the calculations of several model systems, we find that the contrast variation SESANS technique is not sensitive in detecting the structural characteristics of colloidal suspensions consisting of particles with uniform scattering length density profiles. However, its capability of resolving the structural heterogeneity, at both intra- and inter-colloidal length scales, is clearly demonstrated. The prospect of using this new technique to investigate the structural information that is difficult to be probed by other ways is also explored.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Practical method and device for enhancing pulse contrast ratio for lasers and electron accelerators

An apparatus and method for enhancing pulse contrast ratios for drive lasers and electron accelerators. The invention comprises a mechanical dual-shutter system wherein the shutters are placed sequentially in series in a laser beam path. Each shutter of the dual shutter system has an individually operated trigger for opening and closing the shutter. As the triggers are operated individually, the delay between opening and closing first shutter and opening and closing the second shutter is variable providing for variable differential time windows and enhancement of pulse contrast ratio.

42 ENGINEERING↗

High-contrast, convergent x-ray imaging with laser-Compton sources

Techniques are provided for the production of high-contrast, x-ray and/or gamma-ray radiographic images. The images have minimal contributions from object-dependent background radiation. The invention utilizes the low divergence, quasi-monoenergetic, x-ray or gamma-ray output from a laser-Compton source in combination with x-ray optical technologies to produce a converging x-ray or gamma-ray beam with which to produce a high-contrast, shadowgraph of a specific object. The object to be imaged is placed within the path of the converging beam between the x-ray optical assembly and the focus of the x-ray beam produced by that assembly. The beam is then passed through an optically thick pinhole located at the focus of the beam. Downstream of the pinhole, the inverted shadowgraph of the object is then recorded by an appropriate 2D detector array.

Barty, Christopher P. J.↗

Coded-mask-based X-ray phase-contrast and dark-field imaging

Phase contrast and dark-field X-ray imaging enable imaging of objects that absorb or reflect very little X-ray light. Disclosed is a method and systems for performing coded-mask-based multi-contrast imaging (CMMI). The method includes providing radiation to a coded mask that has a known phase and absorption profile according to a pre-determined pattern. The radiation is then impingent upon a sample, and the radiation is detected to perform phase-reconstruction and image processing. The method and associated systems allow for the use of maximum-likelihood and machine learning methods for reconstruction images of the sample from the detected radiation.

Shi, Xianbo↗

Improving Contrast and Resolution in Plant Root Imaging

Plants play a vital role in our agro-economy, serving as a food source for both humans and animals, as exploitable sources of 'green' energy, and carbon/nitrogen fixing organisms important for atmospheric health. Roots, often hidden from view, represent one of the major connections shared between plants and their environment. Enhancing our understanding of the process of root growth in the face of complex soil compositions, and abundances or shortages of both nutrients and available water, will enable researchers to develop or improve strategies to select on genetic traits that increase the likelihood of plant survival under stress. A major setback associated with the study of plant root structures in-situ has been the inability to view the root using standard optical methods. X-ray imaging has been used since the 1980's to produce images from 'simple' 2D attenuation contrast scans to 3D computed tomography generated volumes. A large majority of previous experimental analysis has been conducted with commercial x-ray systems designed for life-sciences and/or materials analysis applications. These commercial packages were never intended for use with targets composed mostly of inorganic materials resulting in information loss. We have investigated methods to optimize imaging contrast and resolution to help reveal the very small features of root systems embedded within varying soil substrates. (authors)

60 APPLIED LIFE SCIENCES↗

Quantitative In Situ Studies of Dynamic Fracture in Brittle Solids Using Dynamic X-ray Phase Contrast Imaging

Here, we demonstrate the use of X-ray phase contrast imaging with sub-microsecond temporal resolution to obtain quantitative visualization of dynamic fracture processes in brittle solids. We examine an amorphous solid (fused silica), a ceramic single crystal (single-crystal quartz), and a polycrystalline ceramic (boron carbide), in the form of single-edge notched specimens loaded using a three-point apparatus at nominal strain rates up to ~800 s -1 . We observe that the crack tip speed for boron carbide is relatively independent of mode I stress intensity factor rate ($\dot{K}$ I ) for these rates of loading, while that of fused silica and single-crystal quartz increases with $\dot{K}$ I . Further, for the amorphous and single crystal cases, we observe the development of a crack tip instability in the form of crack branching as the crack tip speed approaches 45% of the Rayleigh wave speed. This suggests that strain-rate-dependent mechanisms contribute to crack branching. Such mechanisms may, in turn, affect the macroscopic fracture properties of these materials.

36 MATERIALS SCIENCE↗

Detection of Type II Endoleak After Endovascular Aortic Repair: Comparison Between Magnetic Resonance Angiography and Blood-Pool Contrast Agent and Dual-Phase Computed Tomography Angiography

PurposeThis prospective study was designed to assess the diagnostic value of magnetic resonance angiography (MRA) with blood-pool contrast agent (gadofosveset) in the detection of type-II endoleak after endovascular aortic repair (EVAR).MethodsThirty-two patients with aortic aneurysms who had undergone EVAR were included in this study. All patients were examined by dual-phase computed tomography angiography (CTA) as well as MRA with gadofosveset in the first-pass and steady-state phases. Two independent readers evaluated the images of CTA and MRA in terms of endoleak type II, feeding vessel, and image quality.ResultsMedian follow-up-time after EVAR was 22 months (range 4 to 59). Endoleak type II was detected by CTA in 12 of 32 patients (37.5%); MRA detected endoleak in all of these patients as well as in another 9 patients (n = 21, 65.6%), of whom the endoleaks in 6 patients showed an increasing diameter. Most endoleaks were detected in the steady-state phase (n = 14). The decrease in diameter of the aneurysmal sac was significantly greater in the patients without a visible endoleak that was visible on MRA (P = 0.004). In the overall estimation of diagnostic accuracy, MRA was judged superior to CTA in 66% of all examinations.ConclusionMRA with gadofosveset appeared superior to CTA, and has higher diagnostic accuracy, in the detection of endoleak after EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗