Direct simulation Monte Carlo prediction of on-orbit contaminant deposit levels for HALOE

A three-dimensional version of the direct simulation Monte Carlo method is adapted to assess the contamination environment surrounding a highly detailed model of the Upper Atmosphere Research Satellite. Emphasis is placed on simulating a realistic, worst-case set of flow field and surface conditions and geometric orientations for the satellite in order to estimate an upper limit for the cumulative level of volatile organic molecular deposits at the aperture of the Halogen Occultation Experiment. A detailed description of the adaptation of this solution method to the study of the satellite's environment is also presented. Results pertaining to the satellite's environment are presented regarding contaminant cloud structure, cloud composition, and statistics of simulated molecules impinging on the target surface, along with data related to code performance. Using procedures developed in standard contamination analyses, along with many worst-case assumptions, the cumulative upper-limit level of volatile organic deposits on HALOE's aperture over the instrument's 35-month nominal data collection period is estimated at about 13,350 A.

Woronowicz, Michael S.↗

Prediction of particulate contamination on aperture window

This paper presents an analysis to predict the effects of light scattering by surface particles on the sensor window of a missile during ascent flight. The particulate contaminant distribution on the window is calculated by tallying the number of particles in a set of size ranges. The particulate contamination at the end of the mission is predicted by adding the contributions from the events of ground and flight operations. The surface particle redistributions caused by vibroacoustically induced surface acceleration was found to contribute the most of the particulate surface contamination. The analytical surface obscuration calculation with a set of particle counts was compared to the results of image analyzer measurement. The analytical results, which were calculated with a given function of particle shape depending on the size, were more conservative than the measurement. A scattering calculation using a verified BSDF model showed that the scattering was less than 0.001 at 20 off the direction of the incident light in the mid IR wavelength when the surfaces were at Level 300 initially.

Lee, Aleck L.↗

Using a temperature-controlled quartz crystal microbalance in a space equipment cleanroom to monitor molecular contamination

There is a need for continuous monitoring for molecular contamination in clean rooms where spaceflight equipment is assembled, integrated, and tested to insure that contamination budgets are met. The TQCM (temperature-controlled quartz crystal microbalance) can be used to provide both a real time warning and a cumulative measurement of molecular contamination. It has advantages over the other measurement methods such as witness mirrors, NVR (non-volatile residue) plates, and gas analyzers. A comparison of the TQCM sensitivity and ease of operations is made with the other methods. The surface acoustic wave microbalance (SAW), a newly developed instrument similar to TQCM, is considered in the comparison. An example is provided of TQCM use at Goddard Space Flight Center when the Wide Field Planetary Camera 2(WFPC-2) and the Corrective Optics Space Telescope Axial Replacement (COSTAR) were undergoing integrated testing prior to their installation in the Hubble Space Telescope on its first servicing mission. Areas for further investigation are presented.

Mitchell, William J.↗

Surface contamination analysis technology team overview

A team was established which consisted of representatives from NASA (Marshall Space Flight Center and Langley Research Center), Thiokol Corporation, the University of Alabama in Huntsville, AC Engineering, SAIC, Martin Marietta, and Aerojet. The team's purpose was to bring together the appropriate personnel to determine what surface inspection techniques were applicable to multiprogram bonding surface cleanliness inspection. In order to identify appropriate techniques and their sensitivity to various contaminant families, calibration standards were developed. Producing standards included development of consistent low level contamination application techniques. Oxidation was also considered for effect on inspection equipment response. Ellipsometry was used for oxidation characterization. Verification testing was then accomplished to show that selected inspection techniques could detect subject contaminants at levels found to be detrimental to critical bond systems of interest. Once feasibility of identified techniques was shown, selected techniques and instrumentation could then be incorporated into a multipurpose inspection head and integrated with a robot for critical surface inspection. Inspection techniques currently being evaluated include optically stimulated electron emission (OSEE); near infrared (NIR) spectroscopy utilizing fiber optics; Fourier transform infrared (FTIR) spectroscopy; and ultraviolet (UV) fluorescence. Current plans are to demonstrate an integrated system in MSFC's Productivity Enhancement Complex within five years from initiation of this effort in 1992 assuming appropriate funding levels are maintained. This paper gives an overview of work accomplished by the team and future plans.

Burns, H. Dewitt↗

Post-entry and volcanic contaminant abundances of zinc, copper, selenium, germanium and gallium in stratospheric micrometeorites

Some fraction of Zn, Cu, Se, Ga and Ge in chondritic interplanetary dust particles (IDPs) collected in the lower stratosphere between 1981 May and 1984 June has a volcanic origin. I present a method to evaluate the extent of this unavoidable type of stratospheric contamination for individual particles. The mass-normalized abundances for Cu and Ge as a function of mass-normalized stratospheric residence time show their time-integrated stratospheric aerosol abundances. The Zn, Se and Ga abundances show a subdivision into two groups that span approximately two-year periods following the eruptions of the Mount St. Helens (1980 May) and El Chichon (1982 April) volcanoes. Elemental abundances in particles collected at the end of each two-year period indicate low, but not necessarily ambient, volcanic stratospheric abundances. Using this time-integrated baseline, I calculate the straospheric contaminant fractions in nine IDPs and show that Zn, SE and Ga abundances in chondritic IDPs derive in part from stratospheric aerosol contaminants. Post-entry elemental abundances (i.e., the amount that survived atmospheric entry heating of the IDP) show enrichments relative to the CI abundances but in a smaller number of particles than previously suggested.

Rietmeijer, Frans J. M.↗

IR excitation of contaminant water by oxygen for the space shuttle at low Earth orbit altitude

As the water outgas of a space shuttle passes through the rarefied atmosphere at orbital altitude, collisions occur between the gases with sufficient energy to excite infrared-active water molecules to various vibrational and rotational states. An infrared contaminant model (IR model) has been developed to study the shuttle-induced excitation and emission of water molecules outgassed from the space shuttle. The focus of the first application of the model is translation-to-vibration (T-V) energy transfer since estimates suggest that this process should dominate the production of vibrationally excited H2O under typical low Earth orbit conditions. Using the velocity and position distribution functions of interacting neutral gases obtained from a neutral gases interaction model, the spatial distributions of excitation and IR radiation from contaminant water are computed, and typical results are presented. Infrared spectral data (450 - 2500/cm), measured by the Cryogenic Infrared Radiance Instrumentation for Shuttle (CIRRIS-1A) sensor on STS-39 (April 28 to May 6, 1991) at an altitude near 265 km, are used to test model predictions. The dependence of the radiant emission structure and brightness on outgassing rates and altitudes is discussed. The time history of the contaminant water outgassing rate is inferred for STS-39, and it is compared with the mass-spectrometer-based results for STS-4 (June 26 to July 4, 1982). Also, estimates of H2O column density at mission elapsed time (MET) 50 hours are compared for missions STS-2, STS-3, STS-4, and STS-39.

Zhou, D. K.↗

Pulsed Plasma Thruster Contamination

Pulsed Plasma Thrusters (PPT's) are currently baselined for the Air Force Mightysat II.1 flight in 1999 and are under consideration for a number of other missions for primary propulsion, precision positioning, and attitude control functions. In this work, PPT plumes were characterized to assess their contamination characteristics. Diagnostics included planar and cylindrical Langmuir probes and a large number of collimated quartz contamination sensors. Measurements were made using a LES 8/9 flight PPT at 0.24, 0.39, 0.55, and 1.2 m from the thruster, as well as in the backflow region behind the thruster. Plasma measurements revealed a peak centerline ion density and velocity of approx. 6 x 10(exp 12) cm(exp -3) and 42,000 m/s, respectively. Optical transmittance measurements of the quartz sensors after 2 x 10(exp 5) pulses showed a rapid decrease in plume contamination with increasing angle from the plume axis, with a barely measurable transmittance decrease in the ultraviolet at 90 deg. No change in optical properties was detected for sensors in the backflow region.

Myers, Roger M.↗

Rationale and Methods for Archival Sampling and Analysis of Atmospheric Trace Chemical Contaminants On Board Mir and Recommendations for the International Space Station

Collection and analysis of spacecraft cabin air samples are necessary to assess the cabin air quality with respect to crew health. Both toxicology and engineering disciplines work together to achieve an acceptably clean cabin atmosphere. Toxicology is concerned with limiting the risk to crew health from chemical sources, setting exposure limits, and analyzing air samples to determine how well these limits are met. Engineering provides the means for minimizing the contribution of the various contaminant generating sources by providing active contamination control equipment on board spacecraft and adhering to a rigorous material selection and control program during the design and construction of the spacecraft. A review of the rationale and objectives for sampling spacecraft cabin atmospheres is provided. The presently-available sampling equipment and methods are reviewed along with the analytical chemistry methods employed to determine trace contaminant concentrations. These methods are compared and assessed with respect to actual cabin air quality monitoring needs. Recommendations are presented with respect to the basic sampling program necessary to ensure an acceptably clean spacecraft cabin atmosphere. Also, rationale and recommendations for expanding the scope of the basic monitoring program are discussed.

Perry, J. L.↗

Performance Testing of a Russian Mir Space Station Trace Contaminant Control Assembly

A filter assembly which is incorporated into the Russian Trace Contaminant Control Assembly was tested for removal of airborne trace chemical contaminants in a closed loop 9 m(exp 3) system. Given contaminant loading rates and maximum allowable atmospheric concentrations, the Russian system was able to maintain system air concentrations below maximum allowable limits. This was achieved for both a new filter system and for a system where a part of it was pre-loaded to emulate 3 years of system age.

Curtis, R. E.↗

1997 Spacecraft Contamination and Coatings Workshop

This volume contains the presentation charts of talks given at the "1997 Spacecraft Contamination and Coatings Workshop," held July 9-10, 1997, in Annapolis, Maryland. The workshop was attended by representatives from NASA, Jet Propulsion Laboratory, Department of Defense, industry, and universities concerned with the the spacecraft contamination engineering and thermal control coatings. The workshop provided a forum for exchanging new developments in spacecraft contamination and coatings.

Chen, Philip T.↗

Use of Variable Angle Spectroscopic Ellipsometry in Order to Determine Contaminant Optical Properties

In order to measure contaminant levels found in the manufacture of the Redesigned Solid Rocket Motor (RSRM), optical properties of the contaminants are needed to develop standards for calibration purposes. Specific to our efforts is the determination of the complex index of refraction for a hydrocarbon mixture and a commercial methyl siloxane. Using ellipsometric measurements with multiple angles of incident and a range of wavelengths in the near infrared a determination of the index of refraction and the extinction coefficient were made for the contaminants. This paper will present the optical techniques and modeling approach used to determine these optical constants of the hydrocarbon mixture and the methyl siloxane studied.

Hughes, C.↗

Earth Observing System/Meteorological Satellite (EOS/METSAT). Advanced Microwave Sounding Unit-A (AMSU-A) Contamination Control Plan

This Contamination Control Plan is submitted in response the Contract Document requirements List (CDRL) 007 under contract NAS5-32314 for the Earth Observing System (EOS) Advanced Microwave Sounding Unit A (AMSU-A). In response to the CDRL instructions, this document defines the level of cleanliness and methods/procedures to be followed to achieve adequate cleanliness/contamination control, and defines the required approach to maintain cleanliness/contamination control through shipping, observatory integration, test, and flight. This plan is also applicable to the Meteorological Satellite (METSAT) except where requirements are identified as EOS-specific. This plan is based on two key factors: a. The EOS/METSAT AMSU-A Instruments are not highly contamination sensitive. b. Potential contamination of other EOS Instruments is a key concern as addressed in Section 9/0 of the Performance Assurance Requirements for EOS/METSAT Integrated Programs AMSU-A Instrument (MR) (NASA Specification S-480-79).

Fay, M.↗

Contamination Control Changes to the Reusable Solid Rocket Motor Program: A Ten Year Review

During the post Challenger period, the National Aeronautics and Space Administration and Thiokol implemented changes to the Reusable Solid Rocket Motor (RSRM) contract to include provisions for contamination control to enhance the production environment. During the ten years since those agreements for contamination controls were made, many changes have taken place in the production facilities at Thiokol. These changes have led to the production of much higher quality shuttle solid rocket motors and improved cleanliness and safety of operations in the production facilities. The experience in contamination control over this past decade highlights the value these changes have brought to the RSRM program, and how the system can be improved to meet the challenges the program will face in the next ten years.

Bushman, David M.↗

Calibration Results for the AXAF Flux Contamination Monitor

The Flux Contamination Monitor (FCM) on the Advanced X-ray Astrophysics Facility (AXAF) serves the purposes of transfering the absolute flux calibration from the ground calibration at the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center to operation on orbit and of detecting any changes in molecular contamination of the High Resolution Mirror Assembly (HRMA) between ground calibration and the post-launch activation phase. we describe the design, construction, and characterization of the FCM radioactive sources, and their placement on the Forward Contamination Cover (FCC). We present results from FCM measurements with the AXAF focal plane instruments, particularly the AXAF CCD Imaging Spectrometer (ACIS), during the ground calibration phase at XRCF in 1997. Finally, we describe the plans for FCM on-orbit measurements during observatory activation and the subsequent analysis.

Elsner, Ronald F.↗

Calibration Results for the AXAF Flux Contamination Monitor

The AXAF Flux Contamination Monitor (FCM) serves the purposes of transferring the absolute flux calibration from the ground calibration at the X-Ray Calibration Facility (XRCF) to operation on orbit and of detecting any changes in molecular contamination of the High-Resolution Mirror Assembly (HRMA) between ground calibration and the post-launch activation. We describe the design, construction, and characterization of the FCM radioactive sources, and their placement on the Forward Contamination Cover (FCC). We present results from FCM measurements with the AXAF focal-plane instruments, particularly the AXAF CCD Imaging Spectrometer (ACIS), during the ground calibration phase at the XRCF in 1997. Finally, we describe the plans for FCM on-orbit measurements during observatory activation and for the subsequent analysis.

Elsner, R. F.↗

Measurements with the Chandra Flight Contamination Monitor

NASA's Chandra X-ray Observatory includes a Flight Contamination Monitor (FCM), a system of 16 radioactive calibration sources mounted to the inside of the Observatory's forward contamination cover. The purpose of the FCM is to verify the ground-to-orbit transfer of the Chandra flux scale, through comparison of data acquired during the ground calibration with those obtained in orbit, immediately prior to opening the Observatory's sun-shade door. Here we report results of these measurements, which place limits on the change in mirror-detector system response and, hence, on any accumulation of molecular contamination on the mirrors' iridium-coated surfaces.

Elsner, R. E.↗

A Contaminant Ice Visualization Experiment in a Glass Pulse Tube

Results are presented from pulse tube experiments designed to investigate the effect of 400 parts per million water vapor contamination of the helium working gas. The experiments were conducted in a glass pulse tube to enable visualization of ice formation on internal surfaces. Photographs of this ice formation were taken along with simultaneous coldtip temperature and compressor power measurements. Four types of regenerator elements were tested in various combinations: 200- and 400-mesh stainless steel screens, 1.6 mm diameter glass beads, and 1.6 mm thick perforated plastic plates. Internal spacers were also used to provide clear fields of view into the regenerator stack. Substantial water-ice formation was observed at the cold end of the regenerator and on the inside wall of pulse tube; it appeared to be highly porous, like snow, and was seen to accumulate only in a very localized region at the coldest end, despite changing the cold tip temperature across a range of 150 to 235 K. Ice formation degraded pulse tube thermal performance only in cases where screen regenerators were used at the regenerator cold end. It was concluded that flow blockage was the mechanism by which contaminants affected performance; coarse regenerator elements were largely immune over the tested time scale of a few days. Substantially reduced ice formation and minimal performance loss were also observed in repeated tests where the contaminated gas was reused after warming up and melting of the accumulated internal ice. Significant adsorption of the liquid water onto the regenerator was inferred, a process that depleted the gas phase concentration of water.

Hall, J. L.↗

Hall Effect Thruster Plume Contamination and Erosion Study

The objective of the Hall effect thruster plume contamination and erosion study was to evaluate the impact of a xenon ion plume on various samples placed in the vicinity of a Hall effect thruster for a continuous 100 hour exposure. NASA Glenn Research Center was responsible for the pre- and post-test evaluation of three sample types placed around the thruster: solar cell cover glass, RTV silicone, and Kapton(R). Mass and profilometer), were used to identify the degree of deposition and/or erosion on the solar cell cover glass, RTV silicone, and Kapton@ samples. Transmittance, reflectance, solar absorptance, and room temperature emittance were used to identify the degree of performance degradation of the solar cell cover glass samples alone. Auger spectroscopy was used to identify the chemical constituents found on the surface of the exposed solar cell cover glass samples. Chemical analysis indicated some boron nitride contamination on the samples, from boron nitride insulators used in the body of the thruster. However, erosion outweighted contamination. All samples exhibited some degree of erosion. with the most erosion occurring near the centerline of the plume and the least occurring at the +/- 90 deg positions. For the solar cell cover glass samples, erosion progressed through the antireflective coating and into the microsheet glass itself. Erosion occurred in the solar cell cover glass, RTV silicone and Kapton(R) at different rates. All optical properties changed with the degree of erosion, with solar absorptance and room temperature emittance increasing with erosion. The transmittance of some samples decreased while the reflectance of some samples increased and others decreased. All results are consistent with an energetic plume of xenon ions serving as a source for erosion.