Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “condensation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Polyubiquitin ligand-induced phase transitions are optimized by spacing between ubiquitin units

Biomolecular condensates form via multivalent interactions among key macromolecules and are regulated through ligand binding and/or posttranslational modifications. One such modification is ubiquitination, the covalent addition of ubiquitin (Ub) or polyubiquitin chains to target macromolecules. Specific interactions between polyubiquitin chains and partner proteins, including hHR23B, NEMO, and UBQLN2, regulate condensate assembly or disassembly. Here, we used a library of designed polyubiquitin hubs and UBQLN2 as model systems for determining the driving forces of ligand-mediated phase transitions. Perturbations to either the UBQLN2-binding surface of Ub or the spacing between Ub units reduce the ability of hubs to modulate UBQLN2 phase behavior. By developing an analytical model based on polyphasic linkage principles that accurately described the effects of different hubs on UBQLN2 phase separation, we determined that introduction of Ub to UBQLN2 condensates incurs a significant inclusion energetic penalty. This penalty antagonizes the ability of polyUb hubs to scaffold multiple UBQLN2 molecules and cooperatively amplify phase separation. The extent to which polyubiquitin hubs promote UBQLN2 phase separation is encoded in the spacings between Ub units. This spacing is modulated by chains of different linkages and designed chains of different architectures, thus illustrating how the ubiquitin code regulates functionality via the emergent properties of the condensate. The spacing in naturally occurring linear polyubiquitin chains is already optimized to promote phase separation with UBQLN2. We expect our findings to extend to other condensates, emphasizing the importance of ligand properties, including concentration, valency, affinity, and spacing between binding sites in studies and designs of condensates.

97 MATHEMATICS AND COMPUTING↗

Understanding the Role of Populus ECERIFERUM2-Likes in the Biosynthesis of Very-Long-Chain Fatty Acids for Cuticular Waxes

Cuticular waxes are derived from very-long-chain fatty acid (VLCFA) precursors made by the concerted action of four enzymes that form the fatty acid (FA) elongation complex. Here, the condensing enzyme of the complex confers specificity to substrates of different chain lengths, yet on its own cannot account for the biosynthesis of VLCFAs longer than 28 carbons (C28). Recent evidence from Arabidopsis thaliana points to a synergistic role of clade II BAHD acyltransferases and condensing enzymes in the elongation of VLCFAs beyond C28. In Populus trichocarpa, clade II is composed of seven uncharacterized paralogous genes (PtCER2-like1–7). In the present study, five of these genes were heterologously expressed in yeast and their respective FA profiles were determined. PtCER2-likes differentially altered the accumulation of C28 and C30 FAs when expressed in the presence of the condensing enzyme AtCER6. Among these, PtCER2-like5 produced the highest levels of C28 FAs in yeast and its expression was localized to the epidermis in β-glucuronidase-reporter poplar lines, consistent with a role in cuticular wax biosynthesis. Complementation of the A. thaliana cer2-5 mutant with PtCER2-like5 increased the levels of C28-derived cuticular waxes at the expense of C30-derived components. Together, these results demonstrate that the role of CER2-likes in cuticular wax biosynthesis is conserved in Populus clade II BAHD acyltransferases.

59 BASIC BIOLOGICAL SCIENCES↗

Generalized Lapse Rate Formulas for Use in Entraining CAPE Calculations

Abstract Common assumptions in temperature lapse rate formulas for lifted air parcels include neglecting mixing, hydrostatic balance, the removal of all condensate once it forms (pseudoadiabatic), and/or the retention of all condensate within the parcel (adiabatic). These formulas are commonly derived from the conservation of entropy, which leads to errors when nonequilibrium mixed-phase condensate is present. To evaluate these assumptions, a new general lapse rate formula is derived from an expression for energy conservation, rather than entropy conservation. This new formula incorporates mixing of the parcel with its surroundings, relaxes the hydrostatic assumption, allows for nonequilibrium mixed-phase condensate, and can be formulated for pseudoadiabatic or adiabatic ascent. The new formula is shown to exactly conserve entropy for reversible ascent. Predictions by the new formula are compared to that of older and less general formulas. The errors in previous formulas arise from the assumption of hydrostatic balance, which results in considerable warm biases due to the neglect of the energy sink from buoyancy. Predictions of ascent with entrainment using the new formula are then compared to parcel properties along trajectories in large eddy simulations. Simulated parcel properties are better predicted by the formula using a diluted analogy to adiabatic ascent, wherein condensate is diluted at the same rate as other parcel properties, than by the diluted analogy to pseudoadiabatic ascent, wherein all condensate is removed. These results suggest that CAPE should be computed with adiabatic, rather than pseudoadiabatic, parcel ascent.

54 ENVIRONMENTAL SCIENCES↗

NUMERICAL INVESTIGATION OF AIR DEHUMIDIFICATION THROUGH WATER DROPLETS DIELECTROPHORESIS

This paper numerically investigated the dehumidification of moist airflow in a converging rectangular duct with electrically enhanced condensation. The aim was to develop a condensation model that predicted water vapor condensation by employing the dielectrophoresis principle. The charged droplets were injected into the computational domain to produce a gradient electric field. The dielectrophoretic interaction between the droplets and vapor molecules of the humid air resulted in local water vapor condensation at the vapor and liquid droplet interface. This phenomenon is described in detail in this paper. A hybrid Eulerian-Lagrangian solver SprayFoam was developed based on OpenFOAM® to simulate condensation in two-phase gas-liquid mixtures. The following developments were made based on the standard compressible multiphase flow solver SprayFoam in OpenFOAM®: (1) Eulerian solver for gas phase (2) multi-component species transport, and (3) Lagrangian solver for gas-droplet two-phase flows and sub-models for liquid droplets. The newly developed numerical model was experimentally validated with data from a series of tests conducted in the authors' laboratory. The results showed that the simulations followed the same trends as the data, and the model predicted the condensation due to the electro-spray injection process in the air stream. The injected water droplets, which are electrically charged to their Rayleigh limits, increased in size while wiping out the humidity from the air. The simulations indicated that the dehumidification was about 1% for 0.5 cubic feet per minute airflow rate. Scaling up to larger flows is a future follow-up work.

Yel Mahi, *Maliha↗

Numerical case study of the aerosol–cloud interactions in warm boundary layer clouds over the eastern North Atlantic with an interactive chemistry module

The presence of warm boundary layer stratiform clouds over the eastern North Atlantic (ENA) region is commonly influenced by the Azores High, especially during the summer season. To investigate comprehensive aerosol–cloud interactions, this study employs the Weather Research and Forecasting model coupled with a chemistry component (WRF-Chem), incorporating aerosol chemical components that are relevant to the formation of cloud condensation nuclei (CCN) and accounting for aerosol spatiotemporal variation. This study focuses on aerosol indirect effects, particularly the long-range transport of aerosols, in the ENA region under three different weather regimes: a ridge with a surface high-pressure system, a post-trough with a surface high-pressure system, and a weak trough. The WRF-Chem simulations conducted at a near-large-eddy scale offer valuable insights into the model's performance, especially in terms of its ability to use high spatial resolution to capture mesoscale cloud features across various weather regimes. Our result shows that introducing 5 times more aerosols to either non-precipitating or precipitating clouds significantly increases ambient CCN numbers, resulting in, to varying degrees, higher liquid water path (LWP) values. The substantial aerosol–cloud interaction especially occurs in the precipitating clouds and demonstrates the susceptibility of the LWP to changes in CCN under different regimes. Conversely, thin, non-rain clouds at the edges of a cloud system are prone to evaporation, exhibiting an aerosol drying effect. The aerosols released during this process transition back to the accumulation mode, facilitating future activation. This dynamic behavior is not adequately represented in prescribed-aerosol simulations.

54 ENVIRONMENTAL SCIENCES↗

Pyrolysis Vapor and Bio-Oil Preconditioning via Ex Situ Hydrodeoxygenation and Alkylation Using a Heteropolyacid Catalyst

Ex situ catalytic preconditioning of biomass pyrolysis vapors (partial deoxygenation) has the potential for both reducing the oxygen content and beneficially influencing the oxygen speciation of condense bio-oils for enhancement of downstream condensed phase upgrading processes. Here, condensed phase upgrading processes may refer to both coprocessing and hydroprocessing with vacuum gas-oil (VGO). Reduction of oxygen content to produce bio-oils with greater hydrophobicity can enhance VGO-solubility while tailoring of oxygen speciation by removal of reactive carbonyls (e.g., acetic acid) can lessen catalytic deactivation via coking reactions. 1,2 Furthermore, enhanced VGO-solubility and reduced coking leads to greater biogenic carbon incorporation in end-products from condensed phase upgrading processes. By leveraging the hydrodeoxygenation and alkylation activity of a titania-supported molybdenum-heteropolyacid (Mo-HPA/TiO2) catalyst, pyrolysis vapors and resulting condensed bio-oils were effectively preconditioned for downstream upgrading. 3 Data regarding the use of Mo-HPA/TiO2 for pyrolysis vapor preconditioning will be presented on, including method of employment, catalyst characterization, and impacts on bio-oil in relation to downstream condensed phase upgrading processes. Our approach is to: Compare Mo-HPA/TiO2 product distribution to HZSM-5; Investigate Mo-HPA/TiO2 regeneration and characterize changes in acid site character; Assess product differences in terms of enhanced VGO-solubility.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Method of separating components of a gas

The disclosure provides a method for separating components of a gas. A feed gas stream is cooled in a first vessel. The feed gas stream includes methane, water, carbon dioxide, and Natural Gas Liquids. The feed gas stream is cooled in a first vessel. A portion of the water condenses to form a primary liquid stream, resulting in a first depleted gas stream, which is cooled in a second vessel. A portion of the NGLs condense to form a secondary liquid stream, resulting in a second depleted gas stream, which is cooled in a condensing exchanger. A first portion of the methane condenses to form a liquid methane stream, resulting in a third depleted gas stream, which is cooled in a third vessel. A portion of the carbon dioxide condenses, desublimates, or condenses and desublimates as a final product stream, also resulting in a fourth depleted gas stream.

Baxter, Larry↗

System and method of water purification utilizing an ionomer membrane

A water purification system utilizes an ionomer membrane and mild vacuum to draw water from source water through the membrane. A water source may be salt water or a contaminated water source. The water drawn through the membrane passes across the condenser chamber to a condenser surface where it is condensed into purified water. The condenser surface may be metal or any other suitable surface and may be flat or pleated. In addition, the condenser surface may be maintained at a lower temperature than the water on the water source side of the membrane. The ionomer membrane may be configured in a cartridge, a pleated or flat plate configuration. A latent heat loop may be configured to carry the latent heat of vaporization from the condenser back to the water source side of the ionomer membrane. The source water may be heated by a solar water heater.

Bahar, Bamdad↗

Lightweight inorganic membrane module

An apparatus and system for separating a liquid from a mixed gas stream includes a porous graphite foam support comprising graphite foam with pores having a first pore size and a membrane support surface. A porous condensation membrane layer is provided on the membrane support surface, and interlocked with the pores of the graphite foam. The condensation membrane layer includes capillary condensation pores having a second pore size that is less than the first pore size. A mixed gas stream passageway is in fluid communication with the condensation membrane layer. A liquid collection assembly collects condensed liquid from the condensation pores and the graphite foam support pores. A gas inlet is provided for flowing the mixed gas stream into the mixed gas stream passageway. A gas outlet is provided for exhausting gas from the mixed gas stream passageway. A method for separating a liquid from a mixed gas stream is also disclosed.

36 MATERIALS SCIENCE↗

Thermodynamic Model and Initial Experimental Investigation of Air Dehumidification through Electrically Charged Vapor Capturing Electrostatic Droplets

The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.

Morcelli, Stefano↗

Sockeye Code Validation Against UNIST Heat Pipe - Poster - Internship 2025

Sockeye is an engineering level code being developed under the MOOSE framework for modeling heat pipes. A heat pipe is a sealed tube with a wick structure filled with a working fluid that transfers heat efficiently and passively via phase change of the working fluid. Heat applied to the evaporator end creates a pressure gradient which causes vapor to migrate to the condenser end where the vapor deposits its energy and condenses. Capillary force generated by the wick structure then draws the liquid back to the evaporator. A validation study was performed to compare the Sockeye code against data produced at the Ulsan National Institute of Standards and Technology for a slightly overfilled sodium heat pipe. The heat pipe was operated under natural convection cooling and a decreasing inactive length was observed. The experiment was modeled in Sockeye using the condenser pool model, the front non-condensable gas (NCG) model, and the mixture NCG model separately to reproduce the inactive length phenomenon. Also, a new capability was implemented in MOOSE to allow for conjugate heat transfer from the condenser based on the Churchill-Chu correlation for natural convection. The condenser pool model showed an increasing inactive length, demonstrating that the behavior was likely not caused by a pool of excess liquid. The front NCG model was able to show good agreement with the experiment, but it suffered convergence issues at the front. Finally, the mixture NCG model gave good results when the axial mesh was sufficiently refined. This work culminated in additions to the Sockeye documentation and a contribution to a journal article that will be published later. This poster is a summary of my work which I can take back to my university for presentation.

42 - ENGINEERING↗

Overall chilled water system energy consumption modeling and optimization

The emergence of increasingly affordable variable-speed drive technology has changed the approach used to control chilled water systems equipped with these drives. The purpose of this research was to develop an integrated chilled water modeling technique that can determine the optimal system setpoints and estimate the energy saving potential of chiller system. The chiller system equipped with Variable Frequency Drives (VFDs) on cooling tower fans and condenser water pumps. To accomplish the objective, physical component models of the centrifugal chiller, cooling tower and condenser water pump were established with the goal of incorporating the system’s condenser water flow rate and cooling tower fan speeds as optimization variables. Furthermore, a cooling load prediction algorithm was developed using a multiple non-linear regression model to approximate the building’s cooling load subject to a range of environmental conditions. The inputs and outputs of the individual component models were linked to estimate how adjusting the cooling tower fan and condenser water pump speed would influence the system’s comprehensive performance. Here, the overall system model was then optimized using a generalized reduced gradient optimization algorithm to determine the potential energy savings through speed control with VFDs and to ascertain a control logic strategy for the building automation system to operate the heating and cooling system. A case-study was performed on a single chiller system at a museum and the model was calibrated according to logged data collected over four months. Results showed that for the system analyzed, the energy saving of optimizing the cooling tower fan system was found to be 12–15%, while the energy saving potential of optimizing the condenser water pump with the cooling tower fan was negligible. Additionally, comparing different cooling tower fan control strategies showed that a wet-bulb approach-based cooling tower control strategy was shown to have the highest correlation to the optimized fan speed with an R 2 of 0.924.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A tailored deep eutectic solvent for high-yield conversion of poplar residues to bio-based building blocks at mild conditions

The generation of condensed compounds in a deep eutectic solvent (DES) pretreatment has become a paramount factor that inhibits the further conversion of pretreated cellulose-rich substrate. Here, this study proposed a novel three-constituent DES system for the value-added utilization of poplar residues by efficiently suppressing hemicellulose derived condensation reactions. The results showed that adding ethanol into the DES system could effectively deconstruct the recalcitrant structure of poplar residues, simultaneously hindering the condensed composition formation. Under optimum ethanol addition (30%), the maximum xylan and lignin removal of 87.94% and 90.99% could be achieved, with more than 90.47% of glucan being preserved. With this, the glucan enzymatic hydrolysis efficiency was remarkably improved to 100% under the pretreatment conditions of 100 °C for 60 min, which was 84.69 times higher than the regular DES-pretreated poplar residues (1.17%). The working mechanism of relieving condensation reactions was characterized by Py-GC–MS, NMR, SEM, FTIR, and others. The results demonstrated that the addition of ethanol could regulate the degradation/conversion pathway of hemicellulose and lignin precipitation, thus inhibit the formation of condensed compounds during the pretreatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Falling-film thermosyphons: Application to water harvesting from humid gas streams

Water harvesting from humid gas streams is central to fresh-water production, desalination, and particulate removal from combustion gas streams. Two-phase thermosyphons are well suited for these applications due to their very low thermal resistance, but have several operating limits at the high heat flows required for such applications. This work introduces the falling-film thermosyphon for large-scale condensation applications. Working fluid is pumped to the top of the evaporator to provide the evaporating liquid film on the inner tube wall, rather than by vapor condensation. The flooding, dry-out and pool-boiling limits are eliminated, resulting in significantly higher maximum heat fluxes for the same physical evaporator size. Furthermore, the condenser no longer needs to be located vertically above the evaporator, which allows for a standard steam condenser to be used. A model for the condensation process in humid air was developed that estimates the fluid and heat transfer and is confirmed experimentally. Further benefits include the use of a high-thermal-conductivity polymer material for the evaporator section to minimize corrosion, and the ability to impose a temperature boundary condition on the evaporator, which is made possible due to the elimination of a liquid pool.

42 ENGINEERING↗

Two-Phase Cooling for High Packaging Density Planar Inverter: Cooperative Research and Development Final Report, CRADA Number CRD-15-00592

The project objective was to utilize two-phase heat transfer to enable compact and power-dense inverters. The high heat transfer capacity and near isothermal characteristics of two-phase cooling can enable higher power densities, reducing the size and cost of the power electronics system. This project focused on developing efficient, passive (no pump or compressor) two-phase cooling strategies that consist of an air-cooled condenser and evaporator. This report describes the modeling work conducted to design the evaporator and air-cooled condenser for a prototype inverter development work underway in the John Deere. Prototypes of the final evaporator and condenser designs were then fabricated via 3D printing for testing. Experiments on the evaporator confirmed that this component can meet the heat load and junction temperatures requirements for Si IGBT (insulated-gate bipolar transistor) inverter. Experiments with the air-cooled condenser were not possible due to leaks through the condenser walls.

33 ADVANCED PROPULSION SYSTEMS↗

Explicit soft supersymmetry breaking in the heterotic M-theory B - L MSSM

The strongly coupled heterotic M-theory vacuum for both the observable and hidden sectors of the B - L MSSM theory is reviewed, including a discussion of the “bundle” constraints that both the observable sector SU(4) vector bundle and the hidden sector bundle induced from a single line bundle must satisfy. Gaugino condensation is then introduced within this context, and the hidden sector bundles that exhibit gaugino condensation are presented. The condensation scale is computed, singling out one line bundle whose associated condensation scale is low enough to be compatible with the energy scales available at the LHC. The corresponding region of Kähler moduli space where all bundle constraints are satisfied is presented. The generic form of the moduli dependent F-terms due to a gaugino superpotential — which spontaneously break N = 1 supersymmetry in this sector — is presented and then given explicitly for the unique line bundle associated with the low condensation scale. The moduli-dependent coefficients for each of the gaugino and scalar field soft supersymmetry breaking terms are computed leading to a low-energy effective Lagrangian for the observable sector matter fields. We then show that at a large number of points in Kähler moduli space that satisfy all “bundle” constraints, these coefficients are initial conditions for the renormalization group equations which, at low energy, lead to completely realistic physics satisfying all phenomenological constraints. Finally, we show that a substantial number of these initial points also satisfy a final constraint arising from the quadratic Higgs-Higgs conjugate soft supersymmetry breaking term.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Relationships between Cloud Droplet Spectral Relative Dispersion and Entrainment Rate and Their Impacting Factors

Cloud microphysical properties are significantly affected by entrainment and mixing processes. However, it is unclear how the entrainment rate affects the relative dispersion of cloud droplet size distribution. Previously, the relationship between relative dispersion and entrainment rate was found to be positive or negative. To reconcile the contrasting relationships, the Explicit Mixing Parcel Model is used to determine the underlying mechanisms. When evaporation is dominated by small droplets, and the entrained environmental air is further saturated during mixing, the relationship is negative. However, when the evaporation of big droplets is dominant, the relationship is positive. Whether or not the cloud condensation nuclei are considered in the entrained environmental air is a key factor as condensation on the entrained condensation nuclei is the main source of small droplets. However, if cloud condensation nuclei are not entrained, the relationship is positive. If cloud condensation nuclei are entrained, the relationship is dependent on many other factors. High vertical velocity, relative humidity of environmental air, liquid water content, and low droplet number concentration are more likely to cause the negative relationship since new saturation is easier to achieve by evaporation of small droplets. Further, the signs of the relationship are not strongly affected by the turbulence dissipation rate, but the higher dissipation rate causes the positive relationship more significant for a larger entrainment rate. A conceptual model is proposed to reconcile the contrasting relationships. This work enhances the understanding of relative dispersion and lays a foundation for the quantification of entrainment-mixing mechanisms.

54 ENVIRONMENTAL SCIENCES↗

Dramatic Slowdown of Bimolecular Reactions of Criegee Intermediates in Organic Aerosols

Although Criegee intermediates (CIs) play a central role in driving the transformation of organic molecules, their condensed-phase reaction kinetics remains poorly understood. While CIs undergo unimolecular decomposition to produce OH radicals, stabilized CIs participate in a host of other bimolecular reactions forming larger molecular weight products, including secondary ozonides (kSOZ), alkoxyalkyl hydroperoxides (kAlAHP), and acyloxyalkyl hydroperoxides (kAcAHP). Here, we demonstrate, using prior literature and new measurements of heterogeneous organic aerosol reactions using O3 or OH radicals, that these condensed-phase bimolecular reaction rate coefficients kSOZ (10-20 cm3·molecule-1·s-1), kAlAHP, and kAcAHP (10-19 cm3·molecule-1·s-1) are 7-10 orders of magnitude slower than analogous gas-phase reactions (∼ 10-10-10-13 cm3·molecule-1·s-1). This contrasts with current evidence that the rate coefficients for unimolecular steps in the condensed phase are similar in magnitude to those in the gas phase. Kinetic models using gas-phase-like bimolecular coefficients consistently overestimate the importance of bimolecular relative to unimolecular pathways while underpredicting the aerosol reactivity by up to 30-fold. The slowing of bimolecular reactivity in aerosols is likely due to solvation effects and the increased steric hindrance of larger molecular weight CIs and their scavengers in the condensed phase. These results challenge the conventional view that the high reactant density of an organic aerosol should favor bimolecular over unimolecular reactions, underscoring the need for more accurate CI condensed-phase rate constants for reliable modeling of oxidative processes across a diverse set of atmospheric and environmental systems.

Zeng, Meirong↗