Laser space debris cleaning: elimination of detrimental self-focusing effects

A ground-based laser system for space debris cleaning requires pulse power well above the critical power for self-focusing in the atmosphere. Self-focusing results in beam quality degradation and is detrimental for the system operation. We demonstrate that, for the relevant laser parameters, when the thickness of the atmosphere is much less than the focusing length (that is, of the orbit scale), the beam transit through the atmosphere produces the phase distortion only. The model thus developed is in very good agreement with numerical modeling. This implies that, by using phase mask or adaptive optics, it may be possible to eliminate almost completely the impact of self-focusing effects in the atmosphere on the laser beam propagation.

47 OTHER INSTRUMENTATION↗

Fiber laser cleaning of metal mirror surfaces for optical diagnostic systems of the ITER

The results of experimental studies into efficiency of removal of films with a complex composition from metal mirrors by pulsed fiber laser irradiation are presented. It is shown that the initial reflectivity of optical elements can be restored by the selection of modes of irradiation impacting the surface with the sputtered film. Effective cleaning is performed by radiation with a power density lower than 10{sup 7} W/cm{sup 2}. The removal of contaminations at such a relatively low power density occurs in a solid phase, owing to which the thermal effect on the mirror is insignificant.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Estimation of Qualitative and Quantitative Parameters of Air Cleaning by a Pulsed Corona Discharge Using Multicomponent Standard Mixtures

The efficiency of removal of volatile organic impurities in air by a pulsed corona discharge is investigated using model mixtures. Based on the method of competing reactions, an approach to estimating the qualitative and quantitative parameters of the employed electrophysical technique is proposed. The concept of the “toluene coefficient” characterizing the relative reactivity of a component as compared to toluene is introduced. It is proposed that the energy efficiency of the electrophysical method be estimated using the concept of diversified yield of the removal process. Such an approach makes it possible to substantially intensify the determination of energy parameters of removal of impurities and can also serve as a criterion for estimating the effectiveness of various methods in which a nonequilibrium plasma is used for air cleaning from volatile impurities.

54 ENVIRONMENTAL SCIENCES↗

Clean Energy Application Centers: Annual Metrics Report for Fiscal Year 2012

Between fiscal year (FY) 2010 and 2013, the U.S. Department of Energy (DOE) funded nine Clean Energy Application Centers (CEACs) with national coverage to promote and assist in transforming the market for Combined Heat and Power (CHP), Waste Heat to Power CHP, and district energy (DE) with CHP1. Prior to that, similar services were provided by eight Regional Application Centers (RACs). The key services that the CEACs provided were market assessments, education and outreach, and technical assistance. There were eight regional CEACs, each of which served a specific area of the country, and a separate center operated by the International District Energy Association (IDEA) which supported the regional centers with technical assistance, education, training, publicity, and outreach related to district energy with CHP. Oak Ridge National Laboratory (ORNL) has performed four previous studies of CEAC activities. The first one examined what the centers had done each year from the initiation of the program through FY 2008; the second addressed center activities for FY 2009; the third one focused on what was accomplished in FY 2010; and the fourth looked at the CEACs’ FY 2011 accomplishments, with a heightened emphasis on the adoption of CHP\DE technologies and the activities thought to be most closely related to CHP/DE development and use. The most recent study, documented in this report, examines CEAC activities in FY 2012.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clean Cities Now: Vol. 18, No. 1, Spring 2014 (Newsletter)

Spring 2014 edition of the biannual newsletter of the U.S. Department of Energy's Clean Cities program. Each issue contains program news, success stories, and information about tools and resources to assist in the deployment of alternative fuels, advanced vehicles, idle reduction, fuel efficiency improvements, and other measures to cut petroleum use in transportation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing an Online Database of National and Sub-National Clean Energy Policies

The Database of State Incentives for Renewables and Efficiency (DSIRE) was established in 1995 to provide summaries of energy efficiency and renewable energy policies offered by the federal and state governments. This primer provides an overview of the major policy, research, and technical topics to be considered when creating a similar clean energy policy database and website.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Clean Cities 2013 Annual Metrics Report

Each year, the U.S. Department of Energy asks its Clean Cities program coordinators to submit annual reports of their activities and accomplishments for the previous calendar year. Data and information are submitted via an online database that is maintained as part of the Alternative Fuels Data Center (AFDC) at the National Renewable Energy Laboratory (NREL). Coordinators submit a range of data that characterize the membership, funding, projects, and activities of their coalitions. They also submit data about sales of alternative fuels, deployment of alternative fuel vehicles (AFVs) and hybrid electric vehicles (HEVs), idle-reduction (IR) initiatives, fuel economy activities, and programs to reduce vehicle miles traveled (VMT). NREL analyzes the data and translates them into petroleum-use reduction impacts, which are summarized in this 2013 Annual Metrics Report.

2013 DATA↗

Clean Cities 2014 Annual Metrics Report

Each year, the U.S. Department of Energy asks its Clean Cities program coordinators to submit annual reports of their activities and accomplishments for the previous calendar year. Data and information are submitted via an online database that is maintained as part of the Alternative Fuels Data Center (AFDC) at the National Renewable Energy Laboratory (NREL). Coordinators submit a range of data that characterize the membership, funding, projects, and activities of their coalitions. They also submit data about sales of alternative fuels, deployment of alternative fuel vehicles (AFVs) and hybrid electric vehicles (HEVs), idle-reduction (IR) initiatives, fuel economy activities, and programs to reduce vehicle miles traveled (VMT). NREL analyzes the data and translates them into petroleum-use reduction impacts, which are summarized in this 2014 Annual Metrics Report.

2014 data↗

Financial Incentives to Enable Clean Energy Deployment: Policy Overview and Good Practices

Financial incentives have been widely implemented by governments around the world to support scaled up deployment of renewable energy and energy efficiency technologies and practices. As of 2015, at least 48 countries have adopted financial incentives to support renewable energy and energy efficiency deployment. Broader clean energy strategies and plans provide a crucial foundation for financial incentives that often complement regulatory policies such as renewable energy targets, standards, and other mandates. This policy brief provides a primer on key financial incentive design elements, lessons from different country experiences, and curated support resources for more detailed and country-specific financial incentive design information.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Corrective Action Investigation Plan for Corrective Action Unit 413: Clean Slate II Plutonium Dispersion (TTR) Tonopah Test Range, Nevada (Rev. 1)

Corrective Action Unit (CAU) 413 is located on the Tonopah Test Range, which is approximately 130 miles northwest of Las Vegas, Nevada, and approximately 40 miles southeast of Tonopah, Nevada. The CAU 413 site consists of the release of radionuclides to the surface and shallow subsurface from the conduct of the Clean Slate II (CSII) storage–transportation test conducted on May 31, 1963. CAU 413 includes one corrective action site (CAS), TA-23-02CS (Pu Contaminated Soil). The known releases at CAU 413 are the result of the atmospheric deposition of contamination from the 1963 CSII test. The CSII test was a non-nuclear detonation of a nuclear device located inside a reinforced concrete bunker covered with 2 feet of soil. This test dispersed radionuclides, primarily plutonium, on the ground surface. The presence and nature of contamination at CAU 413 will be evaluated based on information collected from a corrective action investigation (CAI). The investigation is based on the data quality objectives (DQOs) developed on June 17, 2015, by representatives of the Nevada Division of Environmental Protection; the U.S. Air Force; and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 413. The CAI will include radiological surveys, geophysical surveys, collection and analyses of soil samples, and assessment of investigation results. The collection of soil samples will be accomplished using both probabilistic and judgmental sampling approaches. To facilitate site investigation and the evaluation of DQO decisions, the releases at CAU 413 have been divided into seven study groups.

54 ENVIRONMENTAL SCIENCES↗

Corrective Action Investigation Plan for Corrective Action Unit 414: Clean Slate III Plutonium Dispersion (TTR) Tonopah Test Range, Nevada, Revision 1

Corrective Action Unit (CAU) 414 is located on the Tonopah Test Range, which is approximately 130 miles northwest of Las Vegas, Nevada, and approximately 40 miles southeast of Tonopah, Nevada. The CAU 414 site consists of the release of radionuclides to the surface and shallow subsurface from the conduct of the Clean Slate III (CSIII) storage–transportation test conducted on June 9, 1963. CAU 414 includes one corrective action site (CAS), TA-23-03CS (Pu Contaminated Soil). The known releases at CAU 414 are the result of the atmospheric dispersal of contamination from the 1963 CSIII test. The CSIII test was a nonnuclear detonation of a nuclear device located inside a reinforced concrete bunker covered with 8 feet of soil. This test dispersed radionuclides, primarily uranium and plutonium, on the ground surface. The presence and nature of contamination at CAU 414 will be evaluated based on information collected from a corrective action investigation (CAI). The investigation is based on the data quality objectives (DQOs) developed on June 7, 2016, by representatives of the Nevada Division of Environmental Protection; the U.S. Air Force; and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective action alternatives for CAU 414.

54 ENVIRONMENTAL SCIENCES↗

Prototype Development and Evaluation of Self-Cleaning Concentrated Solar Power Collectors

The feasibility of integrating and retrofitting transparent electrodynamic screens (EDS) on the front surfaces of solar collectors was established as a means to provide active self-cleaning properties for parabolic trough and heliostat reflectors, solar panels, and Fresnel lenses. Prototype EDS-integrated solar collectors, including second-surface glass mirrors, metallized Acrylic-film mirrors, and dielectric mirrors, were produced and tested in environmental test chambers for removing the dust layer deposited on the front surface of the mirrors. The evaluation of the prototype EDS-integrated mirrors was conducted using dust and environmental conditions that simulate the field conditions of the Mojave Desert. Test results showed that the specular reflectivity of the mirrors could be maintained at over 90% over a wide range of dust loadings ranging from 0 to 10 g/m 2 , with particle diameter varying from 1 to 50 μm. The measurement of specular reflectivity (SR) was performed using a D&S Reflectometer at wavelength 660 nm. A non-contact reflectometer was designed and constructed for rapid measurement of specular reflectivity at the same wavelength. The use of this new noncontact instrument allowed us to measure SR before and after EDS activation. Several EDS prototypes were constructed and evaluated with different electrode configurations, electrode materials, and encapsulating dielectric materials.

14 SOLAR ENERGY↗

Advanced Manufacturing Office Clean Water Processing Technologies: Workshop Series Summary Report

The U.S. Department of Energy (DOE) Advanced Manufacturing Office (AMO) held a series of three clean water processing technologies workshops focusing on technical challenges and opportunities. The first workshop focused on energy optimized desalination technology development and was held in San Francisco on Nov. 5th and 6th, 2015 at the Hilton San Francisco Union Square. The next two occurred in summer 2017 starting with a workshop held in Dallas, Texas at the Hilton Dallas Lincoln Centre on July 10th and 11th, 2017 followed by the third workshop in Cleveland, Ohio at the Wyndham Cleveland at Playhouse Square on August 23rd and 24th, 2017. Below is a high level summary of scope and outcomes from each workshop.

42 ENGINEERING↗

Corrective Action Decision Document/Corrective Action Plan for Corrective Action Unit 414: Clean Slate III Plutonium Dispersion (TTR) Tonopah Test Range, Nevada, Revision 1

This Corrective Action Decision Document/Corrective Action Plan provides the rationale and supporting information for the selection and implementation of corrective actions at Corrective Action Unit (CAU) 414, Clean Slate III Plutonium Dispersion (TTR). This document has been developed in accordance with the Federal Facility Agreement and Consent Order. CAU 414 is located on the Tonopah Test Range and includes one corrective action site, TA-23-03CS, Pu Contaminated Soil.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Clean Cities Coalitions 2019 Activity Report

The U.S. Department of Energy’s (DOE) Office of Energy Efficiency and Renewable Energy’s Vehicle Technologies Office (VTO) works with local Clean Cities coalitions across the country as part of its Technology Integration Program. These efforts help businesses and consumers make smarter/more-informed transportation energy choices that can save energy, lower costs, reduce reliance on imported oil, and reduce air emissions. This report summarizes the success and impact of coalition activities based on data and information provided in their annual progress reports.

33 ADVANCED PROPULSION SYSTEMS↗

The Yucatan Peninsula Energy Assessment: Pathways for a Clean and Sustainable Power System

This report begins with an overview of the status of the power sector in Mexico's Yucatán peninsula, including key challenges, followed by policy and program solutions that pave the way for a cleaner, more sustainable power sector in the Yucatan. This work is intended to provide information to the states of the Yucatán peninsula - Yucatán, Campeche, and Quintana Roo - for prioritization and future technical assistance from the 21st Century Power Partnership (21CPP) program, in Mexico including data gathering, capacity building, modelling and analysis, program and policy setting to help the states and the region overall best utilize its resources to meet its electricity needs while implementing energy efficiency measures towards a more sustainable, clean, reliable system with lower prices. This report is also available in Spanish: https://www.nrel.gov/docs/fy21osti/81142.pdf.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Clean Grid Vision: A U.S. Perspective - Executive Summary

Clean Grid Vision: A U.S. Perspective aims to present a range of possible pathways for future grid development and call attention to some common trends. It focuses on the lessons learned through NREL’s studies of the U.S. power sector that have measured the impacts of high-penetration VRE and have tested strategies for enhancing grid flexibility and reliability. As such, this report is limited in its scope and does not attempt to review or summarize all grid integration literature. While it refers to relevant external literature to provide context when needed, this report is primarily a summary of the National Renewable Energy Laboratory’s (NREL’s) research in the past 5 years on five key topics: grid planning and operation, grid reliability at the distribution level, grid reliability at the transmission level, demand-side resources, and power markets—each corresponds to a chapter in this report. The main insights of the report are presented in this executive summary.

24 POWER TRANSMISSION AND DISTRIBUTION↗