Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Microstructure Changes Observed in the Near-Surface Region of SRF Nb Cavities Cutouts upon Cooling/Heating Cycles Using GI-Synchrotron XRD

We have mapped microstructural changes in the near-surface region of Nb from SRF cavity-cutouts upon thermal cycles in the range from 300 to 30 K using grazing incidence synchrotron X-Ray diffraction (GIXRD). Segregation of secondary phases was observed after the thermal cycle, and their nature has been clarified and discussed in view of previous studies on hydrides formation in SRF bulk Nb cavities. The temperature dependence of the relative population of these formed phases was obtained from GIXRD patterns profile fitting. Both, Nb bulk matrix and the new phases formed after cool-down show specific structural features as thermal contraction/expansion, structural transitions, and Nb lattice variation due to the induced strain by precipitates formation. The information derived from this structural study can explain some phenomena as the dissipation at high accelerating field (i.e. High Field Q Slope, HFQS) in the Nb SRF performance as well as new mechanisms never addressed in previous studies.

43 PARTICLE ACCELERATORS↗

Review of the Application Piezoelectric Actuators for SRF Cavity Tuners

Large SRF Linacs and HEP experiments require accurate frequency control, which is achieved using cavity tuners typically actuated by the piezoelectric ceramic stacks. The piezoelectric ceramic stacks became ’standard’ components of the SRF cavity tuner and, depending on the application, could be operated in the different environment: in air, at cryogenic temperature, in vacuum, and submerged in liquid helium. Different applications place different requirements on the piezo actuators, but the important parameters, common to all applications, are the lifetime and reliability of the actuators. Several R&D programs targeting the development of reliable piezo actuators are reviewed in this contribution.

43 PARTICLE ACCELERATORS↗

SIMS CHARACTERIZATION OF NITROGEN DOPING OF LCLS-II-HE PRODUCTION CAVITIES

The thermal diffusion of nitrogen into the surface of niobium has been shown to yield superior low-loss SRF performance. An effective solution was identified and promptly employed in the production of cryomodules for LCLS-II. With added experience and R&D, a modified process was chosen for use in the upgrade for LCLS-II-HE. Largely motivated by this circumstance, supporting research has significantly refined the technique for making calibrated secondary ion mass spectrometry (SIMS) measurements of the N concentration depth profiles produced by production processes. Standardized reference samples were included with four HE production cavities in their N-doping furnace runs. We report the calibrated dynamic SIMS depth profiles of N, C, and O for these samples, together with the cryogenic acceptance test performance of the associated cavities. Interpretation and comparison with similar samples acquired in other furnaces highlights the importance of intentional process quality control of furnace conditions.

Reece, Charles↗

CHARACTERIZATION OF DISSIPATIVE REGIONS OF A N-DOPED SRF CAVITY

We report scanning tunneling microscopy measurements on N-doped cavity hot and cold spot cutouts. Analysis of the electron tunneling spectra using a proximity effect theory shows that hot spots have a reduced superconducting gap and a wider distribution of the contact resistance. Alone, these degraded superconducting properties account for a much weaker excess dissipation as compared with the vortex contribution. Based on the correlation between the quasiparticle density of states and temperature mapping, we suggest that degraded superconducting properties may facilitate vortex nucleation or settling of trapped flux during cooling the cavity through the critical temperature.

Lechner, E.M.↗

Higher order mode analysis of a 915 MHz 2-cell cavity for a prototype industrial accelerator

A possible solution to reduce the complexity posed by the cryogenic systems in a superconducting RF accelerator for industrial applications, is to capitalize on the advances achieved by the Nb3Sn superconducting RF technology, as well as the feasibility of a reliable 4 K cooling system, based on commercial cryocoolers. Following this philosophy, the conceptual design for a prototype, conduction-cooled, 4 MeV, 20 kW SRF electron linac, is being developed at Jefferson Lab. Such design is based on a 915 MHz two-cell Nb3Sn cavity. In this contribution, we present the proposed cavity design, including the fundamental power coupler, and the analysis of the Higher Order Modes, using numerical simulations to estimate the potentially dangerous modes and to provide the requirements for damping for reliable operations with a cryocooler.

Rimmer, Robert↗

Temperature, rf field, and frequency dependence performance evaluation of superconducting niobium half-wave coaxial cavity

Recent advancement in superconducting radio frequency cavity processing techniques, with diffusion of impurities within the RF penetration depth, resulted in high quality factor with increase in quality factor with increasing accelerating gradient. The increase in quality factor is the result of a decrease in the surface resistance as a result of nonmagnetic impurities doping and change in electronic density of states. The fundamental understanding of the dependence of surface resistance on frequency and surface preparation is still an active area of research. Here, we present the result of RF measurements of the TEM modes in a coaxial half-wave niobium cavity resonating at frequencies between 0.3 ? 1.3 GHz. The temperature dependence of the surface resistance was measured between 4.2 K and 1.6 K. The field dependence of the surface resistance was measured at 2.0 K. The baseline measurements were made after standard surface preparation by buffered chemical polishing.

Dhakal, P.↗

IN SITU PLASMA PROCESSING OF SUPERCONDUCTING CAVITIES AT JLAB, 2023 UPDATE

Jefferson Lab has an ongoing R&D program in plasma processing which just completed a round of production processing in the CEBAF accelerator. Plasma processing is a common technique for removing hydrocarbons from surfaces, which increases the work function and reduces the secondary emission coefficient. The initial focus of the effort was processing C100 cavities by injecting RF power into the higher order mode (HOM) coupler ports. Results from processing cryomodules in the CEBAF accelerator as well as vertical test results will be present-ed. The goal of in-situ processing is to improve the operational gradients and the energy margin of the linacs. This work will describe the systems and methods used at JLAB for processing cavities using an argon-oxygen gas mixture as well as a helium-oxygen gas mixture. Before and after plasma processing results will also be presented.

Powers, Thomas↗

Nb 3 Sn Superconducting RF Cavities: R&D Progress at Fermilab and Opportunities

Nb 3 Sn becomes superconducting at twice as high temperature as our standard SRF material niobium. This allows us to efficiently operate Nb 3 Sn cavities at 4.4 K instead of the usual 2 K. This reduces cryogenic costs and even makes it possible to use a cryocooler instead of a large, complex cryogenic plant. The superheating field H sh of Nb 3 Sn is twice that of niobium. H sh is thought to be the ultimate limit for a defect-free superconductor. Nb 3 Sn cavities being made today are still about a factor of 4 away from this ultimate limit, but R&D has been leading to substantial progress towards this goal.

43 PARTICLE ACCELERATORS↗

Nb 3 Sn Superconducting RF Cavities: R&D Progress at Fermilab and Opportunities [Poster]

Nb 3 Sn becomes superconducting at twice as high temperature as our standard SRF material niobium. This allows us to efficiently operate Nb 3 Sn cavities at 4.4 K instead of the usual 2 K. This reduces cryogenic costs and even makes it possible to use a cryocooler instead of a large, complex cryogenic plant. The superheating field Hsh of Nb 3 Sn is twice that of niobium. Hsh is thought to be the ultimate limit for a defect-free superconductor. Nb 3 Sn cavities being made today are still about a factor of 4 away from this ultimate limit, but R&D has been leading to substantial progress towards this goal

43 PARTICLE ACCELERATORS↗

Review of Cavity Radius and Chimney Height Information for Underground Nuclear Tests at Nevada National Security Site

Underground nuclear explosions release an immense amount of thermal and mechanical energy that alter the geologic materials surrounding the “working point” (WP = underground location) of the detonation. Explosion effects produce mechanically and thermally altered zones such as the “cavity,” “chimney,” and “melt glass puddle,”as well as concentric zones of crushed, compressed, and fractured rock extending away from the cavity wall.

58 GEOSCIENCES↗

A White Paper on Design and Fabrication of SRF Deflecting Cavities for Elletra-2

Synchrotron Trieste (ST) operates an X-ray light source Elettra and plans to upgrade it to a low-emittance high-brightness X-ray source Elettra-2.0 based on a multi-bend achromat lattice. There is also a significant interest among Elettra users to pursue time-resolved studies of matter choosing the appropriate X-ray pulse duration in the range from 20 picoseconds to a few picoseconds FWHM. Recently, X. Huang (SLAC) and A. Zholents (ANL) performed a study sponsored by ST and proposed modifications to the Elettra-2.0 design that will allow production of picosecond x-ray pulses on many beamlines. They showed that two radio frequency deflecting cavities with slightly different frequencies can be installed in the ring’s sector 8 and produce time-dependent orbit deflection to a few dedicated electron bunches without affecting other regular bunches. These special bunches produce X-ray pulses in which transverse position or angle, or both, are correlated with time. The short X-ray pulse is then obtained by using a narrow slit positioned downstream in the beamline. Many technical details of the proposed modification to Elettra-2.0 are discussed in the supplemental report. We present here the design of a multicell superconducting deflecting cavity for the purpose of the ST Short Pulse X-ray (SPX) project.

43 PARTICLE ACCELERATORS↗

Novel High-Current SRF Cavity With On-Cell Waveguide Dampers

A new concept was proposed to improve the Higher-Order-Mode (HOM) damping in Superconducting Radio Frequency (SRF) cavities beyond state-of-the-art. A prototype cavity was planned to be built and tested in JLab’s Vertical Test Area as a proof-of-principle.

42 ENGINEERING↗

Three Dimensional Electromagnetic High Frequency Convex Cavity Scars

This report examines the localization of high frequency electromagnetic fields in general three-dimensional convex walled cavities along periodic paths between opposing sides of the cavity. The report examines the three-dimensional case where the mirrors at the end of the orbit have two different radii of curvature. The cases where these orbits lead to unstable localized modes are known as scars.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of Microwave Resonant Cavity Transducer Degradation Mechanisms

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Three-Dimensional Electromagnetic High Frequency Concave Cavity Scars

This report examines the localization of high frequency electromagnetic fields in general three-dimensional cavities along periodic paths between opposing sides of the cavity. The focus is on the case where the mirrors at the ends of the orbit are concave and have two different radii of curvature. The cases where these orbits lead to unstable localized modes are known as scars. The ellipsoidal coordinate system is utilized in the construction of the scarred modes. The field at the interior foci is examined as well as trigonometric projections along the periodic scarred ray path.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of the Electron Ion Collider Electron Storage Ring SRF cavity

The Electron Ion Collider (EIC) under construction at Brookhaven National Laboratory is a high luminosity collider as the next major research facility for the nuclear physics community. Among the numerous RF subsystems in the EIC, the electron storage ring (ESR) fundamental RF cavities system is one of the most challenging. This system will handle a high beam current of up to 2.5A and replenish up to 10MW of beam power losses from synchrotron radiation and HOM. Variable coupling is required in the cavities due to the wide range of required total RF voltage and beam current combinations. In this paper, we will present the status of the design and future plans.

Guo, J.↗

INITIAL STUDIES OF CAVITY FAULT PREDICTION AT JEFFERSON LABORATORY

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is a CW recirculating linac that utilizes over 400 superconducting radio-frequency (SRF) cavities to accelerate electrons up to 12 GeV through 5-passes. Recent work has shown that, given RF signals from a cavity during a fault as input, machine learning approaches can accurately classify the fault type. In this paper we report on initial results of predicting a fault onset using only data prior to the failure event. A data set was constructed using time-series data immediately before a fault (’unstable’) and 1.5 seconds prior to a fault (’stable’) gathered from over 5,000 saved fault events. The data was used to train a binary classifier. The results gave key insights into the behavior of several fault types and provided motivation to investigate whether data prior to a failure event could also predict the type of fault. We discuss our method using a sliding window approach and report on initial results. Recent modifications to the low-level RF control system will provide access to streaming signals and we outline a path forward for leveraging deep learning on streaming data

Vidyaratne, Lasitha↗

SRF Cavity Fault Classification and Prediction at Jefferson Lab

Over the last few years several machine learning projects at Jefferson Lab have had a common focus to optimize operation of superconducting RF (SRF) cavities in the Continuous Electron Beam Accelerator Facility (CEBAF). In this talk we highlight work to identify and classify types of faults from C100-type cavities and then to extend those capabilities to provide real-time fault prediction. Early prediction may enable mitigation strategies to prevent some types of faults. In our approach we apply a two-step fault prediction pipeline. In the first step, a model distinguishes between faulty and normal signals. In the second step, signals flagged as faulty by the first model are classified into one of seven fault types based on learned signatures in the data. Initial results show that our model can successfully predict most fault types 200 ms before onset. In additional to model performance, we also highlight challenges in working with real-world data and challenges for deploying models.

Tennant, C.↗