Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “casing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

A software framework for assessing the resilience of drinking water systems to disasters with an example earthquake case study

Water utilities are vulnerable to a wide variety of human-caused and natural disasters. The Water Network Tool for Resilience (WNTR) is a new open source PythonTM package designed to help water utilities investigate resilience of water distribution systems to hazards and evaluate resilience-enhancing actions. In this paper, the WNTR modeling framework is presented and a case study is described that uses WNTR to simulate the effects of an earthquake on a water distribution system. The case study illustrates that the severity of damage is not only a function of system integrity and earthquake magnitude, but also of the available resources and repair strategies used to return the system to normal operating conditions. While earthquakes are particularly concerning since buried water distribution pipelines are highly susceptible to damage, the software framework can be applied to other types of hazards, including power outages and contamination incidents.

97 MATHEMATICS AND COMPUTING↗

Shear strength and permeability of the cement-casing interface

Here, the shear strength and hydraulic permeability of the interface between well cement and casing was investigated using a triaxial direct shear apparatus. For the first time, these experiments provide measurements under controlled stress conditions with fluid flow measurements along the interface. The low cohesion (1.1 ± 1.1 MPa) and the high friction angle (43.4 ± 2.0°) indicates that the shear strength of the interface is provided by friction. This implies that the state of stress of the cement is critical to well integrity. The hydraulic aperture of the undamaged cement-steel samples was 6.8 ± 1.0 microns. Shear damage to the interface caused a decrease (-20 %) in hydraulic aperture for samples aged up to 1 month, and an increase (+300 %) for samples cured for two years. We performed numerical simulations to estimate the leakage potential from a carbon storage operation. This model predicts negligible leakage amounts (47 tonnes) in a shear-damaged well for the modeled injection of ~1.26 million tonnes of CO 2 . Thus, our measurements indicate that the cement-casing interface is not a significant leakage pathway in its intact or damaged state, and that shear-driven failure scenarios for this interface are not a significant risk to CO 2 storage security.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of flammable volume in the case of a catastrophic leak of R-32 from a rooftop unit

With the effort to use alternative refrigerants with lower global warming potential (GWP), the majority of these alternative refrigerants are classified as slightly flammable. Here in this paper we report on the numerical evaluation of a catastrophic leak scenario of R-32 refrigerant from a 3-ton roof top air conditioning unit (RTU) which serves a 12.2 × 9.14 × 2.4 m room. A full rupture of a 6.35 mm (¼ inch) pipe downstream of the evaporator coil is simulated. Two separate cases with refrigerant releases of 1.81 kg and 3.62 kg charge have been studied. The two charges are released in 10.2 and 20.4 s, respectively, just after the end of a unit cooling cycle. The flammable volume inside the room existed only for about 40 s with a maximum flammable volume inside the room of 1.12% of the total room volume for the 3.62 kg charge case.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Case Study in Proton Pencil-Beam Scanning Delivery

Purpose: We completed an implementation of pencil-beam scanning (PBS), a technology whereby a focused beam of protons, of variable intensity and energy, is scanned over a plane perpendicular to the beam axis and in depth. The aim of radiotherapy is to improve the target to healthy tissue dose differential. We illustrate how PBS achieves this aim in a patient with a bulky tumor. Methods and Materials: Our first deployment of PBS uses 'broad' pencil-beams ranging from 20 to 35 mm (full-width-half-maximum) over the range interval from 32 to 7 g/cm{sup 2}. Such beam-brushes offer a unique opportunity for treating bulky tumors. We present a case study of a large (4,295 cc clinical target volume) retroperitoneal sarcoma treated to 50.4 Gy relative biological effectiveness (RBE) (presurgery) using a course of photons and protons to the clinical target volume and a course of protons to the gross target volume. Results: We describe our system and present the dosimetry for all courses and provide an interdosimetric comparison. Discussion: The use of PBS for bulky targets reduces the complexity of treatment planning and delivery compared with collimated proton fields. In addition, PBS obviates, especially for cases as presented here, the significant cost incurred in the construction of field-specific hardware. PBS offers improved dose distributions, reduced treatment time, and reduced cost of treatment.

07 ISOTOPE AND RADIATION SOURCES↗

Stereotactic Irradiation of the Postoperative Resection Cavity for Brain Metastasis: A Frameless Linear Accelerator-Based Case Series and Review of the Technique

Purpose: Whole-brain radiation therapy (WBRT) is the standard of care after resection of a brain metastasis. However, concern regarding possible neurocognitive effects and the lack of survival benefit with this approach has led to the use of stereotactic radiosurgery (SRS) to the resection cavity in place of WBRT. We report our initial experience using an image-guided linear accelerator-based frameless stereotactic system and review the technical issues in applying this technique. Methods and Materials: We retrospectively reviewed the setup accuracy, treatment outcome, and patterns of failure of the first 18 consecutive cases treated at Brigham and Women's Hospital. The target volume was the resection cavity without a margin excluding the surgical track. Results: The median number of brain metastases per patient was 1 (range, 1-3). The median planning target volume was 3.49 mL. The median prescribed dose was 18 Gy (range, 15-18 Gy) with normalization ranging from 68% to 85%. In all cases, 99% of the planning target volume was covered by the prescribed dose. The median conformity index was 1.6 (range, 1.41-1.92). The SRS was delivered with submillimeter accuracy. At a median follow-up of 12.7 months, local control was achieved in 16/18 cavities treated. True local recurrence occurred in 2 patients. No marginal failures occurred. Distant recurrence occurred in 6/17 patients. Median time to any failure was 7.4 months. No Grade 3 or higher toxicity was recorded. A long interval between initial cancer diagnosis and the development of brain metastasis was the only factor that trended toward a significant association with the absence of recurrence (local or distant) (log-rank p = 0.097). Conclusions: Frameless stereotactic irradiation of the resection cavity after surgery for a brain metastasis is a safe and accurate technique that offers durable local control and defers the use of WBRT in select patients. This technique should be tested in larger prospective studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Second Malignant Neoplasms in Digestive Organs After Childhood Cancer: A Cohort-Nested Case-Control Study

Purpose: Cancers of the digestive system constitute a major risk for childhood cancer survivors treated with radiotherapy once they reach adulthood. The aim of this study was to determine therapy-related risk factors for the development of a second malignancy in the digestive organs (SMDO) after a childhood cancer. Methods and Materials: Among 4,568 2-year survivors of a childhood solid cancer diagnosed before 17 years of age at eight French and British centers, and among 25,120 patients diagnosed as having a malignant neoplasm before the age of 20 years, whose data were extracted from the Nordic Cancer Registries, we matched 58 case patients (41 men and 17 women) of SMDO and 167 controls, in their respective cohort, for sex, age at first cancer, calendar year of occurrence of the first cancer, and duration of follow-up. The radiation dose received at the site of each second malignancy and at the corresponding site of its matched control was estimated. Results: The risk of developing a SMDO was 9.7-fold higher in relation to the general populations in France and the United Kingdom. In the case-control study, a strong dose-response relationship was estimated, compared with that in survivors who had not received radiotherapy; the odds ratio was 5.2 (95% CI, 1.7-16.0) for local radiation doses between 10 and 29 Gy and 9.6 (95% CI, 2.6-35.2) for doses equal to or greater than 30 Gy. Chemotherapy was also found to increase the risk of developing SMDO. Conclusions: This study confirms that childhood cancer treatments strongly increase the risk of SMDO, which occur only after a very long latency period.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Short-Term and Intermediate-Term Risk of Second Neoplasms After Diagnosis and Treatment of Unilateral Vestibular Schwannoma: Analysis of 9460 Cases

Purpose: To determine the incidence of second intracranial neoplasms after the diagnosis and treatment of sporadic vestibular schwannoma (VS). Methods and Materials: Analysis of the Surveillance, Epidemiology, and End Results (SEER) database including all patients identified with a diagnosis of VS and a second intracranial tumor. The Kaplan-Meier method was used to determine the incidence of second tumors while allowing for censoring at loss to follow-up or death. Multivariable associations between treatment modality and second tumor formation were explored using Cox proportional hazards regression analysis. Two illustrative cases are also presented. Results: In all, 9460 patients with unilateral VS were identified between 2004 and 2012. Overall, 66 (0.7%) patients experienced a separate intracranial tumor, benign or malignant, after treatment of VS. Kaplan-Meier estimates for time to second neoplasm at 1, 3, and 5 years were 0.3%, 0.7%, and 0.8%, respectively. Multivariable comparison between VS treatment modalities revealed that the risk of second tumor formation was similar between radiation and surgery (hazard ratio [HR] 0.74; 95% confidence interval [CI] 0.36-1.51; P=.93) but greater for tumors managed with observation alone compared with radiation (HR 2.48; 95% CI 1.31-4.71; P<.01). A total of 6 (0.06%) intracranial malignancies were diagnosed after VS treatment. Kaplan-Meier estimates for time to malignancy at 1, 3, and 5 years were 0%, 0.1%, and 0.1%, respectively. After adjustment for age at diagnosis, sex, and treatment modality, the probability of malignancy after radiation was not greater than after observation alone or microsurgery (HR 4.88; 95% CI 0.85-28.14; P=.08) during the study period. Conclusions: The risk for the development of a second intracranial neoplasm, benign or malignant, at 5 years after treatment of unilateral VS is approximately 0.8%, whereas the risk of acquiring a separate malignancy is 0.1%, or approximately 1 per 1000 cases. The short-term and intermediate-term incidence of second neoplasm after radiation of VS is not greater than the incidence after microsurgery or observation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The international implications of national and local coordination on building energy codes: Case studies in six cities

Building energy efficiency is an important strategy for reducing greenhouse gas emissions globally. In fact, 55 countries have included building energy efficiency in their Nationally Determined Contributions (NDCs) under the Paris Agreement. This research uses building energy code implementation in six cities across different continents as case studies to assess what it may take for countries to implement the ambitions of their energy efficiency goals. Specifically, we look at the cases of Bogota, Colombia; Da Nang, Vietnam; Eskisehir, Turkey; Mexico City, Mexico; Rajkot, India; and Tshwane, South Africa, all of which are “deep dive” cities under the Sustainable Energy for All's Building Efficiency Accelerator. The research focuses on understanding the baseline with existing gaps in implementation and coordination. The methodology used a combination of surveys on code status and interviews with stakeholders at the local and national level, as well as review of published documents. We looked at code development, implementation, and evaluation. The cities are all working to improve implementation, however, the challenges they currently face include gaps in resources, capacity, tools, and institutions to check for compliance. Better coordination between national and local governments could help improve implementation, but that coordination is not yet well established. For example, all six of the cities reported that there was little to no involvement of local stakeholders in development of the national code; only one city reported that it had access to national funding to support code implementation. More robust coordination could better link cities with capacity building and funding for compliance, and ensure that the code reflects local priorities. By understanding gaps in implementation, it can also help in designing more targeted interventions to scale up energy savings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An efficient hybrid MLFMA-FFT solver for the volume integral equation in case of sparse 3D inhomogeneous dielectric scatterers

Electromagnetic scattering problems involving inhomogeneous objects can be numerically solved by applying a Method of Moments discretization to the volume integral equation. For electrically large problems, the iterative solution of the resulting linear system is expensive, both computationally and in memory use. In this paper, a hybrid MLFMA-FFT method is presented, which combines the fast Fourier transform (FFT) method and the High Frequency Multilevel Fast Multipole Algorithm (MLFMA) in order to reduce the cost of the matrix-vector multiplications needed in the iterative solver. The method represents the scatterers within a set of possibly disjoint identical cubic subdomains, which are meshed using a uniform cubic grid. This specific mesh allows for the application of FFTs to calculate the near interactions in the MLFMA and reduces the memory cost considerably, since the aggregation and disaggregation matrices of the MLFMA can be reused. Additional improvements to the general MLFMA framework, such as an extention of the FFT interpolation scheme of Sarvas et al. from the scalar to the vectorial case in combination with a more economical representation of the radiation patterns on the lowest level in vector spherical harmonics, are proposed and the choice of the subdomain size is discussed. The hybrid method performs better in terms of speed and memory use on large sparse configurations than both the FFT method and the HF MLFMA separately and it has lower memory requirements on general large problems. This is illustrated on a number of representative numerical test cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a U-19Pu-10Zr fuel performance benchmark case based on the IFR-1 experiment

Metallic nuclear fuels are subject to research and development for use in advanced reactors. Robust, accurate metallic fuel performance models are important for the design, safety analysis, and licensing of these reactors. However, metallic fuel performance models require additional development; they are not as mature as UO 2 fuel performance models. A benchmark case based on the IFR-1 experiment was developed to better gauge the accuracy of existing models, identify models for high-priority development, and potentially quantify any future improvements made by further model development.This work collected publicly available information on the IFR-1 experiment and used it to develop the benchmark case. Fuel behavior during the IFR-1 irradiation was simulated by using the fuel performance code BISON, and the predicted results were compared with postirradiation examination data from the IFR-1 experiment. Furthermore, a sensitivity study and tuning studies were performed as a preliminary investigation into the causes of inaccurate temperature and dimensional change predictions.The benchmark predicted reasonably accurate values for the burnup and fission gas release. There was error in the predicted temperatures, which could be explained by uncertainty in the input parameters and legacy temperatures. BISON over-predicted dimensional changes in the fuel and cladding. The sensitivity study showed that the dimensional changes were most sensitive to the fuel swelling anisotropy and the cladding void swelling model. Future benchmark and model development should focus on cladding swelling behaviors to improve dimensional change predictions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

25-Pin metallic fuel performance benchmark case based on the EBR-II X430 experiments series

A metallic fuel benchmark case was developed for the fuel performance code BISON based on 25 uranium-zirconium and uranium-plutonium-zirconium pins of the Experimental Breeder Reactor II X430 experiment series. Results of the benchmarks were compared with measurements and calculations made at the time of the experiment as well as subsequent measurements reported in 2019. The comparisons were used to quantify the accuracy of the BISON predictions and to identify patterns in the BISON differences.BISON predicted burnup, plenum pressure, and fission gas release fractions accurately. BISON temperature predictions were somewhat cooler than the temperatures determined at the time of the experiment but appeared to be reasonably accurate considering uncertainties in the legacy temperature calculations, uncertainties in the legacy linear heat rate calculations, and the high sensitivities of the BISON-predicted temperatures to BISON inputs. Fuel axial elongation predictions had errors correlated to fuel composition; BISON tended to underpredict the elongation of binary fuels and overpredict the elongation of ternary fuels. BISON cladding radial dilation predictions were also significantly lower than legacy PIE measurements.Recommendations were made to improve the BISON fuel gaseous swelling model to account for fuel composition, to add additional capabilities to the coolant channel temperature model to ease benchmark development, and to continue developing benchmark cases based on a wide range of experiments in several reactors. Once a wide array of benchmarks is developed, an attempt can be made to enhance or calibrate BISON models to improve the cladding dilation predictions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Effect of Significant Tumor Reduction on the Dose Distribution in Intensity Modulated Radiation Therapy for Head-And-Neck Cancer: A Case Study

We present a unique case in which a patient with significant tissue loss was monitored for dosimetric changes using weekly cone beam computed tomography (CBCT) scans. A previously treated nasopharynx patient presented with a large, exophytic, recurrent left neck mass. The patient underwent re-irradiation to 70 Gy using intensity modulated radiation therapy (IMRT) with shielding blocks over the spinal cord and brain stem. Weekly CBCT scans were acquired during treatment. Target contours and treatment fields were then transferred from the original treatment planning computed tomography (CT) to the CBCT scans and dose calculations were performed on all CBCT scans and compared to the planning doses. In addition, a 'research' treatment plan was created that assumed the patient had not been previously treated, and the above analysis was repeated. Finally, to remove the effects of setup error, the outer contours of 2 CBCT scans with significant tumor reductions were transferred to the planning scan and dose in the planning scan was recalculated. Planning treatment volume (PTV) decreased 45% during treatment. Spinal cord D05 differed from the planned value by 3.5 {+-} 9.8% (average + standard deviation). Mean dose to the oral cavity and D05 of the mandible differed from the planned value by 0.9 {+-} 2.1% and 0.6 {+-} 1.5%, respectively. Results for the research plan were comparable. Target coverage did not change appreciably (-0.2 {+-} 2.5%). When the planning scan was recalculated with the reduced outer contour from the CBCT, spinal cord D05 decreased slightly due to the reduction in scattered dose. Weekly imaging provided us the unique opportunity to use different methods to examine the dosimetric effects of an unusually large loss of tissue. We did not see that tissue loss alone resulted in a significant effect on the dose delivered to the spinal cord for this case, as most fluctuation was due to setup error. In the IGRT era, delivered dose distributions can be more readily determined during treatment, and this information can be useful in deciding whether replanning is necessary.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Case Report on the Effect of Fan Beam Thickness in Helical Tomotherapy of Nasopharyngeal Carcinoma

The fan beam thickness (FBT) in helical tomotherapy is defined by a pair of collimators parallel to the rotational orbit of the radiation beam and is fixed for a specific patient treatment. The aim of this case study is to evaluate the dosimetric influence of changing the FBT in the treatment of a nasopharyngeal carcinoma (NPC) patient. The subject was a T2N1M0 stage NPC patient. The planning target volumes (PTVs) of the primary nasopharyngeal tumor and the left and right cervical lymphatics were delineated along with the organs at risk (OARs) in the corresponding computed tomography slices. Three treatment plans with FBT of 1.0 cm, 2.5 cm, and 5.0 cm (FBT-10, FBT-25, and FBT-50) were generated separately based on similar dose constraints and planning parameters. The dosimetric results of the PTV and OARs were collected and compared among the 3 treatment plans. The differences in the dose parameters of the PTVs were small among the 3 plans. The FBT-10 plan demonstrated the most homogeneous PTV doses with the smallest homogeneity indices (HIs). The FBT-50 plan delivered the highest dose to the OARs and the FBT-10 plan delivered the lowest. The differences between the 2 plans were more significant in the spinal cord, optic chiasm, optic nerves, and lens. This case study demonstrated that the variation of FBT in tomotherapy affected the quality of the treatment plan mainly in the OAR doses, but not so much in the PTV. Increasing the FBT reduced the effectiveness in the sparing of OARs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Total dural irradiation: RapidArc versus static-field IMRT: A case study

The purpose of this study was to compare conventional fixed-gantry angle intensity-modulated radiation therapy (IMRT) with RapidArc for total dural irradiation. We also hypothesize that target volume-individualized collimator angles may produce substantial normal tissue sparing when planning with RapidArc. Five-, 7-, and 9-field fixed-gantry angle sliding-window IMRT plans were generated for comparison with RapidArc plans. Optimization and normal tissue constraints were constant for all plans. All plans were normalized so that 95% of the planning target volume (PTV) received at least 100% of the dose. RapidArc was delivered using 350 Degree-Sign clockwise and counterclockwise arcs. Conventional collimator angles of 45 Degree-Sign and 315 Degree-Sign were compared with 90 Degree-Sign on both arcs. Dose prescription was 59.4 Gy in 33 fractions. PTV metrics used for comparison were coverage, V{sub 107}%, D1%, conformality index (CI{sub 95}%), and heterogeneity index (D{sub 5}%-D{sub 95}%). Brain dose, the main challenge of this case, was compared using D{sub 1}%, Dmean, and V{sub 5} Gy. Dose to optic chiasm, optic nerves, globes, and lenses was also compared. The use of unconventional collimator angles (90 Degree-Sign on both arcs) substantially reduced dose to normal brain. All plans achieved acceptable target coverage. Homogeneity was similar for RapidArc and 9-field IMRT plans. However, heterogeneity increased with decreasing number of IMRT fields, resulting in unacceptable hotspots within the brain. Conformality was marginally better with RapidArc relative to IMRT. Low dose to brain, as indicated by V5Gy, was comparable in all plans. Doses to organs at risk (OARs) showed no clinically meaningful differences. The number of monitor units was lower and delivery time was reduced with RapidArc. The case-individualized RapidArc plan compared favorably with the 9-field conventional IMRT plan. In view of lower monitor unit requirements and shorter delivery time, RapidArc was selected as the optimal solution. Individualized collimator angle solutions should be considered by RapidArc dosimetrists for OARs dose reduction. RapidArc should be considered as a treatment modality for tumors that extensively involve in the skull, dura, or scalp.

61 RADIATION PROTECTION AND DOSIMETRY↗

A case report on bilateral partial breast irradiation using SAVI

To assess dosimetric parameters in a case study where bilateral accelerated partial breast irradiation (APBI) is delivered using a strut-adjusted volume implant (SAVI) device. A 59-year-old female received APBI in both breasts over 5 days, with fractions of 3.4 Gy twice daily. A Vac-lok system was used for immobilization, and a C-arm was used for daily imaging. We generated dose-volume histograms (DVHs) for the brachytherapy plans to derive several important biologic factors. We calculated the normal tissue complication probability (NTCP), equivalent uniform dose (EUD), and tumor control probability (TCP) using the Lyman-Kutcher-Burman model parameters {alpha} = 0.3 Gy{sup -1}, {alpha}/{beta} = 4 Gy, n = 0.1, and m = 0.3. In addition, we assessed the dose homogeneity index (DHI), overdose index, and dose nonuniformity ratio. D95 was >95% and V150 was <50 mL for both breasts. The DHIs were 0.469 and 0.512 for the left and right breasts, respectively. The EUDs (normalized to 3.4 Gy b.i.d.) were 33.53 and 29.10 Gy. The TCPs were estimated at 99.2% and 99.9%, whereas the NTCP values were 4.2% and 2.57%. In this clinical case, we were able to quantify the dosimetric parameters of an APBI treatment performed with a SAVI device.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of different breathing patterns in the same patient on stereotactic ablative body radiotherapy dosimetry for primary renal cell carcinoma: A case study

Stereotactic ablative body radiotherapy (SABR) for primary renal cell carcinoma (RCC) targets requires motion management strategies to verify dose delivery. This case study highlights the effect of a change in patient breathing amplitude on the dosimetry to organs at risk and target structures. A 73-year-old male patient was planned for receiving 26 Gy of radiation in 1 fraction of SABR for a left primary RCC. The patient was simulated with four-dimensional computed tomography (4DCT) and the tumor internal target volume (ITV) was delineated using the 4DCT maximum intensity projection. However, the initially planned treatment was abandoned at the radiation oncologist's discretion after pretreatment cone-beam CT (CBCT) motion verification identified a greater than 50% reduction in superior to inferior diaphragm motion as compared with the planning 4DCT. This patient was resimulated with respiratory coaching instructions. To assess the effect of the change in breathing on the dosimetry to the target, each plan was recalculated on the data set representing the change in breathing condition. A change from smaller to larger breathing showed a 46% loss in planning target volume (PTV) coverage, whereas a change from larger breathing to smaller breathing resulted in an 8% decrease in PTV coverage. ITV coverage was similarly reduced by 8% in both scenarios. This case study highlights the importance of tools to verify breathing motion prior to treatment delivery. 4D image guided radiation therapy verification strategies should focus on not only verifying ITV margin coverage but also the effect on the surrounding organs at risk.

61 RADIATION PROTECTION AND DOSIMETRY↗

Treatment planning for SBRT using automated field delivery: A case study

Stereotactic body radiation therapy (SBRT) treatment planning and delivery can be accomplished using a variety of techniques that achieve highly conformal dose distributions. Herein, we describe a template-based automated treatment field approach that enables rapid delivery of more than 20 coplanar fields. A case study is presented to demonstrate how modest adaptations to traditional SBRT planning can be implemented to take clinical advantage of this technology. Treatment was planned for a left-sided lung lesion adjacent to the chest wall using 25 coplanar treatment fields spaced at 11° intervals. The plan spares the contralateral lung and is in compliance with the conformality standards set forth in Radiation Therapy and Oncology Group protocol 0915, and the dose tolerances found in the report of the American Association of Physicists in Medicine Task Group 101. Using a standard template, treatment planning was accomplished in less than 20 minutes, and each 10 Gy fraction was delivered in approximately 5.4 minutes. For those centers equipped with linear accelerators capable of automated treatment field delivery, the use of more than 20 coplanar fields is a viable SBRT planning approach and yields excellent conformality and quality combined with rapid planning and treatment delivery. Although the case study discusses a laterally located lung lesion, this technique can be applied to centrally located tumors with similar results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric advantages of intensity-modulated proton therapy for oropharyngeal cancer compared with intensity-modulated radiation: A case-matched control analysis

A potential advantage of intensity-modulated proton therapy (IMPT) over intensity-modulated (photon) radiation therapy (IMRT) in the treatment of oropharyngeal carcinoma (OPC) is lower radiation dose to several critical structures involved in the development of nausea and vomiting, mucositis, and dysphagia. The purpose of this study was to quantify doses to critical structures for patients with OPC treated with IMPT and compare those with doses on IMRT plans generated for the same patients and with a matched cohort of patients actually treated with IMRT. In this study, 25 patients newly diagnosed with OPC were treated with IMPT between 2011 and 2012. Comparison IMRT plans were generated for these patients and for additional IMRT-treated controls extracted from a database of patients with OPC treated between 2000 and 2009. Cases were matched based on the following criteria, in order: unilateral vs bilateral therapy, tonsil vs base of tongue primary, T-category, N-category, concurrent chemotherapy, induction chemotherapy, smoking status, sex, and age. Results showed that the mean doses to the anterior and posterior oral cavity, hard palate, larynx, mandible, and esophagus were significantly lower with IMPT than with IMRT comparison plans generated for the same cohort, as were doses to several central nervous system structures involved in the nausea and vomiting response. Similar differences were found when comparing dose to organs at risks (OARs) between the IMPT cohort and the case-matched IMRT cohort. In conclusion, these findings suggest that patients with OPC treated with IMPT may experience fewer and less severe side effects during therapy. This may be the result of decreased beam path toxicities with IMPT due to lower doses to several dysphagia, odynophagia, and nausea and vomiting–associated OARs. Further study is needed to evaluate differences in long-term disease control and chronic toxicity between patients with OPC treated with IMPT in comparison to those treated with IMRT.

61 RADIATION PROTECTION AND DOSIMETRY↗