Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

helios: An R package to process heating and cooling degrees for GCAM

helios is an open-source R package that estimates population-weighted heating and cooling degree-hours (HDH and CDH) and degree-days (HDD and CDD) at various temporal (e.g., energy dispatch segments, monthly, yearly) and spatial scales (e.g., U.S. states, global political regions, countries). The degree hour and degree day outputs from helios are used to inform electricity demand load in the Global Change Analysis Model (GCAM) as well as in GCAM-USA (which is the version of GCAM with U.S. state-level details). helios uses a workflow with four steps: processing raw data; calculating heating and cooling degrees; visualizing performance diagnostics; and outputing results in various formats. There are two sources of widely-used climate data compatible with helios: (1) hourly climate data with 12-km resolution that are dynamically downscaled with the Weather Research and Forecasting (WRF) model and projected using a thermal global warming (TGW) approach; and (2) daily climate data with 0.5-degree resolution from the Coupled Model Intercomparison Project (CMIP) that is bias-adjusted and statistical downscaled by the Inter-Sectoral Impact Model Intercomparison Project (ISIMIP). In summary, helios is a model that standardizes methodology of heating and cooling degrees-hours and degree-days using publicly available data and advance the understanding of the impact of spatial and temporal temperature variability on building energy services.

97 MATHEMATICS AND COMPUTING↗

Intersecting heuristic adaptive strategies, building design and energy saving intentions when facing discomfort environment: A cross-country analysis

Occupants' adaptive strategies play an important role in the energy consumption of office buildings. Previous research has mostly focused on the adaptive strategies triggered by occupants' indoor discomfort; however, it is crucial to understand if specific adaptive strategies are linked to occupants' energy-saving intentions. This study explores the relationships among employees’ heuristic decision-making in their first choice of adaptive strategies (technological solutions or personal adjustments) when facing extreme discomfort conditions, and their energy-saving intentions, then links these patterns with building design, workplace contextual factors, and demographics. A cross-sectional survey was collected among university employees from China, Brazil, Italy, Poland, Switzerland, and the US. Our results demonstrated that the accessibility to indoor environmental controls (IECs) and office type are the significant factors for adaptive strategies. There was a positive relationship between the number of IEC features and the percentage of employees choosing a technological solution. When feeling too hot, occupants in private offices are more likely to adopt a technological solution, whereas occupants in cubicles are more likely to choose a personal adjustment. Occupants with energy-saving intentions are less likely to choose thermostat adjustments or use portable devices as adaptive strategies than their counterparts. Lastly, the cluster analysis suggests females were more likely to use adaptive strategies for energy-saving purposes than males. The majority of occupants would turn on/off lighting to save energy. The study provides the contributions in the connection between the heuristic decision-making process and energy-saving intentions and recommendations on design strategies for building architects, engineers, and managers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empowering Energy Efficiency in Existing Big-Box Retail/Grocery Stores (Final Optimization Report)

The Center for Sustainable Energy (CSE), in partnership with the National Renewable Energy Laboratory (NREL), TRC Energy Services, P2S Engineering Inc, Walmart, and five innovative technology providers, are to demonstrate the impact of an integrated suite of pre-commercial energy efficiency (EE) technologies in a large, existing, retail building located within an inland disadvantaged community. Proposed technology packages include three categories of advanced EE solutions: heating, ventilating, air-conditioning, and refrigerating (HVAC/R); lighting; and integrated system and building level controls. The project is designed to impact Walmart’s future store specifications, which can be replicated and deployed in other buildings across California with similar end-use and system characteristics. The following lists the technologies considered for this project: DualCool (HVAC evaporative cooling); Software Motor Company (SMC) (HVAC and refrigeration fan motor); I2S: DC LED lighting; LocBit: building energy management and optimization; Saya: water monitoring.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A dataset for understanding self-reported patterns influencing residential energy decisions

Household occupant behavior and decision-making dynamics substantially impact technology uptake and residential building energy performance. Although significant research underscores the importance of social science in energy studies, few public data with representative samples on household energy decision-making patterns are available. The dataset (UPGRADE-E: Understanding Patterns Guiding Residential Adoption and Decisions about Energy Efficiency) presents 9,919 responses from U.S. residents of single-family and small multifamily homes. Derived from a national-scale internet survey, the dataset contains 391 variables: demographics, building characteristics, home modifications, willingness to adopt new technologies, motivations for making changes, barriers, program participation, trusted information sources, and energy scenarios. Responses were validated via internal consistency checks and comparison with other U.S. national scale datasets. UPGRADE-E advances knowledge of household energy related decision-making, tying demographics, home modifications, and self-reported cognitive drivers together at a scale and breadth that has not been previously achieved. Policymakers and researchers at local, regional, and national levels may leverage this dataset to understand drivers influencing the adoption of key technologies in U.S. homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adaptive Cyber-Physical Resilience for Building Control Systems

The main goal of the project is to develop an AI-based process layer cybersecurity suite for detection, isolation and mitigation of cyber-attack effects on operation of building energy management systems (BEMS). The following constituent key technologies were developed under the program towards fulfilling the program objectives: (1) developed a high fidelity BEMS testbed for generation of training data and validation of developed technologies; (2) developed a physics informed ML based attack detection and localization module (ADL) capable of detecting high impact stealthy attacks (HISA - attacks causing 30% energy utilization but no immediate visible impact otherwise) with 98% accuracy; (3) developed a methodology to determine ’representative days’ to limit the data required for training; (4) developed a virtual sensing system that can reconstruct affected sensors with 10% error for the same HISA set; (5) developed a resilient model predictive control system that can continue operation of the BEMS without jeopardizing stability for the HISA set; and (6) integrated and deployed all the constituent modules and demonstrated the efficacy of the technology in real-time in a hardware in loop simulation.

42 ENGINEERING↗

nrelWattileExt (SkySpark Wattile Extension) [SWR-24-73]

The NREL Wattile extension, nrelWattileExt, provides an interface between SkySpark, an energy management and analytics software, and Wattile, an NREL-developed Python package for probabilistic prediction of building energy consumption. Wattile models predict discrete quantiles of the probability distribution of a target quantity (typically energy consumption) using the historical time series data from one or more predictors (typically weather data). Within SkySpark, predictions from Wattile models can be used for measurement & verification of building performance, detection of energy anomalies, and fault detection. Related to: https://github.com/NREL/Wattile

Frank, Stephen↗

Building efficiency, electrification, and distributed solar PV bill savings under time-based retail rate designs

Building energy technologies and distributed generation, including energy efficiency (EE), distributed solar PV (DPV), and building electrification, are critical to meeting decarbonization goals. Rate design may play an important role in determining the customer economics of adopting these technologies, but it is unclear whether – and to what extent – current rate design trends support or impede progress toward these goals. In this study, we answer these questions by quantifying the range of residential customer bill impacts of EE, DPV, and building electrification investments under current and emerging time-based retail electricity rate designs (i.e., time-of-use, event-based pricing, coincident demand charges, and real time pricing). We also compare these customer bill savings to power system and societal benefits and assess how well the investments are compensated relative to the societal value they provide.

14 SOLAR ENERGY↗

A new database of building-space-specific internal loads and load schedules for performance based code compliance modeling of commercial buildings

Building-level loads and load profiles prescribed by current modeling rules save modelers time and avoid gaming during whole building performance modeling. However, recent studies show that they sometimes insufficiently capture the entire building performance due to the varied loads and load profiles for different space types. As a solution to this issue, this paper develops a database of building-space-specific loads and load profiles used in code compliance modeling. The existing sets of loads and load profiles are reviewed and the challenges behind using them for specific research topics are discussed. Then, the proposed method to develop the building-space-specific loads and load profiles is introduced. After that, the database for these building-space-specific loads and load profiles is presented. In addition, one case is studied to demonstrate the applications of these loads and load profiles. In this case study, three methods are used to develop building energy models: space-specific (using knowledge of the distribution and location of space types and applying the space-specific data in the developed database), building-level (assuming a lack of knowledge of the space types and using the building-level data in the developed database), and calculated-ratio (assuming knowledge of the distribution of space types but not their locations and calculating weighted average values based on the space-specific data in the developed database). Finally, the energy results simulated by using these three methods are compared, which show building-level methods can produce energy results up to 20% different than the space-specific methods. Finally, this paper discusses the application scope and maintenance of this new database.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On-policy learning-based deep reinforcement learning assessment for building control efficiency and stability

Artificial intelligence technologies have emerged as a game changer not only in specific applications such as image recognition and machine translation but also in many scientific domains. In particular, as deep reinforcement learning (DRL) has shown great success in complex control problems, DRL-based control has been considered as a potential solution to efficiently control and manage building systems. However, broad assessment of DRL-based building control is still required to characterize their pros and cons in comparison with conventional building control methods (e.g., rule-based feedback controls). In this paper, we assessed DRL-based controls with on-policy learning-based algorithms and continuous control actions for cooling control of large office buildings in the summer season to minimize whole-building energy use and occupant discomfort. We compared DRL-based control methods with two baseline control methods: (1) a pre-determined schedule with supply temperature and static pressure setpoints, and (2) advanced reset method that adjusts setpoints based on heuristic rules, i.e., ASHRAE Guideline 36. We also tested the DRL algorithms to evaluate their performances in multiple climate locations. We found that DRL-based control methods outperformed the baseline control methods in terms of energy savings while maintaining a thermal comfort. DRL reduced energy use between ~4%–22% on average compared to the baseline methods, depending on climate location. We also evaluated DRL-based control in terms of control stability and showed that DRL-based methods should address the span of hardware lifetimes in practical operations.

control stability↗

SysCaps (Language Interfaces for Simulation Surrogates of Complex Systems) [SWR-24-97]

You've found the official code repository for the paper "SysCaps: Language Interfaces for Simulation Surrogates of Complex Systems," presented at the Foundation Models for Science: Progress, Opportunities, and Challenges workshop at NeurIPS 2024. Our paper conjectures that interfaces (both text templates as well as conversational) makes interacting with simulation surrogate models for complex systems more intuitive and accessible for both non-experts and experts. "System captions", or SysCaps, are text-based descriptions of systems based on information contained in simulation metadata. Our paper's goal is to train multimodal regression models that take text inputs (SysCaps) and timeseries inputs (exogenous system conditions such as hourly weather) and regress timeseries simulation outputs (e.g. hourly building energy consumption). The experiments in our paper with building and wind farm simulators, which can be reproduced using this codebase, aim to help us understand whether a) accurate regression in this setting is possible and b) if so, how well can we do it. Paper: https://arxiv.org/abs/2405.19653

Emami, Patrick↗

Developing occupant archetypes within urban low-income housing: A case study in Mumbai, India

Rapid urbanization pressure and poverty have created a push for affordable housing within the global south. The design of affordable housing can have consequences on the thermal (dis)comfort and behaviour of the occupants, hence requiring an occupant-centric approach to ensure sustainability. This paper investigates occupant behaviour within the urban poor households of Mumbai, India and its impact on their thermal comfort and energy use. This study is a first-of-its-kind attempt to explore the socio-demographic characteristics and energy-related behaviour of low-income occupants within Indian context. Three occupant archetypes, Indifferent Consumers; Considerate Savers; and Conscious Conventionals, were identified from the behavioural and psychographic characteristics gathered through a transverse field survey. A two-step clustering approach was adopted for occupant segmentation that highlighted considerable diversity in occupants’ adaptation measures, energy knowledge, energy habits, and their pro-environmental behaviour within similar socio-economic group. Building energy simulation of the representative archetype behaviour estimated up to 37% variations for air-conditioned and up to 8% variation for fan-assisted naturally ventilated housing units during peak summer months. The results from this study establish the significance of occupant factors in shaping energy demand and thermal comfort within low-income housing and pave way for developing occupant-centric building design strategies to serve this marginalized population. The developed low-income occupant archetypes would be useful for architects and energy modelers to generate realistic energy use profiles and improve building performance simulation results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing flexibility for climate change using seasonal energy storage (aquifer thermal energy storage) in distributed energy systems

Long-term energy storage is expected to play a vital role in the deep decarbonization of building energy sectors, while enhancing the flexibility of buildings to withstand future climate variations. However, it is challenging to design distributed multi-energy systems (DMES) while taking into account the uncertainties introduced by climate change, since stochastic optimization of such systems is difficult. The present study introduces a stochastic optimization model to address this bottleneck, taking into account DMES including aquifer thermal energy storage (ATES) as the long-term thermal storage. For the first time, a novel optimization algorithm links ATES with the DMES optimization model with the support of a simplified geotechnical model. Subsequently, a case study was conducted, focusing on a residential district in Chicago where the impact of future climate condition, energy demand, and solar and wind energy potentials were evaluated using Weather Research and Forecasting (WRF) data (up to 2080) and the EnergyPlus model. The study revealed that ATES is an attractive way to improve the renewable energy penetration level and minimize the dependence on fossil fuels with reasonable support from the grid to assist the fluctuations in both demand and generation. Furthermore, ATES notably reduces fuel consumption and dependence while greatly enhancing the flexibility of the energy system to withstand fluctuations in demand and renewable energy generation brought by future climate variations. These qualities will make ATES an important part of distributed energy systems, even though it is not currently the lowest cost alternative due to lack of technology maturity. Furthermore, the design platform introduced in the present study can be used to design DMES enhancing flexibility to accommodate future climate variations.

25 ENERGY STORAGE↗

Understanding Multifamily Energy Use in Florida: Building Stock Segmentation for Retrofit Planning

This report is an addendum to a publication series that focuses on approximately 100 different local geographies, or "clusters". This addendum expands the report series to include large multifamily building characteristics as well as energy and emission data for each local geography. The intention of this addendum is to help policymakers at the city, county, and state levels better understand building energy use and emissions in large multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Shedding light on U.S. small and midsize data centers: Exploring insights from the CBECS survey

As demand for digital services accelerates, the energy and environmental footprint of data centers faces increasing scrutiny. While hyperscale cloud facilities have driven efficiency gains, small and midsize U.S. data centers remain a critical yet underexamined segment with significant untapped potential for energy savings. This study leverages data from the Commercial Buildings Energy Consumption Survey (CBECS) to analyze trends in server stocks, computing customers, cooling system adoption and efficiency, and geospatial distribution from 2012 to 2018. Findings reveal a sharp decline in small and midsize data centers, from 1.764 million to 1.398 million, with server counts dropping from 5.177 million to 4.262 million—aligning with the broader shift toward cloud computing. More than 40 % of servers in small data centers and 55 % in midsize data centers are housed in office buildings, and over half of all servers are concentrated in climate zones 5A (cold), 3A (mixed-humid), and 4A (mixed-humid), with the highest densities in metropolitan hubs. While direct expansion units remain the dominant cooling system, a clear transition toward more energy-efficient solutions, particularly air economizers, is evident. By integrating server and cooling system distributions, we estimate Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) for U.S. data centers by size and year. Results show that midsize data centers are more energy-efficient but more water-intensive due to the widespread use of water-cooled chillers. These findings highlight the trade-offs in cooling system selection and provide a critical foundation for policies aimed at enhancing efficiency in an evolving data center landscape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential Cooling Energy Savings of Economizer Control and Artificial-Neural-Network-Based Air-Handling Unit Discharge Air Temperature Control for Commercial Building

Heating, ventilation, and air-conditioning (HVAC) systems play a significant role in building energy consumption, accounting for around 50% of total energy usage. As a result, it is essential to explore ways to conserve energy and improve HVAC system efficiency. One such solution is the use of economizer controls, which can reduce cooling energy consumption by using the free-cooling effect. However, there are various types of economizer controls available, and their effectiveness may vary depending on the specific climate conditions. To investigate the cooling energy-saving potential of economizer controls, this study employs a dry-bulb temperature-based economizer control approach. The dry-bulb temperature-based control strategy uses the outdoor air temperature as an indicator of whether free cooling can be used instead of mechanical cooling. This study also introduces an artificial neural network (ANN) prediction model to optimize the control of the HVAC system, which can lead to additional cooling energy savings. To develop the ANN prediction model, the EnergyPlus program is used for simulation modeling, and the Python programming language is employed for model development. The results show that implementing a temperature-based economizer control strategy can lead to a reduction of 7.6% in annual cooling energy consumption. Moreover, by employing an ANN-based optimal control of discharge air temperature in air-handling units, an additional 22.1% of cooling energy savings can be achieved. In conclusion, the findings of this study demonstrate that the implementation of economizer controls, especially the dry-bulb temperature-based approach, can be an effective strategy for reducing cooling energy consumption in HVAC systems. Additionally, using ANN prediction models to optimize HVAC system controls can further increase energy savings, resulting in improved energy efficiency and reduced operating costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prevalence of typical operational problems and energy savings opportunities in U.S. commercial buildings

In the United States, as much as 30% of the 19 EJ that commercial buildings consume is considered excess. Much of the excess energy is due to the inability to manage building operations efficiently. Because almost 20% of the total primary energy consumption is associated with commercial buildings, significant energy reductions in this sector are needed to mitigate climate change. Therefore, many cities and states are mandating periodic “tune-ups” of these buildings to eliminate excess energy consumption. Although the benefits of tune-ups and retro-commissioning are clear, focusing these mandates to look for specific opportunities has been a challenge because of the lack of studies that document the prevalence of opportunities. Therefore, we analyzed building automation system data from 151 buildings across the United States to document common operational problems and opportunities to improve building operations. This analysis showed that opportunities to improve building operations exist in almost every building. These opportunities were not strongly correlated with building vintage or size, but were reflective of how the buildings are operated. The prevalence of the top 20 opportunities ranged between 74% and 23%, with 40% of these associated with air-handling units. The rest of the opportunities are associated with schedules, chilled and hot-water distribution, and zone controls. Of the 151 buildings, 69 of them implemented corrective actions of some or all opportunities that were identified. Implementation varied across the Re-tuning categories, with 60% for schedule opportunities, 50% for zone opportunities, over 40% for the air-handling unit and hot-water opportunities, and 35% of the chilled-water opportunities. There was wide variation in whole building energy savings, ranging from 0 to 50% and 0 to 18 $/m2 with median percent annual whole building savings of 12% and median normalized annual cost savings of $1.75/m2. In addition to documenting these key findings, the paper provides a list of opportunities that can be automatically and continuously identified and corrected and offers a list of those opportunities that should be the focus of the mandates.

Katipamula, Srinivas↗