Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “arterial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

A tunnel wick 100,000 watt-inch heat pipe.

The tunnel wick is a new type of heat pipe artery which can prime in a gravity environment by temperature-induced pressure differences between interior and exterior. The paper discusses the concept and its application in the design of room-temperature high-transport-capacity heat pipes. The analytical model of the system is summarized; and performance data obtained with the aid of a related computer program is included. Test data verifying the concept is presented for several pipes, including an eight-foot-long, 0.9-inch ID heat pipe, using ammonia working fluid, with a transport capacity in excess of 150,000 watt-inches. A brief discussion of potential applications for this type of heat pipe includes a variable conductance device to serve as a radiator header and a high capacity heat transport system.

Kosson, R.↗

Advance techniques for monitoring human tolerance to +Gz accelerations.

Standard techniques for monitoring the acceleration-stressed human subject have been augmented by measuring (1) temporal, brachial and/or radial arterial blood flow, and (2) indirect systolic and diastolic blood pressure at 60-sec intervals. Results show that the response of blood pressure to positive accelerations is complex and dependent on an interplay of hydrostatic forces, diminishing venous return, redistribution of blood, and other poorly defined compensatory reflexes.

Pelligra, R.↗

Indirect Blood Pressure Measuring Device

Design and performance of a blood pressure recording device for pediatric use are reported. A strain gage transducer with a copper-beryllium strip as force sensing element is used to monitor skin movements and to convert them into electrical signals proportional to those displacements. Experimental tests with this device in recording of force developed above the left femoral artery of a dog accurately produced a blood pressure curve.

Hum, L.↗

Heat pipe flight experiments

OAO 3 heat pipe flight experiments to check out weightlessness behavior are reported. Tested were a hollow channel screen system with helical grooves, a heat pipe with a wicking system of horizontal grooves, and a spiral artery pipe with multichannel fluid return to the evaporator. Flight experiment data proved that all heat pipe geometries containing wicking systems provided uninterrupted fluid return to the condensators during weightlessness and sufficient cooling for isothermalizing optical instruments onboard OAO.

Ollendorf, S.↗

Land use mapping and change detection using ERTS imagery in Montgomery County, Alabama

The feasibility of using remotely sensed data from ERTS-1 for mapping land use and detecting land use change was investigated. Land use information was gathered from 1964 air photo mosaics and from 1972 ERTS data. The 1964 data provided the basis for comparison with ERTS-1 imagery. From this comparison, urban sprawl was quite evident for the city of Montgomery. A significant trend from forestland to agricultural was also discovered. The development of main traffic arteries between 1964 and 1972 was a vital factor in the development of some of the urban centers. Even though certain problems in interpreting and correlating land use data from ERTS imagery were encountered, it has been demonstrated that remotely sensed data from ERTS is useful for inventorying land use and detecting land use change.

Wilms, R. P.↗

Plasma electrolytes, pH, and ECG during and after exhaustive exercise.

Ten men worked on a bicycle ergometer at increasing work loads to exhaustion in 15 min. Each performed one test breathing air and another with added CO2 in random sequence. ECG was recorded during exercise and for 30 min of recovery. Arterial samples for blood gases, pH, and electrolytes were drawn at rest, in the last minute of exercise and at 1, 4, 10, 20, and 30 min thereafter. A striking increase in the amplitude of T and P waves was observed reaching a maximum in the first 2 min after exercise. All electrolytes measured were increased at the end of exercise, most markedly potassium (60%) and phosphorus (53%). Potassium dropped faster than all others to below resting values in 4 min coinciding with the lowest levels in plasma bicarbonate. ECG alterations were not closely related in time with any single factor such as potassium, but appeared to reflect an interaction of the transient mineral and acid-base imbalance during and immediately following exhaustive exercise.

Coester, N.↗

Video instrumentation for radionuclide angiocardiography.

Two types of videoscintiscopes for performing radioisotopic angiocardiography with a scintillation camera are described, and use of these instruments in performing clinical studies is illustrated. Radionuclide angiocardiography is a simple, quick and accurate procedure recommended as a screening test for patients with a variety of congenital and acquired cardiovascular lesions. When performed in conjunction with coronary arterial catheterization, dynamic radionuclide angiography may provide useful information about regional myocardial perfusion. Quantitative capabilities greatly enhance the potential of this diagnostic tool.

Kriss, J. P.↗

Nonlinear analysis of aortic flow in living dogs.

A nonlinear theory which considered the convective accelerations of blood and the nonlinear elastic behavior and taper angle of the vascular wall was used to study the nature of blood flow in the descending thoracic aorta of living dogs under a wide range of pressures and flows. Velocity profiles, wall friction, and discharge waves were predicted from locally measured input data about the pressure-gradient wave and arterial distention. The results indicated that a major part of the mean pressure gradient was balanced by convective accelerations; the theory, which took this factor into account, predicted the correct velocity distributions and flow waves.

Ling, S. C.↗

Evaluation of a pulsed ultrasonic Doppler flowmeter

The in vivo application of the pulsed ultrasound Doppler velocity meter (PUDVM) for measuring arterial velocity waveforms is reported. In particular, the performance of the PUDVM is compared with a hot film anemometer of proven accuracy.

Wells, M. K.↗

Apparatus and method for processing Korotkov sounds

A Korotkov sound processor, used in a noninvasive automatic blood measuring system where the brachial artery is occluded by an inflatable cuff, is disclosed. The Korotkoff sound associated with the systolic event is determined when the ratio of the absolute value of a voltage signal, representing Korotkov sounds in the range of 18 to 26 Hz to a maximum absolute peak value of the unfiltered signals, first equals or exceeds a value of 0.45. Korotkov sound associated with the diastolic event is determined when a ratio of the voltage signal of the Korotkov sounds in the range of 40 to 60 Hz to the absolute peak value of such signals within a single measurement cycle first falls below a value of 0.17. The processor signals the occurrence of the systolic and diastolic events and these signals can be used to control a recorder to record pressure values for these events.

Golden, D. P., Jr.↗

Heat pipe design handbook, part 2

The utilization of a digital computer code for heat pipe analysis and design (HPAD) is described which calculates the steady state hydrodynamic heat transport capability of a heat pipe with a particular wick configuration, the working fluid being a function of wick cross-sectional area. Heat load, orientation, operating temperature, and heat pipe geometry are specified. Both one 'g' and zero 'g' environments are considered, and, at the user's option, the code will also perform a weight analysis and will calculate heat pipe temperature drops. The central porous slab, circumferential porous wick, arterial wick, annular wick, and axial rectangular grooves are the wick configurations which HPAD has the capability of analyzing. For Vol. 1, see N74-22569.

Skrabek, E. A.↗

Computer model of cardiovascular control system responses to exercise

Approaches of systems analysis and mathematical modeling together with computer simulation techniques are applied to the cardiovascular system in order to simulate dynamic responses of the system to a range of exercise work loads. A block diagram of the circulatory model is presented, taking into account arterial segments, venous segments, arterio-venous circulation branches, and the heart. A cardiovascular control system model is also discussed together with model test results.

Croston, R. C.↗

Role of the cerebellum and the vestibular apparatus in regulation of orthostatic reflexes in the cat

The contribution of the fastigial nucleus and the vestibular nerves (eighth cranial nerves) to the orthostatic reflexes in anesthetized, paralyzed cats was studied. Bilateral lesions of the rostral fastigial nucleus resulted in impairment of the reflex changes in blood pressure, femoral arterial flow, and resistance evoked by head-up tilting to 30 deg or 60 deg. The rostral fastigial nucleus, which might be triggered by the vestibular apparatus, appears to participate in concert with the baroreceptors in the initiation and possibly the maintenance of the orthostatic reflexes.

Doba, N.↗

Communications technology satellite - A variable conductance heat pipe application

A variable-conductance heat pipe system (VCHPS) has been designed to provide thermal control for a transmitter experiment package (TEP) to be flown on the Communications Technology Satellite. The VCHPS provides for heat rejection during TEP operation and minimizes the heat leak during power down operations. The VCHPS described features a unique method of aiding priming of arterial heat pipes and a novel approach to balancing heat pipe loads by staggering their control ranges.

Mock, P. R.↗

Clinical applications of angiocardiography

Several tables are presented giving left ventricular (LV) data for normal patients and patients with heart disease of varied etiologies, pointing out the salient features. Graphs showing LV pressure-volume relationships (compliance) are presented and discussed. The method developed by Rackley et al. (1964) for determining left ventricular mass in man is described, and limitations to the method are discussed. Some clinical methods for determining LV oxygen consumption are briefly described, and the relation of various abnormalities of ventricular performance to coronary artery disease and ischemic heart disease is characterized.

Dodge, H. T.↗

Catheter-tip force transducer for cardiovascular research

Sensor can be installed in left ventricle by means of procedures available for inserting catheter into an artery at body's extremities and manipulating it through vessel and past aortic valve. Metallic tines of device can be used as internal electrode for electrocardiogram.

Feldstein, C.↗

Lower body negative pressure: Third manned Skylab mission

The crew of the Skylab 4 Mission exhibited physiological changes during their 84-day mission that resembled but in several important areas did not reach the magnitude of changes exhibited in crewmen of the two earlier Skylab flights. At rest all three crewmen showed, in comparison to preflight levels, elevated mean systolic and pulse pressures and decreased mean diastolic and mean arterial pressures. Similar changes were seen in most Skylab 2 and Skylab 3 crewmen. While mean resting heart rates of both the Skylab 3 and Skylab 4 crews were elevated, those of the Skylab 2 crew were, however, lower than during preflight tests. Stressed heart rates followed previous patterns in being consistently elevated over preflight values. Postflight changes in cardiovascular parameters for the most part resembled those seen in previous crewmen of space missions. Their recovery to preflight limits occurred rapidly. In-flight data and subjective impressions of the crewmen confirmed that lower body negative pressure in weightlessness imposed a greater stress upon the cardiovascular system than in earth's gravity.

Johnson, R. L.↗

Hemodynamic studies of the legs under weightlessness

Following exposure to weightlessness, alterations in the return of blood from the legs play a crucial role in orthostatic tolerance and may be an important factor in work tolerance. To investigate some of the hemodynamic mechansism involved, an experiment was performed on the Skylab 3 and Skylab 4 missions to study arterial blood flow, venous compliance, and muscle pumping of blood. Skylab 4 results indicated that the most likely cause of increased blood flow was an increase in cardiac output secondary to increased central venous pressure caused by blood redistribution. Changes in venous compliance are thought to be primarily changes in somatic musculature which is postulated to primarily determine venous compliance of the legs. This was also thought to be demonstrated by the changes in muscle pumping. It is thought that these compliance changes, when taken with the decreased blood volume; provide a basis for the changes seen in orthostatic tolerance, work capacity and lower body negative pressure response.

Thornton, W. E.↗