Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “air conditioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

THE ECONOMIC EFFECTS OF THE SPACE PROGRAM

The purpose of this paper is to discuss the economic impact of the amazing space program presented in the preceding papers. My function is to view the space program objectively as an economist so as to assess its impact upon the Nation's economy as a whole and upon certain regions in particular. In order to be objective, I will not take the extreme view that our entire lives will be changed by this program overnight-we will not all be wearing air-conditioned Moonsuits in 2 years and commuting to work by individual miniaturized Rocketpacks. An attempt will be made to avoid the other extreme of thinking that the space program is the greatest boondoggle since the Pyramids; it is not merely a form of scientific leaf-raking on a gigantic scale. My definition of the space program includes the program of the National Aeronautics and Space Administration (NASA) and some work of other agencies doing related space exploration, particularly the Department of Defense. In essence, I hope to answer the question: What will NASA's program mean to the participants in the Nation's economy?

ECONOMICS↗

New nut and sleeve improve flared connections

Improved nut and sleeve of standard stainless steel flared tube connection allows forces on the mating surfaces to be uniformly applied. This can be applied to pressurized fluid systems such as refrigeration, air conditioning, and hydraulic systems.

Garrard, J. S.↗

Safe Flight in Rough Air

Commentary on safe flight under turbulent air conditions by military and commercial aircraft

FLIGHT SAFETY↗

Electrolysis cell functions as water vapor dehumidifier and oxygen generator

Water vapor is absorbed in hygroscopic electrolyte, and oxygen generated by absorbed water electrolysis at anode is added simultaneously to air stream. Cell applications include on-board aircraft oxygen systems, portable oxygen generators, oxygen concentration requirements, and commercial air conditioning and dehumidifying systems.

Clifford, J. E.↗

Space station ventilation study

A ventilation system design and selection method which is applicable to any manned vehicle were developed. The method was used to generate design options for the NASA 33-foot diameter space station, all of which meet the ventilation system design requirements. System characteristics such as weight, volume, and power were normalized to dollar costs for each option. Total system costs for the various options ranged from a worst case $8 million to a group of four which were all approximately $2 million. A system design was then chosen from the $2 million group and is presented in detail. A ventilation system layout was designed for the MSFC space station mockup which provided comfortable, efficient ventilation of the mockup. A conditioned air distribution system design for the 14-foot diameter modular space station, using the same techniques, is also presented. The tradeoff study resulted in the selection of a system which costs $1.9 million, as compared to the alternate configuration which would have cost $2.6 million.

Colombo, G. V.↗

A practical solar energy heating and cooling system

Recent study has concluded that solar-powered residential heating and cooling system is non technically and economically feasible. Proposed system provides space heating, air conditioning, and hot water. Installation costs will be greater than for conventional heating systems, but this difference will eventually be defrayed by very low operating costs.

Oneill, M. J.↗

The development of a residential heating and cooling system using NASA derived technology

A study to determine the technical and economic feasibility of a solar-powered space heating, air-conditioning, and hot water heating system for residential applications is presented. The basic system utilizes a flat-plate solar collector to process incident solar radiation, a thermal energy storage system to store the collected energy for use during night and heavily overcast periods, and an absorption cycle heat pump for actually heating and cooling the residence. In addition, heat from the energy storage system is used to provide domestic hot water. The analyses of the three major components of the system (the solar collector, the energy storage system, and the heat pump package) are discussed and results are presented. The total system analysis is discussed in detail, including the technical performance of the solar-powered system and a cost comparison between the solar-powered system and a conventional system. The projected applicability of the system to different regions of the nation is described.

Oneill, M. J.↗

The NASA Langley building solar project and the supporting Lewis solar technology program

The use of solar energy to heat and cool a new office building that is now under construction is reported. Planned for completion in December 1975, the 53,000 square foot, single story building will utilize 15,000 square feet of various types of solar collectors in a test bed to provide nearly all of the heating demand and over half of the air conditioning demand. Drawing on its space-program-developed skills and resources in heat transfer, materials, and systems studies, NASA-Lewis will provide technology support for the Langley building project. A solar energy technology program underway at Lewis includes solar collector testing in an indoor solar simulator facility and in an outdoor test facility, property measurements of solar panel coatings, and operation of a laboratory-scale solar model system test facility. Based on results obtained in this program, NASA-Lewis will select and procure the solar collectors for the Langley test bed.

Ragsdale, R. G.↗

A new technique for inducing a turbulent boundary layer in a supersonic flow

The feasibility of using slot injection to establish a turbulent boundary layer corresponding to a known Reynolds number was investigated. The basic concept consists of injecting secondary air through a slot. The air is injected at the same local static pressure at a selected stagnation temperature to simulate a given up-stream heat conduction. The mass of the injected air is controlled to match a desired Reynolds number. Secondary air was injected through a supersonic nozzle over a flat plate model. Tests were conducted with different injection air conditions. Heat transfer rates were measured behind the slot and results were compared with theoretical estimates. Static pressure measurements were made over the surface in the streamwise direction. Velocity and Mach number profiles were determined downstream of the slot. Laminar and turbulent profiles were calculated to compare with the results of measurements. Experimental results indicate that this is an effective method for establishing a turbulent boundary layer having a prescribed value of R sub e Theta.

Miyazawa, M.↗

One man electrochemical air revitalization system

An integrated water vapor electrolysis (WVE) hydrogen depolarized CO2 concentrator (HDC) system sized for one man support over a wide range of inlet air conditions was designed, fabricated, and tested. Data obtained during 110 days of testing verified that this system can provide the necessary oxygen, CO2 removal, and partial humidity control to support one man (without exceeding a cabin partial pressure of 3.0 mmHg for CO2 and while maintaining a 20% oxygen level), when operated at a WVE current of 50 amperes and an HDC current of 18 amperes. An evaluation to determine the physical properties of tetramethylammonium bicarbonate (TMAC) and hydroxide was made. This provides the necessary electrolyte information for designing an HDC cell using TMAC.

Huddleston, J. C.↗

Solar energy: Technology and applications

It is pointed out that in 1970 the total energy consumed in the U.S. was equal to the energy of sunlight received by only 0.15% of the land area of the continental U.S. The utilization of solar energy might, therefore, provide an approach for solving the energy crisis produced by the consumption of irreplaceable fossil fuels at a steadily increasing rate. Questions regarding the availability of solar energy are discussed along with the design of solar energy collectors and various approaches for heating houses and buildings by utilizing solar radiation. Other subjects considered are related to the heating of water partly or entirely with solar energy, the design of air conditioning systems based on the use of solar energy, electric power generation by a solar thermal and a photovoltaic approach, solar total energy systems, industrial and agricultural applications of solar energy, solar stills, the utilization of ocean thermal power, power systems based on the use of wind, and solar-energy power systems making use of geosynchronous power plants.

Williams, J. R.↗

Development of minimum correction wind tunnels

Flow distortions due to wind tunnel wall interference may be accounted for if the model to tunnel ratio is small, but the theory becomes less reliable as the model becomes larger. This paper presents theoretical analysis and experimental evidence which supports a new concept of wind tunnel. The method employs active control of flow through the walls so that the model is in approximately free air conditions during the test. Practical considerations in the design of such a tunnel are presented. Results indicate that a minimum correction wind tunnel may be achieved with active walls of relatively low porosity.

Bernstein, S.↗

Computer simulation of thermal and fluid systems for MIUS integration and subsystems test /MIST/ laboratory

This paper describes the application of the SINDA (systems improved numerical differencing analyzer) computer program to simulate the operation of the NASA/JSC MIUS integration and subsystems test (MIST) laboratory. The MIST laboratory is designed to test the integration capability of the following subsystems of a modular integrated utility system (MIUS): (1) electric power generation, (2) space heating and cooling, (3) solid waste disposal, (4) potable water supply, and (5) waste water treatment. The SINDA/MIST computer model is designed to simulate the response of these subsystems to externally impressed loads. The computer model determines the amount of recovered waste heat from the prime mover exhaust, water jacket and oil/aftercooler and from the incinerator. This recovered waste heat is used in the model to heat potable water, for space heating, absorption air conditioning, waste water sterilization, and to provide for thermal storage. The details of the thermal and fluid simulation of MIST including the system configuration, modes of operation modeled, SINDA model characteristics and the results of several analyses are described.

Rochelle, W. C.↗

Wind velocity measurement

Homodyne laser-Doppler system determines three-component wind velocity at altitudes of several kilometers in clear-air conditions. There is no need for deployment of towers, radiosondes, or for seeding airflows.

Cliff, W. C.↗

Velocity sensor for slow flows

Inexpensive, easily-constructed device measures flows from 0.2 to 20 feet per second. Instrument is capable of measuring flow velocity and direction in cases where either velocity or density is so low that dynamic pressure is below measurable range. It can be made into hand held instrument for measuring ventilation and air conditioning flow.

Simon, W. E.↗

Vehicle for civil helicopter ride quality research

A research aircraft for investigating the factors involved in civil helicopter operations was developed for NASA Langley Research Center. The aircraft is a reconfigured 17000 kg (36000 lb) military transport helicopter. The basic aircraft was reconfigured with advanced acoustic treatment, air-conditioning, and a 16-seat airline cabin. During the spring of 1975, the aircraft was flight tested to measure interior environment characteristics - noise and vibration - and was flown on 60 subjective flight missions with over 600 different subjects. Data flights established noise levels somewhat higher than expected, with a pure tone at 1400 Hz and vertical vibration levels between 0.07g and 0.17g. The noise and vibration levels were documented during subjective flight evaluations as being the primary source of discomfort. The aircraft will be utilized to document in detail the impact of various noise and vibration levels on passenger comfort during typical short-haul missions.