Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Use of collateral information to improve LANDSAT classification accuracies

Methods to improve LANDSAT classification accuracies were investigated including: (1) the use of prior probabilities in maximum likelihood classification as a methodology to integrate discrete collateral data with continuously measured image density variables; (2) the use of the logit classifier as an alternative to multivariate normal classification that permits mixing both continuous and categorical variables in a single model and fits empirical distributions of observations more closely than the multivariate normal density function; and (3) the use of collateral data in a geographic information system as exercised to model a desired output information layer as a function of input layers of raster format collateral and image data base layers.

Strahler, A. H.↗

Geometric accuracy of LANDSAT-4 MSS image data

Analyses of the LANDSAT-4 MSS image data of North Georgia provided by the EDC in CCT-p formats reveal that errors of approximately + or - 30 m in the raw data can be reduced to about + or - 55 m based on rectification procedures involving the use of 20 to 30 well-distributed GCPs and 2nd or 3rd degree polynomial equations. Higher order polynomials do not appear to improve the rectification accuracy. A subscene area of 256 x 256 pixels was rectified with a 1st degree polynomial to yield an RMSE sub xy value of + or - 40 m, indicating that USGS 1:24,000 scale quadrangle-sized areas of LANDSAT-4 data can be fitted to a map base with relatively few control points and simple equations. The errors in the rectification process are caused by the spatial resolution of the MSS data, by errors in the maps and GCP digitizing process, and by displacements caused by terrain relief. Overall, due to the improved pointing and attitude control of the spacecraft, the geometric quality of the LANDSAT-4 MSS data appears much improved over that of LANDSATS -1, -2 and -3.

Welch, R.↗

An evaluation of LANDSAT-4 thematic mapper data for their geometric and radiometric accuracies and their relevance to geologic mapping

Thematic mapper scenes for Washington, D.C. and Macon, Georgia were examined to determine their radiometry and geometric accuracy. Specific band ratios were used to determine their effectiveness in defining vegetation and rock mineralogy. the TM 3/4 band ratio was used to define vegetation and the 5/2 band ratio was used to define limonitic rocks. The 5/7 band ratio was evaluated to test the effectiveness of the 1.6 and 2.2 mm bands in detecting clay and carbonate bearing rocks. Preliminary results show that clay minerals containing absorption bands at 2.2 mm, which are centered in the TM band 7, can be readily detected when the band ratio images are suitably contrast stretched. Bright rocks, such as marbles, which contain absorption bands in the 2.33 mm region, near the wavelength of TM band 7, are only evident upon harsher contrast stretching of the 5/7 band ratio. Geobotanical studies of Washington, D.C. show that monospecific forest canopies can be differentiated.

Bender, L. U.↗

The NASA High Accuracy Fuel Flowmeter (HAFF) Development Program

The high accuracy fuel flowmeter development program is described. A flightworthy meter that measures mass flowrate of aircraft fuels to within + or - 0.25% of reading over a 50:1 range of flow is developed. A study of measurement techniques to achieve this goal yielded three candidates: (1) a dual turbine flowmeter with density and viscosity compensation; (2) an angular momentum flowmeter with a motor-driven, spring-restrained turbine and viscosity shroud; and (3) a vortex precission flowmeter with density and viscosity compensation. An experimental study of each technique was completed and the first two candidates were selected for prototype development.

Hobart, H. F.↗

An investigation of the accuracy of finite difference methods in the solution of linear elasticity problems

The accuracy of the finite difference method in the solution of linear elasticity problems that involve either a stress discontinuity or a stress singularity is considered. Solutions to three elasticity problems are discussed in detail: a semi-infinite plane subjected to a uniform load over a portion of its boundary; a bimetallic plate under uniform tensile stress; and a long, midplane symmetric, fiber reinforced laminate subjected to uniform axial strain. Finite difference solutions to the three problems are compared with finite element solutions to corresponding problems. For the first problem a comparison with the exact solution is also made. The finite difference formulations for the three problems are based on second order finite difference formulas that provide for variable spacings in two perpendicular directions. Forward and backward difference formulas are used near boundaries where their use eliminates the need for fictitious grid points.

Bauld, N. R., Jr.↗

The use of LANDSAT-4 MSS digital data in temporal data sets and the evaluation of scene-to-scene registration accuracy

The MSS sensor on LANDSAT 4 is, in certain performance aspects, different from those on LANDSATS 1 through 3. These differences created some concern in the NASA research community as to whether individual data sets can be registered accurately enough to produce acceptable data sets for multitemporal data analysis. The use of LANDSAT 4 MSS digital data in temporal data sets is examined and a method is presented for estimating temporal registration accuracy based on the use of an X-Y digitizer and grey tone electrostatic plots. Results indicate that the RMS temporal registration errors are not significantly different from the temporal data sets generated using LANDSAT 4 and LANDSAT 2 data (33.35 meters) and the temporal data set constructed from two LANDSAT 2 data sets (33.61 meters). A derivation of the model used to evaluate the temporal registration is included.

Anderson, J. E.↗

Evaluation of factors determining the accuracy of linearized subsonic panel methods

A systematic evaluation of the factors determining the accuracy of linearized subsonic panel methods is presented. In particular, the constant and quadratically varying doublet panel methods are compared for thin and thick surface modelings in two and three dimensions. The sensitivity of results to panel edge and control point locations is studied for both of the methods. The first order convergence of the quadratic doublet method near network edges and the subsequent effect on the Kutta condition is investigated. Results from a quadratic doublet method specifically designed for a vector processing computer are shown.

Thomas, J. L.↗

Assessment of relative error sources in IR DIAL measurement accuracy

An assessment is made of the role the various error sources play in limiting the accuracy of infrared differential absorption lidar measurements used for the remote sensing of atmospheric species. An overview is presented of the relative contribution of each error source including the inadequate knowledge of the absorption coefficient, differential spectral reflectance, and background interference as well as measurement errors arising from signal fluctuations.

Menyuk, N.↗

Measuring Tracking Accuracy of CCD Imagers

Tracking accuracy and resolution of charge-coupled device (CCD) imaging arrays measured by instrument originally developed for measuring performance of star-tracking telescope. Operates by projecting one or more artifical star images on surface of CCD array, moving stars in controlled patterns, and comparing star locations computed from CCD outputs with those calculated from step coordinates of micropositioner.

Stanton, R. H.↗

Aerodynamic coefficient identification package dynamic data accuracy determinations: Lessons learned

The errors in the dynamic data output from the Aerodynamic Coefficient Identification Packages (ACIP) flown on Shuttle flights 1, 3, 4, and 5 were determined using the output from the Inertial Measurement Units (IMU). A weighted least-squares batch algorithm was empolyed. Using an averaging technique, signal detection was enhanced; this allowed improved calibration solutions. Global errors as large as 0.04 deg/sec for the ACIP gyros, 30 mg for linear accelerometers, and 0.5 deg/sec squared in the angular accelerometer channels were detected and removed with a combination is bias, scale factor, misalignment, and g-sensitive calibration constants. No attempt was made to minimize local ACIP dynamic data deviations representing sensed high-frequency vibration or instrument noise. Resulting 1sigma calibrated ACIP global accuracies were within 0.003 eg/sec, 1.0 mg, and 0.05 deg/sec squared for the gyros, linear accelerometers, and angular accelerometers, respectively.

Heck, M. L.↗

Update and review of accuracy assessment techniques for remotely sensed data

Research performed in the accuracy assessment of remotely sensed data is updated and reviewed. The use of discrete multivariate analysis techniques for the assessment of error matrices, the use of computer simulation for assessing various sampling strategies, and an investigation of spatial autocorrelation techniques are examined.

Congalton, R. G.↗

Analysis of Subpixel Registration Accuracy

Geometric and probabilistic models for subpixel accuracy are developed. The geometric models bound the error in offset estimation using the pixels in an observed digital straight line. One probabilistic model bounds the estimate of error offset for continuous images. The other model bounds the error for discrete images given that one is in the correct pixel.

Lavine, D.↗

An assessment of the accuracy of orthotropic photoelasticity

The accuracy of orthotropic photoelasticity was studied. The study consisted of both theoretical and experimental phases. In the theoretical phase a stress-optic law was developed. The stress-optic law included the effects of residual birefringence in the relation between applied stress and the material's optical response. The experimental phase had several portions. First, it was shown that four-point bending tests and the concept of an optical neutral axis could be conveniently used to calibrate the stress-optic behavior of the material. Second, the actual optical response of an orthotropic disk in diametral compression was compared with theoretical predictions. Third, the stresses in the disk were determined from the observed optical response, the stress-optic law, and a finite-difference form of the plane stress equilibrium equations. It was concluded that orthotropic photoelasticity is not as accurate as isotropic photoelasticity. This is believed to be due to the lack of good fringe resolution and the low sensitivity of most orthotropic photoelastic materials.

Hyer, M. W.↗

An evaluation of the accuracy of some radar wind profiling techniques

Major advances in Doppler radar measurement in optically clear air have made it feasible to monitor radial velocities in the troposphere and lower stratosphere. For most applications the three dimensional wind vector is monitored rather than the radial velocity. Measurement of the wind vector with a single radar can be made assuming a spatially linear, time invariant wind field. The components and derivatives of the wind are estimated by the parameters of a linear regression of the radial velocities on functions of their spatial locations. The accuracy of the wind measurement thus depends on the locations of the radial velocities. The suitability is evaluated of some of the common retrieval techniques for simultaneous measurement of both the vertical and horizontal wind components. The techniques considered for study are fixed beam, azimuthal scanning (VAD) and elevation scanning (VED).

Koscielny, A. J.↗

Improvements to the Photometric response and positional accuracy of the Yale PDS 2020G microdensitometer

The necessity to incorporate several hardware changes to optimize the Yale PDS 2020G microdensitometer for photometric and astrometric research are discussed. The properties of a new high speed photometer and a positional calibration system are described. The new photometer incorporates a high speed logarithmic analog to digital converter with more than 10 times the resolution of the former system and a cycle time of approximately 50 usec. The positional calibration system monitors the drunkenness of the stages with respect to fixed index lines and enables the correction of the +/- 5 micro stage errors to an accuracy of better than 1 micro.

Lee, J. F.↗

LANDSAT Scene-to-scene Registration Accuracy Assessment

Initial results obtained from the registration of LANDSAT-4 data to LANDSAT-2 MSS data are documented and compared with results obtained from a LANDSAT-2 MSS-to-LANDSAT-2 scene-to-scene registration (using the same LANDSAT-2 MSS data as the base data set in both procedures). RMS errors calculated on the control points used in the establishment of scene-to-scene mapping equations are compared to error computed from independently chosen verification points. Models developed to estimate actual scene-to-scene registration accuracy based on the use of electrostatic plots are also presented. Analysis of results indicates a statistically significant difference in the RMS errors for the element contribution. Scan line errors were not significantly different. It appears that a modification to the LANDSAT-4 MSS scan mirror coefficients is required to correct the situation.

Anderson, J. E.↗

Geometric Accuracy of LANDSAT-4 MSS Image Data

Analyses of the LANDSAT-4 MSS image data of North Georgia provided by the EDC in CTT-p formats reveal that errors of approximately + or - 30 m in the raw data can be reduced to about + or - 55 m based on rectification procedures involving the use of 20 to 30 well-distributed GCPs and 2nd or 3rd degree polynomial equations. Higher order polynomials do not appear to improve the rectification accuracy. A subscene area of 256 by 256 pixels was rectified with a 1st degree polynomial to yield an RMSE sub xy value of + or - 40 m, indicating that USGS 1:24,000 scale quadrangle-sized areas of LANDSAT-4 data can be fitted to a map base with relatively few control points and simple equations. The errors in the rectification process are caused by the spatial resolution of the MSS data, by errors in the maps and GCP digitizing process, and by displacements caused by terrain relief. Overall, due to the improved pointing and attitude control of the spacecraft, the geometric quality of the LANDSAT-4 MSS data appears much improved over that of LANDSAT-1, -2 AND -3.

Welch, R.↗