At least 613 records · Page 34

Low-level water vapor fields from the VISSR atmospheric sounder (VAS) split window channels at 11 and 12 microns

A series of high-resolution water vapor fields were derived from the 11 and 12 micron channels of the VISSR Atmospheric Sounder (VAS) on GOES-5. The low-level tropospheric moisture content was separated from the surface and atmospheric radiances by using the differential adsorption across the 'split window' along with the average air temperature from imbedded radiosondes. Fields of precipitable water are presented in a time sequence of five false color images taken over the United States at 3-hour intervals. Vivid subsynoptic and mesoscale patterns evolve at 15 km horizontal resolution over the 12-hour observing period. Convective cloud formations develop from several areas of enhanced low-level water vapor, especially where the vertical water vapor gradient relatively strong. Independent verification at radiosonde sites indicates fairly good absolute accuracy, and the spatial and temporal continuity of the water vapor features indicates very good relative accuracy. Residual errors are dominated by radiometer noise and unresolved clouds.

Chesters, D.↗

A New Process for Carbon Dioxide Conversion to Fuel

In this project, TDA developed a new mixed metal oxide-based sorbent that converts CO 2 (captured from coal fired power plant) to CO, which can then be combined with renewable H 2 generated by water electrolysis to produce different liquid fuels. TDA’s absorbent-based CO 2 conversion process uses a redox process, which splits the reverse water gas shift reaction steps into two stages: CO 2 reduction to CO and H 2 oxidation to H 2 O and eliminates the equilibrium limitations. The CO produced in the two-stage reactor system can then be further reacted with renewable H 2 to produce methanol, naphtha, diesel, or gasoline. We worked with the Gas Technology Institute (GTI) and Advanced Power & Energy Program (APEP) of University of California, Irvine (UCI) to design and develop the liquid fuel synthesis process that is built around this new material. We demonstrated the techno-economic viability of the new sorbent based redox process to convert CO 2 into synthesis gas by: 1) demonstrating continuous carbon dioxide reduction in a prototype test system for over 500 hours while converting up to 0.4 kg CO 2 /day. With the successful completion of the R&D effort, the technology is now ready for a larger pilot-scale demonstration and the technology readiness has been raised from TRL 3 to TRL 5. In collaboration UCI, we also completed a high-fidelity process design and economic analysis. The required selling price (RSP) for methanol (Case 1 H2-MeOH) is $\$$3.06/gal, naphtha and diesel (Case 2 H2-FT) are $\$$6.21/gal and $\$$8.91/gal, and for gasoline (Case 3 H2-MTG) is $\$$6.96/gal on a 2011 dollar basis. To put these costs in perspective, the recent (June 2020) U.S. price for methanol made from natural gas is about $\$$1.19/gal according to Methanex, a major methanol producer in North America. The recent (June 2, 2020) California prices for gasoline and diesel with California’s strict specifications are $\$$3.35/gal and $\$$3.73/gal according to the U.S. Energy Information Agency. On the other hand, it should be noted that the gasoline and diesel produced by the designs of Case 2 and Case 3 would be both nitrogen and sulfur free. These RSPs are based on a cost of imported electricity of $\$$64/MWh based on the low-end current wind generated electricity cost (Genevieve and Ramsden, Wind Electrolysis: Hydrogen Cost Optimization, Technical Report, June 2011, NREL/TP-5600-50408). This cost is by far the largest component of the variable costs used in computing the RSPs. The cost of the imported electricity has to approach zero for the RSP to be competitive for methanol produced in Case 1 and naphtha and diesel produced in Case 2 while the cost of electricity has to be less than $\$$10/MWh for gasoline produced in Case 3.

01 COAL, LIGNITE, AND PEAT↗

Low level water vapor fields from the VISSR Atmospheric Sounder (VAS) 'split window' channels

The use of the 11 and 12-micron IR-radiometer channels of the VISSR Atmosphere Sounder (VAS) on the GOES to detect water vapor in the lowest 300-400 mb of the troposphere is reported. An algorithm is developed to eliminate the background temperature, allowing the calculation of precipitable water (PW) over both land and water via a single-layer radiative model. This 'split-window' method is demonstrated in a case study, covering the US on July 13, 1981. PW values were calculated from five VAS images and compared with those from radiosonde data and surface measurements. It is shown that the VAS PW images have good resolution (15 km), reveal vivid, continuously evolving details, and differentiate deep, convection-supporting layers from shallow ones. PW ranged from 1.7 to 5.5 g/sq cm (+ or - 1.0 g/sq cm), in good agreement with other measurements. Since this method can detect mesoscale water-vapor fields in relatively clear air, it is considered of great potential value for numerical forecasting.

Robinson, W. D.↗

The role of water vapor during the synthesis of hydrogen doped In 2 O 3

Hydrogen-doped In 2 O 3 synthesized using magnetron sputtering or atomic layer deposition in the presence of water vapor has high transparency in the near infra-red region and mobility values that are almost three to four times of those in commercially used In 2 O 3 :Sn at a much lower carrier concentration. However, simple questions like what happens when water molecules enter In 2 O 3 or why the dominant charge carrier changes from an oxygen vacancy in In 2 O 3 :Sn to H + in In 2 O 3 are not clear. Using hybrid functional based density functional theory calculations, in this study we show that water molecules spontaneously split into H + and OH – . The H + interstitial bonds with an oxygen in In 2 O 3 , and the OH – interstitial occupies a vacant lattice site or is trapped by an oxygen vacancy. Thus, in agreement with experimental findings, our results suggest that the concentration of oxygen vacancies decreases as the partial pressure of water increases. The charge transition level, ϵ ( – / + ) , of a hydrogen interstitial and the Fermi level at which the formation energies of OH – and H + are equal lie above the conduction band minimum, suggesting that the H + interstitial has a lower formation energy. In addition, water molecules do not exhibit any propensity to form clusters, meaning that H + ions can diffuse and remain spatially separated from each other.

36 MATERIALS SCIENCE↗

Approaches for Water Removal in Direct-Fired sCO 2 Power Cycles

There is interest in investigation of water removal processes in direct fired sCO 2 flows, as this may potentially lead to greater system efficiency as the removal of this contaminant will result in sCO 2 behaving close to idealized behaviors. Water removal should be split into a two-step process, condensation of the water, followed by separation of the liquid phase water from the sCO 2 . The two main avenues of condensation are manipulation of pressure and temperature for phase change. For this paper, temperature-based phase change is the primary focus through the implementation of heat exchangers. Of the heat exchangers investigated it was found that printed circuit heat exchangers (PCHEs) could be an alternative for this use case, though the specific design of flow channel geometry and flow direction depends on the specific system case and cannot be determined at this point. For water separation there were four processes identified, all of which already assume water is in liquid phase at that point in the system. Of these separation avenues the best candidate is the hydrocyclone as it has a proven history of separating liquid-liquid phase mixtures with small density differences in oilfield use, in addition they have been investigated and modeled specifically for water separation for sCO 2 flows and the footprint is relatively small.

20 FOSSIL-FUELED POWER PLANTS↗

A novel lung-inspired 3D-printed desiccant-coated heat exchanger for high-performance humidity management in buildings

Offering an independent humidity management method for buildings, desiccant-coated heat exchangers (DCHXs) are deemed a promising approach to improve the overall energy efficiency of air conditioning (AC) systems. State-of-the-art DCHXs, however, are bound with conventional HX topologies either providing limited desiccant-air interfacial areas or introducing excessive pressure drop penalties. In this paper a novel 3D-printed DCHX concept inspired by the bronchi arrangement of a human lung is introduced to address the shortcomings inherent in existing DCHX designs. The proposed lung-inspired DCHX utilizes two intertwined bicontinuous flow networks enabling highly efficient heat and mass transfer characteristics for augmented adsorption and regeneration processes at low pressure drop penalties. While the first network evenly distributes an incoming air stream through the entire volume of the lung-inspired DCHX, the second network volumetrically splits a cooling water stream within and through the first network. Effects of various parameters including air flow rate, outdoor air humidity ratio, and regeneration temperature on dehumidification performance and energy efficiency of the proposed lung-inspired DCHX were investigated. Experimental results indicated the proposed lung-inspired 3D-printed DCHX outperforms existing DCHX systems by demonstrating an excellent balance between a high volumetric adsorption rate and a low pressure drop penalty. The volumetric adsorption rate of the proposed lung-inspired DCHX technology is 54.8 g/m 3 -s, a more than two-fold improvement compared with state-of-the-art DCHX systems. Additionally, the lung-inspired DCHX offers high thermal energy efficiency of 56% at a low regeneration temperature of 40 °C. Therefore, the proposed lung-inspired 3D-printed DCHX offers a new solid-desiccant-based air dehumidification pathway for next-generation high-performance AC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evidence for Liquid Water on Comets

We have reexamined the arguments for the existence of liquid water on comets, and believe that recent cometary flybys along with pre-Giotto data support its presence on short-period comets. Liquid water would affect cometary dynamics, leaving distinct signatures in precession, orbital dynamics, and potential splitting of comets. Liquid water geysers would affect cometary atmosphere, dust evolution, and non-gravitational forces that perturb the orbit. Liquid water would affect the composition of both the interior and exterior of the comet, producing geologic effects consistent with recent flyby photographs. And most importantly, liquid water suppork the growth of lifeforms, which would make a comet a biofriendly incubator for interplanetary transport. The major objection against liquid water is the necessity of a pressure vessel to prevent sublimation into space. We discuss how such a pressure vessel could naturally evolve as a pristine comet makes its first journey inside the orbit of Mars, and suggest that this type of vessel was observed by Giotto, Deep Space I, and Stardust.

Sheldon, Robert↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters

A quarter of all housing units in the United States are found in multifamily buildings, but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single-family homes are often a poor fit for individual multifamily units because the water heaters are often located in small internal closets. This confined space can limit the airflow to the heat pump, and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

A technique for determining cloud free vs cloud contaminated pixels in satellite imagery

Since the first earth orbiting satellite sent pictures of the earth back to them, atmospheric scientists have been focused on the possibilities of using that information as both a forecasting tool and as a meteorological research tool. With the latest generation of Geostationary Operational Environmental Satellites (GOES) now entering service, that view of the earth yields views at a frequency and resolution never before available. These satellites have imagers with a five band multi-spectral capability with high spatial resolution. In addition, the sounder has eighteen thermal infrared (IR) channels plus one low-resolution visible band. With a resolution as small as one kilometer, GOES provides scientists with a powerful eye on the atmosphere. Menzel and Purdom (1994) detail both the imager and sounder capability as well as other systems on the GOES satellites. Immediately apparent in the visible channel are the patterns of clouds swirling over both oceans and continents. These clouds range in size from huge planetary systems covering thousands of kilometers to puffy fair weather cumulus clouds on the order of half a kilometer in size. With the IR sensors temperature patterns are observed. High clouds appear very cold, while low stratus field show temperatures near that of the surface. The surface, in turn, generally appears warmer than the clouds. It would seem then a simple manner to determine cloud and surface temperature from the imagery, but such is not the case. While most of the atmospheric constituents are well mixed and homogeneous, water vapor is not. The water molecule, because of its unique structure and vibration modes, affects the transmittance of the atmosphere most notably in the infrared regions. There are regions of the IR spectrum where water vapor acts as a strong absorber, and at others it is nearly transparent. The transparent wavelengths are called windows, and one such window occurs at 11.2 microns. Adjacent to this window at 12.7 microns which is strongly absorbed by water vapor. These two wavelengths form what is known as a split window, the utility of which was used. Using the linearized form of the radiative transfer equation, they were able to use the split window to determine the amount of water vapor present in the atmosphere. Jedlovec developed the physical split-window (PSW) technique which determines the integrated water content (IWC). The PSW method using Visible Infrared Spin Scan Radiometer (VISSR) Atmospheric Sounder (VAS) found on the older versions of the GOES satellites was used. Recently, Jedlovec and colleagues have been attempting to apply the PSW method using full disk IR imagery obtained by the new generation of GOES satellites. IWC is essential for improved analysis and prediction of convective storms which have been observed to develop in regions of both strong and rapidly evolving moisture gradients. It has also been used in the prediction of clouds and precipitation.

Wohlman, Richard A.↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters: Preprint

A quarter of all housing units in the country are found in multifamily buildings but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single family homes are often a poor fit for individual multifamily units since the water heaters are often located in small internal closets. This confined space can limit the air flow to the heat pump and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

Perovskite-driven solar C 2 hydrocarbon synthesis from CO 2

Photoelectrochemistry (PEC) presents a direct pathway to solar fuel synthesis by integrating light absorption and catalysis into compact electrodes. Yet, PEC hydrocarbon production remains elusive due to high catalytic overpotentials and insufficient semiconductor photovoltage. Here we demonstrate ethane and ethylene synthesis by interfacing lead halide perovskite photoabsorbers with suitable copper nanoflower electrocatalysts. The resulting perovskite photocathodes attain a 9.8% Faradaic yield towards C 2 hydrocarbon production at 0 V against the reversible hydrogen electrode. The catalyst and perovskite geometric surface areas strongly influence C 2 photocathode selectivity, which indicates a role of local current density in product distribution. The thermodynamic limitations of water oxidation are overcome by coupling the photocathodes to Si nanowire photoanodes for glycerol oxidation. These unassisted perovskite–silicon PEC devices attain partial C 2 hydrocarbon photocurrent densities of 155 µA cm -2 , 200-fold higher than conventional perovskite–BiVO 4 artificial leaves for water and CO 2 splitting. These insights establish perovskite semiconductors as a versatile platform towards PEC multicarbon synthesis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemical pH regulation in droplet microfluidics

Here we report a method for electrochemical pH regulation in microdroplets generated in a microfluidic device. The key finding is that controlled quantities of reagents can be generated electrochemically in moving microdroplets confined within a microfluidic channel. Additionally, products generated at the anode and cathode can be isolated within descendant microdroplets. Specifically, ~5 nL water-in-oil microdroplets are produced at a T-junction and then later split into two descendant droplets. During splitting, floor-patterned microelectrodes drive water electrolysis within the aqueous microdroplets to produce H + and OH - . This results in a change in the pHs of the descendant droplets. The droplet pH can be regulated over a range of 5.9 to 7.7 by injecting controlled amounts of charge into the droplets. When the injected charge is between -6.3 and 54.5 nC nL -1 , the measured pH of the resulting droplets is within ±0.1 pH units of that predicted based on the magnitude of the injected charge. This technique can likely be adapted to electrogeneration of other reagents within microdroplets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Perennial grass root system specializes for multiple resource acquisitions with differential elongation and branching patterns

Roots optimize the acquisition of limited soil resources, but relationships between root forms and functions have often been assumed rather than demonstrated. Furthermore, how root systems co-specialize for multiple resource acquisitions is unclear. Theory suggests that trade-offs exist for the acquisition of different resource types, such as water and certain nutrients. Measurements used to describe the acquisition of different resources should then account for differential root responses within a single system. To demonstrate this, we grew Panicum virgatum in split-root systems that vertically partitioned high water availability from nutrient availability so that root systems must absorb the resources separately to fully meet plant demands. We evaluated root elongation, surface area, and branching, and we characterized traits using an order-based classification scheme. Plants allocated approximately 3/4th of primary root length towards water acquisition, whereas lateral branches were progressively allocated towards nutrients. However, root elongation rates, specific root length, and mass fraction were similar. Our results support the existence of differential root functioning within perennial grasses. Similar responses have been recorded in many plant functional types suggesting a fundamental relationship. Root responses to resource availability can be incorporated into root growth models via maximum root length and branching interval parameters.

59 BASIC BIOLOGICAL SCIENCES↗

Effect of Initial Water Saturation on The Performance of Fracturing Fluids With and Without Polyallylamine under Simulated EGS Conditions

Objectives/Scope: StimuFrac (US Patents 9,873,828 B2 and 9,447,315 B2), a CO2-reactive polymer aqueous solution [polyallylamine (PAA) 1wt% in water] combined with CO2, can be used as a less water-intensive fracturing fluid for enhanced geothermal systems (EGS). Our previous results show that in hot dry rock (HDR), PAA/CO2 fracturing fluids outperformed other fluids such as water, CO2, and CO2/water in generating large fractures with less fluid consumed. The objective of this work is to study the effect of initial water saturation of rock on the performance of StimuFrac fluid in ½ foot cubic rock samples and under representative EGS pressure/temperature conditions using cyclic and constant flow rate injection strategies. The fracturing results are compared with results using different fracturing fluids in terms of controlling fracture propagation rates, fracture hydraulic conductivity, breakdown pressures and volumes of fluids required. Methods/Procedures/Process: In all tests, water was initially injected into the rock to increase the water saturation before the fracturing processes to simulate actual geothermal reservoir conditions. For the cyclic injection, one complete cycle consisted of (1) a PAA slug (or water slug) injection followed by (2) CO2 injection to initiate the fracture. In the second step of the first cycle, the pressure of CO2 is increased until a maximum pressure is reached (fracture is initiated at this moment), and then the injection of CO2 is allowed for another 30 seconds to propagate the fracture. Then, the two-step cycle of PAA followed by CO2 injection (up to 2-4 mL/min) was continued. For the constant flow rate injection strategies, the initial water saturation was increased by injecting water at 1000 psi and 200°C for three days. After that, an initial slug of water, CO2, or PAA was injected and then fracturing was initiated and propagated by injecting CO2 at a constant flow rate. Applications/Significance/Novelty: The results of this study suggest that water saturation, especially near the wellbore region, will significantly affect the fracturing fluid transmission into the rock porous media by changing the relative permeability of CO2 or water, thus affecting the fracture initiation and propagation. In this study, fracturing with cyclic injection or constant flow rate injection methods were performed using three different kinds of fluids systems. These fluids are water, CO2, or CO2 with PAA. Splitting the rock samples in half after fracturing reveals that the fracture propagation is significantly limited under these high water saturated conditions compared to dry initial conditions: The fractures propagate less than 1/3 length of the distance from the wellbore to rock surface, and in some cases no fracture is generated. This may be caused by the fact that leak-off is dominating the fracturing process and the injected fluid flow rate is not high enough to overcome the leak-off even under high flow rate injection conditions. Additionally, CO2 could be leaking off into the wellbore annulus and this may be making it more difficult to generate pressure gradients away from the near-wellbore region.

Jian, Guoqing↗

Recent Advances in Water Analysis with Gas Chromatograph Mass Spectrometers

We report on progress made in developing a water sampling system for detection and analysis of volatile organic compounds in water with a gas chromatograph mass spectrometer (GCMS). Two approaches are described herein. The first approach uses a custom water pre-concentrator for performing trap and purge of VOCs from water. The second approach uses a custom micro-volume, split-splitless injector that is compatible with air and water. These water sampling systems will enable a single GC-based instrument to analyze air and water samples for VOC content. As reduced mass, volume, and power is crucial for long-duration, manned space-exploration, these water sampling systems will demonstrate the ability of a GCMS to monitor both air and water quality of the astronaut environment, thereby reducing the amount of required instrumentation for long duration habitation. Laboratory prototypes of these water sampling systems have been constructed and tested with a quadrupole ion trap mass spectrometer as well as a thermal conductivity detector. Presented herein are details of these water sampling system with preliminary test results.

quadrupole ion trap↗

Soluble Organic Matter (SOM) analysis of the Hayabusa2 samples: The first results

The Hayabusa2 spacecraft successfully collected the surface and possible sub-surface materials of the asteroid 162173 Ryugu. Ryugu is a C-type asteroid characterized by a low-albedo surface probably consisting of hydrous minerals and carbonaceous materials. [1] The direct optical and spectral analysis of the returned samples indicates that Ryugu material is dominated by hydrous carbonaceous chondrite-like matter (similar to CI chondrites) [2]. Since carbonaceous chondrites have generally yielded various types of organic matter, the collected Ryugu grains are expected to contain diverse types of organic compounds including bio-related molecules. The occurrence of organic compounds in the Ryugu surface will provide clues to the evolution of prebiotic molecules and their preservations associated with aqueous alteration of the primitive asteroid. The initial analysis of soluble organic matter (SOM) of the Hayabusa2-returned samples has been performed by an international team consisting of 32 members. Because the sample amount available for comprehensive SOM analyses is limited, and because the SOM is expected to be present as a complex mixture of various types of organic compounds with very small concentrations of each compound, high-sensitivity and high-resolution analytical techniques have been developed using carbonaceous meteorites [e.g. 3]. Two aggregate samples of the Ryugu grains (A106 and C107) were allocated for the solvent extractions and bulk carbon (C), hydrogen (H), nitrogen (N), sulfur (S) and oxygen (O) measurements. The A106 sample was collected during the 1st sampling in February 2019 and the C107 sample was collected during the 2nd sampling in July 2019 after the Small Carry Impactor (SCI) operation. They consist mainly of particles smaller than 1 mm in diameter, and each sample mass was 38-39 mg. They were firstly investigated spectroscopically in the near infrared wavelength range by the Stone Team prior to the solvent extractions. Other small grains (A0080 and C0057) were also allocated for this study to investigate the spatial distribution of organic compounds on the sample surface. The extraction and analytical measurements implemented by the SOM Team are summarized in Figure 1. Each powder sample was extracted sequentially with non-polar to polar solvents, i.e., hexane, dichloromethane (DCM), methanol (MeOH) and H2O, for non-targeted analysis to reveal the compound composition. Each solvent extract was analyzed by solution state nuclear magnetic resonance (NMR) spectroscopy [4], Fourier transform- ion cyclotron resonance/mass spectrometry (FT-ICR/MS) with ESI and APPI ionization [5] and by high-resolution mass spectroscopy using Orbitrap MS coupled with nano-liquid chromatography (nanoLC/Orbitrap MS) [6], and using two dimensional gas chromatography/mass spectrometry (GC×GC/MS). The extracted residues were passed to the Chemistry Team for further inorganic element analysis. The other powder sample was subjected to the hot water extraction for amino acid analyses including chiral isomer separation, which was performed by three-dimensional (3D) high-performance liquid chromatography (HPLC) with high-sensitivity fluorescence detection (FD) [7] and by HPLC/FD coupled with quadrupole-time of flight/mass spectrometry (QToF/MS) [8]. After the hot water extraction, the residue was split into two halves. One half was further extracted with hydrochloric acid (HCl) to analyze for amino acids in bound-form. The other half was sequentially extracted with DCM/MeOH (1/1) to analyze semi-polar compounds such as polycyclic aromatic hydrocarbons (PAHs) by GC/MS, followed by further extraction with formic acid to analyze polar heterocyclic compounds, and subsequent extraction with HCl to detect bound-form polar compounds. The extracted residues were passed to the IOM Team for the analysis of insoluble organic matter (IOM). Compound-specific stable isotope analyses will be performed using GC/combustion/isotope ratio mass spectrometry (GC/C/IRMS) if the compound concentration is high enough to enable such an isotopic measurement. All extraction procedures were performed on an ISO 6 (Class 100) clean bench inside an ISO 5 (Class 1000) clean room. Baked serpentine powder was also analyzed as a procedural blank. In situ organic compound analysis with the molecular imaging was performed using desorption electrospray ionization (DESI) equipped with Orbitrap MS [9, 10], followed by spatial imaging of organic compounds using ToF/secondary ion mass spectrometry (ToF/SIMS) [11]. The bulk chemical and isotopic compositions of CNS and HO were determined using nano-elemental analysis/isotope ratio mass spectrometry (nanoEA/IRMS) [12] and EA/pyrolysis/IRMS, respectively. We have identified a variety of indigenous organic compounds in the extracts of both A106 and C107 samples. The Ryugu grains host organic molecules under the high-vacuum and cosmic-ray irradiation environment of the asteroid surface. The analysis of extracted molecules is in progress, and the first results will be presented at the symposium.

Hiroshi Naraoka↗