Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Warp”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

MRI Guidance for Accelerated Partial Breast Irradiation in Prone Position: Imaging Protocol Design and Evaluation

Purpose: To design and evaluate a magnetic resonance imaging (MRI) protocol to be incorporated in the simulation process for external beam accelerated partial breast irradiation. Methods and Materials: An imaging protocol was developed based on an existing breast MRI technique with the patient in the prone position on a dedicated coil. Pulse sequences were customized to exploit T1 and T2 contrast mechanisms characteristic of lumpectomy cavities. A three-dimensional image warping algorithm was included to correct for geometric distortions related to nonlinearity of spatially encoding gradients. Respiratory motion, image distortions, and susceptibility artifacts of 3.5-mm titanium surgical clips were examined. Magnetic resonance images of volunteers were acquired repeatedly to analyze residual setup deviations resulting from breast tissue deformation. Results: The customized sequences generated high-resolution magnetic resonance images emphasizing lumpectomy cavity morphology. Respiratory motion was negligible with the subject in the prone position. The gradient-induced nonlinearity was reduced to less than 1 mm in a region 15 cm away from the isocenter of the magnet. Signal-void regions of surgical clips were 4 mm and 8 mm for spin echo and gradient echo images, respectively. Typical residual repositioning errors resulting from breast deformation were estimated to be 3 mm or less. Conclusions: MRI guidance for accelerated partial breast irradiation with the patient in the prone position with adequate contrast, spatial fidelity, and resolution is possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiotherapy Optimization in a Quasi-Periodically Deforming Patient Model

Purpose: To present the implementation of a probability-based, four-dimensional (4D) intensity-modulated radiotherapy (IMRT) planning approach that explicitly optimizes the accumulated dose to moving tissue, estimated using the patient's probability density function (pdf) of respiratory motion. This is termed 'optimization in tissue's-eye-view'. Methods and Materials: The method incorporates 4D Monte Carlo dose calculation in multiple geometries of a respiratory-correlated CT dataset. The instance doses are weighted according to the breathing pdf and accumulated in a common reference geometry, which involves dose warping based on deformable registration. The algorithm produces deliverable multileaf collimator segments and was tested on a sample lung cancer patient dataset with large target excursion. Accumulated doses of the moving target and organs at risk of this plan were compared with those of corresponding margin-based static IMRT plans for free-breathing and gated treatment, as well as target tracking. Results: Target tracking provided best target coverage. Both the presented 4D IMRT approach for free-breathing treatment and gated treatment gave similar results for target coverage and lung dose, with significantly better target coverage than the margin-based static IMRT plan for free-breathing treatment. Conclusions: The presented 4D planning concept offers an alternative to gating by providing the optimal dose for free-breathing IMRT treatment. Although the focus of this study was 4D lung planning, the approach can be generally applied for IMRT optimization in randomly deforming patient models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of 4-dimensional Computed Tomography to 4-dimensional Cone-Beam Computed Tomography Deformable Image Registration for Lung Cancer Adaptive Radiation Therapy

Purpose: To evaluate 2 deformable image registration (DIR) algorithms for the purpose of contour mapping to support image-guided adaptive radiation therapy with 4-dimensional cone-beam CT (4DCBCT). Methods and Materials: One planning 4D fan-beam CT (4DFBCT) and 7 weekly 4DCBCT scans were acquired for 10 locally advanced non-small cell lung cancer patients. The gross tumor volume was delineated by a physician in all 4D images. End-of-inspiration phase planning 4DFBCT was registered to the corresponding phase in weekly 4DCBCT images for day-to-day registrations. For phase-to-phase registration, the end-of-inspiration phase from each 4D image was registered to the end-of-expiration phase. Two DIR algorithms—small deformation inverse consistent linear elastic (SICLE) and Insight Toolkit diffeomorphic demons (DEMONS)—were evaluated. Physician-delineated contours were compared with the warped contours by using the Dice similarity coefficient (DSC), average symmetric distance, and false-positive and false-negative indices. The DIR results are compared with rigid registration of tumor. Results: For day-to-day registrations, the mean DSC was 0.75 ± 0.09 with SICLE, 0.70 ± 0.12 with DEMONS, 0.66 ± 0.12 with rigid-tumor registration, and 0.60 ± 0.14 with rigid-bone registration. Results were comparable to intraobserver variability calculated from phase-to-phase registrations as well as measured interobserver variation for 1 patient. SICLE and DEMONS, when compared with rigid-bone (4.1 mm) and rigid-tumor (3.6 mm) registration, respectively reduced the average symmetric distance to 2.6 and 3.3 mm. On average, SICLE and DEMONS increased the DSC to 0.80 and 0.79, respectively, compared with rigid-tumor (0.78) registrations for 4DCBCT phase-to-phase registrations. Conclusions: Deformable image registration achieved comparable accuracy to reported interobserver delineation variability and higher accuracy than rigid-tumor registration. Deformable image registration performance varied with the algorithm and the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Escalation for Locally Advanced Lung Cancer Using Adaptive Radiation Therapy With Simultaneous Integrated Volume-Adapted Boost

Purpose: To test the feasibility of a planned phase 1 study of image-guided adaptive radiation therapy in locally advanced lung cancer. Methods and Materials: Weekly 4-dimensional fan beam computed tomographs (4D FBCT) of 10 lung cancer patients undergoing concurrent chemoradiation therapy were used to simulate adaptive radiation therapy: After an initial intensity modulated radiation therapy plan (0-30 Gy/2 Gy), adaptive replanning was performed on week 2 (30-50 Gy/2 Gy) and week 4 scans (50-66 Gy/2 Gy) to adjust for volume and shape changes of primary tumors and lymph nodes. Week 2 and 4 clinical target volumes (CTV) were deformably warped from the initial planning scan to adjust for anatomical changes. On the week 4 scan, a simultaneous integrated volume-adapted boost was created to the shrunken primary tumor with dose increases in 5 0.4-Gy steps from 66 Gy to 82 Gy in 2 scenarios: plan A, lung isotoxicity; plan B, normal tissue tolerance. Cumulative dose was assessed by deformably mapping and accumulating biologically equivalent dose normalized to 2 Gy-fractions (EQD2). Results: The 82-Gy level was achieved in 1 in 10 patients in scenario A, resulting in a 13.4-Gy EQD2 increase and a 22.1% increase in tumor control probability (TCP) compared to the 66-Gy plan. In scenario B, 2 patients reached the 82-Gy level with a 13.9 Gy EQD2 and 23.4% TCP increase. Conclusions: The tested image-guided adaptive radiation therapy strategy enabled relevant increases in EQD2 and TCP. Normal tissue was often dose limiting, indicating a need to modify the present study design before clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Clinical Investigation of Cone Beam Computed Tomography and Deformable Registration for Adaptive Proton Therapy for Lung Cancer

Purpose: An adaptive proton therapy workflow using cone beam computed tomography (CBCT) is proposed. It consists of an online evaluation of a fast range-corrected dose distribution based on a virtual CT (vCT) scan. This can be followed by more accurate offline dose recalculation on the vCT scan, which can trigger a rescan CT (rCT) for replanning. Methods and Materials: The workflow was tested retrospectively for 20 consecutive lung cancer patients. A diffeomorphic Morphon algorithm was used to generate the lung vCT by deforming the average planning CT onto the CBCT scan. An additional correction step was applied to account for anatomic modifications that cannot be modeled by deformation alone. A set of clinical indicators for replanning were generated according to the water equivalent thickness (WET) and dose statistics and compared with those obtained on the rCT scan. The fast dose approximation consisted of warping the initial planned dose onto the vCT scan according to the changes in WET. The potential under- and over-ranges were assessed as a variation in WET at the target's distal surface. Results: The range-corrected dose from the vCT scan reproduced clinical indicators similar to those of the rCT scan. The workflow performed well under different clinical scenarios, including atelectasis, lung reinflation, and different types of tumor response. Between the vCT and rCT scans, we found a difference in the measured 95% percentile of the over-range distribution of 3.4 ± 2.7 mm. The limitations of the technique consisted of inherent uncertainties in deformable registration and the drawbacks of CBCT imaging. The correction step was adequate when gross errors occurred but could not recover subtle anatomic or density changes in tumors with complex topology. Conclusions: A proton therapy workflow based on CBCT provided clinical indicators similar to those using rCT for patients with lung cancer with considerable anatomic changes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Voxel-Based Approach to Explore Local Dose Differences Associated With Radiation-Induced Lung Damage

Purpose: To apply a voxel-based (VB) approach aimed at exploring local dose differences associated with late radiation-induced lung damage (RILD). Methods and Materials: An interinstitutional database of 98 patients who were Hodgkin lymphoma (HL) survivors treated with postchemotherapy supradiaphragmatic radiation therapy was analyzed in the study. Eighteen patients experienced late RILD, classified according to the Radiation Therapy Oncology Group scoring system. Each patient's computed tomographic (CT) scan was normalized to a single reference case anatomy (common coordinate system, CCS) through a log-diffeomorphic approach. The obtained deformation fields were used to map the dose of each patient into the CCS. The coregistration robustness and the dose mapping accuracy were evaluated by geometric and dose scores. Two different statistical mapping schemes for nonparametric multiple permutation inference on dose maps were applied, and the corresponding P<.05 significance lung subregions were generated. A receiver operating characteristic (ROC)-based test was performed on the mean dose extracted from each subregion. Results: The coregistration process resulted in a geometrically robust and accurate dose warping. A significantly higher dose was consistently delivered to RILD patients in voxel clusters near the peripheral medial-basal portion of the lungs. The area under the ROC curves (AUC) from the mean dose of the voxel clusters was higher than the corresponding AUC derived from the total lung mean dose. Conclusions: We implemented a framework including a robust registration process and a VB approach accounting for the multiple comparison problem in dose-response modeling, and applied it to a cohort of HL survivors to explore a local dose–RILD relationship in the lungs. Patients with RILD received a significantly greater dose in parenchymal regions where low doses (∼6 Gy) were delivered. Interestingly, the relation between differences in the high-dose range and RILD seems to lack a clear spatial signature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Numerical stability of relativistic beam multidimensional PIC simulations employing the Esirkepov algorithm

Rapidly growing numerical instabilities routinely occur in multidimensional particle-in-cell computer simulations of plasma-based particle accelerators, astrophysical phenomena, and relativistic charged particle beams. Reducing instability growth to acceptable levels has necessitated higher resolution grids, high-order field solvers, current filtering, etc. except for certain ratios of the time step to the axial cell size, for which numerical growth rates and saturation levels are reduced substantially. This paper derives and solves the cold beam dispersion relation for numerical instabilities in multidimensional, relativistic, electromagnetic particle-in-cell programs employing either the standard or the Cole–Karkkainnen finite difference field solver on a staggered mesh and the common Esirkepov current-gathering algorithm. Good overall agreement is achieved with previously reported results of the WARP code. In particular, the existence of select time steps for which instabilities are minimized is explained. Additionally, an alternative field interpolation algorithm is proposed for which instabilities are almost completely eliminated for a particular time step in ultra-relativistic simulations.

43 PARTICLE ACCELERATORS↗

Direct ink writing of boron carbide monoliths

Direct ink writing – an extrusion-based additive manufacturing process – followed by pressureless sintering was investigated to produce boron carbide monoliths. The effects of ceramic powder loading and Pluronic binder concentration on the rheology of boron carbide pastes were studied and linked to both processing behaviour and final outcome in terms of sintered density and hardness. The effects of printing parameters, in particular orifice diameter and printing speed, were also investigated. Reducing the size of the extrusion nozzle from 584 μm to 406 μm led to significantly better shape retention, lower surface roughness, as well as higher density and hardness. A 203 μm printing orifice was also trialled but was unsuccessful due to faster drying kinetics that occurred with smaller ceramic struts resulting in rapid warping and nozzle clogging. Carbon-black – 8 wt% relative to B 4 C – acted as an effective sintering aid to increase both density and hardness. After optimisation of feedstock and printing parameters, few-layer samples (3–5 layers) had a density as high as ~ 97 % TD and a hardness of ~ 30 GPa. On the other hand, 18-layer specimens had a sintered density of ~ 87 % TD, despite a fully dense microstructure, due to the formation of a 3D array of inter-strut pores. Nevertheless, several issues that arose during manufacturing and post-processing were detrimental to the density and structural integrity of printed specimens; these issues were identified, discussed, and suggestions for future work are provided in this report.

36 MATERIALS SCIENCE↗

A thin-walled composite beam model for light-weighted structures interacting with fluids

A thin-walled beam model is proposed for structures of variable cross-section, which can be either open or closed and includes multicellular cross-sections with either isotropic or orthotropic materials. The proposed model does not require any priori definition of cross-sectional warping which instead results from the solution of the problem. To achieve that a special deformation pattern is superimposed on the bending deformation described by Euler–Bernoulli beam theory. All sectional properties are automatically incorporated in the analysis as a result of the usual variational formulation of the system of equations. The proposed model is specifically designed to simulate the dynamics of wind/hydrokinetic turbine blade with low computational cost, especially in fluid–structure interaction (FSI) simulation. A number of test cases have been carried out to validate the proposed structural model which show good agreement between the results obtained her e and the solutions available in literature. Finally, FSI simulation of a hydrokinetic blade under field condition is carried out to illustrate the capability of the current thin-walled beam model in practice.

42 ENGINEERING↗

Physics-based modeling and information-theoretic sensor and settings selection for tool wear detection in precision machining

Precision machining of metals is an energy intensive process with applications and impacts across the manufacturing industry. The energy efficiency, product yield, and maintenance of the precision machine require a digital twin that can assist with prognostics and health management. In this report a physics-based model is developed and validated against face milling data, and then used for the timely and precise inference of machining faults that cannot be measured directly. Computer numerical control (CNC) measurements of power and force are used through this physics-based machining model to predict deviations of the outputs of power consumption and cutting forces during normal operation. A model-based fault detection and isolation methodology is applied to determine the optimal (traditional and available) sensor suite and the test settings (admissible input values) that improve the inference of tool wear in face milling. The optimal sensor suite and input test settings are obtained by solving a mixed integer non-linear program that optimizes information-theoretic metrics relevant to the detection and isolation of tool wear from steady-state or transient machining measurements. Dynamic time warping and k—NN classification are then used to validate the robustness of the optimal design for fault detection test design, including the optimal sensor suite.

42 ENGINEERING↗

Serial Section Registration of Axonal Confocal Microscopy Datasets for Long-Range Neural Circuit Reconstruction

In the context of long-range digital neural circuit reconstruction, this paper investigates an approach for registering axons across histological serial sections. Tracing distinctly labeled axons over large distances allows neuroscientists to study very explicit relationships between the brain's complex interconnects and, for example, diseases or aberrant development. Large scale histological analysis requires, however, that the tissue be cut into sections. In immunohistochemical studies thin sections are easily distorted due to the cutting, preparation, and slide mounting processes. In this work we target the registration of thin serial sections containing axons. Sections are first traced to extract axon centerlines, and these traces are used to define registration landmarks where they intersect section boundaries. The trace data also provides distinguishing information regarding an axon's size and orientation within a section. We propose the use of these features when pairing axons across sections in addition to utilizing the spatial relationships amongst the landmarks. The global rotation and translation of an unregistered section are accounted for using a random sample consensus (RANSAC) based technique. An iterative nonrigid refinement process using B-spline warping is then used to reconnect axons and produce the sought after connectivity information.

59 BASIC BIOLOGICAL SCIENCES↗

Influence of quenching agent on microstructure, properties and thermal stress of SiC{sub p}/2009 composites

15% vol. SiC{sub p}/2009 composites prepared by powder metallurgy were quenched in room temperature water and 20% polyethylene glycol (PEG) solution respectively, then aged naturally. The influence of quenching agent on microstructure, properties and thermal stress of SiC{sub p}/2009 composites were investigated by means of scanning/transmission electron microscope, hardness and tensile test. The results showed that the number of precipitated phase in water quenched composites increased, with much finer in size and more homogeneous in distribution compared with 20% PEG quenched one. Meanwhile, the density of dislocation in composites by water quenching was also much higher. Intergranular corrosion did not occur with the two quenching agents. The 20% PEG quenched composites exhibited slight lower hardness and higher electrical conductivity than that of water quenched one. The two quenched composites showed same level in tensile strength, but the yield strength of water-quenched composites was higher (8 MPa, 3%). The usage of 20% PEG reduced thermal stress and minimized warping deformation of the parts, it is a more suitable quenching agent for SiC{sub p}/2009 composites in engineering application fields. - Highlights: •SiC{sub p}/2009 composites quenched by water and 20% PEG solution were investigated. •Aging precipitation behavior of SiC{sub p}/2009 composites is sensitive to quenchant. •Influence of quenching agent on properties of SiC{sub p}/2009 composites are minimal. •Quenching with 20% PEG reduces thermal stress of SiC{sub p}/2009 composites remarkably. •20% PEG is a more suitable quenching agent for SiC{sub p}/2009 composites than water.

36 MATERIALS SCIENCE↗

A New Approach to Computing Normal Tissue Complication Probability of an Intensity-Modulated Radiotherapy Treatment with Stereotactic Radiotherapy Boost of Nasopharyngeal Carcinoma: A Case Study

We attempted to develop a method to compute the normal tissue complication probability (NTCP) of various critical organs from combined intensity-modulated radiotherapy (IMRT) and stereotactic radiotherapy (SRT) boost treatment of nasopharyngeal carcinoma (NPC), with the aid of a nonlinear image registration method. The SRT's planning computed tomography (CT) of a NPC patient treated with IMRT was warped to the IMRT's planning CT using a nonlinear image registration. Because CT and dose were inherently in-register, the entire dose distribution could be deformed using the same deformation field derived from the two CT sets. Using the biologically effective dose concept and the linear-quadratic model, physical doses of IMRT and SRT were converted to a 2Gy-per-fraction equivalent dose to facilitate dose summation. The variation of organs' maximum doses of the combined treatments between traditional maximum dose sum and the proposed method was 1.5Gy {+-} 1.7Gy. After the correction of the effect of fractionation and dose heterogeneity within each organ, NTCP of each organ of interest was computed for the combined treatments. Based on the results of this case study, it is believed that dose registration could be a method for the NTCP computation of various critical organs when different fractionation schemes of radiation therapy treatment are instituted.

61 RADIATION PROTECTION AND DOSIMETRY↗

An Isoprene Lipid-Binding Protein Promotes Eukaryotic Coenzyme Q Biosynthesis

The biosynthesis of coenzyme Q presents a paradigm for how cells surmount hydrophobic barriers in lipid biology. In eukaryotes, CoQ precursors—among nature’s most hydrophobic molecules—must somehow be presented to a series of enzymes peripherally associated with the mitochondrial inner membrane. Here in this paper, we reveal that this process relies on custom lipid-binding properties of COQ9. We show that COQ9 repurposes the bacterial TetR fold to bind aromatic isoprenes with high specificity, including CoQ intermediates that likely reside entirely within the bilayer. We reveal a process by which COQ9 associates with cardiolipin-rich membranes and warps the membrane surface to access this cargo. Finally, we identify a molecular interface between COQ9 and the hydroxylase COQ7, motivating a model whereby COQ9 presents intermediates directly to CoQ enzymes. Overall, our results provide a mechanism for how a lipid-binding protein might access, select, and deliver specific cargo from a membrane to promote biosynthesis.

59 BASIC BIOLOGICAL SCIENCES↗

Generation of multi-charged high current ion beams using the SMIS 37 gas-dynamic electron cyclotron resonance (ECR) ion source

A gas-dynamic ECR ion source (GaDIS) is distinguished by its ability to produce high current and high brightness beams of moderately charged ions. Contrary to a classical ECR ion source where the plasma confinement is determined by the slow electron scattering into an empty loss-cone, the higher density and lower electron temperature in a GaDIS plasma lead to an isotropic electron distribution with the confinement time determined by the prompt gas-dynamic flow losses. As a result, much higher ion fluxes are available, however a decrease in the confinement time of the GaDIS plasma lowers the ion charge state. The gas-dynamic ECR ion source concept has been successfully realized in the SMIS 37 experimental facility operated at the Institute of Applied Physics, Russia. The use of high-power (~100 kW) microwave (37.5 GHz) radiation provides a dense plasma (~10 13 cm -3 ) with a relatively low electron temperature (~50- 100 eV) and allows for the generation of high current (~1 A/cm 2 ) beams of multi-charged ions. In this work we report on the present status of the SMIS 37 ion source and discuss the advanced numerical modeling of ion beam extraction using the particle-in-cell code WARP

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical simulations of early-stage dynamics of electron bunches emitted from plasmonic photocathodes

High-brightness electron sources are a key ingredient to the development of compact accelerator-based light sources. The electron sources are commonly based on (linear) photoemission process where a laser pulse with proper wavelength impinges on the surface of a metallic or semiconductor photocathode. Very recently, the use of plasmonic cathodes - cathodes with a nano-patterned surface - have demonstrated great enhancement in quantum efficiencies (Li et al., 2013 [1]). Alternatively, this type of photocathodes could support the formation of structured beams composed of transversely-separated beamlets. In this paper we discuss numerical simulations of the early-stage beam dynamics of the emission process from plasmonic cathodes carried out using the Warp (Friedman et al., 2014 [2]) framework. Furthermore, the model is used to investigate the properties of beams emitted from these photocathode and subsequently combined with particle-in-cell simulations to explore the imaging of cathode pattern after acceleration in a radiofrequency gun.

43 PARTICLE ACCELERATORS↗

Power performance and loads characterization of laboratory-scale cross-flow rotors fabricated using additive manufacturing

Tidal energy conversion is a relatively new application for additive manufacturing (AM), where the focus has been on fabricating axial-flow turbine blades. AM techniques add material precisely where it is needed, creating more complex shapes with less waste. Cross-flow rotor geometry presents an opportunity for AM to improve rotor performance by fabricating features that cannot be created economically via conventional manufacturing. The challenges associated with using AM in cross-flow design include water resistance and degradation over time while retaining a level of quality equivalent to conventionally machined parts. In this work, AM materials were tested by environmentally conditioning samples in a seawater tank for 5 months, followed by performance and phase-resolved load testing of laboratory-scale rotors in a hydraulic flume. We found that while metals like titanium and Inconel have excellent performance in marine environments, achieving the desired geometry and performance is difficult. Thermoplastics degraded in seawater but were easier to form into desired geometries and could exceed the performance of an aluminum control rotor. Warping and surface finish were significant detractors from AM rotor performance. These results suggest that the primary benefits of using AM for cross-flow rotors is to quickly fabricate and test unconventional rotor geometries.

16 TIDAL AND WAVE POWER↗

Search for resonances decaying into photon pairs in 139 fb -1 of pp collisions at s=13 TeV with the ATLAS detector

Searches for new resonances in the diphoton final state, with spin 0 as predicted by theories with an extended Higgs sector and with spin 2 using a warped extra-dimension benchmark model, are presented using 139 fb$^{-1}$ of $\sqrt{s} = $ 13 TeV $pp$ collision data collected by the ATLAS experiment at the LHC. No significant deviation from the Standard Model is observed and upper limits are placed on the production cross-section times branching ratio to two photons as a function of the resonance mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗