Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WAVELENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Photon antibunching in single-walled carbon nanotubes at telecommunication wavelengths and room temperature

We investigated the photoluminescence of individual air-suspended single-walled carbon nanotubes (SWNTs) from 6 to 300 K. Time-resolved and antibunching measurements over the telecommunication wavelength range were performed using a superconducting single-photon detector. We detected moderate temperature independent antibunching behavior over the whole temperature range studied. To investigate the exciton dynamics, which is responsible for the antibunching behavior, we measured excitation-power and temperature dependence of the photoluminescence spectra and lifetime decay curves. These measurements suggested an exciton confinement effect that is likely caused by high-dielectric amorphous carbon surrounding the SWNTs. These results indicate that SWNTs are good candidates for light sources in quantum communication technologies operating in the telecommunication wavelength range and at room temperature.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Note: On the wavelength dependence of the intensity calibration factor of extreme ultraviolet spectrometer determined with profile measurement of bremsstrahlung continuum

The absolute calibration factor of extreme ultraviolet spectroscopic instrument which has recently been determined from absolute radiation profile measurement of bremsstrahlung continuum has been investigated by comparing the calculated diffraction efficiency of grating. An overall tendency of the wavelength dependence of the calibration factor from 40 Å to 500 Å can be reproduced by that of the grating efficiency, especially the agreement between the measured calibration factor and the calculated grating efficiency has been found to be fairly good for the wavelength range 200 Å-500 Å.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intersubband transitions in nonpolar GaN/Al(Ga)N heterostructures in the short- and mid-wavelength infrared regions

This paper assesses nonpolar m- and a-plane GaN/Al(Ga)N multi-quantum-wells grown on bulk GaN for intersubband optoelectronics in the short- and mid-wavelength infrared ranges. The characterization results are compared to those for reference samples grown on the polar c-plane, and are verified by self-consistent Schrödinger-Poisson calculations. The best results in terms of mosaicity, surface roughness, photoluminescence linewidth and intensity, as well as intersubband absorption are obtained from m-plane structures, which display room-temperature intersubband absorption in the range from 1.5 to 2.9 μm. Based on these results, a series of m-plane GaN/AlGaN multi-quantum-wells were designed to determine the accessible spectral range in the mid-infrared. These samples exhibit tunable room-temperature intersubband absorption from 4.0 to 5.8 μm, the long-wavelength limit being set by the absorption associated with the second order of the Reststrahlen band in the GaN substrates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The development of new radiation protocols for insect sterilization using long wavelength x-rays

Control of insect species for the protection of crops, livestock, and prevention of disease such as dengue fever and malaria is a high priority in today’s global economy. Traditional methods such as pesticides have fallen out of favor because its effects are indiscriminate as well as adverse and unpredictable impacts on the environment. Modern novel techniques such as genetic modification have had trouble gaining traction due to ethics concerns and the potential for unforeseen side effects. One approach that has gained traction and has proven its efficacy is the use of ionizing radiation to affect sterility in insect species in order to scale back their population. Known as Sterile Insect Technique (SIT), it has proven very effective in eradicating certain dipteran insect populations. However, when standard sterilization methods developed for dipertans are applied to mosquito populations significant complications arise, such as an inability to compete with non-irradiated males and high mortality rates. We have investigated the effect of treatment with x-rays of different wavelengths on x-ray sterilized mosquito males. Our results have demonstrated that longer wavelength x-rays have a significant effect on the outcome of the sterile males’ longevity as well as an increase on the efficacy of sterilization while employing a substantially lower dose.

60 APPLIED LIFE SCIENCES↗

Interference with a quantum dot single-photon source and a laser at telecom wavelength

The interference of photons emitted by dissimilar sources is an essential requirement for a wide range of photonic quantum information applications. Many of these applications are in quantum communications and need to operate at standard telecommunication wavelengths to minimize the impact of photon losses and be compatible with existing infrastructure. Here, we demonstrate for the first time the quantum interference of telecom-wavelength photons from an InAs/GaAs quantum dot single-photon source and a laser; an important step towards such applications. The results are in good agreement with a theoretical model, indicating a high degree of indistinguishability for the interfering photons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-performance short-wavelength infrared photodetectors based on type-II InAs/InAs{sub 1-x}Sb{sub x}/AlAs{sub 1−x}Sb{sub x} superlattices

A high-performance short-wavelength infrared n-i-p photodiode based on InAs/InAs{sub 1−x}Sb{sub x}/AlAs{sub 1−x}Sb{sub x} type-II superlattices on GaSb substrate has been demonstrated. The device is designed to have a 50% cut-off wavelength of ∼1.8 μm at 300 K. The photodetector exhibited a room-temperature (300 K) peak responsivity of 0.47 A/W at 1.6 μm, corresponding to a quantum efficiency of 37% at zero bias under front-side illumination, without any anti-reflection coating. With an R × A of 285 Ω cm{sup 2} and a dark current density of 9.6 × 10{sup −5} A/cm{sup 2} under −50 mV applied bias at 300 K, the photodiode exhibited a specific detectivity of 6.45 × 10{sup 10 }cm Hz{sup 1/2}/W. At 200 K, the photodiode exhibited a dark current density of 1.3 × 10{sup −8} A/cm{sup 2} and a quantum efficiency of 36%, resulting in a detectivity of 5.66 × 10{sup 12 }cm Hz{sup 1/2}/W.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Short-wavelength interband cascade infrared photodetectors operating above room temperature

High temperature operation (250–340 K) of short-wavelength interband cascade infrared photodetectors (ICIPs) with InAs/GaSb/Al 0.2 In 0.8 Sb/GaSb superlattice absorbers has been demonstrated with a 50% cutoff wavelength of 2.9 μm at 300 K. Two ICIP structures, one with two and the other with three stages, were designed and grown to explore this multiple-stage architecture. At λ = 2.1 μm, the two- and three-stage ICIPs had Johnson-noise-limited detectivities of 5.1 × 10 9 and 5.8 ×10 9 cm Hz 1/2 /W, respectively, at 300 K. The better device performance of the three-stage ICIP over the two-stage ICIP confirmed the advantage of more stages for this cascade architecture. Furthermore, an Arrhenius activation energy of 450 meV is extracted for the bulk resistance-area product, which indicates the dominance of the diffusion current at these high temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long wavelength stimulated emission up to 9.5 μm from HgCdTe quantum well heterostructures

Stimulated emission from waveguide HgCdTe structures with several quantum wells inside waveguide core is demonstrated at wavelengths up to 9.5 μm. Photoluminescence line narrowing down to kT energy, as well as superlinear rise in its intensity evidence the onset of the stimulated emission, which takes place under optical pumping with intensity as small as ∼0.1 kW/cm{sup 2} at 18 K and 1 kW/cm{sup 2} at 80 K. One can conclude that HgCdTe structures potential for long-wavelength lasers is not exhausted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A fiber optic, ultraviolet light-emitting diode-based, two wavelength fluorometer for monitoring reactive adsorption

Construction and use of an ultraviolet light-emitting diode-based fluorometer for measuring photoluminescence (PL) from powder samples with a fiber optic probe is described. Fluorescence at two wavelengths is detected by miniature photomultiplier tubes, each equipped with a different band pass filter, whose outputs are analyzed by a microprocessor. Photoluminescent metal oxides and hydroxides, and other semiconducting nanoparticles, often undergo changes in their emission spectra upon exposure to reactive gases, and the ratio of the PL intensities at two wavelengths is diagnostic of adsorption. Use of this instrument for reactive gas sensing and gas filtration applications is illustrated by measuring changes in the PL ratio for zirconium hydroxide and zinc oxide particles upon exposure to air containing low concentrations of sulfur dioxide.

36 MATERIALS SCIENCE↗

Very high quantum efficiency in InAs/GaSb superlattice for very long wavelength detection with cutoff of 21 μm

The authors report the dependence of the quantum efficiency on beryllium concentration in the active region of type-II InAs/GaSb superlattice infrared detector with a cutoff wavelength around 21 μm. It is found that the quantum efficiency and responsivity show a clear delineation in comparison to the doping concentration. The quantum efficiency is further improved by gradually doping in the absorbing region. At 77 K, the 50% cutoff wavelength of the VLWIR detector is 18 μm, and the R{sub 0}A is kept at a stable value of 6 Ω cm{sup 2}. Different beryllium concentration leads to an increase of an average quantum efficiency in the 8–15 μm window from 35% to 55% with a π-region thickness of 3.0 μm, for U{sub bias} = −0.3 V, and no anti-reflection coating. As for a further result, the quantum efficiency reaches at a maximum value of 66% by gradually doping in the absorbing region with the peak detectivity of 3.33 × 10{sup 10 }cm Hz{sup 1/2}/W at 15 μm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wavelength dependence of Verdet constant of Tb{sup 3+}:Y{sub 2}O{sub 3} ceramics

Samples of the magneto-active material—Tb{sup 3+}:Y{sub 2}O{sub 3} ceramics with Tb{sup 3+} ion concentrations of 10%, 20%, 30%, and 100% (Tb{sub 2}O{sub 3})—were prepared and studied. The wavelength dependence of Verdet constant in the 380 nm–1750 nm range was approximated for all investigated ceramic samples and was predicted for a pure Tb{sub 2}O{sub 3} material. Tb{sub 2}O{sub 3} ceramics demonstrates a more than three times higher Verdet constant in comparison with terbium gallium garnet crystal or ceramics. The linear dependence of the Verdet constant on Tb{sup 3+} ion concentration in the Tb{sup 3+}:Y{sub 2}O{sub 3} ceramics was demonstrated. The obtained data will be useful for fabricating magneto-optical elements of Faraday devices based on Tb{sup 3+}:Y{sub 2}O{sub 3} with arbitrary Tb{sup 3+} ion concentration operating at room temperature in the wavelength range of 380 nm–1750 nm.

36 MATERIALS SCIENCE↗

Speckle-based at-wavelength metrology of X-ray mirrors with super accuracy

X-ray active mirrors, such as bimorph and mechanically bendable mirrors, are increasingly being used on beamlines at modern synchrotron source facilities to generate either focused or “tophat” beams. As well as optical tests in the metrology lab, it is becoming increasingly important to optimise and characterise active optics under actual beamline operating conditions. Recently developed X-ray speckle-based at-wavelength metrology technique has shown great potential. The technique has been established and further developed at the Diamond Light Source and is increasingly being used to optimise active mirrors. Details of the X-ray speckle-based at-wavelength metrology technique and an example of its applicability in characterising and optimising a micro-focusing bimorph X-ray mirror are presented. Importantly, an unprecedented angular sensitivity in the range of two nanoradians for measuring the slope error of an optical surface has been demonstrated. Such a super precision metrology technique will be beneficial to the manufacturers of polished mirrors and also in optimization of beam shaping during experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emission-wavelength tuning of InAs quantum dots grown on nitrogen-δ-doped GaAs(001)

We studied the structural and photoluminescence (PL) characteristics of InAs quantum dots (QDs) grown on nitrogen (N) δ-doped GaAs(001). The emission wavelength for low-density N-δ doping exhibited a blueshift with respect to that for undoped GaAs and was redshifted with increasing N-sheet density. This behavior corresponded to the variation in the In composition of the QDs. N-δ doping has two opposite and competing effects on the incorporation of Ga atoms from the underlying layer into the QDs during the QD growth. One is the enhancement of Ga incorporation induced by the lattice strain, which is due to the smaller radius of N atoms. The other is an effect blocking for Ga incorporation, which is due to the large bonding energy of Ga-N or In-N. At a low N-sheet density, the lattice-strain effect was dominant, while the blocking effect became larger with increasing N-sheet density. Therefore, the incorporation of Ga from the underlying layer depended on the N-sheet density. Since the In-Ga intermixing between the QDs and the GaAs cap layer during capping also depended on the size of the as-grown QDs, which was affected by the N-sheet density, the superposition of these three factors determined the composition of the QDs. In addition, the piezoelectric effect, which was induced with increased accumulation of lattice strain and the associated high In composition, also affected the PL properties of the QDs. As a result, tuning of the emission wavelength from 1.12 to 1.26 μm was achieved at room temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Towards strong light-matter coupling at the single-resonator level with sub-wavelength mid-infrared nano-antennas

We report a crucial step towards single-object cavity electrodynamics in the mid-infrared spectral range using resonators that borrow functionalities from antennas. Room-temperature strong light-matter coupling is demonstrated in the mid-infrared between an intersubband transition and an extremely reduced number of sub-wavelength resonators. By exploiting 3D plasmonic nano-antennas featuring an out-of-plane geometry, we observed strong light-matter coupling in a very low number of resonators: only 16, more than 100 times better than what reported to date in this spectral range. The modal volume addressed by each nano-antenna is sub-wavelength-sized and it encompasses only ≈4400 electrons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tune-out wavelengths for helium atom in plasma environments

We investigate the effect of plasma screening on the tune-out wavelengths for helium atom using correlated exponential wave function within the framework of Debye shielding approach. The pseudostate summation technique has been used to calculate the dynamic dipole polarizability for the states (2 {sup 1}S, 3 {sup 1}S, 2 {sup 3}S, 3 {sup 3}S) of helium embedded in plasma environments. In a free-atomic system, our calculated results are in agreement with available theoretical and experimental predictions. The tune-out wavelengths show interesting behavior as functions of screening parameter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wavelength modulation laser-induced fluorescence for plasma characterization

Laser-Induced Fluorescence (LIF) spectroscopy is an essential tool for probing ion and atom velocity distribution functions (VDFs) in complex plasmas. VDFs carry information about the kinetic properties of species that is critical for plasma characterization. Accurate interpretation of these functions is challenging due to factors such as multicomponent distributions, broadening effects, and background emissions. Our research investigates the use of Wavelength Modulation (WM) LIF to enhance the sensitivity of VDF measurements. Unlike standard Amplitude Modulation (AM) methods, WM–LIF measures the derivative of the LIF signal. This approach makes variations in VDF shape more pronounced. VDF measurements with WM–LIF were investigated with both numerical modeling and experimental measurements. The developed model enables the generation of both WM and AM signals, facilitating comparative analysis of fitting outcomes. Experiments were conducted in a weakly collisional argon plasma with magnetized electrons and non-magnetized ions. Measurements of the argon ion VDFs employed a narrow-band tunable diode laser, which scanned the 4p 4 D 7/2 –3d 4 F 9/2 transition centered at 664.553 nm in vacuum. A lock-in amplifier detected the second harmonic WM signal, which was generated by modulating the laser wavelength with an externally controlled piezo-driven mirror of the diode laser. Finally, our findings indicate that the WM–LIF signal is more sensitive to fitting parameters, allowing for better identification of VDF parameters such as the number of distribution components, their temperatures, and velocities. In addition, WM–LIF can serve as an independent method to verify AM measurements and is particularly beneficial in environments with substantial light noise or background emissions, such as those involving thermionic cathodes and reflective surfaces.

47 OTHER INSTRUMENTATION↗

Stimulated-emission wavelength switching in optically pumped InGaAs/AlGaInAs laser heterostructures

We report stimulated near-IR emission in optically pumped InGaAs/AlGaInAs heterostructures and stimulated- emission wavelength switching from 1.9 to 1.5 and then to 1.2 {mu}m with increasing optical pump intensity. The wavelength switching behaviour of the heterostructures depends on their geometry (band-gap profile) and the competition between stimulated emissions at different frequencies in different parts of the system. (control of laser radiation parameters)

36 MATERIALS SCIENCE↗

Effect of laser radiation absorption in water and blood on the optimal wavelength for endovenous obliteration of varicose veins

This work examines laser radiation absorption in water and blood at the wavelengths that are used in endovenous laser treatment (EVLT): 0.81-1.06, 1.32, 1.47, 1.5 and 1.56 {mu}m. It is shown that the best EVLT conditions are ensured by 1.56-{mu}m radiation. Analysis of published data suggests that even higher EVLT efficacy may be achieved at wavelengths of 1.68 and 1.7 {mu}m. (laser medicine)

62 RADIOLOGY AND NUCLEAR MEDICINE↗